Thermo Scientific Ramsey TM Series Sensing Speed Conditions on Rotating Shafts and Machinery

Similar documents
Ramsey Series Motion Monitoring Systems Accurate Sensing of Speed Conditions on Rotating Shafts and Machinery

Ramsey Motion Monitoring Systems

SAPCON SMART-SSI. Continuous Speed Indicator. Users Manual. . Introduction. . General Description. . Principle of Operation. .

POSITIONERS CONTROLS ELECTRO-PNEUMATIC INTELLIGENCE FOR DOUBLE & SINGLE ACTING PNEUMATIC ACTUATORS SERIES 6A. The High Performance Company CELEBRATING

Operations Manual. Motion Detector Module Model ZS10

Process Protection. MFA 4P Motion Failure Alarm

T500 Elite - Hotbus Plant Wide Monitoring System for Bucket Elevators & Conveyors

Low-Cost, Non-Invasive, Microwave-Based Bulk Solids Flow Detector

The LC-100 s valved manifold controls the flow of air and allows the LC-100 to accurately monitor liquid levels with a minimal air usage.

Software Version 2.01 LEVEL MONITOR MODEL 220

Belt Conveyor Safety Monitoring Devices

DSD-3 DIFFERENTIAL SPEED DETECTOR

Pioneer-R16 Gas Monitor Operator s Manual

Watchdog Elite Watchdog Elite BRAIME Product Information Bucket Elevator & Conveyor Hazard Monitor

Ultrasonic Switches. Features & Benefits

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

Ultrasonic Point Level Switches

T6984F,G Electronic Floating Control Thermostats

OVEN INDUSTRIES, INC.

Solid State Relays SOLITRON MIDI Current Sensing Type RJCS, RJCSR

Data Sheet 220 LEVEL MONITOR. Supplied by. .com. Call us on +44 (0)

TABLE OF CONTENTS Flow Detect 1000 Specifications 3 Description 4 Principle of Operation 4 Detection Through Walls 4 Sensing Beam Shape 4 Installation

Nov 08 PRODUCT SPECIFICATION SHEET

Sierra Series 900 Single & Dual Channel System. Instruction Manual

THERMAL MANAGEMENT SOLUTIONS

OPERATION MANUAL Part No. MIL8001V4C

ECW-GF, ECW-GF-DP DIGITAL ELECTRONIC CONTROLLERS AND REMOTE DISPLAY PANEL PRODUCT OVERVIEW

MAINTENANCE & TROUBLESHOOTING GUIDE LEAK ALARM CHANNEL DRY OIL WATER AUX ALARM HIGH LOW CRITICAL WATER TANK LEVEL ALARM MODEL LDE-740 ADVANCE PAPER

Frequently asked questions: Intelligent Transmitter Series

THERMAL MANAGEMENT SOLUTIONS

High Pressure Conductivity Monitor

Installation Instructions for W2H Series Signals

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH

Modus Model DA General Eastern Low Differential Pressure Alarm Controller

T7984 A,B,C Electronic Modulating Control Thermostats

Centro-Matic Automated Lubrication Systems System Controls

OPERATION MANUAL Part No s. P8003V10C, P8004V10C

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

Is your process protected?

NEW! Thermo Scientific Revco PLUS Ultra-Low Temperature Upright Freezers. Maximizing Critical Sample Protection and Storage

4 & 8-POINT ANNUNCIATORS Instruction Manual

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

Quick Start Manual July pointek CLS100

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

Retro-reflective Sensing range: 0mm to 2000mm

Installation and Operating Instructions

Introduction to Flow Switch

L8005A,B; LS8005A,C,D Electronic Pool and Spa Controllers

WH EN IGH T T C LO SED

T6984 A,D,E Electronic Floating Control Thermostats

PRODUCT INFORMATION HISIC450 OVERHEIGHT DETECTORS RELIABLE OVERHEIGHT DETECTION OF VEHICLES. Traffic sensors

Speed and Frequency Seite 1 von 7

ProxView Programming Software. iprox Inductive Sensors iprox Programming Tools. iprox Sensors. iprox. The world s most versatile proximity sensor.

Sensall Sapphire. Thermo MeasureTech ULTRASONIC POINT LEVEL SYSTEM

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

ELECTRONIC HUMIDISTAT: H200

Model Q45P/R. ph/orp Monitor...

DTM Distributed Transmitter-Monitor

INSTRUCTION MANUAL MODEL LDE 740. (Revised July 8, 2017)

Sapphire ULTRASONIC POINT LEVEL SYSTEM

Date SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1

PURGE/PRESSURIZATION SYSTEM

Metal Tube Variable Area Flowmeter with Optional Electronics based on Smart Meter Manager Technology

Page. 1-2 Sepra-Lite Integral Optic Level Switches. 3-5 Electro Optic Level Systems: Probe and Controller

Sintrol Snifter A1+ Manual. Version 1.2.2

NEW! Thermo Scientific Revco PLUS Ultra-Low Temperature Upright Freezers. Maximizing Critical Sample Protection and Storage

DEIF A/S. Description of options. Option M17, Configurable inputs and RPM supervision Engine Controller EC-1/EC-1M. Description of option

Two-Channel Gas Controller

Troubleshooting Thermo Scientific LevelPRO Gauges

873A Series Electrochemical Analyzers ph, Contacting Conductivity, Electrodeless Conductivity, and Resistivity

Model Q45P/R. ph/orp Monitor...

Instructions. Easy-wire terminal strip Microprocessor-operated. Easy remote sense. Self-checking program. Diagnostic/status LED s

QVE1901U Flow Switch. Technical Instructions Document No September 20, Description. Features. Application.

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev.

MODEL 5100 VOTING LOGIC MODULE

ABB MEASUREMENT & ANALY TICS DATA SHEET. RS85 Vibrating fork level switch

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

MHC Series Sensors

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

VIBRATION TRANSMITTER MODEL 140T INSTALLATION The mounting orientation can be in any position. This position should be in an area for the best vibrati

7800 SERIES RM7888A Relay Module

Oxygen (O2) Single-Point Gas Detection System

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

5.0. Photoelectric Sensors. Technical Reference. Introduction

Brooks MT3600 Series Metal Tube Variable Area Flowmeters

SAFETY INFORMATION AND WARNINGS

Power Transfer Devices. Access Control Accessories. How To Order. How to Order

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

T7079A,B Solid State Remote Temperature Controllers

OG-Cube Photoelectric Sensors Optical sensing technology

DIGITAL METERS Large Display Temperature Meters Instruction Manual

Safe T Net 210. Instruction Manual Part Number Mar2010

MODEL 4100-LEV. Level Monitor. User Manual

Model 7700 Pump Director Valve and Pump Motor Interface Controller

Reyrolle Protection Devices. 7PG26 DAD High Impedance Current Relay. Answers for energy

Y-Plant Alert. Alarm Annunciator and Sequence of Event Recording System. BU 04M01A02-01E-A

Worcester Controls PS/PM Series UltraSwitch. Switchbox

Transcription:

Thermo Scientific Ramsey TM Series 60-200 Sensing Speed Conditions on Rotating Shafts and Machinery The Thermo Scientific Ramsey Series 60-200 monitors under-speed, overspeed and zero-speed conditions on various types of machinery by sensing speed variations of rotating parts. They detect any deviance from your acceptable operating parameters, allowing you to troubleshoot system upsets or failures. This leads to reduced downtime and increased productivity, ultimately adding to your bottom line. Product Specifications The Thermo Scientific Ramsey Series 60-200 motion monitoring systems offer a choice of versatile and reliable packages for monitoring under-speed, over-speed and zero-speed conditions on various types of machinery and systems by sensing the speed variations of rotating parts. You can choose from mechanically coupled (shaftdriven) or non-contacting proximity type sensors to satisfy your particular application requirements and design preferences. These unique control packages are housed in separate NEMA 4X enclosures and can be mounted near the sensing components or, for convenience and accessibility, up to 305 m (1,000 ft) from the sensor. Optional signal amplification accessories can increase that distance.

Thermo Scientific Ramsey Series 60-200 Motion Monitor Control Thermo Scientific Ramsey Model 60-200 Motion Monitor Control The Ramsey Model 60-200 programmable motion monitor control is a flexible microprocessor-based controller that can be used with any Thermo Scientific sensor and, in some cases, with compatible pulse output sensors from other sources. All alarm functions, delays and operating parameters are entered via a simple three-button keyboard. There are no potentiometers to adjust. A four-digit, seven-segment display shows the current speed as a percentage relative to a user-programmed reference speed. It also displays various parameters and setup values when the control is in its setup mode. Finally, the display shows an error code if any problems occur. This helps the operator to troubleshoot system failures or other difficulties. Detailed programming instructions are contained in the system manual and a quick reference programming guide is displayed on a label inside of the control s enclosure cover. Depending on the model used, one or two DPDT outputs are available to transfer information about the monitored conditions from the monitor to remote alarm displays or control functions. Also available is a 0 to 2 VDC output or an optional 0-20 ma/4-20 ma signal proportional to the rotational speed of the monitored shaft. Alarms can be set at 1% increments over a range of 0% to 160% of the reference speed. With the dual channel 60-200-2 models, one output can be set for over-speed and one can be set for under-speed, or both can be set to monitor over-speed or under-speed. Other programmable setup features include: start-up delay, alarm delay, restart mode, start-up delay initiation and alarm clearing. 158.8 mm (6.25 in) 114.3 mm (4.5 in) 136.5 mm (5.375 in) 111.1 mm (4.375 in) 201.3 mm (7.925 in) Ramsey Model 60-200 Motion Monitor Control

Thermo Scientific Ramsey Model 60-24 Motion Sensor Thermo Scientific Ramsey Model 60-24 Motion Sensor The Ramsey Model 60-24 motion sensor is a direct coupled, shaft-driven sensor used for measuring shaft rotation. It is available as a single or dual channel monitor and can be utilized as a high speed (up to 2,000 RPM) or low speed (up to 50 RPM) sensor. The very low speed version is capable of very sensitive operation at very low shaft speeds (less than 0.025 RPM). All systems include a conduit type connector and 1.5 m (5 ft) lead wire. 127 mm (5 in) 114.3 mm (4.5 in) 82.6 mm (3.25 in) These motion sensors are suitable for Class II hazardous areas. If used in a Class I hazardous area, an intrinsic safety barrier must be incorporated into the signal leads. The Ramsey 60-200 control must always be located in a non-hazardous area. Sensor options include two types of mounting hardware and intrinsic safety barriers. 50.8 mm (2 in) 79.4 mm (3.125 in) 63.5 mm (2.5 in) 12.7 mm (0.5 in) NPT 9.5 mm (0.375 in) 44.5 mm (1.75 in) Ramsey Model 60-24 Direct Coupled Sensor 44.5 mm (1.75 in) 73 mm (2.875 in) 76.2 mm (3 in) 35 mm (1.375 in) Ramsey Model 60-24 Mounting Bracket

Thermo Scientific Ramsey Model 60-22 Motion Sensor Thermo Scientific Ramsey Model 60-22 Motion Sensor The Ramsey Model 60-22 motion sensor is a non-contacting proximity type sensor used for measuring shaft rotation. It is available as a single or dual channel monitor and can be utilized as a high speed (up to 5,000 RPM) or low speed (up to 50 RPM) sensor. The sensor includes a LED that indicates pulse output. This feature simplifies system installation for correct gap setting and troubleshooting. All sensors include 6 m (20 ft) of lead wire and a mounting bracket. The low speed version includes a 30-segment target disc and mounting kit. These motion sensors may be mounted in Class I or II, Division 2 hazardous areas if the wiring is run in approved conduit. For use in Class I or II, Division 1 areas, an intrinsic safety barrier must be incorporated into the signal leads. The Ramsey 60-200 control must always be located in a non-hazardous area. The motion sensor options include: a stainless sensor, intrinsic safety barriers, conduit connectors, long range sensors and several target options with appropriate hardware. 95.3 mm (3.75 in) 88.9 mm (3.5 in) 57.2 mm (2.25 in) 38.1 mm (1.5 in) Ramsey Model 60-22 12 mm and 30 mm Sensor Mounting Bracket M12x1 LED 12 mm (0.472 in) Dia. 30 mm (1.181 in) 51 mm (2.008 in) 10 mm (0.394 in) 15 mm (0.591 in) LED M30x1.5 30 mm (1.181 in) M12x1 12 mm (0.472 in) Dia. 40 mm (1.575 in) 63 mm (2.48 in) 10 mm (0.394 in) Ramsey Model 60-22 12 mm and 30 mm Sensor

Specifications Thermo Scientific Ramsey Model 60-200 Motion Monitor Control Programmable Features Start-Up Delay 0-99 seconds Alarm Setpoint(s) 0-160% Alarm Delay 0-99 seconds Reset Mode Power on; Remote relay input Begin Start-Up Delay Power up; First pulse Alarm Clear Manual (latched); Automatic Thermo Scientific Ramsey Model 60-24 Motion Sensor Programmable Features Reference Speed Display Speed Alarm Adjustment Start-Up Delay Alarm Delay Reset Mode Start Conditions Alarm Clear Learned by operator pressing and holding Select key for five seconds At touch of key, current speed is displayed as a percentage of reference 0% to 160% of reference speed, in 1% increments, subject to minimum alarm setpoints shown with various models. Dual channel model has two separately adjustable alarm points. Channels may be set for underspeed and/or overspeed. Power on/remote reset or PLC control Power on or detection of pulses Automatic or manual (latched) reset. Various error messages are generated via the LED display to alert user of programming errors or system faults. Programming instructions are stored in permanent memory and will be retrieved when power is applied. General Specifications Voltage 115 VAC 60 Hz or 230 VAC 50 Hz ±10% 1 Operating Temperature 60-200-1: -40 C to +50 C (-40 F to +122 F) 60-200-2: -40 C to +85 C (-40 F to +185 F) Enclosure Noryl GFN3 (NEMA 4X), See drawing for dimensions. Outputs Model 60-200-1: Single channel, one adjustable output. (1) DPDT 230 VAC/5A Non-Inductive 2A Inductive Relay (NC/NO Selectable). Model 60-200-2: Dual Channel, two independently adjustable outputs. (2) DPDT 230 VAC/5A Non-Inductive 2A Inductive Relay (NC/NO Selectable). Both models have 0 to 2 VDC output or an optional 4-20 ma signal available, proportional to rotational speed of monitored device. 1 VDC equals reference speed (100%). Sensor Input NPN (up to 3 KHZ), PNP 2, or dry contact 2. Operating Ranges 60-24H System: up to 2000 RPM; Minimum alarm setpoint = 1.25 RPM 60-24L System: up to 50 RPM; Minimum alarm setpoint = 0.1 RPM 60-24VL System: up to 10 RPM; Minimum alarm setpoint = 0.025 RPM Sensor Specifications Supply Voltage 12 VDC from 60-200 monitor Output Open collector NPN 100 ma current sinking Electrical Connection Furnished with 1 2-in NPT conduit fitting and 5-ft 22 AWG leads with butt splices Operating Temperature -40 C to +85 C (-40 F to +185 F) Sensor Housing Polished aluminum Mounting Hardware Furnished as option only. Can supply flexible strap with rigid coupling, recommended for speeds up to 200 RPM, or rigid mounting bracket with flexible coupling, recommended for shaft speeds in excess of 200 RPM. See Options. 1 The dual channel 60-200-2 model (only) has a power transformer that is adaptable to other voltages and frequency power supplies that are found outside of the USA. 2 Applies to 60-200-2 only

Specifications Thermo Scientific Ramsey Model 60-22 Motion Sensor Programmable Features Reference Speed Display Speed Alarm Adjustment Start-Up Delay Alarm Delay Reset Mode Start Conditions Alarm Clear Learned by operator pressing and holding Select key for five seconds At touch of key, current speed is displayed as a percentage of reference 0% to 160% of reference speed, in 1% increments, subject to minimum alarm setpoints shown with various models. Dual channel model has two separately adjustable alarm points. Channels may be set for underspeed and/or overspeed. Power on/remote reset or PLC control Power on or detection of pulses Automatic or manual (latched) reset. Various error messages are generated via the LED display to alert user of programming errors or system faults. Programming instructions are stored in permanent memory and will be retrieved when power is applied. General Specifications Voltage 115 VAC 60 Hz or 230 VAC 50 Hz ±10% 1 Operating Temperature 60-200-1: -40 C to +50 C (-40 F to +122 F) 60-200-2: -40 C to +85 C (-40 F to +185 F) Enclosure Noryl GFN3 (NEMA 4X), See drawing for dimensions. Outputs Model 60-200-1: Single channel, one adjustable output. (1) DPDT 220 VAC/5A Non-Inductive 2A Inductive Relay (NC/NO Selectable). Model 60-200-2: Dual Channel, two independently adjustable outputs. (2) DPDT 220 VAC/5A Non-Inductive 2A Inductive Relay (NC/NO Selectable). Both models have 0 to 2 VDC output or an optional 0-20 ma, 4-20 ma signal available, proportional to rotational speed of monitored device. 1 VDC equals reference speed (100%). Sensor Input NPN (up to 3 KHZ), PNP 2, or dry contact 2. Operating Ranges 60-22H System: up to 5000 RPM; Minimum alarm setpoint = 12 RPM 60-22L System: up to 50 RPM; Minimum alarm setpoint = 0.4 RPM Sensor Specifications Supply Voltage 12 VDC from 60-200 monitor Nominal Sensor to Target Range 60-22H Sensor (30 mm dia.): 10 mm (0.394 in) 60-22L Sensor (12 mm dia.): 5 mm (0.197 in) Detection Indicator LED lights when iron target in range of sensor. Helpful in adjusting sensor position and for troubleshooting sensor or wiring failures. Cable 3 wire, oil resistant thermoplastic, 20 ft standard Sensor Material Threaded barrel is chrome plated brass, plastic face is PA12-GF3. Metric threads. Bracket Material Chrome plated brass 1 The dual channel 60-200-2 model (only) has a power transformer that is adaptable to other voltages and frequency power supplies that are found outside of the USA. 2 Applies to 60-200-2 only 2008 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. Results may vary under different operating conditions. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representatives for details. Literature Code PI.8043.0408 Process Instruments Australia +61 (0) 8 8208-8200 +61 (0) 8 8234-3772 fax Canada +1 (905) 888-8808 +1 (905) 888-8828 fax Chile +56 (0) 2-335-3388 +56 (0) 2-335-1590 fax China +86 (0) 21 6865 4588 +86 (0) 21 6445 7830 fax Germany +49 (0) 208-824930 +49 (0) 208-852310 fax India +91 (20) 6626 7000 +91 (20) 6626 7001 fax Italy +39 02-959514-1 +39 02-953200-15 fax Netherlands +31 (0) 76-579-5555 +31 (0) 76-571-4958 fax Poland +48 (0) 22 651 7530 +48 (0) 22 651 7535 fax South Africa +27 (0) 11-609-3101 +27 (0) 11-609-3110 fax Spain +34 (0) 91-484-5965 +34 (0) 91-484-3597 fax United Kingdom +44 (0) 1788-820300 +44 (0) 1788-820301 fax United States +1 (800) 227-8891 +1 (763) 783-2525 fax +1 (763) 783-2500 direct www.thermo.com/bulk-handling