GE Healthcare Healthcare Systems 9900 Innovation Drive Wauwatosa, WI USA

Similar documents
Transport Pro Patient Monitor Operator s Manual Software Version 2.1

Passport 12m and Passport 17m BEDSIDE MONITOR GUIDELINE 5.21 Software Version NAME: HOSPITAL: DATE: VALIDATOR: Performed

BeneVision Central Monitoring System. Quick Reference Guide

GE Healthcare. Quick Guide. Dash 2500 Patient Monitor

T1 BEDSIDE MONITOR GUIDELINE

Ultraview SL2400 With Wireless-LAN-Option

General Skills. yes. Device controls, buttons, indicators, and connectors

DS9400 Series. Release Notes for Firmware V2.07. Fire Alarm Control Panel

Ultraview SL Command Module Parameter Set ECG NIBP TEMP IP CO SpO2 Options SL Command Module: A B Our goals are simple:

GE Healthcare. Dash Variable-Acuity Monitoring

ENSEMBLE Central Nurse Station USER MANUAL

MRI Monitor. All-in-one monitor for the MRI environment. Features. Parameters. Accessories

VS2000V Veterinary Vital Signs Monitor Operation Manual

Clinical Information Center Pro v5 (CIC Pro)

BeneVision TM80 Telemetry Monitor

B40/B20 Patient Monitor User's Guide. English E (Paper) 21 November General Electric Company. All rights reserved.

PATIENT MONITORING SYSTEMS

Nellcor Bedside SpO 2 Patient Monitoring System, PM100N

HeartStart XL+ Configuration Worksheet

B40 Patient Monitor. Affordable clinical excellence. Advanced clinical parameters. Ease of use for fast decision-making. Performance and reliability

Avigilon Control Center 5 System Integration Guide

Quick Reference Guide STAN S31 fetal heart monitor. Power ON/OFF. ST Analysis (Fetal ECG analysis)

qube mini Overview

Avigilon Control Center 5 System Integration Guide

Alarm Management. Objectives

OPERATOR S MANUAL. NPB-4000/4000C Patient Monitor

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH

DPC-1 Programmable digital thermostat with communication Versión 2.0. Technical Information. Ref: N

Sensor Control Panel

Bosch TCU Integration Module Administrator's Guide

KELTRON LS 7000 ALARM MANAGEMENT SYSTEM Keltron Alarm Monitoring, Dispatch, and Reporting Software

ALARM SYSTEM USER S MANUAL Rev

Monitoring Operator Guide. Access Control Manager Software Version

Protégé Eclipse LED Keypad User Manual PRT-KLES

TV2 Room Pressure Monitor Quick Start Guide

2200 and 2200L ALARM CONTROL SYSTEMS

Veterinary Portable Multi-parameter Patient Monitor. Operation Manual

Quick start guide. English

Propaq LT Outline Train the Trainer

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

918TS Manual 1/26/09-1 -

AGRI-ALERT 9600 ALARM SYSTEM USER MANUAL

Avigilon System Integration Guide. Avigilon Control Center with AMAG Symmetry Security Management System 7.0

Ensuring the Effectiveness of Clinical Alarm Systems

URGENT - Field Safety Notice Medical Device Correction

DPM4 Bedside Monitor Default Settings

and Mobile Acuity LT Central Monitoring Systems

Atlas Monitor Outline Train the Trainer

DPM Summary of Features and Benefits

June 17, Skanray Technologies Pvt Ltd. c/o Ms. Yolanda Smith Regulatory Consultant Smith Associates 1468 Harwell Avenue Crofton, Maryland 21114

Managing Clinical Alarms

User Manual. Dryer Controller M720

OPERATOR S MANUAL. Patient Monitor M20. EU representative TECNOMED 2000 S.L. Valencia, Madrid Spain

Ademco Vista Alarm Panel

Entero Voice Alarm system.

Cl inician Training Packet

T1 Monitor/Module Default Settings

Product Specifications

Alarm Management at Boston Medical Center A Roadmap to Safe Silence

Alarm Fatigue in the ICU. Lynn Maguire MS, RN, PMC, NE-BC

Elderly Care Alarm System

Follett Performance Plus

1 Appendix - Product Specifications

Sensor Cloud User Manual

Dryer Controller M720

Manual# User s Manual. 200 Series. DCU 210/208 Diesel Engine Control Unit RP 210 Remote Panel

CODE ALERT Enterprise Software User Guide

OnGuard 7.2 Resolved Issues

Touchpad Exit Controller Administration Guide

NIPPY junior+ Quick Reference Guide

INSTRUCTIONS FOR USE. IntelliVue X2. Multi-Measurement Module Release G.0 with Software Revision G.0x.xx. Patient Monitoring

Code Alert Series 30 Software User Guide

SOFTWARE VERSION 8.5 FAQs

Roth Touchline. German quality since Quick and easy user manual 1/10

Version 1.03 January-2002 USER S MANUAL

Omni (K) PATIENT MONITOR

Simplex Panel Interface Guide

Alaris Syringe Module v9

USER'S MANUAL PU SENS 01 (A11) PU SENS 01 (A19) Sensor Control Panel

OPERATION MANUAL. Daikin Altherma indoor unit EKHVMRD50ABV1 EKHVMRD80ABV1 EKHVMYD50ABV1 EKHVMYD80ABV1

Vital Signs Monitor 300 Series

Entero Voice Alarm system. User guide

RPM1600 Series Room Pressure Monitors

740 SELECT. Multi-Parameter Monitor

Multiparameter. er Monitor DM

Electronic Pellet Burner Controller NPBC-V3-1

ProCon Boiler Controller Commissioning Quick Reference Guide

80BPM 36.5 C 35/ / 80. Panorama CENTRAL MONITORING SYSTEM. efficient flexible versatile (18) (94) Adult A SMITH, ERICA (92) 5RPM.

Temperature Monitoring, Operation and Maintenance of Research Freezers and Refrigerators SOP-TMOMRFR-01

Clinical Alarm Management Strategies Meaningful Alerts

Vital Signs Monitor 300 Series

OMNI TOUCH SCREEN PATIENT MONITOR

Configuration Settings Appendix

2000 SERIES DIAGNOSTIC ALARM CONTROL SYSTEM

Fire Operator Workstation (Fire OWS) User s Guide

Manufacturer s Responsibility Only under the following circumstances will manufacturer be responsible for the safety, reliability and performance of t

Spa Touch Control Panel with BP2100, BP6013 spa controllers. (Spa Owner s Manual insert)

CAN bus-based I/O module, CIO relays Mounting Terminals and wiring Commissioning, using the utility software

Dashboard for Windows V1.1.0

QAM.L L550 series. Patient Monitor Manual QAM.L

Transcription:

URGENT Field Safety Notice GE Healthcare Healthcare Systems 9900 Innovation Drive Wauwatosa, WI 53226 USA 22 nd January 2014 GEHC Ref 36092 To: Healthcare Administrator / Risk Manager Chief of Nursing Director of Biomedical Engineering RE: CARESCAPE TM Monitor B850 and CARESCAPE TM Monitor B650 issues GE Healthcare has recently become aware of potential safety issues associated with the CARESCAPE Monitor B850 and CARESCAPE Monitor B650. Please ensure that all potential users in your facility are made aware of this safety notification and the recommended actions. The following text refers to the CARESCAPE TM Monitor B850 or CARESCAPE TM Monitor B650 as Monitor CARESCAPE TM Patient Data Module (PDM) TRAM measurement Module and Patient Side Module (PSM) as Module Safety Issues and Instructions NIBP (Non-Invasive Blood Pressure) Issues: 1. NIBP auto-cycling will not start. NIBP auto-cycling does not always start as expected. The problem may occur with the Patient Data Module (PDM) which is connected to monitor with active patient case, and module time is not in sync with the monitor time. Re-start NIBP auto-cycling 2. NIBP auto-cycling stops when selecting Audio & Display Off. When entering Sleep Mode (Audio & Display Off), the monitor stops NIBP auto-cycling. Therefore, the NIBP data and possibly related alarms are not seen remotely (Bed-to-bed monitoring, central stations). Do not use the Audio & Display Off function when NIBP is auto-cycling. 3. NIBP auto-cycling stops when loading data and measuring NIBP at the same time. If the NIBP auto-cycle measurement is started at the same time when data is loading from the Patient Data Module (PDM) to the monitor, NIBP measurement is interrupted and the auto-cycling stops. When connecting the PDM to the monitor, wait for the NIBP measurement to finish before you initiate the Load PDM Data action. 4. Lost NIBP measurements. If a network time update happens exactly at the same minute or just before a NIBP auto cycle measurement would be started, the measurement is not performed and a previously taken NIBP measurement Page 1 of 6

disappears from the monitor display. Do a manual NIBP measurement in case auto-cycle measurement is missed. 5. NIBP limit values for infants change when loading new patient data from a TRAM module. When monitor has an already ongoing patient case, which has different demographics (patient name or Medical Record Number) than in the TRAM module that is connected to the monitor and "Load Tram Data" is selected, NIBP infant limits are set to 80/140 instead Infant default values of 50/120. Make sure that the previous patient is manually discharged before connecting a TRAM module with a new patient s data to the monitor. In this case, the Load TRAM data selection can be safely used. If the same patient is admitted to both monitor and the TRAM module, use the Combine Data option when connecting the TRAM to the monitor. ECG Issues: 6. Wrong ECG bandwidth in E-PSM(P) or E-(P)RE(S)TN module. Occasionally, when the monitor is turned on, the E-PSM(P) or E-(P)RE(S)TN module starts using monitor filter instead of diagnostic filter. This will cause changes in ECG waveform morphology, which may lead to erroneous ST readings on monitor display. Reconnect the module while the monitor is running. 7. Changing the primary ECG lead selection in the CIC Pro Central Station will not change the primary measurement lead in PDM or Tram measurement modules. This may lead to missed arrhythmias or unreliable HR calculation with low amplitude ECG waveforms. When using a 3-lead ECG cable with PDM or Tram modules, adjust the primary lead selections from the monitor, not the CIC Pro Central Station. When using an ECG cable with 5 or more leads with PDM or Tram modules, enable the Multi Lead analysis located in Parameter Setup ECG Lead Analysis. Central Monitor Issues: 8. A temporarily hidden alarm message will not re-activate if a different alarm is acknowledged at icentral. When an alarm is acknowledged at icentral, all consecutive alarms will be muted until any alarm audio control button is touched. This may possibly lead to missed alarms. Press the Activate all audible alarms button 9. Missing audible alarms from remote monitors after broken network connection. If user acknowledges Monitor disconnect alarm after a lost network connection, and then the monitor is reconnected, new alarms from the remote location cannot be heard if they appear while the pause period is active. Note that the visual indication shows on display as expected. Also all alarms, both audible and Page 2 of 6

visual, work as expected at the bedside. Acknowledge the Monitor disconnect alarm without starting a pause period (e.g. press Audio pause button three times). Pay extra attention to the patient and the visual bed-to-bed alarm indications for a period of five minutes after a network reconnection. If you see this issue, re-start the monitor to ensure smooth operation 10. Missing ECG waveforms on icentral. ECG waveforms do not show on icentral when 6 lead ECG lead set is used without the 12RL option. Despite the missing waveform, the Heart Rate and ST readings and all related alarms work as expected. Use 3, 5 or 10 lead ECG lead set when viewing monitor on icentral. Ensure 12RL license option is activated on the monitor when 6 lead ECG cable is used and monitor is viewed from icentral. 11. icentral does not notice a monitor exiting the Standby Mode. Standby does not end at icentral when power button pressed during standby at B650. Do not power off the monitor during standby. If the monitor has been powered off during standby, reboot the monitor. 12. Erroneous labeling of ECG leads with the PSM and PDM modules, a 6-lead ECG cable and CIC. When V lead A is remotely changed from the CIC to the same value as V lead B, the V lead A is not correctly updated to the CIC anymore. Instead, the V lead B s measurement values will be shown under A s label. Workaround instructions before the software correction Do not change V lead A remotely to use the same selection as V lead B Use 5 or 10 lead ECG cables Ventilation Alarms Issues: 13. Incorrect display resolution for the Airway Pressure (Paw) values in kpa Bed to Bed view. Paw values in kpa in Bed to Bed view are shown as integer instead of one decimal resolution as they should when unit is kpa. Values are shown correctly at the bedside monitor and also correctly in bed to bed view with all other PAW units. Also, alarms work correctly. Choose a unit other than kpa, for example hpa, cmh2o, mmhg or mbar 14. Fixed spirometry Alarm Limits. If UnityID interfacing device has been configured as the spirometry measurement source before Gas Module is connected to the monitor, which is then restarted, the spirometry Alarm Limits cannot be changed. This problem only occurs with CARESCAPE Monitor B650. General Issues: Reconnect the Gas Module into the monitor Page 3 of 6

15. Lost ALARM OFF icon. When an alarm is turned OFF, then back ON and then OFF again, the ALARM OFF icon is not displayed in the small Parameter Window anymore. Configure the monitor display so that all displayed parameters use any of the other three Parameter Window shapes instead of Small, i.e. Wide, Tall or Big. 16. Previous Patient s Data on Monitor after Auto Discharge. The Auto Discharge function erases patient data from the monitor but not from other acquisition units, such as PDM. Therefore, the user may encounter previous patient s data, such as name and patient ID on the monitor. Pay attention to the patient data after an auto discharge and when starting a new case. If there are any data left from the previous patient, manually discharge the patient. This will reset all data in both the monitor and the acquisition device. 17. At Invasive Pressure parameter the site information is only handled after the full configuration has been received from the Patient Data Module (PDM) at connection to ensure the zeroing information has also been received. At the receiving end of the configuration the earlier received labels would be applied but there was an error causing the previous ones to be first sent back to the module. Should this occur, the labels may be changed back to the monitor labels after a communication delay with the module. Check that the labels are correct after connecting the PDM. 18. In the Patient Data Module stack, the site change messages received after the device has been disconnected would still be processed and left pending waiting for the next incoming message. As the PDM would be connected, the pending labels would be immediately sent to the PDM which would mirror them back to the monitor. If the pending label differs from the labels to be loaded from the PDM this may result in incorrect labels. Check that the labels are correct after connecting the PDM. Tram Issues: 19. Missing Service Alarm with the Tram Module. When a Tram Module initiates a Service Alarm reading Service Monitor Possible Data Corruption, this Service Alarm is not displayed remotely at CIC s bed to bed view. When there is a reason to doubt the Tram-initiated patient data viewed remotely, check the local monitor for any technical alarms(s). Bed to Bed Issues: 20. Bed to Bed view does not always show the highest ST value in S/5 network. The ST value that is shown in Bed to Bed view of the icentral central station should be the highest value of all leads. Currently, the ST values of leads V2, V3, V4, and V6 are left out of the calculation, so the highest ST value may not be visible on Page 4 of 6

icentral s Bed to Bed view. This issue does not affect ST alarms, which work as expected. Do not base clinical decisions on the bed to bed view ST values before re-checking them on the local monitor 21. Missing remote bed alarm when manual bed to bed view is opened at the time of alarm. When manual bed to bed view to remote monitor 2 is opened at the same time as the local monitor 1, than an alarm activates at remote monitor 3, that alarm is not activated at the local monitor 1 screen. Alarm of the remote monitor 3 can be seen in other remote monitor screens and central stations. All the alarms after the menu opening are working properly on local monitor 1 screen and only the alarm at the time of the menu opening is missed. Pay special attention to the local monitor alarms if manual bed to bed view is used. 22. AVOA alarm from remote bed missing. If manual bed to bed view to monitor 3 is opened at the local monitor1, without closing the bed to bed view to monitor 2 according to instructions in the user manual, monitor 2 alarms are not any longer activating at the local monitor 1 screen automatically but only if manual bed to bed view is opened. Monitor 2 alarms are working properly at the bedside and other remote monitors and central stations. Follow the instruction of the user manual and close the view of the remote monitor before opening the view to another remote monitor. 23. When All monitors disconnected alarm is deactivated due to receiving monitor returning to the network, individual Monitor disconnected alarms are not restored for remote monitors that are offline at that time. Check the monitor online status from Other patients menu Change the subscription and reboot the monitor if needed 24. In CARESCAPE Monitor B650 Monitor disconnected low priority message remains in the Message Field of the monitor even when the monitor is connected back to network. If an alarm occurs at the remote bed the Monitor disconnected message is cleared and Auto View or Message Field is displayed according to the subscription (Auto View / Auto View Always or Message). Check the monitor online status from Other patients menu Change the subscription and reboot the monitor if needed 25. If the Monitor disconnected is from CARESCAPE Monitor B650 deactivated manually, and the remote monitor is disconnected from the network again, the Monitor disconnected message does not get activated. In another use case for the same indicator, if the user visits the Other patients menu when a remote monitor with AVOA subscription is disconnected from the network but before the Monitor disconnected alarm has been detected at the local monitor, the Monitor disconnected alarm may not be activated at all. The time window when Page 5 of 6

the issue can occur is that the user visits the Other patients menu after 20-60 seconds from the moment when the remote monitor was disconnected from network. This occurs only in Unity network. Check the monitor online status from Other patients menu Change the subscription and reboot the monitor if needed Affected Product Details Product Correction Contact Information The issues described above may occur in CARESCAPE TM Monitor B850 with software versions 1.0.12 and earlier and in CARESCAPE TM Monitor B650 with software version 1.1.12 and earlier. Please retain a copy of these instructions with the user manual for your CARESCAPE TM Monitor B850 or CARESCAPE TM Monitor B650. GE Healthcare will provide a correction at no charge once it is available. We will contact you to arrange for this correction. If you have any questions regarding this notification, please contact Technical Support or your local Service Representative. Oxygen Care Ltd. 2 Holfeld Business Park, Kilmacanogue, Co. Wicklow, Ireland. Phone: ++353 1 276 9700 e-mail: a.healy@oxygen-care.ie Please be assured that maintaining a high level of safety and quality is our highest priority. If you have any questions, please contact us immediately per the contact information above. Sincerely, James Dennison Vice President QARA GE Healthcare Systems Douglas M. Hansell, M.D., MPH Chief Medical Officer GE Healthcare Page 6 of 6