systemate 2000 fully integrated thermal store

Similar documents
BOILERMATE 2000 USER-GUIDE SWITCH. TEL: Gas Council Approved Reference Numbers

BOILERMATE A CLASS OV

BOILERMATE A CLASS SP

PULSACOIL 2000 ELECTRIC THERMAL STORE USER INSTRUCTIONS

PULSACOIL 2000 USER GUIDE. TEL:

PULSACOIL A CLASS USER GUIDE. TEL:

i 24, i 30, i 35 combination boilers USER GUIDE For Installation Guide see reverse of book UIN A05 October 2017

Baxi Combi 133 HE Plus Baxi Combi 100 HE Plus Baxi Combi 80 HE Plus. User s Operating Instructions

ADVANCE ECB ELECTRIC COMBINATION BOILER

The iqe Boiler Range. Combination and System T Boilers.

USER GUIDE VOGUE COMBI GEN2 C26 C32 C40

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

USERS GUIDE 24, 30. For installation guide see reverse of book

Ultracom cxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r.

USER GUIDE VOGUE MAX SYSTEM

Operating instructions Oil condensing boiler

USERS GUIDE. Esprit eco 24, 30. For installation guide see reverse of book

Logic+ Combi

USER GUIDE LOGIC HEAT H

TORRENT ECO ONE NAME. EVERY SOLUTION. OPEN VENTED THERMAL STORE PROVIDING HEATING AND MAINS PRESSURE HOT WATER

Baxi System 100 HE Plus. User s Operating Instructions. Wall Mounted Powered Flue Condensing Gas Fired Central Heating Boiler

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

GB24 & GB30. User Manual

User's Instructions. Alpha CB50

User's Instructions. Alpha CD25X/28X. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers

Mains Pressure Hot Water from an existing vented copper cylinder... Allows the cold water tank to be removed, freeing loft space.

Baxi Maxflow Combi WM

iheat 25c iheat 30c iheat 35c

AN ENERGY SAVING ADDITIVE FOR CENTRAL HEATING SYSTEMS

ALKON CARGO. A precise and fast delivery rate. A very high specific flow rate (20 litres per minute with Dt 25)

MURELLE EV HE 25/55-30/55

USERS GUIDE. LOGIC+ Combi 24, 30, 35

System s30. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS SYSTEM BOILER

Baxi Maxflow Combi FS

condens Instructions for Use Betacom 2 24 G.C. No Betacom 2 28 G.C. No

Baxi Megaflo System HE IE Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Boiler

Cylinder Manual. Open Vented Cylinders Stainless Steel Water Heaters. Twin Coil TW180V TW210V TW250V TW300V Triple Coil TR250V TR300V

GREENSTAR HIGHFLOW 440/550CDi

Baxi Combi 80Eco. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

Instructions for Use Installation and Servicing

HEATRAE SADIA. Installation and User Instructions for the UTC Undersink Vented Water Heater

High Output Boiler Systems

Baxi Bahama 100. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

Combi C30 & C35. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

British Gas 330+ High Efficiency Condensing Boiler. Instructions for Use. To b e l e f t w i t h t h e u s e r. British Gas Service Tel:

VIESMANN. Operating instructions VITODENS 111-W. for the system user

Torrent ECO. The final piece in your heating and hot water system. Open vented thermal store providing heating and mains pressure hot water

Synergy3 Owner s Manual. Owner s Manual. Geothermal Heating Cooling Hot Water

The guarantee on this appliance is valid for 12 months from the first day of installation.

Greenstar 25Si/30Si USER INSTRUCTIONS & CUSTOMER CARE GUIDE

Osprey 2 CFL

Saving Energy. We promote equality of opportunity in every aspect of our business in line with our objectives.

OIL FILLED RADIATOR Instruction manual

Efficiency Maximiser for Solid Fuel Central Heating

Vote for your Installer of the year at HEATSLAVE

ST9400A User Guide. Features

Underfloor heating. user guide. DS thermostats with timeclock. Nu-Heat v18 UNDERFLOOR HEATING HEAT PUMPS SOLAR THERMAL

For the owner. Operating manual. ecotec plus 937. Gas condensing storage combination boiler VUI

Performa 24. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

Modern Central Heating Contents

heat interface units A BOILER WITHOUT A FLAME

Table of Contents. Model: Series. Available in : Sapphire Black and Glacier White. Product Image. 20 Table of Contents.

E-COMBI EVO E-SYSTEM EVO

GREENSTAR CAMRAY UTILITY & UTILITY SYSTEM

Combi Eco Elite Range. User s Guide and Important Warranty Information

FORMAT DGT HE. User instructions. Please read the Important Notice within this guide regarding your boiler warranty

ST9400S User Guide. 1 Day Programmer, 2 channel With Boiler Service Reminder / Shut-down Feature

HHIC consumer guide to gas boiler servicing

CT range. of shower, bathroom and whole house pumps

SUPPLEMENT. Part No. DOC 25 Rev. 09 November SUPPLEMENTARY INSTALLATION and USER INSTRUCTIONS. COMBI 90 OUTDOOR MODULE MkII

YourRepair Home & Boiler Cover

SEDBUK Band A Gas Condensing Boilers. The Greenstar range of high efficiency gas condensing boilers from Worcester

MEGAFLO HE Iss 1

Combi Konverter Solar System

Installation and User Instructions HS10U, HS15U.

User Guide and Important Warranty Information. Suprima HE. Condensing Central Heating Boiler. Please read this document and keep it safe.

New Zealand Sales Hotline: Sales Fax:

User's Instructions. Alpha CD24C/32C. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers

GENERAL FITTING GUIDE THERMOSTATIC BAR SHOWER MIXER with RIGID RISER KIT

EFG ENERGY OPTIMISING SYSTEMS

Total Hot Water Solutions

Cistern-fed water heating

DOMESTIC HEATING CONTROLS ARE EASY PART 1 - THE BASICS

5 YEAR GUARANTEE. Inovia. High efficiency condensing combi and system boilers

EnergyMasterHP. user guide. Cylinder for use with NIBE heat pump systems. v12 Nu-Heat 2017 UNDERFLOOR HEATING HEAT PUMPS SOLAR THERMAL

Helping you understand your water usage

Risk Assessment and Control Measures for Household Hot Water Systems

Grant Vortex. Boiler House Floor Standing Condensing Oil Boiler Range User Handbook. Model shown: VTXBH3646

Ultracom 2. sxi. Instructions for Use. 12sxi. 18sxi. 30sxi. High Efficiency Condensing System Boilers. To be left with the user. G.C. No.

Table of Contents. Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure

GREENSTAR HIGHFLOW 440/550CDi

TABLE OF CONTENTS TECHNICAL DOCUMENTATION 03. Technical Data Electrical Details Connection Details Dimensions Standing Losses

Domestic Green Deal Advice Training

USER INSTRUCTIONS & CUSTOMER CARE GUIDE Si II SERIES

AquaNova. Water heater. Users Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

Greenstar 24i junior / 28i junior

OPERATION MANUAL. Daikin Altherma indoor unit EKHVMRD50ABV1 EKHVMRD80ABV1 EKHVMYD50ABV1 EKHVMYD80ABV1

Transcription:

systemate 2000 fully integrated thermal store user instructions In the interest of continuously improving the SysteMate 2000 range. Gledhill Water Storage Ltd reserve the right to modify the product without notice and in these circumstances this booklet which is accurate at the time of printing should be disregarded. benchmark TM The code of practice for the installation, commissioning & servicing of central heating systems Gledhill Guarantees the water storage vessel and components for material and construction faults for 2 years. This period is calculated from the date of purchase. WARNING There are no user adjustable parts inside the appliance. Tampering with sealed components will invalidate warranty and could also damage the appliance and make it unsafe to use. If it is known or suspected that a fault condition exists on the appliance it must be corrected by a competent person. DON T place any clothing or other combustible materials against or on top of this appliance.

Issue 2: September 2003 WELCOME TO YOUR THERMAL STORAGE SYSTEM SYSTEMATE 2000 - THE POWER BEHIND YOUR DOMESTIC HOT WATER AND CENTRAL HEATING The hot water and central heating in your home is provided by a high specification storage system which will give you many benefits. Simple to operate and exceptionally efficient in operation, your SysteMate 2000 Thermal Store is probably different to any water heating system you have ever experienced before. This booklet will explain why and how you can get the most from it. One of the most technologically advanced water heating and storage systems available, your Gledhill SysteMate 2000 is designed to fulfil four basic needs : 1. Deliver lots of hot water at good pressures whenever you need it 2. Provide rapid heat up of your property whenever you switch your heating on 3. Supply heating and hot water more cheaply than conventional systems 4. Provide hot water to every tap that has not deteriorated in storage tanks Page 2

1. DELIVER LOTS OF HOT WATER AT GOOD PRESSURES WHENEVER YOU NEED IT Your Thermal Storage System is designed to provide all the hot water you are likely to need under normal circumstances, and deliver that hot water at a pressure comparable with your cold water mains. That means you can enjoy powerful showers without the need for a separate pump, or fill a bath with hot water in minutes. 2. PROVIDE RAPID HEAT UP OF YOUR PROPERTY WHENEVER YOU SWITCH YOUR HEATING ON The highly efficient Thermal Storage System also means that your central heating will warm your house far more rapidly than a conventional system, with all your radiators reaching their efficient heating level in just a few minutes. 3. SUPPLY HEATING AND HOT WATER MORE CHEAPLY THAN CONVENTIONAL SYSTEMS Your Thermal Storage System will ensure that your boiler operates more efficiently by eliminating unnecessary firing and costly use of fuel. Page Because your boiler will operate in concert with the Gledhill SysteMate 2000, it remains in the on position 24 hours a day, 7 days a week, but fires only when needed to maintain the optimum temperature within your efficient Gledhill Thermal Store. The boiler must be left at its maximum temperature setting for the system to operate efficiently. SYSTEmate user instructions

Traditional System Your central heating still works on a timer which is fitted to your Thermal Store and thermostats control your room temperatures. Hot water will be available any time you need it when the system is switched on, summer and winter. But instead of your boiler operation determining when you get hot water and heating, your needs for hot water and heating will determine when your boiler operates. 4. PROVIDING HOT WATER THAT HAS NOT DETERIORATED IN STORAGE TANKS, TO EVERY TAP The SysteMate 2000 is connected directly to the cold mains and, therefore, even the hot supply is pure potable water every time. Page 4

WHAT IS A THERMAL STORE? The Gledhill Thermal Store is the heart and brain of your central heating system. It stores hot water at a constant temperature and incorporates a highly efficient plate heat exchanger which heats the hot water for all your domestic needs. The Thermal Store is superbly insulated and so the hot water stored has a very low heat loss. It also incorporates an intelligent sensor which determines when the temperature drops below a pre-set level required for optimum efficiency. When that temperature drop is detected, the Thermal Store instructs your domestic boiler to fire, generating the additional hot water needed to top up the store temperature. When the required temperature is reached, the boiler stops firing, until the next time it is required. WHY IS THE BOILER CONSTANTLY SWITCHED TO THE ON POSITION Page The system operates most efficiently if the boiler is always left on, with the boiler thermostat always at its maximum setting - even in summer. This is because the intelligent electronics within the Thermal Store control the system temperature automatically, based on demand. Your system should, generally, be left on at all times. If you are away for a short period, the room thermostat can be set to a low level just to prevent frost damage to your domestic pipework systems. SYSTEmate user instructions

HOW DOES THE SYSTEM DELIVER WATER AT HIGH PRESSURE The water to the taps and showers in your home is delivered at high pressure because it uses the mains pressure of your cold water supply. The SysteMate 2000 is connected to the mains system and the water passes through a highly efficient heat exchanger to raise its temperature before it travels to your taps and showers. Because it is so efficient, both high flow rates and high pressures are available to give the best performance for both baths and showers. Water cisterns are required for the traditional domestic hot water system, and are generally located in the loft, to give a better head of water. In most cases, the higher the cistern, the greater the pressure. WHY ARE THERE NO WATER CISTERNS IN THE LOFT? Because the Gledhill system uses the pressure from your cold water mains, these cisterns are not required, which removes any worries about freezing or contamination of the cold water system from insects, dust, birds, etc and leaves more space for storage should you decide to use it. However the SysteMate is fitted with its own feed and expansion cistern which is filled manually when the appliance is first installed. It is beneficial to check and if necessary top up the water in this cistern during the annual boiler service / if the appliance is not producing hot water. PLASTIC TOP UP CISTERN The plastic top up-cistern should have been filled to the water line by the installer at the time of commissioning. This should last many years if the lid has been securely replaced. Top up water can be added should this ever be necessary. Page

CONTROLLING YOUR SYSTEMATE 2000 Your SysteMate 2000 is a highly advanced Thermal Storage System which incorporates the latest in microprocessor technology to monitior your system automatically and ensure it operates at maximum efficiency. This includes periodically spinning the heating pump to prevent seizing during prolonged unused heating periods. In normal circumstances, you should only be required to adjust the time clock on your Thermal Store, to suit your needs, and the instructions for this are described in detail on the label fitted to the appliance. Page 7 The SysteMate is only one part of the sealed heating and mains pressure hot water systems fitted in your property. If your hot water or heating system should fail to operate satisfactorily, you will also need to refer to the information provided with the central heating boiler. If the fault is with the SysteMate appliance you will need to call a service engineer, who can then contact Gledhill Technical Department for any advice he may need or operate the SWITCH option which is fitted to your SysteMate 2000 (see Switch at the back of this booklet). However, because your SysteMate is part of a sealed heating system it may be that the fault lies elsewhere in the system or that the heating system only needs repressurising using the equipment provided adjacent to the boiler. As detailed previously, the Thermal Store controls the temperature of the system. In order to ensure your system operates at its most efficient the boiler thermostat should always be left at maximum. SYSTEmate user instructions

RESETTING THE HEATING PROGRAMME CLOCK Hot water is not time controlled and is available at all times, but you control the time your central heating switches on and off with the timer on your Gledhill Thermal Store. Separate instructions for this will have been left for you by the installation engineer, or you can refer to the instructions on the label on the front of the appliance. Page

U S I N G T H E U N I Q U E S W I TC H EMERGENCY ELECTRICAL BACK-UP SYSTEM Your SysteMate 2000 is fitted with Gledhill s unique SWITCH emergency electrical back-up system. You have an instant fail safe should your boiler cease to operate. The SWITCH system will be clearly displayed on the front of your Thermal Store Appliance. In the event of a boiler failure, the SWITCH technology simply and instantly introduces an electric heating source within the Thermal Store to ensure that your hot water and heating continue to operate until you can have your boiler repaired. Care should be taken when your SysteMate 2000 is operating under SWITCH conditions as the hot water temperature will be higher than in its normal operating condition. Operation of SWITCH is simple, just click to position 1 if you need hot water only or position 2 for hot water and heating and turn back to position zero once your boiler is repaired. Page SWITCH is only designed for emergency use and you will need to call a service engineer once you have operated SWITCH. SYSTEmate user instructions