INSTALLATION MANUAL. ACL TC 200 Pilotless Burner Control System

Similar documents
ACL TC 200 TEMPERATURE CONTROLLER

TMC. Installation and Operation Manual TMC. Temperature and Pressure Monitoring for Heating and Cooling Applications. Temperature Monitoring Control

Installation and Operations Manual

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS

GASGUARD LEL 3 OPERATING & INSTALLATION MANUAL

Trinity Tft High Efficiency Gas Condensing Boiler & Water Heater

Interrupted Ignition Series Oil Primary Control

B-40/B-41 Modulating Temperature Controller

Trinity Lx400 High Efficiency Gas Condensing Boiler & Water Heater

DIVISION FINNED WATER-TUBE BOILERS

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

DIVISION FINNED WATER-TUBE BOILERS

INSTALLATION INSTRUCTIONS

DIVISION FINNED WATER-TUBE BOILERS

Installation Manual. THM-0100 Setpoint Thermostat Version THM HBX Control Systems Inc.

Trinity Lx200 High Efficiency Gas Condensing Boiler & Water Heater

DIVISION FINNED WATER-TUBE BOILERS

Installation Manual. Expansion Module 0100 Version 1.0 EXP HBX Control Systems Inc.

Project Name: Location: Engineer: Contractor: I. GENERAL

INSTALLATION INSTRUCTIONS FOR SERIES 9 INTERMITTENT PILOT IGNITION CONTROL

C1050ES Tankless Water Heater

AFUE 95% Heating Input 50,000 to 200,000 Btuh

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

Pump-Down Controller MODEL 4052

RK Combustible Gas Transmitter Operator s Manual

RK Transmitter Technical Notice

DIVISION FINNED WATER-TUBE WATER HEATERS

MBCE-110/230FR Flame Sensor Module

MS4PMUHVT Multi-Stage Electronic Temperature Control with Relay Pack

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

WM3000 WIRELESS MODULES

Intelligent Electronic Enclosure Thermal Management Systems

ONX908PIT-V1-S1-F1/B Modulating Digital Thermostat

Explosion Proof Line Powered Telephone Ringer

southbend A MIDDLEBY COMPANY INSTALLATION AND OPERATION MANUAL CG214 (E) CG314 (E) CG414 (E) CG220 (E) CG320 (E) CG325 (E) GAS BOILERS MODELS:

Max HT Air Heater FOR SAFETY & LONG HEATER LIFE, CAREFULLY READ THIS MANUAL BEFORE USE.

Pump-Up Controller MODEL 4062

RK Carbon Monoxide Transmitter Operator s Manual

UDC100 Universal Digital Controller Specifications

A. Product Data: Include rated capacities, furnished specialties and accessories.

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

Product Specifications Warning Light Control Cabinet

DIESEL Engine Fire Pump Controllers Features

ph COOLING TOWER CONTROLLER

Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector

Versatility 96 % ::::::::::::::::::::::::::::::::::::::: the best. mod/con Performance. and UP TO. DOE AFUE Efficiency.

eed quality electronic design USER s MANUAL

WATCHMAN Model LBW-WATCHMAN Ammonia Leak Detector

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

C1210ES Tankless Water Heater

ECHOLINE LOW PRESSURE MONITOR. Prevents Unwanted Shutdown Time and Space Saving UL Recognized

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

PAC-2750 ELECTRIC COOLING FAN CONTROLLER

Series: MBC1-TC Mini Benchtop Temperature Controller

FINNED WATER-TUBE POOL HEATERS

Owner s Manual Use with most Heat Pump systems: 1-Heat, 1-Cool 2-Heat, 1-Cool

FIREYE FLAME SCANNERS

Stratomaster Smart Single

DIVISION FINNED WATER-TUBE WATER HEATERS

MYRIAD TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL

[Thermo Simple 2 (TS.2)] Thermo Simple 2 Manual. Refrigeration Innovation

Booster Power Supply Manual

RK-05 Combustible Gas Transmitter Operator s Manual

TMC Temperature Monitoring Control Temperature Range -30 to 250 F (-35 to 120 C)

INSTALLATION INSTRUCTIONS

MBCE-110/230UV Flame Sensor Module

Operation Manual. Rev. E GEM-II Self Contained Gas Detector.

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

Pre-March 2016 Design - Click to be redirected to newer SBS-H2 design SBS-H2. Hydrogen Gas Detector Kit

Model 4001 Series Single Channel Controller

Sentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12

FPX103C. Dual Loop Auto/Manual Fire Control Panel. Technical Manual

Up to 94.6% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL CONDENSING BOILERS OPERATING CONTROL FEATURING A BUILT-IN CASCADING SEQUENCER

Model 8780 INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS. Tempering Skid General Area Classification & Class I Division 2. No.

Hubbell NX500 High Efficiency Gas Condensing Water Heater

Model 60200FR Gas Primary Control Data Sheet

FRUIT RIPENING CONTROLLER USER MANUAL SZ-FR INDIA

OPERATING INSTRUCTIONS

Instruction Manual PCS-400-XY. Pump Controller. Y=2: 4-20 ma Y=6: 0-10 VDC X=5: 1-5 VDC. 4 Pump Control Relays 1 Alarm Relay 1 Signal Fail

MODEL SF-10 CONTROL OPERATION AND INSTRUCTION MANUAL

1025, BOUL. MARCEL-LAURIN INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER. Prepared par Claude Gadoury, P. Eng MTL TECHNOLOGIES INC.

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

Control Application. Supplement - ACVMax

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

AS570 Chill-Out Combination Sensor Installation and Operating Instructions

GG-LEL2 COMBUSTIBLE GAS SENSOR. Installation and Operation Manual

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL FOR

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

USER S INFORMATION MANUAL

INSTALLATION INSTRUCTIONS TEC40 ELECTRONIC CONTROLLER

IFT-RC150 IntelliFire Touch Remote Control Installation Instructions

BGH Series Hot Surface Ignition Control

R E N HI ITI CUSTOM AN LO +12v ADJUSTMENT

INSTALLATION & OPERATION MANUAL

LABORATORY ILLUMINATED FLOTATION BATH

Operation Manual. Rev. D GEM-II Self-Contained Gas Detector.

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

OWNER'S MANUAL T0140. Contents Page #

Transcription:

TC 200 Pilotless Burner Control System INSTALLATION MANUAL FOR TC 200 Pilotless Burner Control System WARNING This manual must be read in its entirety before installation of this system. Installation must be performed by a qualified technician and must adhere to the standards set by the local regulatory authorities. is not responsible for the misuse or incorrect application of this product. 805 Main Ave. West - Box 2002 Sundre, Alberta T0M X0 - Phone: (877) 638-5234 - Fax: (403) 638-4973 - Email: aclmfg@telus.net Website: www.aclmfg.com

TC 200 Pilotless Burner Control System 64

TC 200 Pilotless Burner Control System FEATURES No Programming 2VDC or Solar Low power consumption On/Off burner control Two adjustable type K thermocouple inputs for monitoring two separate temperature points (bath temp. & high temp.) Shutdown input (ie. Low level shutdown) TYPE 4X enclosure and 3 membrane push buttons for trouble free operation Dip switch selectable thermocouple ranges of -60 C to 00 C or. 0 C to 500 C (-75 F to 202 F or 32 F to 932 F) Easy to read four digit seven segment LED display LED indication of thermocouple or 2 values displayed Dip switch selectable read out in Celsius or Fahrenheit Dip switch adjustable dead band from 2, 3, 5 and 0 degrees C (4, 6, 0 and 20 degrees F) Relay outputs rated at 5 amps and 250 VAC or 30 VDC Two 4-20 ma loop powered isolated transmitter outputs CSA certified for Class I Div 2 hazardous locations Operational ambient temperature of -40 to +60 Celsius

TC 200 Pilotless Burner Control System DESCRIPTION The TC 200 PBCS provides burner ignition and flame fail as well as monitoring of two separate thermocouple locations which can be utilized for temperature control and high temp shutdowns in process applications such as tanks, line heaters, re-boilers or any other application where accurate temperature monitoring or control is required without using a continuous pilot. The independent two temperature set points can be adjusted with the three membrane push buttons with LED indication, on the face of the controller. Initial set up can be obtained through dip switch selections for various user preferences. OPERATION Supply 2VDC to Controller as per drawing on pages 6 & 8. Display will turn on and indicate either Temp or Temp 2 which ever was selected by ½ push button. The arrows up and down select the temperature set point. Once selected, the ignition controller can be turned to the On position. This will initiate ignition if controller is calling for heat. If process is above temperature it will not initiate lighting of the burner but will turn on once process drops below set point. POWER CONNECTION The TC 200 Pilotless Burner Control System is available in 2VDC only and can be used with solar packages as well. Incorrect polarity may result in damage to circuit board components. The terminal marked ground is for power supply or system ground. THERMO- COUPLE CONNECTION The Type K thermocouple(s) are connected to their respective terminals inside the control box labeled T/C (+ & -) and T/C2 (+ & -). The customer may supply their own type K thermocouple (ungrounded) or use the manufacturers recommended assembly. 4-20 ma CONNECTION The 4-20 ma output connections are connected to their respective terminals inside the control box labeled 4-20mA (+ & -) and 4-20mA 2 (+ & -). Each output supplies a separate 4-20mA isolated signal transmitted output (Loop Powered). 2 46

TC 200 Pilotless Burner Control System INSTALLATION ADJUSTING SET POINTS 2 Selects temperature input or 2 on display Displays and increases temperature set point Displays and decreases temperature set point If left with no buttons pushed the display will revert back to show the actual thermocouple temperature reading according to the LED indication. Display will show (----) when T/C is not enabled through the designated dip switch setting or (OPEN) if T/C is not connected or if its damaged. SPECIFICATIONS CHART Voltage Current Power Frequency Relay Contact Operating Temp. Accuracy 2 VDC 0.25A.5 W XXXXXX 5 amp Per Output -40 C to 60 C +/- C (+/- 2 F) 3

TC 200 Pilotless Burner Control System Dip Switch Option Chart Board LEDs On SW8 Off High Minus 60 to 00 degrees C T/C #2 Range High SW7 Low Minus 76 to 202 degrees F T/C #2 Enable T/C # Range On High SW6 SW5 Off Low Low 0 to 500 degrees C Minus 32 to 932 degrees F T/C # Enable On SW4 Off Deadband Adjustment Deadband Deadband Display Units (see chart) (see chart) On On Deg C SW3 SW2 SW Off Off Deg F SW3 off off on on SW2 off on off on Deg C 2 3 5 0 Deg F 4 6 0 20 Switch #8 Selects board LEDs on or off Display will not show anything for this switch setting change Switch #7 Selects range for thermocouple #2 Display will show - R2 H or R2 L Switch #6 Selects thermocouple #2 enable Display will show - 2 ON or 2 OFF Switch #4 Selects thermocouple # enable Display will show - ON or OFF Switch #3 and #2 Selects deadband Display will show 2 C, 3 C, 5 C, 0 C or 4 F, 5 F, 0 F, 20 F Switch # Selects Celsius or Fahrenheit Display will show - U C or U F Switch #5 Selects range for thermocouple # 4 46

TC 200 Pilotless Burner Control System 4-20 MA OUTPUT SPECIFICATIONS High Range (-60 to 00 degrees Celsius) or (-76 to 202 degrees Fahrenheit) Thermocouple disabled Thermocouple fault (i.e. Open) Temperature equal to -60 C Temperature equal to 00 C Output = 3.5 ma Output = 22 ma Output = 4.0 ma Output = 20 ma Temperature between the limits is directly proportional to the output signal Low Range (0 to 500 degrees Celsius) or (0 to 932 degrees Fahrenheit) Thermocouple disabled Output = 3.5 ma Thermocouple fault (i.e. Open) Temperature equal to 0 C Temperature equal to 500 C Output = 22 ma Output = 4.0 ma Output = 20 ma Temperature between the limits is directly proportional to the output signal (Optional) Output for 4-20mA () Deadband set at 0 Celsius Thermocouple disabled Thermocouple opened Below setpoint 95 C Set point 00 C Above setpoint 05 C Output = 3.5 ma Output = 22 ma Output = 20 ma Output = 2 ma Output = 4 ma Temperature between the limits is directly proportional to the output signal 5

TC 200 Pilotless Burner Control System SINGLE STAGE BURNER BathTemp. HighTemp. TypeKThermocouple TypeKThermocouple Yellow Red Yellow Red TC200 Temperature Controller + + - - TC- TC-2 TypeK Thermocouple inputs + ma + 4-20mAoutput () + - - Shutdown LowLevel or Pressure (Jumper whennot used) ma + - - 4-20mAoutput (2) Relay Relay 2 (TC-) (TC-2) See note: 2 Selector Switch ON/OFF +2VDC - 2VDC + - Burner Housing Combustion Safety Control Ignition Module (optional) SSV2 SSV SD See note: P See Vnote: 2 G HighVoltage IgnitionWire ToIgnitor/Flame RodonBurner Notes: Note : SD - Solenoid Driver - reduces wattage on all solenoid valves (ideal for solar applications) Note 2: Valve output rated at Amp max 2VDC 6 46

DESIGN TEMP WITH EXCEPTION FOR REGULATOR POWER FUEL GAS PRESSURE MAX NET BTU/HR RATING ELECTRICAL AREA CLASSIFICATION NOTES: COMPANY: LOCATION/JOB #: DESIGN BASIS o o -40 C TO 65 C o o -29 C TO 65 C 2 VDC (OPTIONAL SOLAR) 4.9 PSIG 400,000BTU/HR NET CLASS I DIV 2 ITEM QTY. 2 BILL OF MATERIALS MANUFACTURING INC. 805 Main Ave West Box 2002 Sundre, AB CANADA Ph (877) 638-5234 Fax (403) 638-5234 DESCRIPTION TC 2OO - TEMPERATURE CONTROLLER CSA CLASS I DIV 2 TC-200 TSHH- TC- TC-200 CSC- SSV-/SSV-2 BA- PRV- LLSD- V JB- I 35 SERIES - COMBUSTION SAFETY CONTROLLER CSA APPROVED SAFETY SHUTDOWN VALVE. CSA CLASS I DIV -HE-ON BURNER ASSEMBLY - COMPLETE WITH IGNITOR/FLAME ROD FISHER 64-35 REGULATOR OR EQUIVALENT - 0-30 PSIG LEVEL SHUTDOWN - FIELD SELECTABLE MUST BE RATED FOR AREA CLASSIFICATION CERTIFIED BALL VALVE - CSA 3.6 OR EQUIVALENT CSA APPROVED JUNCTION BOX PSSH PRESSURE SWITCH - FIELD SELECTABLE MUST BE FOR AREA CLASSIFICATION ENGINEERING STAMP TC 200 Pilotless Burner Control System DESIGN COMPLIANCE.0 ALL APPLICABLE STATE AND PROVINCIAL CODES, STANDARDS, AND REGULATIONS MUST BE COMPLIED WITH. VARIANCES AND SPECIAL INSPECTIONS MAY BE ACCEPTABLE. 2.0 THE FUEL GAS TRAIN MUST BE FABRICATED AS DETAILED ON THE DRAWINGS. FIELD SELECTION OF SUITABLE LEVEL SWITCHES AND PRESSURE SWITCH IS ACCEPTABLE. FUEL GAS CONTROLS AND INSTRUMENTS MUST BE INSTALLED IN LOCATIONS INDICATED BY THE SCHEMATICS BELOW. NO ALTERNATE CONTROL SCHEMES OR LAYOUTS ARE ALLOWED. 3.0 THE APPLIANCE MUST BE EQUIPPED WITH A PROPER FLAME ARRESTOR. 4.0 PIPING DESIGN MUST CONFORM TO CURRENT ASME/ANSI SPECIFICATIONS. SINGLE STAGE BURNER CSA APPROVED CLASS DIV TYPE K THERMOCOUPLE ELEMENTS FOR HIGH TEMPERATURE SHUTDOWN & TEMPERATURE CONTROL NOTE: CAN BE SINGLE TYPE K OR A DUAL TYPE K UNGROUNDED 0-30PSIG PI (Optional) (Optional) JB SSV SSV 2 V BA PILOTLESS BURNER CONTROL SINGLE STAGE BURNER VENTTOSAFEAREA PRV FUELGAS 4.9PSI MAX PSHH 2VDC TC POWER 200 TC JB TSHH TC LLSD CSC HEATING APPLIANCE OR TANK 7 46

TC 200 Pilotless Burner Control System 2 STAGE BURNER (LOW FIRE HIGH FIRE) BathTemp. HighTemp. TypeKThermocouple TypeKThermocouple Yellow Red Yellow Red TC200 Temperature Controller + + - - TC- TC-2 TypeK Thermocouple inputs + ma + 4-20mAoutput () + - - Shutdown LowLevel or Pressure (Jumper whennot used) ma + - - 4-20mAoutput (2) Relay Relay 2 (TC-) (TC-2) See note: 2 Selector Switch ON/OFF +2VDC - 2VDC + - Burner Housing (optional) SSV3 SSV2 SSV See note: TSD SD Combustion Safety Control Ignition Module P See Vnote: 2 G HighVoltage IgnitionWire ToIgnitor/Flame RodonBurner Notes: Note : SD - Solenoid Driver reduces wattage on all solenoid valves (ideal for solar applications) TSD - Solenoid Driver with 0 sec time delay on Note 2: Valve output rated at Amp max 2VDC 8

DESIGN TEMP WITH EXCEPTION FOR REGULATOR POWER FUEL GAS PRESSURE MAX NET BTU/HR RATING ELECTRICAL AREA CLASSIFICATION NOTES: COMPANY: LOCATION/JOB #: DESIGN BASIS o o -40 C TO 65 C o o -29 C TO 65 C 2 VDC (OPTIONAL SOLAR) 4.9 PSIG,000,000BTU/HR NET CLASS I DIV 2 PILOTLESS BURNER CONTROL TWO STAGE BURNER (LOW FIRE, HIGH FIRE) TC-200 TSHH- TC- CSC- ITEM SSV-/SSV-2 BA- PRV- LLSD- V V2 QTY. 2 BILL OF MATERIALS MANUFACTURING INC. 805 Main Ave West Box 2002 Sundre, AB CANADA Ph (877) 638-5234 Fax (403) 638-5234 DESCRIPTION TC 2OO - TEMPERATURE CONTROLLER CSA CLASS I DIV 2 I 35 SERIES - COMBUSTION SAFETY CONTROLLER CSA APPROVED SAFETY SHUTDOWN VALVE. CSA CLASS I DIV -HE-ON BURNER ASSEMBLY - COMPLETE WITH IGNITOR/FLAME ROD FISHER 64-35 REGULATOR OR EQUIVALENT - 0-30 PSIG LEVEL SHUTDOWN - FIELD SELECTABLE MUST BE RATED FOR AREA CLASSIFCATION CERTIFIED BALL VALVE - CSA 3.6 OR EQUIVALENT /4 NEEDLE VALVE JB- CSA APPROVED JUNCTION BOX ENGINEERING STAMP TC 200 Pilotless Burner Control System DESIGN COMPLIANCE.0 ALL APPLICABLE STATE AND PROVINCIAL CODES, STANDARDS, AND REGULATIONS MUST BE COMPLIED WITH. VARIANCES AND SPECIAL INSPECTIONS MAY BE ACCEPTABLE. 2.0 THE FUEL GAS TRAIN MUST BE FABRICATED AS DETAILED ON THE DRAWINGS. FIELD SELECTION OF SUITABLE LEVEL SWITCHES AND PRESSURE SWITCH IS ACCEPTABLE. FUEL GAS CONTROLS AND INSTRUMENTS MUST BE INSTALLED IN LOCATIONS INDICATED BY THE SCHEMATICS BELOW. NO ALTERNATE CONTROL SCHEMES OR LAYOUTS ARE ALLOWED. 3.0 THE APPLIANCE MUST BE EQUIPPED WITH A PROPER FLAME ARRESTOR. 4.0 PIPING DESIGN MUST CONFORM TO CURRENT ASME/ANSI SPECIFICATIONS. 2 STAGE BURNER (LOW FIRE HIGH FIRE) CSA APPROVED CLASS DIV TYPE K THERMOCOUPLE ELEMENTS FOR HIGH TEMPERATURE SHUTDOWN & TEMPERATURE CONTROL NOTE: CAN BE SINGLE TYPE K OR A DUAL TYPE K UNGROUNDED VENTTOSAFEAREA PRV FUELGAS 4.9PSI MAX 620 0-30PSIG PI SSV SSV 2 6.5 6.5 V2 2VDC TC POWER 200 TC JB V BA TSHH TC LLSD CSC HEATING APPLIANCE OR TANK 9 46

Website: www.aclmfg.com Limited Warranty Seller warrants that the product hereby purchased is, upon delivery, free from defects in material and workmanship and that any product which is found to be defective in such workmanship or material will be repaired or replaced by Seller for a period of one year from purchase date. Warranty of such items do not include shipping, installation or set-up. Liability Statement Shall not be liable for any special, indirect, consequential or other damages of a like general nature, including, without limitation, loss of profits or production, or loss of expenses of any nature incurred by the buyer or any third party. 805 Main Ave West - Box 2002 Sundre, Alberta T0M X0 Phone: (877) 638-5234 - Fax: (403) 638-4973 E-mail: aclmfg@telus.net