Energedry Elite 52K. Operations Manual. Pest Control Electric Heat System. For Professional use only. EPA EST. No AZ-001

Similar documents
Energedry Elite Eliminator Pest Control Electric Heat System

Energedry Eliminator 52K

Radial 8 Heater For Professional use only

Energedry Eliminator. Operations Manual. Electric Heat Drying System. K & J Representatives, LLC Fax

Phoenix AirMAX - Radial Air Mover

Quest Power Electric Heat EHS 62 Pro

Owner s Manual Phoenix FireBird

Quest Power Electric Heat EHS 31 Pro

OmniDry 2.9 Amp Centrifugal Air Mover

Owner s Manual Hydro-X Vacuum Pac

Quest PowerHeat HFC 100 Pro

INSTALLER S & OWNER S MANUAL

Quest Dry 150 Dual. quest Asset Protection and IAQ Solutions. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

Owner s Manual Phoenix Aquadry TX 200

INSTALLER S & OWNER S MANUAL

Quest Dry. Quest 110 Dual. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

Quest Dry 105, 155, and 205 Dual

GALE FORCE VAF-16R. Ventilation Manual

Quest 105, Dry155, and 205 Dual

Quest CDG Dry 74. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

ELECTRIC FIREPLACE OWNER S MANUAL

Zeus Extreme Owner's Manual

Owner s Manual Ultimate 340

HAMILTON ELECTRIC STOVE HEATER MODEL EF-BLT01 / EF-BLT04 / EF-BLT07 / EF-BLT08 OPERATION MANUAL

36 IN. ELECTIC FIREPLACE FMI MODEL # LEF36 Mounting Base Feet and Wall Mounting Bracket Included

ELECTRIC FLAT PANEL FIREPLACE HEATER

GETZ MANUFACTURING PART # CYLINDER DRYER

Owner s Manual Phoenix 250 MAX

DRY 150 Quest PowerDry 1300

WALL MOUNT ELECTRIC FIREPLACE OWNERS MANUAL

OWNER S MANUAL PLEASE READ AND SAVE THESE INSTRUCTIONS WHOLE ROOM RADIATOR HEATER. Model: HO-0221 THERMOSTAT

20" Air Circulator MODEL: FB50-9HA

e Bath Fan with Light User s Guide

ELECTRIC STOVE MODEL CGESS SAFETY INFORMATION AND OPERATION MANUAL

e Heater/Exhaust Fan/Light User s Guide

READ AND SAVE THESE INSTRUCTIONS

Owner s Manual Phoenix 200HT

Concept S-2. Indoor Infrared Stove Heater. RedCore Stove Heater

High-Velocity Floor Fan

e Bath Fan with Light User s Guide

OPERATION MANUAL AND WARRANTY ELECTRONIC INFRARED ZONE HEATING SYSTEM

e Bath Fan with Light User s Guide

ELECTRIC STOVE HEATER Models: FS2213B

Instruction Leaflet. Heater with Adjustable Thermostat PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS

Quest DRY quest. Read and Save These Instructions. Installation, Operation and Maintenance Instructions. Quest DRY 180:

MaxLite LED Round Pendant Highbay Series

User s Manual & Operating Instructions

Professional Warming Drawer and Warming Drawer Cabinet

FLCH4R Garage and Utility Electric Heater

Cleanshield HEPA 550 Owner's Manual

Owner s Manual Phoenix Arctic Max

SFH136-CN TRUSTED FOR OVER 100 YEARS. Sunbeam Heater. Instruction Leaflet PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS

PORTABLE AIR CONDITIONER OWNER S MANUAL

MODEL HBX-1 P/N 3G59332

IMPORTANT SAFETY INFORMATION:

A2Z Ozone, Inc. PRODUCT MANUAL

IMPORTANT SAFETY INFORMATION:

Stand Fan. English. Owner s Guide. Model F R

MaxLite LED Vapor Tight Linear Fixture

Operation and warranty Manual

PRACTICAL USER S GUIDE FOR THE ELECTRIC STOVE

4201 Lien Rd. Madison, WI Owner s Manual Phoenix R250 LGR Dehumidifier. Installation, Operation & Service Instructions

1 HP Air Mover. Owner s Manual

READ MANUAL BEFORE OPERATING SYSTEM Read the owner s manual thoroughly before operating to ensure the most efficient use of the system.

Installation Guide. Manufactured for Aero-Spa, LLC Web:

60In. Ceiling Fan. Owner s Manual

PORTABLE AIR CONDITIONER OWNER S MANUAL

Owner s Manual HI-E Dry Vehere

Installation Manual. THM-0100 Setpoint Thermostat Version THM HBX Control Systems Inc.

IMPORTANT SAFETY INFORMATION:

Owner s Manual Phoenix 250 MAX

Instruction Manual and Warranty

22In. Oscillating Pedestal Fan. Owner s Manual

BLT-999W-2 Item # 60757

4201 Lien Rd. Madison, WI Owner s Manual Phoenix R175 LGR Dehumidifier. Installation, Operation & Service Instructions

ELECTRIC FIREPLACE INSTRUCTION MANUAL. Item No: 050-HA Model No. FP405R-QA

SYSTEM CONTROL KIT Model: CK-41P

PRACTICAL USER S GUIDE FOR THE SUB-COMPACT STOVE MODEL NUMBER: CS1205

ELECTRIC FIREPLACE INSERT MODEL EF-BLT10 OWNER S MANUAL

MULTI-FUNCTION HAND VACUUM INSTRUCTION MANUAL. For Authentic Monster Replacement Parts Call Model #: H056

IAQ Series. Bosch IAQ Photo Catalytic Oxidizer (PCO) Residential Application. Installation Manual and Owner s Guide

PRACTICAL USER S GUIDE FOR THE contempra ef STOVE

Lubi Submersible Condensate Removal Pumps

WA A Aqua Sub Bottom-load Water Cooler

BIONAIRE HEATER. Instruction Leaflet. pure indoor living MODEL: BCH4130. Read instructions before operating. Retain for future reference.

4201 Lien Rd. Madison, WI Owner s Manual Phoenix R200 LGR Dehumidifier. Installation, Operation & Service Instructions

IMPORTANT SAFEGUARDS IMPORTANT INSTRUCTIONS DIGITAL LOW PROFILE HEATER READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

With Remote Control. English

OWNER S MANUAL ELECTRIC FIREPLACE INSERT. Model No.: WESTERN (EF42D-45D) WARNING CAUTION

OWNER S MANUAL. FLAT PANEL FIREPLACE HEATER Model Number: Serena (EF202A) WARNING CAUTION

IMPORTANT SAFEGUARDS IMPORTANT INSTRUCTIONS DIGITAL CERAMIC HEATER READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

USE & CARE INSTRUCTIONS 10- SPEED HAND MIXER FSHM100

Enspeco RMS. The Enspeco Refrigerant Management. The following instructions will INSTRUCTIONS

MANUAL 8/12/05. Model BKP TM 100 INSTALLATION, OPERATION & MAINTENANCE. Commercial High Efficiency Heat Pipe Dehumidifier

Instruction Manual. MODEL: FD1603 POWER SUPPLY: VAC, 60Hz or VAC, 50Hz POWER CONSUMPTION: 250W

Description of the vacuum

Service Manual Models CPH2 & CPH3

IMPORTANT SAFETY INFORMATION:

READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

HANDY/STICK 2-WAY VACUUM INSTRUCTION MANUAL. For Authentic Monster Replacement Parts Call Model #: H055

Transcription:

Energedry Elite 52K Pest Control Electric Heat System For Professional use only Operations Manual EPA EST. No. 086342-AZ-001

DRI Heat Ph: 877-432-8601 Fax: 215-586-2405 Energedry Elite 52K Safety Page Read this owner s manual carefully before using your Eliminator Caution: Always use a licensed electrician when connecting your 52K Commercial buildings can have more than one ground. Have an electrician inspect and advise on setting up the 52K in commercial buildings. Never connect the fan or heater elements to different grounds. Never use the Elite 52K conditions exceeding 140F degrees. Never set the Thermostat control to higher than 140F degrees. Always check building circuits for proper grounding before plugging in your Eliminator. Never drop or bounce the Elite 52K. Internal damage may occur. Never clean or service the Elite 52K while plugged into a live electrical power source. Never operate the Elite 52K in standing water. Always wear rubber gloves and boots when operating the Eliminator in damp conditions. Never operate the Elite 52K unless all panels and guards are in place and properly secured.

Always keep the air inlet & outlet clear of any obstructions and loose material. Never operate the Elite 52K without the fan on. Never operate the Elite 52K with loose cord connection or damaged power cord(s). Never connect power from different buildings to the Eliminator. Warning: Ignoring these safety precautions may result in personal injury. DRI Heat Ph: 877-432-8601 K & J Representatives, LLC 2 Year Limited Warranty For Professional use only Warrantor: K & J Representatives, LLC, 6550 E. 6 th St., Ste C, Prescott Valley, AZ 86314. Telephone: 602-723-2534, Fax: 928-277-8123 Who is Covered: This warranty extends to the original end-user and may not be assigned or transferred. Warranty Period: The term of the warranty coverage from the date of purchase is: 1 years on the housing 1 year on parts and labor Warranty Coverage: K & J Representatives, LLC warrants that, for one (1) year, the Eliminator 52K manufactured by K & J Representatives, LLC will operate free from defects in material or workmanship, or K & J Representatives, LLC, at its option, will repair or replace the defective part(s), free of charge. K & J Representatives, LLC further warrants that for a period of two (2) years, the housing of the Eliminator 52K manufactured by K & J Representatives, LLC will be free from defects in material or workmanship, K & J Representatives, LLC will repair or replace the defective part(s), providing that all labor and shipping costs for the defective part(s) shall be borne by the enduser. This warranty does not cover any defect, malfunction, etc resulting from improper operation, lack of maintenance, freezing, corrosion from chemicals, condensation, tampering, modification,

unauthorized or improper repair, accident, acts of nature, shipping after you receive the Eliminator 52K, or normal wear to items such as power cords, plug adaptors or other items which require replacement resulting from normal usage. End-User Responsibilities: Warranty service must be performed by a firm or Individual authorized by K & J Representatives, LLC. The end-user must contact K & J Representatives, LLC at the above location. K & J Representatives, LLC will arrange for covered warranty service. All covered warranty service will be arranged during normal business hours. Limitations and Exclusions: If any part of the Elite 52K manufactured by K & J Representatives, LLC is repaired or replaced as covered warranty, the new part shall be warranted only for the remainder of the original warranty period of the Elite 52K. Upon expiration of the written warranty applicable to the K & J Representatives, LLC Eliminator 52K or any part thereof, all other warranties implied by law, including merchantability and fitness for a particular purpose, shall also expire. All warranties made by K & J Representatives, LLC are set forth herein, and no claim may be made against K & J Representatives, LLC on any oral warranty. In no event shall K & J Representatives, LLC, in connection with the sale, operation, repair or replacement of any K & J Representatives, LLC device or part thereof be liable under any legal theory for any special, indirect or consequential damages including without limitation water damage, lost profits, delay, or loss of use or damage to any real or personal property. Legal Rights: This warranty gives you specific legal rights, and you may also have other rights which vary from State to State. Energedry Elite 52K Operating Your Elite 52K Unpack & inspect your Elite 52K for damage Do not use if damaged. Check all heating elements to make sure everything works and nothing was damaged from shipping. If damaged from shipping do not use and contact us immediately at 602-723-2534. Your Elite 52K has one (1) cord for the fan that operates at 1.8 amps using only 120 volt. This is wrapped around the unit. There are two (2) 240 volt plug-ins for the heat elements located one per side on the Elite 52K. One (1) heating element is 24 amps at 240 volt and you need a minimum circuit of 30 amps at 240 volt to operate this heating element. #10 gauge cable can be used up to fifty (50). The other plug-in is a heating element that is 40 amps at 240 volt and you need a minimum circuit of 50 amps at 240 volt to

operate this heating element. #8 gauge cable can be used for this heating element up to fifty (50) feet. Running longer power cords will require larger gauge cable. You must have the cord that controls the fan plugged in or the unit will not operate. None of the heating elements will turn on if the fan is not on. If you block the inlet or the outlet of the unit, the heating elements will shut-off or will not turn on. This safety feature insures that proper minimum airflow must be maintained so the heating elements do not overheat.

Temperature Controller Temperature Controllers Your Elite 52K comes with a state of the art digital temperature controllers built into the unit. There are 3 temperature controller. One 50amp and one 30 amp. The view panel is on the top of the Elite 52K and will allow you to adjust the temperature controller. The controllers are preset to 132F and requires no need for adjustment to use your Elite 52K unless you want to change the temperature settings. To change the temperature setting; press the set button and then use the up and down arrows to set your desired temperature. The controller is set so you cannot turn the high temperature setting above 140F. Elite 52K Amps/Watts/Voltage Description Amps Watts Voltage Elite 52K 24 Amp 240VAC (30 Amp) 40 Amp 240VAC (50 Amp) 1.8 Amps 120VAC Air Mover 15,360/Both Circuits 240VAC Best Practices for Heating rooms 1. Always try to seal the room(s) from escaping heat. Especially HVAC vents, lights, bathroom exhaust fans, bottoms of doors, wall air-conditioners, etc Cover windows pane with blankets or equivalent to minimize loss of energy from cold windows. 2. Remove items that you would not leave in your car on a hot sunny summer day. Candles, lighters, many foods, candies, etc 3. Unplug all electrical items and do not place electrical items directly in front of the heater. Electrical items are rated for higher temperatures than you are heating, just avoid the direct heat coming out of the heater. 4. It is best to bag clothes, sheets, etc and run in the clothes dryer for 20 minutes on high. Never leave clothes laying on the floor or other surfaces or they will act as an insulator and it will be difficult to heat under them sufficiently. 5. Open all drawers and separate all items so hot air can get everywhere easily. 6. Stand or block box spring and mattress so hot air can contact all sides.

7. Place all fans blowing in the same direction along the walls in the area you are heating to circulate the hot air into every nook and cranny. If possible place at least one fan per wall. Turn on fans to ensure air movement is sufficient. Add more fans if it does not feel like a whirl wind (tornado type effect). 8. Place heater(s) so that the air is being immediately swept up by the fans and the hot air coming directly out of the heater is not directly hitting any furniture or building materials before being blown about by the fans. 9. Use no less than 1 heater for every 700sf in a normal room of ceiling height of 9 or less for maximum performance. You can never have too much equipment, only not enough. 10. Turn on heaters and make sure all heater light switches that have power are on. Heater switches will not turn on if you do not have power connected to the respective heater switch. This is ok if you are doing this on purpose because you don t have or don t need the full power of the heater. 11. Always check for fire sprinkler s installed in a building. Keep heat level at fire sprinkler head a minimum of 30F below the trigger temperature of the fire sprinkler. 12. Walls and ceilings made of block or concrete require more heat because they are more conductive of energy than drywall. This means 1 heater will heat less space when you have walls and/or ceilings with block or concrete. 50% more power is required as a general rule for these rooms. All buildings are not created equal and more conductive materials take more energy to heat.