Swing-Check Valves for Waterworks Service, 2-In. Through 48-In. (50-mm Through 1,200-mm) NPS

Similar documents
Ductile-Iron Pipe, Centrifugally Cast

Rubber-Gasket Joints for Ductile-Iron Pressure Pipe and Fittings

Steel Pipe Flanges for Waterworks Service, Sizes 4 In. Through 144 In. (100 mm Through 3,600 mm)

Bolted Sleeve-Type Couplings for Plain-End Pipe

Coating Steel Water- Storage Tanks

Cement Mortar Protective Lining and Coating for Steel Water Pipe 4 In. (100 mm) and Larger Shop Applied

IECEx Certificate of Conformity

Facility Fire-Suppression Water-Service Piping

2007 ASME Boiler & Pressure Vessel Code 2007 Edition July 1, 2007

IECEx Certificate of Conformity

ISO INTERNATIONAL STANDARD. Pipe flanges Part 1: Steel flanges for industrial and general service piping systems

H gh-p led Combust ble Storage. Application Guide 2009 Edition

This document is a preview generated by EVS

OHIO UNIVERSITY RADIATION SAFETY REVIEW

1 2 Stanley Security Solutions $ % 1,200 $8,700,000 $2, ,800 Indianapolis, Ind.

1. Welcome. Robert Smith, Chair. 2. Introductions and Update of Committee Roster. (attached)

Professional Publications and Presentations Published and Presented by Jack Poole, PE, Principal

IECEx Certificate of Conformity

INTERNATIONAL STANDARD

DIMENSIONAL STANDARD FOR 1/4" QUICK CONNECT COUPLER PLUGS AND SOCKETS FOR PORTABLE PRESSURE WASHERS

DIMENSIONAL STANDARD FOR M22 THREAD CONNECT COUPLER RECEPTACLES AND PLUG COLLARS FOR PORTABLE PRESSURE WASHERS

Bold items are particular to the City of Euless

2016 Annual Revision Cycle Consent Document NFPA 75

Alternate Evacuation Route B: Secondary direction of egress considered safe with the information available.

1.02 SUMMARY A. This Section includes piping and specialties for combined potable-water and fire-protection water service outside the building.

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

Insulated High Temperature Hook-Up Wire; Types ET (250 Volts), E (600 Volts), and EE (1000 Volts)

Obstructions and ESFR Sprinklers Phase 2 FINAL REPORT

ISO/TS TECHNICAL SPECIFICATION. Fire detection and alarm systems Part 9: Test fires for fire detectors

DOE FUNDAMENTALS HANDBOOK INSTRUMENTATION AND CONTROL Volume 1 of 2

Page 1 of 6 10/19/2016 9:49 AM. Public Input No. 4-NFPA [ Section No ] Statement of Problem and Substantiation for Public Input

Alternate Evacuation Route B: Secondary direction of egress considered safe with the information available.

Correlating Committee on Automatic Sprinklers

PUBLIC HEARING May 18, 2010 SUMMARY AND RECOMMENDATION

Subregion I. Proposed Sectional Map Amendment, August Preliminary Master Plan and

NFPA Technical Committee on Unmanned Aerial Systems

UL/FM Fire Protection Products

Matrix of changes for the National Standard Plumbing Code July 2013

CAN/ULC-S INTEGRATED SYSTEMS TESTING OF FIRE PROTECTION AND LIFE SAFETY SYSTEMS

INTERNATIONAL STANDARD

- Residential Fire Sprinkler -

CAN/ULC S Integrated Systems Testing of Fire Protection and Life Safety Systems and Fire Protection Commissioning

ISO INTERNATIONAL STANDARD

Australian/New Zealand Standard

PRODUCT BULLETIN. Rev. A Monitoring Station offering PN Rev. B as a direct replacement. OVERVIEW / DESCRIPTION

Fire Flow Water Consumption In Sprinklered and Unsprinklered Buildings:

REPLACEMENT PARTS LIST

NFPA Technical Committee on Hybrid (Water and Inert Gas) Fire Extinguishing Systems

CENTRAL STATE HOSPITAL PLAN SAFE USE HANDLING AND STORAGE OF FLAMMABLE AND COMBUSTIBLE LIQUIDS

AS/NZS :2015

Receive recommendations from representatives of the Future Land Use Plan Advisory Committee regarding their review of the Land Use Element of the

Distribution System Requirements for Fire Protection

25% 25% manufacturing. TOP 100 military friendly employer RANK: 77. Advanced Technology Services (ATS) Archer Daniels Midland Company

Sýnishorn ISO 7183 INTERNATIONAL STANDARD. Compressed-air dryers Specifications and testing. Sécheurs à air comprimé Spécifications et essais

Safety Program. Eastern Electrical Testing Corporation 2 Skyline Drive Clarks Summit, PA (570)

Update of ANSI Standards for Warnings and Future Directions

Revised March 2015 Fire Alarm Systems Verification. Schedule I(A) Services. *Manditory Site visit required*

Niagara Region Official Plan. Table of Contents

ISO INTERNATIONAL STANDARD. Rotary positive displacement pumps Technical requirements

ISO 3733 INTERNATIONAL STANDARD. Petroleum products and bituminous materials Determination of water Distillation method

Standards and Safety Update

Sanitizing Sink Heater

ISO/TS TECHNICAL SPECIFICATION

ISO INTERNATIONAL STANDARD

PURPOSE OF THE PROCEDURE

STORMWATER FACILITIES OPERATION AND MAINTENANCE PLAN. Example Commercial Project. February 21, 2018

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Petroleum, petrochemical and natural gas industries Rotary-type positivedisplacement. Part 1: Process compressors

ICC 902/ APSP 902/ SRCC Solar Pool and Spa Heating System Standard

REPORT NUMBER: SAT-001B ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE:

ANSI/ANS- An American National Standard

Loss Prevention Standard

True Auto-Purge System

CRP 336: REGIONAL AND ENVIRONMENTAL PLANNING FOUNDATIONS

Test Report. Appliance EMF Testing

American National Standard

UL/FM Fire Protection Products Setting the Standard

DRAFT NFPA 805 TRANSITION PILOT PLANT OBSERVATION GUIDANCE

INTERNATIONAL STANDARD

UL HAZARDOUS LOCATIONS SERVICES

ISO 2411 INTERNATIONAL STANDARD. Rubber- or plastics-coated fabrics Determination of coating adhesion

REAFFIRMED. specification for radiation shielding materials. September 27, 2016 ANSI/ANS ; R2016 ANSI/ANS

Introductions made by the Chair, committee members, NFPA Staff Liaison, Jacqueline Wilmot and Dan Gorham of the Fire Protection Research Foundation.

Harmonizing Electrical Installation Requirements

Emergency Action Plan

Flow Control for Fire Protection

Instructions for using the PerkinElmer DSC-8500

Licensed exclusively to SABS. Copying and network storage prohibited.

IECEx Certificate of Conformity

GUIDELINES FOR SIZING WATER HEATERS California Conference of Directors of Environmental Health September, 1995

MEMORANDUM. Technical Committee on Emergency Power Supplies. NFPA 111 First Draft Technical Committee FINAL Ballot Results (A2018)

Doc. Number: N Report of CEN/TC 267 Secretariat "Industrial piping and pipelines" for the 30 th Plenary Meeting 27 October 2016 (Paris)

Minnesota Rules, Chapter 4732 X-Ray Revision

SECTION (15530) - REFRIGERANT PIPING

Legislation, Standards and Technology. IEC TC 41 Explosion protection of electrical equipment

Chair Vice Chair Secretary R.J. Peppin. A.A. Scharine

IC Chapter Severe Weather Warning Sirens

Flow Control for Fire Protection

This document is a preview generated by EVS

Cumberland Comprehensive Plan Town Council adopted August 2003, State adopted June 2004 TABLE OF CONTENTS

Transcription:

SM ANSI/AWWA C508-17 (Revision of ANSI/AWWA C508-09) AWWA Standard Swing-Check Valves for Waterworks Service, 2-In. Through 48-In. (50-mm Through 1,200-mm) NPS Effective date: June 1, 2017. First edition approved by AWWA Board of Directors June 20, 1976. This edition approved Jan. 14, 2017. Approved by American National Standards Institute Jan. 3, 2017.

Committee Personnel The AWWA Standards Subcommittee for Swing-Check Valves, which reviewed and approved this standard, had the following personnel at the time of approval: J.V. Ballun, Chair S. Allen, Bray International, Houston, Texas. J.V. Ballun, Val-Matic Valve & Manufacturing Corporation, Elmhurst, Ill. D.E. Burczynski, Kennedy Valve, Elmira, N.Y. P. Gifford, Mueller Company, Chattanooga, Tenn. T.C. Harbour, Mueller Company, Elmhurst, Ill. R.L. Larkin, American Flow Control, Birmingham, Ala. L. Larson, DeZURIK, Sartell, Minn. G.E. Laverick, UL LLC, Northbrook, Ill. T. O Shea, DeZURIK-APCO, Schaumburg, Ill. N. Peyton, Henry Pratt Company, Aurora, Ill. J.H. Wilber, American AVK, Littleton, Colo. The AWWA Standards Committee on Gate Valves and Swing-Check Valves, which reviewed and approved this standard, had the following personnel at the time of approval: Joseph J. Gemin, Chair General Interest Members J.M. Assouline, CH2M, Englewood, Colo. M.D. Bennett, MWH Americas, Cleveland, Ohio D. Dieffenbach, Carollo Engineers Inc., Phoenix, Ariz. J.J. Gemin, AECOM, Kitchener, Ont., Canada J. Hebenstreit, UL LLC, Northbrook, Ill. M.C. Johnson, Utah Water Research Laboratory, Logan, Utah J.S. Olson, Advanced Engineering and Environmental Services, Watford City, N.D. S.M. Passarelli,* Standards Engineer Liaison, AWWA, Denver, Colo. T.R. Volz, URS Corporation, Denver, Colo. * Liaison, nonvoting Alternate iii

Producer Members J.V. Ballun, Val-Matic Valve & Manufacturing Corporation, Elmhurst, Ill. J. Bolender, J&S Valve Inc., Huffman, Texas D.E. Burczynski,* Kennedy Valve, Elmira, N.Y. S.S. Dalton,* Val-Matic Valve & Manufacturing Corporation, Elmhurst, Ill. P. Gifford,* Mueller Company, Chattanooga, Tenn. T.C. Harbour, Mueller Company, Decatur, Ill. D. Johnston,* East Jordan Iron Works Inc., East Jordan, Mich. R.L. Larkin,* American Flow Control, Birmingham, Ala. R. Looney, American AVK, Minden, Nev. T.J. Mettler, Waterous Company, South Saint Paul, Minn. J. Riese, Clow Valve Co., Oskaloosa, Iowa D.B. Scott, AMERICAN Flow Control, Birmingham, Ala. J.H. Wilber,* American AVK, Littleton, Colo. K.J. Wright, East Jordan Iron Works, East Jordan, Mich. User Members M. Garcia, Standards Council Liaison, Denver Water, Denver, Colo. B. Hasanabadi, Colorado Springs Utilities, Colorado Springs, Colo. S. Hattan, Tarrant Regional Water District, Ft. Worth, Texas K.S. Jeng-Bulloch, City of Houston/PW & Engineering, Houston, Texas M. MacConnell, Metro Vancouver, Vancouver, B.C., Canada A. Quiniones, US Bureau of Reclamation, Denver, Colo. D. M. Rausch, Aurora Water Department, Aurora, Colo. P. Ries, Denver Water, Denver, Colo. * Alternate Liaison, nonvoting iv

Contents All AWWA standards follow the general format indicated subsequently. Some variations from this format may be found in a particular standard. SEC. PAGE SEC. PAGE Foreword I Introduction... vii I.A Background... vii I.B History... vii I.C Acceptance... vii II Special Issues... viii III Use of This Standard... ix III.A Purchaser Options and Alternatives... ix III.B Modification to Standard... x IV Major Revisions... x 4.4 General Design... 10 4.5 Fabrication... 15 5 Verification 5.1 Inspection... 16 5.2 Testing... 16 5.3 Nonconformance... 17 6 Delivery 6.1 Marking... 17 6.2 Packaging and Shipping... 17 6.3 Affidavit of Compliance... 17 V Comments... x Appendix Standard 1 General 1.1 Scope... 1 1.2 Purpose... 3 1.3 Application... 3 2 References... 3 3 Definitions... 5 4 Requirements 4.1 Permeation... 6 4.2 Data to Be Supplied by Manufacturer... 7 4.3 Materials... 7 A Installation, Operation, and Maintenance of Swing-Check Valves for Waterworks Service... 19 A.1 General... 19 A.2 Unloading... 19 A.3 Storage... 19 A.4 Inspection Prior to Installation... 20 A.5 Installation... 20 A.6 Field Testing... 20 A.7 Owner s Records... 21 A.8 Operation... 21 A.9 Maintenance... 21 v

SEC. PAGE SEC. PAGE Figure 1 Various Types of Swing-Check Valves... 2 Tables 1 Copper Alloys... 8 2 End-To-End Dimensions for Flanged-End Valves... 11 3 Minimum Thickness for Ductile-Iron Connecting End Flanges... 12 4 Excess Flange Thickness... 13 vi