Customer id 2452 Project 1152 Unit 189 ACON From Inspection Side. Unit name AHU-22 R.05 Supply air EU m³/sec Exhaust air

Similar documents
ErP - COMPLIANT TO EUROPEAN DIRECTIVE VENTILATION UNITS (AHU) TECHNICAL DATA RIGHT VIEW TOP VIEW

KOMFORT EC DB Suspended heat recovery air handling units

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

Eco Active H E A T R E C O V E R Y S Y S T E M S. Heat Recovery Penthouse Turret. W: T:

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

AIR HANDLING UNITS ASSET REFERENCE: DESIGN AHU 1 AHU 2

EHH SERIES DRAW THROUGH FAN COILS CFM

YMA Air Handling Units

Centeral Station Air Handling Unit

SAM. Small Air Handling. VES SMALL AIR HANDLERS part of a complete range of innovative, flexible products from the HVAC experts

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

Series VENTS MPA...W. Supply units with the air capacity up to 6500 m 3 /h in the compact sound- and heat-insulated casing with water heater

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

Heat Recovery Unit HERU. web-version

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

AIR HANDLING UNITS MANDÍK

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

MODEL: ACWD CEILING CONCEALED Chilled Water Fan Coils Unit

TopMaster Air Handling unit. Technical data

Product catalogue Air handling units. Easy and flexible solutions for any ventilation requirements

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

Series VENTS VUT R WH ЕС

for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning

39G Air Handling Unit

Framework is anodised aluminium with airtight door seals and manual door catches which can be tool locked in position.

1 - Donkin Fans. Majax-2 Aerofoil Axial Flow Fans

UNITES TERMINALES ET MINI CTA FIDJI

Residential Heat Recovery Ventilation. REHVA European Guidebook No 25

LOW STATIC HYDRONIC DUCTED UNIT

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

made of expectations Mech-Elec. Air Handling Units

Air Handling Units. direct drive - belt drive - custom built

COMPACT AIR HANDLING UNIT. CompAir RW. Technical Brochure

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

13 HYGENIC AIR HANDLING UNITS

Introduction to Fans. The Basics of Fan Principles and Terminology

VERSO Air Handling Units

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

The ultimate in air handling units: directly and indirectly fired

YAH SERIES FAN COIL UNITS

CLIMASTER ZCF AIR HANDLING UNITS

ROOFMASTER STEF-HT ROOF FAN

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

GLEC exhaust FAN. Air Comfort. Air movement. Duct & Box Fans

Highly Efficient,Powerful Heating and Cooling.

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY

HEATING & COOLING COIL PRODUCTS

NKW. Heater series HEATERS

GOLD RX, GOLD RX 12 GOLD RX,

Superchiller Product Documentation. English. cod rev Issued by TDS

The ultimate in air handling units: directly and indirectly fired

Signs + or - The desired duty point lies for fans with preceding + sign, outside its optimum using area. It is recommended to use a bigger fan size.

products 22 º C Ventilation Air Conditioning Refrigeration Air-Handling Units DB Inside PROVIDED BY HEINEN & HOPMAN

Double Skin Casing Air Handling Units

CBP - DOUBLE INLET FANS WITH FORWARD CURVED IMPELLERS

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

European Parliament and of the Council with regard to energy labelling of residential ventilation units. (Text with EEA relevance) (2016/C 416/06)

Double Skin Air Handling Units

Heat and energy recovery ventilators

TECHNICAL INFORMATION DanX Swimming Pool Air Management

ISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS

CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS ENERGY-BOX HE

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

MHW Air Handling Unit (50/60Hz)

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

VERSO Air Handling Units

MODULAR AIR HANDLING UNIT. Models: FAC / FMC / FBC

CYLINDRICAL CASED AXIAL FLOW FANS. Cylindrical cased axial flow fans TCBB. Corrosion resistance. Impeller dynamically balanced.

VERTICAL AHU ENGINEERING SPECIFICATIONS BULLETIN

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

GLOBAL LP. Ceiling-mounted ventilation unit with plate heat exchanger

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil

Adsolair 56/58. Comfort air conditioning unit with double plate heat exchanger and adiabatic evaporative cooling system

AIR HANDLING UNITS Vibration Isolation Air Filtration Equipment Ductwork.

OPERATION AND MAINTENANCE MANUAL

VMA-VMB NOVA AIR HEATERS. NoVa air heaters

REKO heat recovery units REKO HEAT RECOVERY UNITS TYPE A TYPE D

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

Transformer oil coolers BETA & CETA

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers

PRODUCT RANGE: ROOFTOP PACKAGE

Selecting the Correct Fan

VRV+AHU System DAIKIN NEW STANDARD SERIES UNIT MODEL AHUR-CA/SA

CUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams

AIR HANDLING UNITS RIS P EKO 3.0. New range - 5 sizes, 20 models! Efficient EC. E f f i c i e n c y up to 94%! E x t r e m e l y low height! fans!

66 on. Central ventilation system ZLS-DV EC according to DIN Central ventilation system ZLS EXTRACT AIR FIRE PROTECTION OUTSIDE AIR

Lo-Carbon Sentinel Kinetic Horizontal

The ultimate in air handling units: directly and indirectly fired

technical data Fan coil unit FWB small duct unit

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

VEX100 series Air handling units with cross-flow heat exchanger

Transcription:

From Inspection Side 2018-10-27 Acon 2.7.130319.1 Page 1/11 Customer id 2452 Project 1152 Unit 189 Project name JSL Prosafe GVA 3000E AU Unit name AHU-22 R.05 Supply air EU-21 1.13 m³/sec Exhaust air

From Above 2018-10-27 Acon 2.7.130319.1 Page 2/11 Customer id 2452 Project 1152 Unit 189 Project name JSL Prosafe GVA 3000E AU Unit name AHU-22 R.05 Supply air EU-21 1.13 m³/sec Exhaust air

Isometric South West 2018-10-27 Acon 2.7.130319.1 Page 3/11 Customer id 2452 Project 1152 Unit 189 Project name JSL Prosafe GVA 3000E AU Unit name AHU-22 R.05 Supply air EU-21 1.13 m³/sec Exhaust air

Size 21 Page 4/11 Customer Customers ref. Our ref. Allan Escalona Supply air volume flow rate 1.13 m³/sec Exhaust air volume flow rate 0.00 m³/sec External static pressure 500 Pa External static pressure 0 Pa Voltage 3 x 690V + N, 60 Hz Weight 496 kg Specific electric power demand 1.50 kw/(m³/s) Dimensioned for wet condition Ref. density 1.2 kg/m³ Ref. altitude above sea level 0 m SUMMARY Functional sections in direction of air flow v0 (m/s) Et (%) tw ( C) ts ( C) dp* (Pa) Connection section 0.0 0 Inspection section 0 Filter 2.2 60 Inspection section 0 Air heater 2.2-20 / 12 21 Air cooler 2.0 28 / 12 100 Centrifugal fan 68.3 21.7 / 23 12 / 13.3 775 Fan system effect 94 Supply outlet 500 *Refers to the fan design case SOUND POWER LEVELS (standard: EN13053 ISO/CD 13347-2) Lw per octave band (db) LwA Octave band (Hz) 63 125 250 500 1k 2k 4k 8k db(a) Fresh air connection 76 79 79 84 75 69 61 50 83 Supply air connection 88 92 88 89 82 82 77 69 90 To surroundings 71 73 66 61 56 51 45 32 64

Size 21 Page 5/11 Customer Customers ref. Our ref. Allan Escalona Supply air volume flow rate 1.13 m³/sec Exhaust air volume flow rate 0.00 m³/sec External static pressure 500 Pa External static pressure 0 Pa Voltage 3 x 690V + N, 60 Hz Weight 496 kg Specific electric power demand 1.50 kw/(m³/s) Dimensioned for wet condition Ref. density 1.2 kg/m³ Ref. altitude above sea level 0 m SUMMARY TECHNICAL SPEC. Unit Supply air volume flow rate 1.13 m³/sec Installation Indoor horizontal External static pressure 500 Pa Material stainless sheet steel (AISI 304) Internal static pressure 275 Pa Thermal insulation T3 Condensation insulation TB3 Leakage class L3 Casing strength CEN D2 Design outdoor temperature summer 28 C Filter grade supply G3 Dim. humidity summer 80 % Filter grade extract Design outdoor temperature winter -20 C Dim. humidity winter 99.9 % Temperature in, supply air, summer 13 C Temperature in, extract air, summer 26 C Air humidity in, supply air, summer 99.9 % Air humidity in, extract air, summer 55 % Temperature in, supply air, winter 23 C Temperature in, extract air, winter 18.5 C Air humidity in, supply air, winter 40 % Air humidity in, extract air, winter 40 % Mixing ratio at winter design temperature 0 % Temperature efficiency (EN308) 0.0 % Heat recovery capacity 0.00 kw SFPv supply air 1.50 kw/(m³/s) Total dry weight 496 kg SFPv total sum 1.50 kw/(m³/s) Heaviest block 306 kg ErP (according to (EU) directive 1253/2014) The AHU needs to be checked manually regarding ErP-directive due to selected non-standard components. Coils Capacity [kw] Air In [ C/%] Air Out [ C/%] Water in/out [ C] Antifreze Water [l/s] Water [kpa] Conn [mm] Air heater 43.6-20/99.9 12/7.4 120/91.2 0.38 20.3 25 Air cooler 58.2 28/80 12/99.8 6/12 Ethylene glycol 20 Antifreze 2.42 72.1 32 Fan power supply data Voltage Power, supply flow Current, full load, supply flow 3 x 690V + N, 60 Hz 2.2 kw 2.6 A SOUND POWER LEVELS (standard: EN13053 ISO/CD 13347-2) Lw per octave band (db) LwA Octave band (Hz) 63 125 250 500 1k 2k 4k 8k db(a) Fresh air connection 76 79 79 84 75 69 61 50 83 Supply air connection 88 92 88 89 82 82 77 69 90 To surroundings 71 73 66 61 56 51 45 32 64

Size 21 Page 6/11 TECHNICAL SPECIFICATION (components listed in direction of air flow) SUPPLY AIR End connection frame Variant: without opening Panel material: 0.7 mm stainless sheet steel AISI 304 Pressure drop, dimensioning Empty section Length, mm: 500 (Sizes 11-53) 550 (Sizes 60-84) Duct connection: at the top Inspection side: right-hand Damper for EUTC Length, mm (EUTC): Sizes 11-53 500 Sizes 60-84 550 Location: top/bottom Damper type: stainless sheet steel CEN 3 damper Connection: Flanged joint EUVA-21-7-0-5-0 0 Pa EUTC-21-5-1-0-1 EUTZ-01-21-5-1-5-2 Short bag filter EUPB-21-03-3-1-2-1 Filter type: class G3, synthetic Filter bag length: 400 long, filter bag/compact 360/290 mm Filter frame: galvanized sheet steel Material: stainless sheet steel Inspection side: right-hand Number of filters 1 x (1/1) + 1 x (1/2) Pressure drop, start 32 Pa Pressure drop, dimensioning 67 Pa Pressure drop, end 102 Pa Face area 0.5 m² Face velocity 2.2 m/s Differential pressure guage (Dwyer magnehelic) EUPZ-25-3-2 Pressure range: 0-500 Pa Arrangement: bracket mounted on panel Water trap, negative pressure - 800 Pa, stainless EUMZ-02-1 steel Empty section Length, mm: 100 (Sizes 11-53) 150 (Sizes 60-84) Inspection side: right-hand EUTC-21-1-0-0-1 Air heater for hot water EUEE-21-2-02-1-4-2-1 Output variant: 2 Material, coil: Cu/Cu Version: one complete coil Material, frame: stainless sheet steel Connection side: right-hand Nom. pipe size 25 Liquid volume 3.0 l Pressure drop, dimensioning, Winter 22 Pa Output 43.6 kw Air temperature -20 / 12 C Face velocity 2.2 m/s Control principle for water heater flow control

Size 21 Page 7/11 Water temperature 120 / 91.2 C Water flow 0.38 l/s Water velocity 1.5 m/s Pressure drop water 20.3 kpa Automatic air purging valve EUAZ-19 Air cooler for chilled water EUNN-21-6-5-2-01-1-2-1 Output variant: 6 Coil version: max face area, extension frame in stainless sheet steel Fin pitch and connection: 2,5 mm normal Material, coil: Cu/Al Droplet eliminator: with, plastic Material, frame: stainless sheet steel Connection side: right-hand Nom. pipe size 32 Liquid volume 16.0 l Ethylene glycol 20 % Pressure drop, dimensioning 100 Pa Pressure drop, wet coil 132 Pa Pressure drop, dry coil 88 Pa Output 58.2 kw Air temperature 28 / 12 C Relative humidity 80 / 99.8 % Face velocity 2.0 m/s Water temperature 6 / 12 C Water flow 2.42 l/s Water velocity 1.9 m/s Pressure drop water 72.1 kpa Water trap, negative pressure - 800 Pa, stainless EUMZ-02-1 steel Automatic air purging valve EUAZ-19 Insulated drain tray EUNZ-01-21-2 Coil version: max face area Radial fan. belt-driven EULR-21-1-1-3-2-05-1-1-3 Fan size: size 1 Impeller type: normal impeller, backward curved Equipment: spark-proof design Material: stainless sheet steel (epoxy painted casing and impeller) Inlet and outlet: Inlet end wall, outlet end wall, lower edge Motor location: one motor, internal, rubber anti-vibration mounting Inspection side: right-hand Dimensioning data Speed 3498 Rpm Max speed 4500 Rpm Fan efficiency 68.3 % Total efficiency 50.1 % Pressure drop, dimensioning 775 Pa Fan shaft power at dim. data 1.29 kw Fan system input power (absorbed electrical 1.75 kw power) Temperature rise 1.3 C Fan wheel size 025 SFP Calculation Specific fan power 1.50 kw/(m³/s) Fan system input power (absorbed electrical 1.69 kw power) according to SFP

Size 21 Page 8/11 Pressure rise 746 Pa Speed 3456 Rpm Belt drive Efficiency 92.9 % Motor Efficiency 83.2 % Speed 2880 Rpm Motor output 2.2 kw Electric current 2.6 A Number of Poles 2 Output margin, minimum 10 % Frequency converter Efficiency 95.0 % Single-speed motor APAL-2-00220-2-2-X (X = estimated only, VFD enabled) Voltage: 380-420 V delta, 660-690 V star Temperature sensors in stator winding: with thermistor Design variant: FläktGroup IE2 Inspection window EUAZ-01-4 Version: double glazed, 2009 Belt drive for EULR fan EULS-21-1-1-1-0-3499-1-0-3 Impeller type: normal impeller, backward curved Version: standard v-belt Fan speed: 3499 Motor location: one motor, internal, rubber anti-vibration mounting Bulkhead light EUAZ-09-21-1 Type: wired to switch outside casing Earth cable EULZ-26 Protective screen door EULZ-24-21-2 Material: stainless sheet steel Cable gland EULZ-48-25-2 Unit size: M25 12,5-15,0 mm Mounting: assembled according to FWG standard Duct connection piece EULZ-62-21-1-1-2-2-X-3 (X=1,but acc to ISO15138 (NORSOK)) Connection type: flanged joint Material: stainless sheet steel Connection location: end wall outlet

Size 21 Page 9/11 PRODUCT LIST Qty. Product Product code 1 Unit casing (standard, indoor version) EUGA-21-180-1-5-1-1-0 1 Base frame EUAZ-04-21-180-1-1-1 1 End connection frame EUVA-21-7-0-5-0 1 Empty section EUTC-21-5-1-0-1 1 Damper for EUTC EUTZ-01-21-5-1-5-2 1 Short bag filter EUPB-21-03-3-1-2-1 1 Differential pressure guage (Dwyer EUPZ-25-3-2 magnehelic) 1 Water trap, negative pressure - 800 Pa, EUMZ-02-1 stainless steel 1 Empty section EUTC-21-1-0-0-1 1 Air heater for hot water EUEE-21-2-02-1-4-2-1 1 Automatic air purging valve EUAZ-19 1 Air cooler for chilled water EUNN-21-6-5-2-01-1-2-1 1 Water trap, negative pressure - 800 Pa, EUMZ-02-1 stainless steel 1 Automatic air purging valve EUAZ-19 1 Insulated drain tray EUNZ-01-21-2 1 Unit casing (standard, indoor version) EUGA-21-110-1-5-1-1-0 1 Base frame EUAZ-04-21-110-1-1-1 1 Radial fan. belt-driven EULR-21-1-1-3-2-05-1-1-3 1 Single-speed motor, X = estimated only, APAL-2-00220-2-2-X VFD enabled 1 Belt drive for EULR fan EULS-21-1-1-1-0-3499-1-0-3 2 Cable gland EULZ-48-25-2 1 Inspection window EUAZ-01-4 1 Bulkhead light EUAZ-09-21-1 1 Earth cable EULZ-26 1 Protective screen door EULZ-24-21-2 1 Duct connection piece, X=1,but acc to ISO15138 (NORSOK) EULZ-62-21-1-1-2-2-X-3

Size 21 Page 10/11 PART PRICES Qty. Product Product code Price each 1 Unit casing (standard, indoor version) EUGA-21-180-1-5-1-1-0 16214 1 Base frame EUAZ-04-21-180-1-1-1 1687 1 End connection frame EUVA-21-7-0-5-0 1208 1 Empty section EUTC-21-5-1-0-1 803 1 Damper for EUTC EUTZ-01-21-5-1-5-2 2221 1 Short bag filter EUPB-21-03-3-1-2-1 1836 1 Differential pressure guage (Dwyer EUPZ-25-3-2 2007 magnehelic) 1 Water trap, negative pressure - 800 Pa, EUMZ-02-1 3802 stainless steel 1 Empty section EUTC-21-1-0-0-1 268 1 Air heater for hot water EUEE-21-2-02-1-4-2-1 8771 1 Automatic air purging valve EUAZ-19 515 1 Air cooler for chilled water EUNN-21-6-5-2-01-1-2-1 16205 1 Water trap, negative pressure - 800 Pa, EUMZ-02-1 3802 stainless steel 1 Automatic air purging valve EUAZ-19 515 1 Insulated drain tray EUNZ-01-21-2 1225 1 Unit casing (standard, indoor version) EUGA-21-110-1-5-1-1-0 12312 1 Base frame EUAZ-04-21-110-1-1-1 1561 1 Radial fan. belt-driven EULR-21-1-1-3-2-05-1-1-3 7261 1 Single-speed motor, X = estimated only, APAL-2-00220-2-2-X 5506* VFD enabled 1 Belt drive for EULR fan EULS-21-1-1-1-0-3499-1-0-3 1342 2 Cable gland EULZ-48-25-2 346 1 Inspection window EUAZ-01-4 350 1 Bulkhead light EUAZ-09-21-1 1320 1 Earth cable EULZ-26 328 1 Protective screen door EULZ-24-21-2 1068 1 Duct connection piece, X=1,but acc to ISO15138 (NORSOK) EULZ-62-21-1-1-2-2-X-3 1501* Total SGOPA (Map: 32) 94320 Mark up factor 1.00 0 Freight cost 1.00 0 Total amount 94320 SEK

Size 21 Page 11/11 Fan chart - Supply air - EULR-21-1-1-3-2-05-1-1-3