Power packs TectoRack. Energy-saving and ecological CO2 power packs

Similar documents
Freezer and cooler islands TectoFreeze IS1. Reliable islands for chilled and frozen food

TopTechnology. TectoPromo FL2 Aida Versatile serve-over display cabinet for bakery products

Multideck cabinet. TectoDeck MD2 e-ventus. A multideck breakthrough in energy efficiency

Upright freezer cabinet TectoFreeze VF1 Luxo. High volume freezer line. Heating systems Industrial systems Refrigeration systems

Multidecks TectoDeck MD4 Leho TectoDeck RI4 Leho. Energy efficiency with a system

Multideck cabinets TectoDeck MD 3 e-visio. Two multideck cabinets in one. Heating systems Industrial systems Refrigeration systems

Semi-vertical multideck TectoDeck SV2. A space-efficient semi-vertical multideck. Heating systems Industrial systems Refrigeration systems

Multideck cabinets TectoDeck MD5. Energy-efficient high-performance multideck. Heating systems Industrial systems Refrigeration systems

Multideck cabinet. Effective and versatile display cabinet. TectoDeck MD1 Spirit Plus. Heating systems Industrial systems Refrigeration systems

Versatile front line display cabinet for bakery products

Maximised display area for chilled food and beverages

Energy efficiency with a system

Upright freezer cabinet LUXO. High volume freezer line. Heating systems Industrial systems Refrigeration systems

Installation and Operating Instructions

Premium freezers combining functionality, elegance and energy efficiency

Refrigeration Systems Handbook

Press Release. Short profile Beckhoff. Short profile February 2009 Page 1 of 6

Beckhoff short profile

TRENDS IN RETAIL INDUSTRY REFRIGERATION & REVIEW OF EUROSHOP 2017 EXHIBITION

SOLID BIOFUELS - METHODS FOR

CONFORMITY ASSESSMENT - SUPPLIER'S

Sterilization of health care products - Moist heat - Part 2: Guidance on the application of ISO (ISO :2009)

STT 3000 Series STT250 /150 Surge Protection Device Specifications

HEXALOBULAR INTERNAL DRIVING FEATURE FOR BOLTS AND SCREWS (ISO 10664:2005) IRISH STANDARD I.S. EN ISO 10664:2005. Price Code

This document is a preview generated by EVS

ISO 7458 INTERNATIONAL STANDARD. Glass containers Internal pressure resistance Test methods

ELECTRICAL AND INSTRUMENTATION LOOP CHECK (IEC 62382:2006 (EQV)) IRISH STANDARD I.S. EN 62382:2007. Price Code

LABORATORY GLASSWARE - GRADUATED MEASURING CYLINDERS (ISO 4788:2005) IRISH STANDARD I.S. EN ISO 4788:2005. Price Code

ISO INTERNATIONAL STANDARD. Glass containers Vacuum lug finishes Part 1: General

Cold and deep-freezing room solutions

Heating with pellets kw

REFRIGERATING SYSTEMS AND HEAT

FF-SR Series. FF-SR25933 Two-hand Safety Control Module FF-SR25933

English version. Alarm systems Terms and definitions

List of nationally authorised medicinal products

ISO INTERNATIONAL STANDARD. Adhesives for thermoplastic piping systems Part 1: Determination of film properties

REFRIGERATING SYSTEMS AND HEAT

compact BOOSTER RACK TRANSCRITICAL CO 2 Cooling capacity LT: from 2 to 130 kw Cooling capacity MT: from 20 to 300 kw

ILNAS-EN ISO :2005

CLEAR LIQUIDS - ESTIMATION OF COLOUR BY THE GARDNER COLOUR SCALE - PART 1: VISUAL METHOD (ISO :2004) IRISH STANDARD I.S. EN ISO :2005

NATURAL GAS - CALCULATION OF

ISO INTERNATIONAL STANDARD. Steel cord conveyor belts Part 4: Vulcanized belt joints

WATER QUALITY - CRITERIA FOR

COMMUNICATION SYSTEMS FOR AND REMOTE READING OF METERS - PART 2: PHYSICAL AND LINK LAYER IRISH STANDARD I.S. EN :

PLASTICS - DETERMINATION OF THE MELT

Certificate of constancy of performance,

Type 2 safety light curtain Type 2 according to the IEC/EN parts 1 and 2 Compact profile: 31 x 32 mm 30 mm resolution for hand detection Wide r

Paper and board - Determination of grammage (ISO 536:2012)

This document is a preview generated by EVS

This document is a preview generated by EVS

PISTON-OPERATED VOLUMETRIC

Founding - Magnetic particle testing

BIOLOGICAL EVALUATION OF MEDICAL

ILNAS-EN ISO 10684:2004

PACKAGING - REQUIREMENTS FOR PACKAGING RECOVERABLE BY MATERIAL RECYCLING STANDARD I.S. EN 13430:2004. Price Code

This document is a preview generated by EVS

This document is a preview generated by EVS

Resilient, textile and laminate floor coverings - Classification (ISO 10874:2009)

Environmentally friendly systems for convenience stores

This document is a preview generated by EVS

ILNAS-EN ISO 2692:2006

English Version. Office furniture - Office work chair - Part 4: Clarifications to EN :2000 (Dimensions)

ISO INTERNATIONAL STANDARD. Glass containers Vacuum lug finishes Part 12: 89 regular

This document is a preview generated by EVS


The advantages of closed heating systems. White paper

This document is a preview generated by EVS

This document is a preview generated by EVS

This document is a preview generated by EVS

This document is a preview generated by EVS

ISO/TS TECHNICAL SPECIFICATION. Geotechnical investigation and testing Laboratory testing of soil Part 6: Fall cone test

This document is a preview generated by EVS

PETROLEUM AND NATURAL GAS

This document is a preview generated by EVS

SANS 21-1:2009 Edition 1 EN 115-1:2008

PTG, SWT Series. Heat Recovery Systems

This document is a preview generated by EVS

This document is a preview generated by EVS

ISO INTERNATIONAL STANDARD. Footwear Test methods for accessories: Touch and close fasteners Peel strength before and after repeated closing

Log fired heating system

Sýnishorn ISO INTERNATIONAL STANDARD. Geotechnical investigation and testing Field testing Part 3: Standard penetration test

SVENSK STANDARD SS-EN ISO 15652:2005. Båtar Styrsystem för småbåtar med inombordsvattenjetmotorer

ALARM SYSTEMS - INTRUSION AND

Type Approvals GARAGE DOOR OPENER RADIO TRANSCEIVER. (EuroHomeLink 2000) Czech Republic CTU R 1194 Cyprus MCW129/95 12/2000 Denmark 98.

Massa Våtuppslagning på laboratoriet Del 1: Våtuppslagning av kemisk massa (ISO :2004)

Office furniture - Office work chair - Part 2: Safety requirements

This document is a preview generated by EVS

Refrigeration Systems 2011

ISO INTERNATIONAL STANDARD. Footwear Test methods for outsoles Flex resistance

Heating with wood chips & pellets

Cylindrical helical springs made from round wire and bar - Calculation and design - Part 1 : Compression springs

SVENSK STANDARD SS-EN ISO 13897:2005. Tandvård Amalgamkapslar (ISO 13897:2003) Dentistry Amalgam capsules (ISO 13897:2003)

Saving the world and reducing energy costs with advanced CO 2 systems

ISO INTERNATIONAL STANDARD. Acoustics Measurement of sound pressure level from service equipment in buildings Engineering method

This document is a preview generated by EVS

Large variety small footprint

Aerospace series - Quality systems - First article inspection requirements

COOL 1. Service manual

Transcription:

Power packs TectoRack Energy-saving and ecological CO2 power packs

TectoRack

2/3 The energy-efficient power pack for medium and low temperature refrigeration applications Using full refrigeration capacity and saving costs with the natural refrigerants TectoRack refrigeration system has been optimally designed to meet the requirements of supermarkets, discounters, convenience stores and other refrigeration systems with medium and low temperature refrigeration capacity. The turnkey solution for indoor and outdoor installation contains all relevant CO2 refrigeration components including a highquality controller system and heat recovery - integrated in a highly compact, space-saving housing. This ensures flawless operation from the very beginning including easy installation and maintenance. Choose the scope of sound insulation based on the application and installation situation. TectoRack M Thanks to the smart and compact design, with TectoRack you can replace the traditional machine room. The compact indoor version without sound installation requires just one euro-pallet space (820x1250 mm). Take advantage of these benefits Several years of international experience in the field of transcritical CO2 systems System solutions for all areas of application High degree of hermetic sealing Short delivery times TÜV-compliant system technology

Technical specifications - TectoRack S 45-75 kw SR / 0-14.5 kw FR Up to 3 MT compressors (one with frequency inverter) Up to 2 LT compressors (optionally one with frequency converter) 60 bar medium pressure receiver, 75 liter Switchboard included completely tested Pipeline connection at one point minimum installation effort Possibility to demount the rack in 4 pieces - onsite Minimum installation space extremely compact TectoRack S Installation Indoor installation, without sound enclosure Indoor installation, 50 mm sound enclosure Outdoor installation, 40 mm sound enclosure Outdoor installation, 100mm sound enclosure * plus 10 cm tube connections Cooling Sound level reduction (db(a)) Max. weight Dimensions (mm) (ca. kg) Depth Height Width - 1150 900 1904 1810-8 1500 920 1954 1870-8 1800 1040 1944 2045-12 2100 1200 2410 2200 Number of compressors Q 0 min Capacity Medium temperature 2-3 45 75 Low temperature 0-2 0 14.5 Capacity t GCoutlett 34 C, SR / FR = -8 C / -32 C Q 0 max

Technical specifications - TectoRack M 4/5 45-160 kw SR / 0-27 kw FR Very easy to use (without complicating functions) Up to 4 MT compressors (optionally one with frequency inverter) Up to 3 LT compressors (optionally one with frequency inverter) 60 bar medium pressure receiver, 105-165 liter Switchboard included - completely tested Possibility to demount the rack in 3 pieces on- site TectoRack M Installation Cooling Number of compressors Q 0 min Capacity Medium temperature 3-4 45 160 Low temperature 0-3 0 27 Capacity t GCoutlett 34 C, SR / FR = -8 C / -32 C Collector size (litres) Max. weight Dimensions (mm) (ca. kg) Depth Height Width 3 SR compressors 115 1300 800 1950 2430 4 SR (or 3) compressors 165 1700 800 1950 2860 Q 0 max

Technical specifications - TectoRack L 100-290 kw SR / 0-60 kw FR Up to 6 MT compressors (one with frequency inverter) Up to 5 LT compressors (optionally one with frequency inverter) 60 bar medium pressure receiver, 165-250 liter Switchboard included - completely tested Possibility to demount the rack in 2 pieces - on site Insulation of all cold parts Suction line filter formt and LT TectoRack L Installation Dimensions (mm) Depth (A) Height (B) Width (C) Width Intermediate pressure station (D) 3 SR + 0-2 FR 890 1995 3040 1000 4 SR + 0-3 FR 890 1995 3720 1000 5 SR + 0-4 FR 890 1995 4200 1000 6 SR + 0-5 FR 890 1995 4880 1000 Cooling Number of compressors Q 0 min Capacity Medium temperature 3-6 100 290 Low temperature 0-5 0 60 Capacity t GCoutlett 34 C, MT / LT = -8 C / -32 C Q 0 max

Accessories 6/7 TectoRack S Heat recovery circuit 1 into water with plate heat exchanger and 3-directional bypass valve Heat recovery circuit 2 into water with plate heat exchanger and 3-way bypass valve for on-site installation Insulation against heat loss (warm side) Receiver min. level control Frequency inverter LT-compressor (one) Weather enclosure - with or without sound insulation Second high- and medium pressure valve Standstill cooling unit (on-site installation) TectoRack M Heat recovery circuit 1 into water with plate heat exchanger and 3-way bypass valve Heat recovery circuit 2 against water with plate heat exchanger and 3-way bypass valve for onsite installation Insulation against heat loss (warm side) Receiver min. level control Frequency inverter LT compressor (one) Weather enclosure - with or without sound insulation Second high- and medium pressure valve Standstill cooling unit (on-site installation) TectoRack L Heat recovery circuit 1 into water with plate heat exchanger and 3-way bypass valve Heat recovery circuit 2 into water with plate heat exchanger and 3-way bypass valve Improvement of heating capacity - gas cooler bypass Insulation against heat loss (warm side) Heat exchanger for superheating and subcooling (optional) Receiver min. level control Frequency inverter LT compressor (one) Suction design pressure increase up to 60 bar MT and LT Heat pump and air conditioning features Parallel compression and ejectors EVALIFT Second high- and medium pressure valve Standstill cooling unit (on-site installation)

Austria Viessmann Kühlsysteme Austria GmbH Telephone +43 72 35 66367-0 office_vk_at@viessmann.com kuehlen.viessmann.at Latvia Viessmann Refrigeration Systems Latvia filiále Telephone +371 6782 8449 info.lv@viessmann.com Refrigeration systems product catalogue at App store. Belgium Viessmann Nederland B.V. Telephone +31 85 018 7460 info-ref-be@viessmann.com Netherlands Viessmann Nederland B.V. Telephone +31 85 018 7460 info-ref-nl@viessmann.com koelen.viessmann.nl Czech Republic Viessmann, spol. s r.o. Telephone + 420 257 090 900 viessmann@viessmann.cz Norway Viessmann Refrigeration Systems AS Telephone +47 3336 3500 post@viessmann.no kjol.viessmann.no Denmark Viessmann Refrigeration Systems ApS Telephone +45 4120 5420 info.dk@viessmann.com koele.viessmann.dk Poland Viessmann Systemy Chłodnicze Sp. z o.o. Telephone +48 22 882 0020 info.pl@viessmann.com chlodnicze.viessmann.pl Estonia Viessmann Külmasüsteemid OÜ Telephone +372 675 5150 info.ee@viessmann.com kylm.viessmann.ee Russia Viessmann Group Refrigeration Systems Moscow, St. Petersburg Telephone +7 499 277 1260 holod.viessmann.ru Finland Viessmann Refrigeration Systems Oy Telephone +358 19 537 8000 info.fi@viessmann.com Viessmann Kylmäjärjestelmät Oy Telephone +358 19 537 8000 info.fi@viessmann.com kylma.viessmann.fi France Viessmann Technique du Froid S.à.r.l. Telephone +33 3 87 13 08 13 france@viessmann-refrigeration.com froid.viessmann.fr Germany Viessmann Kühlsysteme GmbH, Hof Telephone +49 9281 814-0 Viessmann Kühlsysteme GmbH, Mainz Telephone +49 61315 7046-17 kuehlsysteme@viessmann.de cooling.viessmann.co.uk Slovakia Viessmann, s.r.o. Telephone +421 32 23 01 00 viessmann@viessmann.sk Sweden Viessmann Refrigeration Systems AB Telephone +46 8 5941 1200 info.refrigeration@viessmann.se kyla.viessmann.se Switzerland Viessmann (Schweiz) AG Telephone +41 56 418 67 11 info@viessmann.ch kuehlen.viessmann.ch United Arabian Emirates Viessmann Middle East FZE Telephone +971 43724247 refrigeration@viessmann.ae 9442866 GB 08/2018 Ireland Viessmann Refrigeration Systems Limited Telephone +353 1 617 7930 sales@viessmann-coldtech.ie cooling.viessmann.co.uk United Kingdom Viessmann Refrigeration Systems Limited Telephone +44 1952 457157 sales@viessmann-coldtech.co.uk cooling.viessmann.co.uk The contents of this document are copyright protected. Copies and other usage are subject to prior consent. Subject to modifications.