MODEL ZAC ZONE ANNUNCIATOR/CONTROLLER DESIGNED FOR ZONE ANNUNCIATION AND MONITORING

Similar documents
MODEL ZA-8N EIGHT ZONE ANNUNCIATOR FOR ALL MONITORING APPLICATIONS OUTSTANDING FEATURES

Independent Zone Control (I.Z.C.)

Long Range Radio Alarm Transmitter

Model 17A00 Expansion Enclosure

Long Range Radio Alarm Transmitter

Figure 1. These Installation Instructions -1- K4866 4/00 OmniProx Reader Model Series OP-10/20/30/40

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN THE LIGHTNING FLASH AND ARROW- HEAD WITHIN THE

Fire Control/Communicator

FireNET Plus Wiring Instructions

Installation Instructions

Crypto-Lock. Model CC-8521B Updated 7/17. Access Control System. MONITEQ, Inc. INSTRUCTION MANUAL

EVO192 v3.0 Fire and Burglary What s New

RMS/RPX Reader. User Manual

RAM3 Remote Alarm Module

Long Range Radio Alarm Transmitter

Supplement to The PDRP-1001/PDRP-1001A/PDRP-1001E Deluge Preaction Control Panel Manual

0$; Installation Instructions. Computerized Control Panel '(6&5,37,21 63(&,),&$7,216 DE5011 1

TECHNICAL DATA OBSOLETE

INSTALLATION GUIDE XR5FC AND XR5SL COMMERCIAL FIRE PANELS

INSTALLATION MANUAL PC25OO

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

Pipo Communications. Model ST-888. DTMF ANI/ENI Display Decoder

Installation Guide for models:

DS7400Xi Addressable Control/ Communicator

Section PERIMETER SECURITY SYSTEMS

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5

MODEL KP-200 VANDAL RESISTANT & WEATHERPROOF FLUSH MOUNT DIGITAL KEYPAD DESIGNED FOR ACCESS CONTROL APPLICATIONS

TABLE OF CONTENTS TABLE OF CONTENTS 1

Installation Guide for models:

RELEASE DEVICE CONTROLS

SEC 2000 Millenium Infrared Gas Detector

30.45 Electric Release PDRP-2001

Using Your GEM-P400 Security System H

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

IMPORTANT SAFETY INSTRUCTIONS

KT-100 Door Controller

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

EVAPORATIVE COOLER W

Self-Setting Clock Radio

With Remote Control. English. Model

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

TABLE OF CONTENTS. FOR THE RECORD 15 PROGRAMMING WORK SHEETS 16 CONTROL PANEL WIRING DIAGRAM inside back cover

Voice Module Installation Guide. For use with ProSYS 16, ProSYS 40, ProSYS 128

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

FW-RA-LED Remote Multiplex Annunciator Panels

Installation Instructions

Universal Fan and Light Remote Control

Global Water Instrumentation, Inc.

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

RAM-208. Remote Multiplex Annunciator Panel. Wiring & Installation Installation Manual COMMON TROUBLE A.C. ON SIGNAL SILENCED BUZZER SILENCE

Owner s Manual. PIR-1 IR Learner

SPECIFICATION FOR A TOTAL FLOOD ECARO-25 TM CLEAN AGENT FIRE SUPPRESSION SYSTEM FOR USE WITH THE SHP PRO CONTROL PANEL SYSTEM

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

GROUP OF COMPANIES. MERLIN STEALTH Electric Fence Energizer. Users Manual

INSTALLATION GUIDE XTLN-WIFI PANEL

ADEMCO 4208SNF V-Plex Universal Class A Module INSTALLATION AND SETUP GUIDE

INSTALLATION MANUAL PC56O. Version 1.OA

PERS-3600 PERSONAL EMERGENCY REPORTING SYSTEM INSTALLATION & OPERATION INSTRUCTIONS

NetworX Series NX-870E Fire Supervision Module Installation and Startup

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

D2071A. Operation & Installation Guide Fire Alarm Control Panel

Installation, Operating and Maintenance Manual

1 Description. 2 Specifications. HP600ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52393:A 1/05/06 ECN

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

4100U City and Relay Cards Installation Instructions

MODEL B2 INSTALLATION MANUAL

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

4500 THERMOSTAT INSTALLATION INSTRUCTIONS

LUMA-NET 804CP / 808CP REMOTE CONTROL PANEL

XR10/XR20 Command Processor Panels Installation Guide

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH SHP-PRO CONTROL PANEL

TECHNOLOGY CORP. Taking a bite out of energy costs. Instruction Manual for the ORKA Remote Thermostat/Humidity Controller.

Booster Power Supply Manual

Safety & Installation Instructions

INSTALLATION MANUAL PC15OO

Twin Bell Digital Clock

Model 4001 Series Single Channel Controller

MR-2316-AT/Z Remote Annunciator

LED Driver Module. These instructions contain procedures to follow in order to avoid personal injury and damage to equipment.

CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA

AL800ULADA. NAC Power Extender. Installation Guide

Ohm Metrics. Instruction Manual. Continuous Workstation Monitors Model CM1600. T r a n s f o r m i n g T e c h n o l o g i e s, L L C

Installation Guide. Control/Communicator

Excel-EN Conventional Fire Control Panel

Addressable NAC Output Module D327A

Beacon 800 Gas Monitor Operator s Manual

AMC-RAM-4. Refrigerant Alarm Module USER MANUAL. Please read the installation and operating instructions completely and carefully before starting.

Hazardous Area Ringdown Telephone

PSN-1000 & PSN 1000(E) Installation Manual

AIM TECHNICAL MANUAL PATENT PENDING STOP REMEMBER TO ACTIVATE UNIT BEFORE TESTING. See page 9 for Activation Instructions

Installation Manual Version 1.3. Long Range RF Transmitter. How to contact us:

52 BERKSHIRE CEILING FAN

Beacon 410A Gas Monitor Operator s Manual

Towel Warmer MAKE EVERYDAY A SPA DAY

Transcription:

MODEL ZAC-32 32 ZONE ANNUNCIATOR/CONTROLLER DESIGNED FOR ZONE ANNUNCIATION AND MONITORING 32 HARD WIRED ZONES CAN BE NORMALLY-OPEN OR NORMALLY-CLOSED ZONE WIRING RUNS CAN BE AS FAR AS 10,000 FEET FROM CONTROL CABINET UP TO FOUR REMOTE CONSOLES CAN BE ADDED TO A SYSTEM CONTROL CABINET CONNECTED TO CONSOLE WITH FOUR WIRE CABLE REMOTE CONSOLE CAN BE LOCATED UP TO 1000 FEET FROM CONTROL CABINET BUILT-IN AUDIBLE SIGNAL, SOUND LEVEL IS 80dB @ 3 FEET SIXTEEN FOUR DIGIT ACCESS CODES ALL ZONE CONTROL AND ZONE STATUS ON REMOTE CONSOLE ZONE BY-PASS CAPABILITY, ZONE BY-PASS OUTPUT, DAY ZONE BYPASS THIRTY-TWO RED LED ZONE STATUS INDICATORS LOW STAND-BY BATTERY OUTPUT, AC POWER FAILURE OUTPUT ALL FIELD WIRING TERMINATED IN CENTRALLY LOCATED CONTROL CABINET ALARM CONTROLS CORPORATION

MODEL ZAC-32 ZONE STATUS INDICATORS LED OFF - ZONE SECURE LED FLASHING - ZONE BYPASSED LED ON - ZONE VIOLATED DIGITAL KEYPAD THE DIGITAL KEYPAD IS USED TO ACCESS AND CONTROL ALL SYSTEM FUNCTIONS: ANNUNCIATOR RESET, ZONE MEMORY RESET, DAY ZONE MODE AND ZONE BYPASSING VALID CODE INDICATOR WHEN LED IS ON A VALID CODE HAS BEEN ENTERED DAY ZONE INDICATOR WHEN LED IS ON ALL DAY ZONES ARE BYPASSED LOW BATTERY INDICATOR WHEN LED IS ON STANDBY BATTERY IS LOW POWER FAILURE INDICATOR WHEN LED IS ON AC POWER HAS FAILED, SYSTEM IS OPERATING ON STANDBY BATTERY AUDIBLE SIGNAL ATTENTION GETTING 85 db BUZZER SPECIFICATIONS VOLTAGE INPUT: 12 VOLT AC, USE 20 VA TRANSFORMER INCLUDED STANDBY BATTERY: 12 VOLT 4AH RECHARGEABLE BATTERY INCLUDED POWER CONSUMPTION: ZAC-32 CONTROL 30MA., REMOTE ANNUNCIATOR 25MA.IN, 150MA. MAX. TOTAL OUTPUT CURRENT: NOT TO EXCEED 800MA. FROM ALL OUTPUTS ZONES: NORMALLY-OPEN, NORMALLY-CLOSED, SUPERVISED ZONE MODEL AVAILABLE ZONE LENGTH: 10,000 FEET 18 GA., 5000 FEET 20 GA., 2500 FEET 22 GA., 2 CONDUCTOR WIRE DESKTOP ANNUNCIATOR: CONECTED TO CABINET WITH 22 GA. SHEILDED 4 CONDUCTOR WIRE DESKTOP ANNUNCIATOR SIZE: 16.2 L x 8 W x 2.8 D CABINET SIZE: 13 H x 11.75 W x 3.5 D RACK MOUNTED ANNUNCIATOR: STANDARD 19 RACK, 8.75 W ALARM CONTROLS CORPORATION QUALITY SECURITY EQUIPMENT SINCE 1971 19 BRANDYWINE DRIVE, P.O. BOX 280, DEER PARK, NEW YORK 1 800 645-5538 631 586-4220 FAX 631 586-6500 EMAIL: INFO@ALARMCONTROLS.COM WWW.ALARMCONTROLS.COM

TABLE OF CONTENTS ZONE ANNUNCIATOR/CONTROLLER INSTALLATION INSTRUCTIONS SUBJECT PAGE INTRODUCTION 1 SYSTEM FEATURES 1 POWER REQUIREMENTS 2 AC POWER 2 STANDBY BATTERY 2 EARTH GROUND 2 ZONE INPUTS ZAC-32 2 ZONE INPUTS ZAC-32S 3 ZONE TERMINAL DESIGNATIONS 3 CONNECTING PROCESSOR TO PRINTER INTERFACE 4 AUXILIARY VOLTAGE OUTPUTS 4 EXTERNAL STATUS OUTPUTS 4 EXTERNAL STATUS DESCRIPTION 5 CONNECTING DISPLAY TO PROCESSOR 5 SPECIFICATIONS 6 FCC COMPLIANCE 7 WARRANTY 7

ZONE ANNUNCIATOR/ CONTROLLER MODEL ZAC-32 INSTALLATION INSTRUCTIONS I. INTRODUCTION THE ZAC-32 ZONE ANNUNCIATOR/ CONTROLLER IS A TWO COMPONENT SYSTEM COMPRISED OF A CENTRAL ZONE PROCESSOR AND A REMOTE DISPLAY/CONSOLE. THE SYSTEM PROVIDES TOTAL ZONE MONITORING AND CONTROL AT A FULL FEATURED REMOTE DISPLAY CONSOLE. THE SYSTEM IS CAPABLE OF ZONE EXPANSION IN THIRTY- TWO ZONE MULTIPLES, AN OPTIONAL REMOTE PRINTER PROVIDES A HARD COPY OF ALL ZONE ACTIVITY BY AN IDENTIFYING AUTHORIZED CODE NUMBER IN ADDITION TO TIME AND DATE. THE REMOTE CONSOLE THE REMOTE CONSOLE CONTROLS AND DISPLAYS ALL THIRTY-TWO ZONES. THE CONDITION OF EACH ZONE IS CLEARLY DISPLAYED ON THE FUNCTIONALLY DESIGNED CONSOLE. THE DIGITAL KEYPAD IS USED TO ALLOW AUTHORIZED PERSONNEL ACCESS TO THE SYSTEM BY AN IDENTIFYING ACCESS CODE AND TO PERFORM VARIOUS SYSTEM FUNCTIONS. ALL ZONE DATA AND ZONE CONTROL FUNCTIONS ARE TRANSMITTED TO THE ZONE PROCESSOR FROM THE REMOTE CONSOLE OVER A FOUR-CONDUCTOR CABLE. UP TO FOUR REMOTE CONSOLES CAN BE ADDED TO THE SYSTEM FOR ANNUNCIATION AND CONTROL AT MULTIPLE LOCATIONS. REMOTE CONSOLES CAN BE LOCATED IN EXCESS OF 1000 FEET FROM THE ZONE PROCESSOR. THE ZONE PROCESSOR CABINET THE ZONE PROCESSOR CABINET CONTAINS THE SYSTEM LOGIC CIRCUITRY, POWER SUPPLY AND STANDBY POWER SOURCE. ALL FIELD WIRING IS TERMINATED IN THE ZONE PROCESSOR CABINET. A FOUR CONDUCTROR CABLE CONNECTS THE ZONE PROCESSOR TO THE REMOTE CONSOLE. II. SYSTEM FEATURES 32 ZONES CAN BE WIRED NORMALLY- FOUR WIRE REMOTE ANNUNCIATOR OPEN OR NORMALLY-CLOSED DISPLAY CONSOLE UP TO FOUR REMOTE CONSOLES CAN BE ADDED TO A SYSTEM BUILT-IN AUDIBLE SIGNAL, 80 Db @ 3 FT. THIRTY-TWO ZONE STATUS INDICATORS OPTIONAL PRINTER FOR COMPLETE RECORD OF SYSTEM ACTIVITY OPTIONAL THIRTY-TWO ZONE VOLTAGE OUTPUT MODULE DIGITAL KEYPAD FOR SYSTEM SECURITY FOUR SYSTEM FUNCTION INDICATORS POWER FAILURE AND LOW BATTERY INDICATION OPTIONAL SUPERVISED ZONE MODULE OPTIONAL EIGHT ZONE RELAY MODULE SIXTEEN FOUR DIGIT ACCESS CODES COMMON ANNUNICATOR VOLTAGE OUPUT PAGE 1

II. POWER REQUIREMENTS A. AC POWER TERMINALS 11 & 12 CONNECT THE 12 VOLT 20 VA. UL LISTED PLUG-IN TRANSFORMER TO THESE TERMINALS. DO NOT CONNECT TO A RECEPTACLE CONTROLLED BY A SWITCH. CAUTION: TO REDUCE THE RISK OF ELECTRICAL SHOCK, DISCONNECT POWER TO RECEPTACLE BEFORE INSTALLING OR REMOVING THE TRANSFORMER. WHEN REMOVING THE RECEPTACLE COVER SCREW, COVER MAY FALL ACROSS PLUG PINS OR RECEPTACLE MAY BECOME DISPLACED. USE ONLY A DUPLEX RECEPTACLE HAVING A CENTER SCREW. SECURE TRANSFORMER IN PLACE WITH SCREW SUPPLIED. B. STANDBY BATTERY TERMINALS 9 (+) & 10 (-) CONNECT THE 12 VOLT RECHARGEABLE BATTERY, TO TERMINALS 9 AND 10 WITH THE BATTERY LEADS PROVIDED OBSERVING POLARTIY. CAUTION: BATTERY POLARITY MUST BE STRICTLY OBSERVED. IF BATTERY POLARITY IS REVERSED BATTERY FUSE WILL BLOW. REPLACE WITH CORRECT FUSE, (SOC SS2 3A), UNIT DOES NOT HAVE STANDBY POWER IF FUSE IS BLOWN. THE BATTERY FUSE IS LOCATED TO THE RIGHT OF TERMINAL 7 ON THE PRINTED CIRCUIT BOARD. C. EARTH GROUND THIS UNIT HAS EFFECTIVE LIGHTNING PROTECTION ONLY WHEN GROUNDED ACCORDING TO THE FOLLOWING INSTRUCTIONS: CONNECT TERMINAL 13 TO A METAL COLD WATER PIPE OR BURIED GROUND ROD WITH NOT LESS THEN 16 GA SOLID COPPER WIRE. CLEAN SURFACE OF METAL PIPE OR GROUND ROD AND SECURE WITH SUITABLE CLAMP. DO NOT GROUND TO A GAS PIPE. NOTE: IF THE ZONE PROCESSOR CIRCUIT BOARD IS REMOVED FROM THE CABINET ALL FOUR MOUNTING SCREWS MUST BE REPLACED TO INSURE PROPER GROUNDING TO AVOID LIGHTNING DAMAGE. IV. ZONE INPUTS (MODEL ZAC-32) THE ZONE PROCESSOR HAS 32 NON-SUPERVISED ZONE INPUTS WHICH CAN BE CONNECTED FOR NORMALLY-OPEN OR NORMALLY-CLOSED SWITCH CONTACT CONFIGURATIONS. A NORMALLY-OPEN ZONE INPUT REQUIRES A 10K OHM RESISTOR CONNECTED BETWEEN THE POSITIVE TERMINAL AND THE ZONE TERMINAL AS SHOWN. N/C ZONE TERMINALS N/O ZONE TERMINALS POS ZONE POS NEG ZONE +0 0 +0-0 0 N / 0 N/C CONTACT /\ /\ 10 K RES. PAGE 2

V. ZONE INPUTS (MODEL ZAC-32S) THE ZAC-32S ZONE PROCESSOR HAS 32 ZONE INPUTS WHICH ARE SUPERVISED WITH A 10K OHM END OF LINE RESISTOR. NORMALLY-CLOSED OR NORMALLY-OPEN SWITCH CONTACTS CAN BE CONNECTED TO THE SAME ZONE INPUT. ALL NORMALLY-OPEN DEVICES ARE CONNECTED IN PARALLEL AND ALL NORMALLY-CLOSED DEVICES ARE CONNECTED IN SERIES. THE END OF LINE RESISTOR IS CONNECTED IN SERIES WITH THE LAST NORMALLY- CLOSED DEVICE OR IN PARALLEL WITH THE LAST NORMALLY-OPEN DEVICE. NOTE: A SHORT OR OPEN IN A SUPERVISED ZONE WILL INDICATE A ZONE VIOLATION. N/O ZONE CONTACTS N/O & N/C ZONE N/C ZONE CONTACTS +POS ZONE +POS ZONE +POS ZONE 0 0 0 0 0 0 N/C N/0 N/O N/C CONTACT CONTACT CONTACT / \ / \ / \ / \ / \ / \ 10K RES. 10K RES. 10K RES. VI. ZONE TERMINAL DESIGNATIONS ZONE N/C N/O ZONE N/C N/O TERMINALS TERMINALS LOCATION TERMINALS TERMINALS LOCATION 1 19, 21 20, 21 17 43, 45 44, 45 2 19, 22 20, 22 18 43, 46 44, 46 3 19, 23 20, 23 19 43, 47 44, 47 4 19, 24 20, 24 20 43, 48 44, 48 5 25, 27 26, 27 21 49, 51 50, 51 6 25, 28 26, 28 22 49, 52 50, 52 7 25, 29 26, 29 23 49, 53 50, 53 8 25, 30 26, 30 24 49, 54 50, 54 9 31, 33 32, 33 25 55, 57 56, 57 10 31, 34 32, 34 26 55, 58 56, 58 11 31, 35 32, 35 27 55, 59 56, 59 12 31, 36 32, 36 28 55, 60 56, 60 13 37, 39 38, 39 29 61, 63 62, 63 14 37, 40 38, 40 30 61, 64 62, 64 15 37, 41 38, 41 31 61, 65 62, 65 16 37, 42 38, 42 32 61, 66 62, 66 PAGE 3

VII. CONNECTIONS TO ZAP-256 PRINTER INTERFACE, (SEE ZAP-256 INSTRUCTIONS FOR FURTHER DETAILS) ZONE ANNUNCIATOR TO PRINTER INTERFACE TERMINALS TERMINALS 1 (RED) 1 OR 6 (RED) 2 (GREEN) 2, 3, 4, 5, 7, 8, 9, 10 (GREEN) 3 (YELLOW) 11 OR 12 (YELLOW) 4 (BLACK) 13 OR 14 (BLACK) NOTE: THE RED WIRE FROM EACH ZONE ANNUNCIATOR MAY BE CONNECTED TO EITHER TERMINAL 1 OR 6 ON THE PRINTER INTERFACE. TERMINALS 1 AND 6 ARE INTERNALLY CONNECTED. DUAL TERMINALS ARE PROVIDED TO LIMIT THE NUMBER OF CONNECTIONS ON EACH TERMINAL. THE GREEN WIRE FROM EACH ZONE ANNUNCIATOR MAY BE CONNECTED TO EITHER TERMINAL 2,3,4,5,7,8,9,10 ON THE PRINTER INTERFACE. VIII. AUXILIARY VOLTAGE OUTPUTS 12 VOLTS DC THE ZONE ANNUNCIATOR HAS EIGHT SETS OF AUXILIARY VOLTAGE OUTPUT TERMINALS. EACH SET OF OUTPUT TERMINALS IS FUSED WITH A 500 MA., 5 MM FUSE, (ACC P/N SS2-5). THE MAXIMUM TOTAL CURRENT AVAILABLE FROM THESE OUTPUTS IS 700 MA. THIS TOTAL OF ALL OUTPUTS SHOULD NOT BE EXCEEDED. USE THE PROVIDED CHART TO TOTAL THE SUM OF THE OUTPUTS. VOLTAGE OUTPUT TERMINALS CURRENT USED 19 + & 20- MA. 25 + & 26- MA. 32 + & 32- MA. 37 + & 38- MA. 43 + & 44- MA. 49 + & 50- MA. 55 + & 56- MA. 61 + & 62- MA. TOTAL NOT TO EXCEED 700 MA. IX. EXTERNAL STATUS OUTPUTS THE ZONE ANNUNCIATOR HAS FOUR EXTERNAL STATUS OUTPUTS. THESE OUTPUTS WILL SUPPLY 10 VDC @ 28 MA. TO AN EXTERNAL DEVICE. THE EXTERNAL STATUS OUTPUTS SWITCH GROUND WHEN ACTIVE. THE OUTPUT MUST BE CONNECTED TO THE NEGATIVE SIDE OF THE DEVICE TO BE OPERATED. ALL EXTERNAL STATUS OUTPUTS CAN BE CONNECTED TOGETHER TO COMBINE FUNCTIONS. EXTERNAL STATUS OUTPUT ANNUNCIATE (ANN) BYPASS (BYP) LOW BATTERY (LBT) AC POWER FAILURE (PFL) TERMINALS 15 & ANY POSITIVE TERMINAL 16 & ANY POSITIVE TERMINAL 17 & ANY POSITIVE TERMINAL 18 & ANY POSITIVE TERMINAL PAGE 4

X. EXTERNAL STATUS OUTPUT DESCRIPTION ANNUNCIATE- WHEN ANY ZONE IS VIOLATED THE ANNUNCIATE OUPUT TURNS ON. WHEN THE AUDIBLE SIGNAL IS SILENCED THE ANNNICATE OUTPUT WILL TURN OFF. BYPASS- THE BYPASS OUTPUT WILL TURN ON WHEN ANY ZONE IS BYPASSED. THE BYPASS OUTPUT WILL TURN OFF WHEN ALL ZONES ARE UN-BYPASSED. THIS OUTPUT IS NOT AFFECTED BY THE USE OF THE DAY ZONE FEATURE. LOW BATTERY- WHEN A LOW BATTERY CONDITION IS DETECTED THE LOW BATTERY OUTPUT WILL TURN ON. THE OUTPUT WILL REMAIN ON UNTIL THE LOW BATTERY CONDITION IS CORRECTED. AC POWER FAILURE WHEN AC POWER FAILS THIS OUTPUT TURNS ON. THE OUTPUT WILL REMAIN ON UNTIL AC POWER IS RESTORED. XI. CONNECTING THE REMOTE DISPLAY CONSOLE TO THE ZONE PROCESSOR UP TO FOUR REMOTE CONSOLES CAN BE ADDED TO THE SYSTEM. EACH REMOTE CONSOLE IS POWERED FROM THE ZONE PROCESSOR. ALLOW 150 MA. FOR EACH REMOTE DISPLAY CONSOLE WHEN CALCULATING THE TOTAL CURRENT USED BY THE SYSTEM. THE REMOTE CONSOLE IS TERMINATED WITH AN EIGHT CONDUCTOR MODULAR CORD. AN EIGHT CONDUCTOR MODULAR JACK IS SUPPLIED TO TERMINATE THE CABLE RUN BETWEEN THE ZONE PROCESSOR AND THE REMOTE DISPLAY CONSOLE. A MINIMUM OF FOUR CONDUCTORS MUST BE USED. IF THE CABLE RUN BETWEEN THE ZONE PROCESSOR IS IN EXCESS OF 100 FEET; SHEILDED CABLE SHOULD BE USED. THE MAXIMUM CABLE RUN BETWEEN THE ZONE PROCESSOR AND THE REMOTE DISPLAY CONSOLE IS 1000 FEET. TWO CONDUCTORS OF THE MODULAR CORD CAN BE USED FOR A TAMPER CIRCUIT WHICH CAN BE CONNECTED TO THE N/C INPUT OF A CONVENTIONAL ALARM SYSTEM. THE USE OF THE TAMPER CIRCUIT REQUIRES A SIX CONDUCTOR SHEILED CABLE. IF SHEILDED CABLE IS USED, CONNECT TO THE GRAY AND BROWN TERMINAL ON THE MODULE JACK. REMOTE DISPLAY TO ZONE PROCESSOR JACK TERMINALS TERMINALS RED 5 GREEN 6 YELLOW 7 BLACK 8 GRAY & BROWN 13 TO SHEILD BLUE & ORANGE TAMPER CIRCUIT TO ALARM SYSTEM TAMPER INPUT NOTE: A RACK MOUNTED OR GRAPHIC DISPLAY IS CONNECTED USING THE SAME COLOR CODE AS THE REMOTE DISPLAY CONSOLE. PAGE 5

XII. SPECIFICATIONS POWER INPUT: 12 V.A.C., 20 VA., CLASS 2 PLUG-IN TRANSFORMER, (ACC P/N BE12V20) STANDBY: 12 VOLT, 4 A.H. RECHARGEABLE BATTERY, (YUASA P/N NP4-12) POWER CONSUMPTION ZAC-32 ZONE PROCESSOR: 30 MA. ZAR-32 REMOTE ANNUNCIATOR: 25 MA. MINIMUM, 150 MA. MAXIMUM POWER OUTPUT ANNUNCIATOR OUTPUT: 10 V.D.C. @ 28 MA. ZONE BYPASS OUTPUT: 10 V.D.C. @ 28 MA. LOW BATTERY OUTPUT: 10 V.D.C. @ 28 MA. POWER FAILURE OUTPUT: 10 V.D.C. @ 28 MA. AUXILIARY POWER OUTPUT: 10 V.D.C. @ 28 MA. NOTE: TOTAL CURRENT FROM ALL OUTPUTS NOT TO EXCEED 800 MA. FUSES BATTERY FUSE: 2.5 SB 3 AG AUXILIARY POWER FUSES: 5 x 20MM 500MA ZONE PARAMETERS LOOP RESPONSE TIME: 250 MS. TO ACTIVATE, 125 MS. TO RESTORE LOOP RESISTANCE: 10,000 OHMS MAXIMUM LOOP LENGTH: 10000 FEET WITH 18 AWG. 2 CONDUCTOR WIRE 5000 FEET WITH 20 AWG. 2 CONDUCTOR WIRE 2500 FEET WITH 22 AWG. 2 CONDUCTOR WIRE REMOTE ANNUNCIATOR PARAMETERS AUDIBLE SIGNAL: 80 DB @ 3 FEET WIRE TYPE: 22 AWG., 4 CONDUCTOR SHEILDED LENGTH: 1000 FEET MAXIMUM DIMENSIONS CONTROL CABINET: 13H x 11.75W x 3.5D DEST TOP CONSOLE: 16.2L x 8W x 2.8D RACK MOUNTED ANNUNCIATOR: STANDARD 19 INCH x 8.75 PAGE 6

FCC COMPLIANCE THIS EQUIPMENT GENERATES AND USES RADIO FREQUENCY ENERGY AND IF NOT INSTALLED AND USED PROPERLY, THAT IS IN STRICT ACCORDANCE WITH THE MANUFACTURER S INSTRUCTION, MAY CAUSE INTERFERENCE TO RADIO AND TELEVISION RECEPTION. IT HAS BEEN TYPE TESTED AND FOUND TO COMPLY WITH THE LIMITS FOR A CLASS B COMPUTING DEVICE IN ACCORDANCE WITH THE SPECIFICATIONS OF SUBPART J OF PART 15 OF FCC RULES, WHICH ARE DESIGNED TO PROVIDE REASONABLE PROTECTION AGAINST SUCH INTERFERENCE IN AN INSTALLATION. HOWEVER, THERE IS NO GUARANTEE THAT INTERFERENCE WILL NOT OCCUR IN A PARTICULAR INSTALLATION. IF THIS EQUIPMENT DOES CAUSE INTERFERENCE TO RADIO OR TELEVISION RECEPTION, WHICH CAN BE DETERMINED BY TURNING THE EQUIPMENT OFF AND ON. THE USER IS ENCOURAGED TO TRY TO CORRECT THE INTERFERENCE BY ONE OR MORE OF THE FOLLOWING MEASURES. 1. RE-ORIENT THE TV OR RADIO ANTENNA. 2. RELOCATE OR MOVE THE EQUIPMENT AWAY FROM THE RECEIVER. 3. PLUG THE TRANSFORMER FOR THE EQUIPMENT INTO A DIFFERENT OUTLET SO THAT THE RECEIVER AND THE EQUIPMENT ARE ON DIFFERENT BRANCH CIRCUITS. 4. IF NECESSARY, THE USER SHOULD CONSULT THE INSTALLER OR AN EXPERIENCED RADIO/ TELEVISION TECHNICAN FOR ADDITIONAL SUGGESTIONS. THE USER MAY FIND THE FOLLOWING BOOKLET PREPARED BY THE FEDERAL COMMUNICATION COMMISSION HELPFUL: HOW TO IDENTIFY AND RESOLVE RADIO/ TV INTERFERENCE PROBLEMS. THIS BOOKLET IS AVAILABLE FROM THE U.S. GOVERNMENT PRINTING OFFICE, WASHINGTON, DC 20402, STOCK #004-000-00345-4. WARRANTY THE EQUIPMENT MANUFACTURED BY ALARM CONTROLS CORPORATION IS GUARANTEED TO BE FREE FROM DEFECTS IN MATERIAL AND WORKMANSHIP UNDER NORMAL USE AND SERVICE WHEN INSTALLED IN ACCORDANCE WITH ALARM CONTROLS CORPORATION S INSTALLATION INSTRUCTIONS. ALARM CONTROLS CORPORATION, WARRANTS TO REPLACE OR REPAIR, FREE OF CHARGE, THE EQUIPMENT COVERED BY THE WARRANTY WHICH HAS BEEN RETURNED TO THE FACTORY, TRANSPORTATION CHARGES PREPAID, WITHIN TWELVE MONTHS FROM RECEIPT OF THE EQUIPMENT AT ORIGINAL DESTINATION, AND WHICH, IN THE SOLE JUDGEMENT OF ALARM CONTROLS CORPORATION IS DEFECTIVE IN MATERIAL AND WORKMANSHIP. ANY MISUSE, MODIFICATION, REWORK, OR ADJUSTMENT ON EQUIPMENT BY ANY PERSON OTHER THAN AN AUTHORIZED REPRESENTATIVE OF ALARM CONTROLS CORPORATION SHALL VOID THE WARRANTY. THIS WARRANTY IS LIMITED ONLY TO THOSE PRODUCTS MANUFACTURED BY ALARM CONTROLS CORPORATION. THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED, INCLUDING THE WARRANTY OF MERCHANTABILITY AND FITNESS FOR ANY PARTICULAR PURPOSE OR USE, AND IN NO EVENT SHALL ALARM CONTROLS CORPORATION BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES AS SAME ARE DEFINED IN THE UNIFORM COMMERCIAL CODE. PAGE 7

MODEL ZAC-32 OPERATING INSTRUCTIONS I. INTRODUCTION THE ZAC-32 ZONE ANNUNCIATOR/CONTROLLER IS A TWO COMPONENT SYSTEM COMPRISED OF A CENTRAL ZONE PROCESSOR AND A REMOTE DISPLAY CONSOLE. THE SYSTEM PROVIDES TOTAL ZONE MONITORING AND CONTROL AT THE FULL FEATURED REMOTE CONSOLE. THE SYSTEM IS CAPABLE OF ZONE EXPANSION IN THIRTY-TWO ZONE MULTIPLES. THE REMOTE CONSOLE CONTROLS AND DISPLAYS ALL THIRTY-TWO ZONES. THE CONDITION OF EACH ZONE IS CLEARLY DISPLAYED ON THE FUNCTIONALLY DESIGNED CONSOLE. A DIGITAL KEYPAD IS USED TO ALLOW AUTHORIZED PERSONEL ACCESS TO THE SYSTEM BY AN IDENTIFYING ACCESS CODE AND TO PERFORM VARIOUS SYSTEM FUNCTIONS. II. THE ZONE PROCESSOR THE ZAC-32 HAS 32 ZONES. EACH ZONE IS INDEPENDENT IN OPERATION. WHEN A ZONE IS VIOLATED THE ZONE INDICATOR AND THE AUDIBLE SIGNAL WILL TURN ON AND ZONE MEMORY WILL BE SET. IF THE VIOLATED ZONE IS RESTORED BEFORE IT IS ACKNOWLEDGED THE ZONE INDICATOR WILL REMAIN ON. THE ZONE PROCESSOR CONTAINS A POWER SUPPLY AND RECHARGEABLE BACK-UP BATTERY. THE AC POWER AND BATTERY ARE MONITORED FOR FAILURE. IF THE AC POWER IS INTERRUPTED OR THE BATTERY VOLTAGE DROPS BELOW A SAFE LEVEL THE SYSTEM INDICATORS AND AUDIBLE SIGNAL WILL REPORT THE TROUBLE CONDITION. WHEN AC POWER HAS BEEN RESTORED THE INDICATORS AND AUDIBLE SIGNAL WILL TURN OFF. III. THE REMOTE DISPLAY CONSOLE THE REMOTE CONSOLE DISPLAYS AND CONTROLS ZONE STATUS AND SYSTEM CONDITIONS. THE CONSOLE CONTAINS A DIGITAL KEYPAD, ZONE SYSTEM INDICATORS AND AN AUDIBLE SIGNAL.. A. DIGITAL KEYPAD - THE DIGITAL KEYPAD IS USED TO ACCESS AND CONTROL THE SYSTEM. B. ZONE ANNUNCIATION - THE ZONE INDICATORS DISPLAY COMPLETE ZONE STATUS. FLASHING - ZONE BYPASSED, OFF - ZONE SECURE OR IN A NON-VIOLATED CONDITION ON - ZONE VIOLATED OR IN ZONE MEMORY. C. SYSTEM INDICATORS - THE SYSTEM INDICATORS DISPLAY THE FOLLOWING INFORMATION. DAY MODE INDICATOR ON - ALL DAY ZONES ARE BYPASSED. ACCESS INDICATOR ON - A VALID CODE HAS BEEN ENTERED. LOW BATTERY INDICATOR ON - LOW BATTERY VOLTAGE HAS BEEN DETECTED. POWER FAILURE INDICATOR ON - AC POWER IS OFF. D. ANNUNCIATOR - AN AUDIBLE SIGNAL SOUNDS TO INDICATE A ZONE VIOLATION, SYSTEM TROUBLE OR WHEN A KEY IS PRESSED. IV. ZONE ANNUNCIATION/CONTROLLER SYSTEM OPERATION A. ACCESS CODE - A FOUR DIGIT ACCESS CODE MUST BE ENTERED BEFORE ANY FUNCTION CODE WILL BE ACCEPTED. ALL ACCESS CODES ARE PRESET AT THE FACTORY. A LIST OF ACCESS CODES IS INCLUDED WITH EACH UNIT. LISTED BELOW IS THE PROCEDURE FOR ENTERING AN ACCESS CODE. 1. LOAD A VALID FOUR DIGIT ACCESS CODE. PRESS EACH NUMBER OF THE CODE UNTIL A BEEP IS HEARD. 2. PRESS THE #,(POUND), KEY TO ENTER THE CODE. 3. ACCESS INDICATOR TURNS ON. NOTE: AFTER 60 SECONDS ACCESS IS AUTOMATICALLY TURNED OFF. B. FUNCTION CODES - THE ZONE ANNUNCIATOR/CONTROLLER HAS SIX FUNCTIONS. SYSTEM CONTROL CODE FUNCTION 1 ANNUNCIATION RESET 2 ZONE MEMORY RESET 3 DAY ZONE MODE 4 SYSTEM TEST PAGE 1

BYPASS CONTROL CODE FUNCTION 5 ZONE BYPASS ON 6 ZONE BYPASS OFF TO ENTER A SYSTEM CONTROL FUNCTION CODE 1. LOAD VALID FOUR DIGIT ACCESS CODE, THEN PRESS #,(POUND), KEY TO ENTER CODE 2. ENTER THE SELECTED FUNCTION CODE, THEN PRESS #,(POUND), KEY TO ENTER CODE TO ENTER A BYPASS CONTROL FUNCTION CODE 1. LOAD VALID FOUR DIGIT ACCESS CODE, THEN PRESS #,(POUND), KEY TO ENTER CODE 2. LOAD SELECTED BYPASS FUNCTION CODE, THEN PRESS,(STAR). KEY TO ENTER * 3. LOAD TWO DIGIT ZONE NUMBER,(01-32), THEN PRESS #,(POUND), KEY TO EXECUTE NOTE: ONLY ONE ZONE AT A TIME CAN BE BYPASSED OR UN-BYPASSED C. ANNUNCIATE RESET THE AUDIBLE ANNUNCIATOR WILL SOUND WHEN A ZONE HAS BEEN VIOLATED OR A SYSTEM TROUBLE SIGNAL IS DETECTED. NOTE: AFTER ACKNOWLEDGMENT OF THE ACTIVITY THE ANNUNCIATOR MUST BE RESET. TO RESET THE AUDIBLE ANNUNCIATOR 1. ENTER VALID FOUR DIGIT ACCESS CODE, THEN PRESS #,(POUND), KEY TO ENTER 2. PRESS KEY 1 3. PRESS #,(POUND), KEY TO EXECUTE THE AUDIBLE ANNUNCIATOR WILL BE SILENCED WHEN KEYS ARE PRESSED. IF THE AUDIBLE ANNUNCIATOR IS NOT RESET, THE AUDIBLE SIGNAL WILL SOUND AFTER THE LAST KEY IS PRESSED. D. MEMORY RESET WHEN A ZONE HAS BEEN VIOLATED THE ZONE MEMORY IS SET. IN ORDER TO MONITOR THE ZONE STATUS THE ZONE MEMORY MUST BE RESET. TO RESET THE ZONE MEMORY 1. ENTER A VALID FOUR DIGIT ACCESS CODE, THEN PRESS #,(POUND),KEY TO ENTER 2. PRESS KEY 2 3. PRESS #,(POUND), KEY TO EXECUTE THE ZONE MEMORY WILL RESET, THE ZONE INDICATOR WILL TURN OFF UNLESS THE ZONE IS STILL VIOLATED. E. DAY ZONE MODE THE DAY ZONE MODE IS ACTIVE WHEN THE DAY ZONE STATUS INDICATOR IS ON. ALL DESIGNATED DAY ZONES ARE BYPASSED WHEN THE DAY ZONE MODE IS ACTIVATED ALLOWING FREE ACCESS TO THOSE ZONES WITHOUT CAUSING A VIOLATION. TO ACTIVATE THE DAY ZONE MODE 1. ENTER VALID FOUR DIGIT ACCESS CODE, THEN PRESS #,(POUND), KEY TO ENTER 2. PRESS 3 KEY 3. PRESS #,(POUND), KEY TO EXECUTE IF DAY ZONE MODE WAS OFF DAY ZONE MODE WILL TURN ON. IF DAY ZONE MODE WAS ON DAY ZONE MODE WILL TURN OFF. NOTE: ALL DAY ZONES ARE BYPASSED WHEN THE DAY MODE IS ON. F. SYSTEM TEST IT IS RECOMMENDED THAT THE SYSTEM TEST BE OPERATED AT LEAST ONCE A WEEK TO CHECK ALL ZONE STATUS, SYSTEM INDICATORS AND STAND-BY BATTERY CONDITION. PAGE 2

TO OPERATE SYSTEM TEST 1. ENTER A VALID FOUR DIGIT ACCESS CODE, THEN PRESS #,(POUND),KEY TO ENTER 2. PRESS KEY 4 3. PRESS #,(POUND), KEY TO EXECUTE ALL ZONE AND SYSTEM INDICATORS WILL TURN ON. AC POWER WILL BE DISCONNECTED AND THE AUDIBLE SIGNAL WILL SOUND. NOTE: IF A ZONE IS VIOLATED DURING THE TEST PERIOD THE TEST IS ABORTED AND NORMAL OPERATION RESUMES. IF A LOW BATTERY IS DETECTED DURING THE TEST ALL INDICATORS ARE RESTORED TO NORMAL. LOW BATTERY WILL STILL BE INDICATED UNTIL THE TEST IS COMPLETED, THEN AC POWER AND BATTERY VOLTAGE RESTORES. G. BYPASS CONTROL IF A PROBLEM DEVELOPS IN A ZONE OR FREE ACCESS IS DESIRED THE ZONE MUST BE BYPASSED. THE FOLLOWING IS AN EXAMPLE OF THE ZONE BYPASS FUNCTION: TO BYPASS ZONE NUMBER 2 1. LOAD A VALID FOUR DIGIT ACCESS CODE THEN PRESS #,(POUND), KEY TO ENTER 2. PRESS KEY 5 THEN PRESS,(STAR), KEY TO ENTER * 3. ENTER A ZONE NUMBER 02 THEN PRESS #,(POUND), KEY TO EXECUTE ZONE 2 INDICATOR WILL FLASH, BYPASS STATUS OUTPUT WILL TURN ON THE FOLLOWING IS AN EXAMPLE OF THE ZONE UN- BYPASS FUNCTION: TO UN-BYPASS ZONE NUMBER 30 1. LOAD A VALID FOUR DIGIT ACCESS CODE THEN PRESS #,(POUND), KEY TO ENTER 2. PRESS KEY 6 THEN PRESS,(STAR), KEY TO ENTER * 3.ENTER A ZONE NUMBER 30 THEN PRESS #,(POUND), KEY TO EXECUTE ZONE 30 INDICATOR WILL DISPLAY ZONE OR MEMORY STATUS, BYPASS STATUS OUTPUT WILL TURN OFF H. ZONE VIOLATION WHEN A ZONE VIOLATION IS REPORTED DO THE FOLLOWING: 1. ENTER A VALID FOUR DIGIT ACCESS CODE 2. RESET AUDIBLE SIGNAL 3. ACKNOWLEDGE ZONE INDICATOR FOR LOCATION 4. RESET ZONE MEMORY TO INDICATE ZONE STATUS I. POWER FAILURE WHEN AC POWER FAILURE IS DETECTED DO THE FOLLOWING: 1. ENTER A VALID FOUR DIGIT ACCESS CODE 2. RESET AUDIBLE ANNUNCIATOR 3. ACKNOWLEDGE POWER FAILURE INDICATOR 4.CHECK AC POWER ALL INDICATORS ARE RESTORED TO NORMAL. J.LOW BATTERY WHEN A LOW BATTERY IS DETECTED DO THE FOLLOWING: 1. ENTER A VALID FOUR DIGIT ACCESS CODE 2. RESET AUDIBLE ANNUNCIATOR 3. ACKNOWLEDGE LOW BATTERY INDICATOR 4.CHECK STANDBY BATTERY ALL INDICATORS ARE RESTORED TO NORMAL. PAGE 3

ZAC-32 PROGRAMMED INFORMATION A. ACCESS CODES PROM # 111 ACCESS ID NUMBER ACCESS CODE 01 1865 02 9506 03 5198 04 7357 05 9274 06 4742 07 2645 08 2405 09 7928 10 9258 11 8296 12 8320 13 9078 14 9536 15 8878 16 4530 B. ZONE DESIGNATIONS STANDARD ZONES # 1-24 DAY ZONES # 25-32 ALARM CONTROLS CORPORATION 19 BRANDYWINE DRIVE DEER PARK, NY 11729 631 586-4220 800 645-5538