Power packs TectoRack Energy-saving and ecological CO2 power packs
TectoRack
2/3 The energy-efficient power pack for medium and low temperature refrigeration applications Using full refrigeration capacity and saving costs with the natural refrigerants TectoRack refrigeration system has been optimally designed to meet the requirements of supermarkets, discounters, convenience stores and other refrigeration systems with medium and low temperature refrigeration capacity. The turnkey solution for indoor and outdoor installation contains all relevant CO2 refrigeration components including a highquality controller system and heat recovery - integrated in a highly compact, space-saving housing. This ensures flawless operation from the very beginning including easy installation and maintenance. Choose the scope of sound insulation based on the application and installation situation. TectoRack M Thanks to the smart and compact design, with TectoRack you can replace the traditional machine room. The compact indoor version without sound installation requires just one euro-pallet space (820x1250 mm). Take advantage of these benefits Several years of international experience in the field of transcritical CO2 systems System solutions for all areas of application High degree of hermetic sealing Short delivery times TÜV-compliant system technology
Technical specifications - TectoRack S 45-75 kw SR / 0-14.5 kw FR Up to 3 MT compressors (one with frequency inverter) Up to 2 LT compressors (optionally one with frequency converter) 60 bar medium pressure receiver, 75 liter Switchboard included completely tested Pipeline connection at one point minimum installation effort Possibility to demount the rack in 4 pieces - onsite Minimum installation space extremely compact TectoRack S Installation Indoor installation, without sound enclosure Indoor installation, 50 mm sound enclosure Outdoor installation, 40 mm sound enclosure Outdoor installation, 100mm sound enclosure * plus 10 cm tube connections Cooling Sound level reduction (db(a)) Max. weight Dimensions (mm) (ca. kg) Depth Height Width - 1150 900 1904 1810-8 1500 920 1954 1870-8 1800 1040 1944 2045-12 2100 1200 2410 2200 Number of compressors Q 0 min Capacity Medium temperature 2-3 45 75 Low temperature 0-2 0 14.5 Capacity t GCoutlett 34 C, SR / FR = -8 C / -32 C Q 0 max
Technical specifications - TectoRack M 4/5 45-160 kw SR / 0-27 kw FR Very easy to use (without complicating functions) Up to 4 MT compressors (optionally one with frequency inverter) Up to 3 LT compressors (optionally one with frequency inverter) 60 bar medium pressure receiver, 105-165 liter Switchboard included - completely tested Possibility to demount the rack in 3 pieces on- site TectoRack M Installation Cooling Number of compressors Q 0 min Capacity Medium temperature 3-4 45 160 Low temperature 0-3 0 27 Capacity t GCoutlett 34 C, SR / FR = -8 C / -32 C Collector size (litres) Max. weight Dimensions (mm) (ca. kg) Depth Height Width 3 SR compressors 115 1300 800 1950 2430 4 SR (or 3) compressors 165 1700 800 1950 2860 Q 0 max
Technical specifications - TectoRack L 100-290 kw SR / 0-60 kw FR Up to 6 MT compressors (one with frequency inverter) Up to 5 LT compressors (optionally one with frequency inverter) 60 bar medium pressure receiver, 165-250 liter Switchboard included - completely tested Possibility to demount the rack in 2 pieces - on site Insulation of all cold parts Suction line filter formt and LT TectoRack L Installation Dimensions (mm) Depth (A) Height (B) Width (C) Width Intermediate pressure station (D) 3 SR + 0-2 FR 890 1995 3040 1000 4 SR + 0-3 FR 890 1995 3720 1000 5 SR + 0-4 FR 890 1995 4200 1000 6 SR + 0-5 FR 890 1995 4880 1000 Cooling Number of compressors Q 0 min Capacity Medium temperature 3-6 100 290 Low temperature 0-5 0 60 Capacity t GCoutlett 34 C, MT / LT = -8 C / -32 C Q 0 max
Accessories 6/7 TectoRack S Heat recovery circuit 1 into water with plate heat exchanger and 3-directional bypass valve Heat recovery circuit 2 into water with plate heat exchanger and 3-way bypass valve for on-site installation Insulation against heat loss (warm side) Receiver min. level control Frequency inverter LT-compressor (one) Weather enclosure - with or without sound insulation Second high- and medium pressure valve Standstill cooling unit (on-site installation) TectoRack M Heat recovery circuit 1 into water with plate heat exchanger and 3-way bypass valve Heat recovery circuit 2 against water with plate heat exchanger and 3-way bypass valve for onsite installation Insulation against heat loss (warm side) Receiver min. level control Frequency inverter LT compressor (one) Weather enclosure - with or without sound insulation Second high- and medium pressure valve Standstill cooling unit (on-site installation) TectoRack L Heat recovery circuit 1 into water with plate heat exchanger and 3-way bypass valve Heat recovery circuit 2 into water with plate heat exchanger and 3-way bypass valve Improvement of heating capacity - gas cooler bypass Insulation against heat loss (warm side) Heat exchanger for superheating and subcooling (optional) Receiver min. level control Frequency inverter LT compressor (one) Suction design pressure increase up to 60 bar MT and LT Heat pump and air conditioning features Parallel compression and ejectors EVALIFT Second high- and medium pressure valve Standstill cooling unit (on-site installation)
Austria Viessmann Kühlsysteme Austria GmbH Telephone +43 72 35 66367-0 office_vk_at@viessmann.com kuehlen.viessmann.at Latvia Viessmann Refrigeration Systems Latvia filiále Telephone +371 6782 8449 info.lv@viessmann.com Refrigeration systems product catalogue at App store. Belgium Viessmann Nederland B.V. Telephone +31 85 018 7460 info-ref-be@viessmann.com Netherlands Viessmann Nederland B.V. Telephone +31 85 018 7460 info-ref-nl@viessmann.com koelen.viessmann.nl Czech Republic Viessmann, spol. s r.o. Telephone + 420 257 090 900 viessmann@viessmann.cz Norway Viessmann Refrigeration Systems AS Telephone +47 3336 3500 post@viessmann.no kjol.viessmann.no Denmark Viessmann Refrigeration Systems ApS Telephone +45 4120 5420 info.dk@viessmann.com koele.viessmann.dk Poland Viessmann Systemy Chłodnicze Sp. z o.o. Telephone +48 22 882 0020 info.pl@viessmann.com chlodnicze.viessmann.pl Estonia Viessmann Külmasüsteemid OÜ Telephone +372 675 5150 info.ee@viessmann.com kylm.viessmann.ee Russia Viessmann Group Refrigeration Systems Moscow, St. Petersburg Telephone +7 499 277 1260 holod.viessmann.ru Finland Viessmann Refrigeration Systems Oy Telephone +358 19 537 8000 info.fi@viessmann.com Viessmann Kylmäjärjestelmät Oy Telephone +358 19 537 8000 info.fi@viessmann.com kylma.viessmann.fi France Viessmann Technique du Froid S.à.r.l. Telephone +33 3 87 13 08 13 france@viessmann-refrigeration.com froid.viessmann.fr Germany Viessmann Kühlsysteme GmbH, Hof Telephone +49 9281 814-0 Viessmann Kühlsysteme GmbH, Mainz Telephone +49 61315 7046-17 kuehlsysteme@viessmann.de cooling.viessmann.co.uk Slovakia Viessmann, s.r.o. Telephone +421 32 23 01 00 viessmann@viessmann.sk Sweden Viessmann Refrigeration Systems AB Telephone +46 8 5941 1200 info.refrigeration@viessmann.se kyla.viessmann.se Switzerland Viessmann (Schweiz) AG Telephone +41 56 418 67 11 info@viessmann.ch kuehlen.viessmann.ch United Arabian Emirates Viessmann Middle East FZE Telephone +971 43724247 refrigeration@viessmann.ae 9442866 GB 08/2018 Ireland Viessmann Refrigeration Systems Limited Telephone +353 1 617 7930 sales@viessmann-coldtech.ie cooling.viessmann.co.uk United Kingdom Viessmann Refrigeration Systems Limited Telephone +44 1952 457157 sales@viessmann-coldtech.co.uk cooling.viessmann.co.uk The contents of this document are copyright protected. Copies and other usage are subject to prior consent. Subject to modifications.