TC5F 熱流道溫度控制器 TC5F Hot-Runner Temperature 操作手冊 USER'S MANUAL. 長新科技股份有限公司 ARICO Technology Co., Ltd. 長新科技股份有限公司. Ver.:TC5F-1.0.2

Similar documents
The trademark of ARICO Technology Co. Ltd., consists of a white human icon, three squares and alphabets :

WT7502 PC POWER SUPPLY SUPERVISOR. Data Sheet REV Feb. 26, 2008

RAS-DX18HDK/RAC-DX18HDK

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

POT-100C / POT-102C POT-200C /POT-202C

SYL-1512A PID TEMPEARATURE CONTROLLER INSTRUCTION MANUAL Version 2.1

PE Series Jaw Crusher P E

ARTIFICIAL INTELLIGENCE TEMPERATURE CONTROLLER

Temperature Control Systems

Series Temperature Controller Instruction Sheet

PMAC202 Branch Circuit Power Meter User Manual V1.0

MC-5 Series Micro Processor Temperature Controller

+ A B V B NO NC V COM PV PV

PV Ribbon Hi-speed Tin-plating Machine List

Safety Information. Functional Description. Operation. DANGER Do not touch or contact the input/output terminals because it may cause electric shock.

Table of Contents SECTION PAGE

Communications* None RS-232C RS-422 RS-485 BCD Transmission output** (4 to 20 ma)

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER FCS-23A

SOLDER POT POT-100C / 103C POT-200C / 203C

Serie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0)

Temperature Controllers

WARNING CAUTION. Do not expose yourself to wind generated by the productfor a long time.

TEMPERATURE CONTROL MODULE MODEL R3-TC2

Series Digital Controller Instruction Sheet

A New Generation of Active Intrusion Detection System for Physical Protection

Mark 25 Ultrapure Water Conductivity Analyzer

DT968C C.T. BATH CONTROLLER

VT4810 SINGLE / DUAL ZONE CONTROLLER INSTALLATION MANUAL

FIBARO FLOOD SENSOR OPERATING MANUAL FGBHFS-101 CONTENTS. #6: Functionalities 8 #7: Configurable parameters 9 #8: Specifications 10 #9: Regulations 11

Halton SAFE / 7.14 user guide and installation instructions

F4 Process Controller Installation and Operation Guide

MICRO CONTROLLER S Z SERIES

Micro-controller X C C1 C2 AL1 AL2 AL3. Model: PXR4/5/9. Operation Manual SEL PXR. ECNO:406e

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Table of Contents DIGITAL DRYING OVEN. Features. Setup. Cautions. Description of the parts. Temperature Controls. Maintenance and Storage

LA type soldering iron controller

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

Intelligent Lead Free Soldering Station OPERATION and MAINTENANCE MANUAL

TEMPERATURE CONTROLLER

WARNING/CAUTION DESCRIPTION OF COMPONENTS FUNCTION EXPLANATION OPERATION INSTRUCTIONS CONTINUOUS DRAINAGE CAUTIONS MAINTENANCE/EMERGENCY

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS...

General Specifications

HOBO MX Temp/RH Data Logger (MX1101) Manual

SCAD-U Series Compressed Air Dryer

User s Guide. CN616 Series 1 4 DIN Economical 6-Zone PID Temperature Controllers. Shop online at omega.com SM

Microchip 产品用户参考手册 单片机集成方案全方位解决服务商 优质智能电子产品 芯 方案解决商 深圳市英锐恩科技有限公司 深圳市英锐恩科技有限公司 ENROO-TECH(SHENZHEN)CO.,LTD 中国 深圳市福田区福华路嘉汇新城汇商中心 27 楼 2701

Operation Manual. (Version 1.5.1)

Chapter 8 Troubleshooting

HPS-C-MULTI 6. Hotrunner Controllers. Operating manual. Valid for item numbers:

CG Series Digital Temperature Controller OPERATIONS MANUAL

Chapter 8 Troubleshooting

PRODUCT STRUCTURE. Indoor Unit. Outdoor Unit. Fig.1. Air in. Air out. Display. Air in. Air out P.1. Display. Surface panel. Louver.

TAIE. Features. FY600 (96mm X 48mm) Application:Control temperature,humidity, FY Series Digital PID Controller

Operating Functions Temperature Parameters

TECHNICAL PRODUCT DATASHEET

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

RS485 MODBUS Module 8AI

HOT RUNNER TEMPERATURE CONTROLLER

GAO THERMAL CONTROL TECHNOLOGY CO.,LTD

EC Series Wall Unit Humidifier

User s Guide CN616A. Universal 6 Channel ¼ DIN Process Controller. Shop online at omega.com

CLEANROOM MONITOR CR3A Network - Installation Instructions

ELITE-600 DENTAL PORCELAN FURNACE

CONTENTS Operation and maintenance. Installation service

TC515 and TC600 Installation Manual. a Winters company

TAIE. Features. FY900 (96mm X 96mm) Application:Control temperature,humidity, FY Series Digital PID Controller

Far-infrared method Pre-Heater

REFRIGERATED BATH CIRCULATOR. Instruction Manual. Covers model : LRBC-13C / LRBC-22C. Please read this manual carefully before using the instrument

INSTRUCTION MANUAL. Laboratory Equipment Pty Ltd Ph: Fax:

SERVICE MANUAL 42QHF009DS* 42QHF012DS* 42QHF018DS* 42QHF022DS* 38QUS009DS* 38QUS012DS* 38QUS018DS* 38QUS022DS* Indoor unit.

VERTEX F4 Instruction Manual

Dryer Controller M720

UDC 700 Universal Digital Controllers and Indicator Specifications

SITC-15 Temperature Controller GITC-15 Temperature Controller Mainframe Operation Manual

Simple to Set Timer (SST) Frequently Asked Questions

Mission 份有限公司 wwwom 先锋科技股份有限公司 www Working with our customers we identify, design and deliver low light detection solutions which solve customer probl

MODEL P531, P532 AND P532UI FLAME MONITOR OPERATING MANUAL

INSTALLATION INSTRUCTIONS FOR SERIES 9 INTERMITTENT PILOT IGNITION CONTROL

OPERATING MANUAL BFS-MP SERIES FREEZING STAGES

CELLTROL II BIOREACTOR CONTROL SYSTEM OPERATIONS MANUAL

AFMS Audible Flow Monitoring System TECHNICAL SPECIFICATION

Operation Manual (Version 1.5.1)

TEMPERATURE CONTROLLER

TEMPERATURE CONTROLLER R/S (ADVANCED MODEL)

公司願景 業務項目 我們的願景是能為您帶來更加 健康 舒適 便利 的生活環境 水的控制專家 晴立實業 創立於 1993 年 十幾年來致力於排水器及週邊產品之研究與開發 多年來的創新及研發成果獲得多項產品專利, 深受各界的肯定, 於業界亦趨領導地位 為了服務客戶長久以來的支持,

HD220 Dual Output Programmable Humidity Controller

DIGITAL TEMPERATURE RELAY TR-100

Temperature Controller

Bench-Top Vacuum Oven with 28 segments programmable controller

即熱式電熱水器即热式电热水器. Instantaneous Water Heater 使用說明書

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

THE EVOLUTION OF CONTROL APP & CLOUD PORTAL

R-S32EPH R-S32EPHL

CONTENTS Introduction and Characteristics. 1 Fire Alarm System Assembly Diagram.. 2 Fire Alarm Signal Flow Chart.. 2 Panel Descriptions 3 Standard

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

eed quality electronic design USER s MANUAL

Code 2. A AC/DC 100~240V N None

Safety & Installation Instructions

HOBO MX CO 2 Logger (MX1102A) Manual

Transcription:

長新科技股份有限公司 ARICO Technology Co., Ltd. Registered to ISO 9001 TC5F 熱流道溫度控制器 TC5F Hot-Runner Temperature 操作手冊 USER'S MANUAL Ver.:TC5F-1.0.2 長新科技股份有限公司 ARICO Technology Co., Ltd. 保有權利於任何時間未經通知而修改或變更本手冊內容及型式, 未經本公司同意, 不得作任何形式的使用 reserves the right to make any kind of design or functional modification at any moment without prior notice.

To avoid wrong operation, which may result in human injured or machine damage, please read this instruction carefully before use the instrument. CONTENT Chapter 1 TC5F TEMPERATURE CONTROL MODULE 1-1 Features 2 1-2 Specification 2 1-3 Faceplate 3 1-4 Operation description 5 Chapter 2 CABINET&ACCESSORIES 2-1 Dimension 11 2-2 Specification 12 2-3 Connection description 12 2-4 Type of power wiring 13 2-5 Connector wiring 15 Chapter 3 ORDER CODERING 3-1 Cabinet 18 3-2 Cable 18 3-3 Housing 19 3-4 Hood 19 3-5 Blank Plate 19 3-6 Connector 19 3-7 Trouble shooting 20 ARICO Technology Co., Ltd. -1-

Chapter 1 TC5F TEMPERATURE CONTROL MODULE 1-1 Feature Dual SV temperature control. Tri lines LED display. Auto /Manual function. PID auto temperature control. Selectable two thermocouple types.(j or K) Selectable two temperature scales.( or ) Selectable six alarm modes. Selectable two trigger output modes.(zero cross or phase angle) Fuse break indicator. Electric current, output percentage, frequency for power display function. Heater breaks, shorts out, wears out to detect and examine the function. Thermocouple break and inverse detect. Thermocouple range K TYPE 0~700 (0~1200 )/J TYPE:0~500 (0~900 ). RS485 communication: ASCII and RTU molding. 1-2 Specification Power input:220vac±20% Power frequency:50/60hz Power consumption:7w Input impedance:3mω Output wattage:3600w(max) 15A/240Vac(Every module) Storage temperature:-20~70 Working temperature:0~50 Work Humidity:10~80%RH (Non-condensing) Control accuracy:±0.25% Measurement accuracy:±0.25% -2-

1-3 Faceplate 1-3-1 Faceplate description (9) (10) (11) (12) (13) (14) (15) (16) (1) (2) (3) (4) (5) (6) (7) (8) (1) PV: 1.Normal mode:present value 2.Parameter mode:parameter name (2) SV: 1.Normal mode:setting value 2.Parameter mode:parameter name 3.Manual output or parameter: Manual output% (3) Aux. display : output percentage, electric current, frequency display. (4) PAGE key : Parameter level and parameter select key. (5) Set key:set enable and digital shift key. (6) Increment key:setting number increase. (7) Decrement key:setting number decrease. (8) Aux. display PAGE key:parameter select key (9) PID tuning indicator:in PID tuning, progress indicator flashes. (10) Manual output:light up when Manual output (11) Alarm indicator:light up when alarm happen. (12) output indicator : Light up when instrument output (13) Cool indicator: While cooling the indicator lamp is on (14) Fuse 1 indicator:light up when fuse 1 break (15) Fuse 2 indicator:light up when fuse 2 break (16) Power switch ARICO Technology Co., Ltd. -3-

1-3-2 Faceplate appearance and dimension Deviation:±5mm -4-

1-4 Operating description 1-4-1 Parameter flow chart ARICO Technology Co., Ltd. -5-

-6-

1-4-2 Soft start (Heater dehumidify) function To avoid the humidity burning the heater out, the soft start function could output a lower current to dehumidify the heater when the power turned on. Soft start condition: The soft start percentage (SSP) and time (SST). After power turned on, if SV > PV ; PV < 120, manual and PID tuning function are disabled, the soft start will be executed. Set SST to zero to stop soft start function. Soft start action state: Before SST time countdown completes, soft start outputs in 1%/sec accumulative mode until it gets SSP setting value. The accumulative mode will stop and wait SST time to complete countdown. Soft start stop on halfway: Press F for 2 sec to close soft start. 1-4-3 Control mode Auto mode: The instrument performs PID auto temperature control Manual mode: Manually adjust output percentage (UNIT displays "P ) via NOP to hold the temperature. Manual/Auto mode switch:press display interchange for 2 sec. 1-4-4 Communication Communication mode:modbus ASCII / RTU Baud rate:9600/19200/(value of production38400) ID:1-250(value of production: 1) According to the procedure of HMI ARICO Technology Co., Ltd. -7-

1-4-5 Process control: Start conditions:stg is ON Action mode:before TGT time completes countdown. SV1 is the main display. 1-4-6 Over current protect Control: Regular :Actual current < 15 A Malfunction: When actual current is >15A, the output will stop and O1ST display on the first set of monitor. After 1 minute, output resumes and detects the current. If it s 15A and it occurs more than 3 times, the output stops and the alarm starts with O1ST display. (PS: If the heater shorts out, the 20A fuse breaks) TRIAC Malfunction:When start action delays within 30 sec, the module will force output ratio to 0%. Regular:Actual current= 0 A -8-

Malfunction:When actual current is> 0 A, control will stop and alarm start, O1ST message will appear on first set of LED until the model starts power again. 1-4-7 Cooling control Start term:cool= ON Action mode:the cycle time is CYT1. The output is P control way. 1-4-8 Alarm code ERRC 1 :Thermocouple break 2 :Thermocouple inverse 4 :Heat output short 8 :Heat output break 1-4-9 Error message (1) :Thermocouple break (2) :Heater break (3) :PV lower than SV (4) :Heat output short ARICO Technology Co., Ltd. -9-

1-4-9 PID auto tuning function To get the optimal PID value in some system, it is possible to execute "PID auto tuning" function at first use or heater system change After finishing auto tuning, the optimal PID will be saved into the instrument and memory and will use the latest PID value for optimal temperature control. PID auto tuning function: (1)PV must be lower than 120 or 180 (2)SV must be higher than PV for 80 or 100 (3)Set parameter TUN into YES PS:During PID auto tuning execution, the decimal point of PV will flash. After the instrument gets the optimal PID, the decimal point turns off and the instrument returns to auto temperature control. -10-

Chapter 2 CABINET 2-1 Dimension Unit:mm Cabinet A B C D 1 Zone 188 96 248 30 2 Zones 223 4 Zones 323 6 Zones 215 424 299 45 8 Zones 524 12 Zones 726 ARICO Technology Co., Ltd. -11-

2-2 Specification Type T5A01 T5A02 T5A04 T5A06 T5A08 T5A12 Zone Item 1 2 4 6 8 12 Power Switch (A) -- 32 50 50 63 63 Output connector Power Cable Weight (kg) (non-module) 4pin+E (ground) 16pins x1 2.0mm 2 5.5mm 2 x3c x5c x3m x3m 16pins x1 24pins x1 16pins x2 24pins x2 5.5mm 2 5.5mm 2 8.0mm 2 8.0mm 2 x5c x5c x5c x5c x3m x3m x3m x3m 1.75 7.25 9 11.25 12.5 16 2-3 Connection Description Connector type a: single hook b: single button c: dual hook d: dual button connector A B C D Housing Hood Hood Housing Name T5E T5F T5F T5E Type Socket Plug Socket Plug combination 1* a b b A 2 c d d C 3 d c c d *Standard type **T5A01only for type1-12-

2-4 Type of power wiring ARICO Technology Co., Ltd. -13-

The following power wiring only for T5A01. Caution 1. Before operating, check connection ("y" or " ") and its voltage. 2. All instruments must be used in accordance with the specification to prevent fire or damage to instrument and equipment. 3. Make sure the ac power input is switched off before maintenance. Note: power type A and B differ with regard to " " connections. The FGND must be connected with earth ground. 2-4-4 Communication port Socket Plug -14-

2-5 Connector wiring Single cabinet connector wiring ZONE CONN CONNECTOR ASSIGNMENT 1 A4-1 4*1 Multi-cabinet connector wiring are divided into A, B, C and D type as below: A type wiring ZONE CONN CONNECTOR ASSIGNMENT 2 16*1 A16-2 4 16*1 A16-4 6 24*1 A24-6 8 16*2 A16-8 12 24*2 A24-12 ARICO Technology Co., Ltd. -15-

B type wiring ZONE CONN CONNECTOR ASSIGNMENT 2 16*1 B16-2 4 16*1 B16-4 6 24*1 B24-6 8 16*2 B16-8 12 24*2 B24-12 -16-

C type wiring ZONE CONN CONNECTOR ASSIGNMENT 8 16*2 C16-8 12 24*2 C24-12 D type wiring ZONE CONN CONNECTOR ASSIGNMENT 2 16*1 D16-2 4 16*1 D16-4 6 24*1 D24-6 8 16*2 D16-8 12 24*2 D24-12 ARICO Technology Co., Ltd. -17-

Chapter 3 ORDER CODE 3-1 CabinetT5A T5A a:zone d:power Cable Length 01:1 zone 03:3m (standard) 02:2 zones e:o/p Connector Wiring 04:4 zones A:A type 06:6 zones B:B type 08:8 zones C:C type 12:12 zones f:cable Wiring 00: without connection cable b:housing and Hood 03:3m (standard) SHB:Housing is single hook, hood is single button* DHB:Housing is dual hook, hood is dual button DBH:Housing is dual button, hood is dual hook c:power Wiring A0:A type 3-phase 4-wire 200~242VAC B0:B type 3-phase 5-wire 380~415VAC A1:A type 3-phase 4-wire 200~242VAC* B1:B type 3-phase 5-wire 380~415VAC* *:for 1 zone T5A01 3-2 Cable:T5C Order code:t5c a:wiring b:pin c:length(m) Standard Length 3M -18-

3-3 Housing:T5E Single Dual hook Single button Dual button Order code:t5e a:pin--4 16 24 b:type 1. Single hook 2. Dual hook 3. Single button 4. Dual button 3-4 Hood:T5F Single hook Dual hook Single button Dual button Order code:t5f a:pin--4 16 24 b:type 1. Single hook 2. Dual hook 3. Single button 4. Dual button 3-5 Blank plate 3-6 Connector Order code:t5g Order code:t5d a:pin--4 16 24 b:type 1. Plug 2. Socket ARICO Technology Co., Ltd. -19-

3-7 Trouble shooting Malfunction status 1. No action after power on. 2. F1 or F2 fuse break indicator bright. 3. Display " ". 4. Display " ". 5. No display PV normally or PV unstable. Check item Module is installed properly? Power wiring is correct? Main power switch is malfunction? Module is malfunction? Change the fuse accord with the brightly indicator. Module is installed properly? Thermocouple is break? Extension cable is loose or breaks? Module is malfunction? Thermocouple is reverse? Module is malfunction? Refer to item 3. Power leakage? The ground is properly? 6. In the normal operation, the temperature cannot rise up. Module is installed properly? Extension cable is loose or breaks? Heater is malfunction? Module(TRIAC)is malfunction? 7. Temperature control is unstable. Refer 1-4-10, execute PID self tuning. -20-

長新科技股份有限公司 ARICO Technology Co., Ltd. 總公司 (HEADQUARTERS) 23145 新北市新店區寶橋路 235 巷 1 弄 1 號 8 樓 8F., No.1, Alley. 1, Lane 235, Baociao Rd., Sindian District, New Taipei City, 23145, Taiwan TEL:+886-2-29101266 FAX:+886-2-29159434 www.arico.tw / www.arico.com.tw ARICO Technology Co., Ltd. -31-