FTB-200. The Compact Platform Built for the Supertech COMPACT PLATFORM

Similar documents
AXS-100. Series NETWORK TESTING OPTICAL HANDHELD OTDR. Compact, rugged, lightweight OTDRs optimized for access/fttx and LAN/WAN network testing

AXS-100 Series HANDHELD OTDR. Telecom Test and Measurement

FastReporter 2 DATA POST-PROCESSING SOFTWARE

Event dead zone: 0.8 m. Attenuation dead zone: 4 m. Dynamic range: up to 50 db. Platform compatibility. FTB-200 Compact Platform

LAN/WAN OTDR FTB-7200 FTTx Access/Metro OTDR FTB-7200/7300 Metro/Long-Haul OTDR FTB-7400/74000 Long-Haul OTDR FTB-7500

FTBx-740C-DWC TUNABLE OTDR C-BAND DWDM METRO ETHERNET LINK CHARACTERIZATION

FastReporter 2 DATA POST-PROCESSING SOFTWARE

Extensive range of models covering all telecom testing applications. Flexible design, allowing up to three wavelengths in a single module

FTB/FTBx-740C-CWDM Tunable OTDR 18-WAVELENGTH CWDM OTDR FOR METRO ETHERNET AND C-RAN LINK CHARACTERIZATION

MaxTester 730B FTTx/MDU PON OTDR

FTB-7400E Metro/CWDM OTDR METRO/CORE AND CWDM NETWORK FIBER CHARACTERIZATION

FastReporter 2 DATA POST-PROCESSING SOFTWARE

FTB-730 PON FTTx/MDU OTDR OPTIMIZED FOR ACCESS FIBER DEPLOYMENTS AND TROUBLESHOOTING

FOT-930 MaxTester MULTIFUNCTION LOSS TESTER

Kingfisher KI-3800 Light Source. Inexpensive handheld source for testing and commissioning optical fibre networks. Compact and rugged,

MaxTester 730B PON/METRO OTDR

FTTH NETWORK TESTING: REAL APPLICATIONS USING THE OLTS METHOD

MaxTester 715B Last-Mile OTDR

FLX380-30x FlexTester OTDR

Intelligent Optical Link Mapper (iolm)

FTB-720 LAN/WAN Access OTDR OPTIMIZED FOR MULTIMODE AND SINGLEMODE ACCESS NETWORK TESTING

THE ENTRY-LEVEL SOLUTION DESIGNED FOR ALL YOUR TESTING NEEDS

M700-Series Multifunction OTDR

MTTplus Modular Test Platform

DWDM OTDR with Tunable Laser MTP-200-D100. Hand-held High Performance OTDR. Series

100B MINI-OTDR FTB-100B. EXFO s rugged, flexible OTDR-dedicated portable platform. Telecommunications Test and Measurement

MaxTester 715B Last-Mile OTDR

ENCIRCLED FLUX (EF) TEST SOLUTIONS SPSB-EF LAUNCH MODE CONDITIONER AND FLS-600-NS1548 LIGHT SOURCE DESIGNED FOR CONTROLLED MULTIMODE LOSS TESTING

palmotdr Series Handheld OTDR

FX150 OTDR. Platform Highlights. Key Features

FTBx-750C Metro/Long-Haul OTDR LONG-DISTANCE FIBER CHARACTERIZATION AND FIBER UPGRADES

ENCIRCLED FLUX (EF) TEST SOLUTIONS

SunLite OTDR+ Platform Highlights. Key Features. Power meter, light source, fiber inspection probe and VFL options

OTDR II. Tier-2 Optical Time Domain Reflectometer for Multimode and Single-mode Fiber Cabling

M210 Multifunction Micro OTDR


M210 Multifunction Micro OTDR

FG-750 Client API SDN-READY INTELLIGENT OTDR

palmotdr Series Handheld OTDR

Intelligent Optical Link Mapper (iolm)

FTB-735C Metro/PON FTTx/MDU OTDR

M700-Series OTDRs. or (800) , (603)

MaxTester 730C PON/METRO OTDR OPTIMIZED FOR FTTx/MDU FIBER DEPLOYMENTS AND TROUBLESHOOTING, SUITABLE FOR METRO

MaxTester 715B Last-Mile OTDR POINT-TO-POINT (P2P) LINKS, LAST-MILE INSTALLATION AND TROUBLESHOOTING

FTBx-730C PON FTTx/MDU OTDR OPTIMIZED FOR FTTx/MDU FIBER DEPLOYMENTS AND TROUBLESHOOTING

Noyes OFL 250B Specs Provided by

ACCESS Master MT9085 Series. Product Introduction

The Definitive Handheld OTDR for FTTx Testing OTDR AXS Compact, lightweight handheld OTDR optimized for access/fttx network testing

FTS500 Series. Handheld OTDR Test Set.

MaxTester 715B Last-Mile OTDR POINT-TO-POINT (P2P) LINKS, LAST-MILE INSTALLATION AND TROUBLESHOOTING

VePAL FX300 Fiber Expert OTDR

OPX-350 Series. Fiberizer Cloud. Universal Performer for Fiber Testing. Add value with. Test and Measurement in Fiber Optics

740C xwdm OTDR Series C-BAND DWDM AND 18-WAVELENGTH CWDM TUNABLE OTDR SERIES FOR METRO ETHERNET AND C-RAN LINK CHARACTERIZATION

M310 Enterprise OTDR. Designed for Enterprise Network Testing, Troubleshooting and Documentation. or (800) , (603)

AE3100A~M Series 2-and 4-Wavelength Handheld OTDR

iotdr Series Portable OTDR Test Set iotdr Series OTDR Tester is entirely new portable product released by OPWILL.

FLX380-30x FlexTester3 OTDR

FTB-720C LAN/WAN Access OTDR OPTIMIZED FOR MULTIMODE AND SINGLEMODE ACCESS NETWORK TESTING

FTS510 Series. Handheld OTDR Test Set.

Fiberizer IIT-6000 Series

AV6416 OTDR. Product Overview: Main Features:

AE2200 FTTx Multi-Function Meter

OPX-BOX. Platform Highlights. Software Support. Key Features

FHO5000 Series Triple-Proof OTDR

M310 Data Center OTDR

M210 Multifunction Micro OTDR

OTP6123 Series. Handheld OTDR Test Set.

OPX-BOXe Rugged, Pocket-sized Mini OTDR

M310 Enterprise OTDR. Designed for Enterprise Network Testing, Troubleshooting and Documentation. or (800) , (603)

T-BERD 6000 Compact Optical Test Platform

VePAL FX300 Portable OTDR, Fault Finder, Optical Power Meter, Visual Fault Locator, and Laser Source Test Set

MINI2. Inno Mini 2 Specs Provided by MOST ACCURATE COMPACT OTDR

Terahertz Technologies Inc Fiber Optic Test Equipment Catalog

High cost performance choice

VIEW500 FASTEST STANDARD OTDR

VIEW500 USER-FRIENDLY STANDARD OTDR

Fiber Guardian. Fiber Guardian. Where fiber monitoring starts. Key Features

VePAL FX300 Portable OTDR, Optical Power Meter, Visual Fault Locator, and Laser Source Test Set

High cost performance choice

MINI2 MOST ACCURATE COMPACT OTDR

Terahertz Technologies Inc.

intelligent Optical Link Mapper (iolm)

SmartClass and SmartPocket Optical Handhelds. Portfolio of Optical Handhelds for Fiber Field Test

A dvan ced Fib er Opt ic Test Eq u ip me nt Terahertz Technologies Inc.

Intelligent Optical Link Mapper (iolm)

Advanced Fiber Optic Test Equipment Terahertz Technologies Inc.

Agilent E6012A Specs Provided by E6000C Mini-OTDR. Technical Data Sheet

Acterna MTS 5000 e Series OTDR and Loss Test modules

OTDR - FHO5000-xxx. Optical Time Domain Reflectometer

Agilent E6000A E6003A Specs Provided by E6000C Mini-OTDR. Technical Data Sheet

Fibre Characterisation and FTTx New challenges

Remote fiber testing to improve SLA s

OptiFiber Pro OTDR Built for the enterprise

Refurbished EXFO Instruments

Link loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team

Network Master Series

Table of Contents 1Q08. Test & Inspection

MT9083 Series MT9083A2/B2/C2 ACCESS Master

OptiFiber Pro OTDR Built for the enterprise

CMA4000i Optical Test System

Transcription:

COMPACT PLATFORM FTB-200 NETWORK TESTING ACCESS The Built for the Supertech The FTB-200 is a compact, modular platform designed for multilayer and multimedium testing Tests physical, transport and datacom Accommodates two field-interchangeable modules Integrated hardware options such as visual fault locator (VFL), fiber inspection probe and CWDM-calibrated power meter Designed for metro/access and FTTx networks Eight CWDM wavelengths in one compact platform Lightweight construction Touchscreen resistant to shock, water, dust and common chemicals Dial and shortkeys for easy scrolling and selecting Extended battery autonomy of more than eight hours, perfect for OTDR testing Improved productivity Four-second power-up time with Windows CE Faster acquisition, processing and reporting Next-Generation Network Assessment

A compact platform Optimized for Large-Scale Network Deployments EXFO has created the first true compact platform for the supertech. Whether you are testing triple-wavelength insertion loss at the CO or testing data integrity at the core, the FTB-200 has the power, speed and modularity that you need in the field. Optimized for all phases of the network lifecycle Construction/installation System provisioning/service activation Maintenance/troubleshooting Lightweight 2.5 kg/5.4 lb (platform only) Fast and powerful Four-second power-up time with Windows CE/ mobile Faster acquisition, processing and reporting Instantaneous AutoSync USB data transfer Faster acquisitions down to five seconds Remote control and virtual applications Flexible connectivity File transfer and software upgrading through USB USB A/A-B, RJ-45 and Bluetooth flexibility Compact Flash (memory, Wi-Fi and Bluetooth) Built for the outside plant Waterproof outer shell, sealed joints, door panels for extra port protection Advanced TFT transflective display, for great visibility under direct sunlight Rugged shortkeys and tracking knob GR-196-CORE-compliant Extended battery autonomy of more than eight hours

SONet/SDh and ethernet test Modules FTB-8120NGE/8130NGE Power Blazer Next-Generation Multiservice Test Module The most compact multiservice transport network installation, commissioning and service turn-up solution DSn/PDH, SONET/SDH and OTN up to 10.7 Gbit/s 10/100/1000M, GigE and 10GigE BERT, and RFC 2544 One-touch SONET/SDH/OTN signal discovery via SmartMode feature, ideal for service monitoring and troubleshooting Battery operation, instantaneous power-up, touch screen and remote control capability Optional integrated visual fault locator (VFL), fiber inspection probe and power meter FTB-8100 Transport Blazer SONET/ SDH Test Module Series Comprehensive test functionality for DSn/PDH and SONET/SDH test applications Most compact and complete SONET/SDH and OTN (ITU-T G.709) testing Multirate configurable test solutions ranging from DS0/E0 to OC-192/STM-64 One-touch SONET/SDH signal discovery and fault isolation via Smartmode feature FTB-8510B Packet Blazer Ethernet Test Module Ethernet-based IP services testing with wire-speed full-duplex 10, 100 or 1000 Mbit/s traffic-generation capabilities Throughput, burstability (back-to-back), latency and frame loss measurements as per RFC 2544 TCP throughput measurement for assessing application data transmission over a TCP/IP connection Quality of service performance assessment via multistream generation and analysis FTB-8510G Packet Blazer 10 Gigabit Ethernet Test Module Fully integrated functionality for assessing the performance of Ethernet transport networks Throughput, burstability (back-to-back), latency and frame loss measurements as per RFC 2544 EtherBERT test functionality for assessing the integrity of 10 Gigabit Ethernet running on WDM networks Quality of service performance assessment via multistream generation and analysis Power Blazer (FTB-8120NGE) Transport Blazer (FTB-8130NGE) Packet Blazer (FTB-8510B) Packet Blazer 10 Gigabit (FTB-8510G)

OtDr, OLtS and Dispersion test Modules FTB-7000 OTDR Series EXFO s OTDR modules meet all your testing needs with numerous singlemode and multimode configurations available at several wavelengths. The FTB-7000 family includes four lines of OTDRs: the FTB-7200 LAN/WAN Access OTDR, the FTB-7300 FTTx PON/MDU OTDR, the FTB-7400 Metro/CWDM OTDR, the FTB-7500 Long- Haul OTDR and the FTB-7600E Ultra-Long-Haul OTDR. Event dead zone: 0.8 m Attenuation dead zone: 4 m Wide dynamic range: up to 50 db FTTx-ready: passive optical network (PON) and point-to-point testing capabilities 40 Gbit/s-ready: metro and long-haul network testing capabilities CWDM-ready: test through mux/demux at ITU-recommended wavelengths World-leading OTDRs (FTB-7000 series) FTB-3930 MultiTest Module (OLTS) Fully automated bidirectional loss tests in seconds for up to three wavelengths; automatic ORL and fiberlength measurements Combines eight functionalitites in a single module: Loss meter Power meter Optical return loss (ORL) meter Visual fault locator Multimode and singlemode light sources Digital talk set Fiber-length meter MultiTest module (OLTS) (FTB-3930) FTB-5700 Single-Ended Dispersion Analyzer The ultimate CD/PMD characterization solution Single-ended PMD and CD measurements The advantage of one: complete dispersion analysis with a single module, a single connector and a onestep test setup Unparalleled software user-friendliness: all automated Testing range: up to 140 km Single-Ended Dispersion Analyzer (FTB-5700)

Intuitive Interface Designed for time-saving efficiency All the OTDR Modes You Need The FTB-200 s OTDR software is both automated and easy to use. Choose from four operating modes according to your specific requirements: Auto Mode Lets you select acquisition parameters automatically. Perfect for basic, repetitive OTDR applications or for occasional users. Parameter setup simple as 1-2-3 Minimal training required No need to browse through menus and submenus Fault Finder Mode Save valuable time when you need to quickly find the end of fiber, without setting any parameters. Click the start button Click the start button Get the results Select OTDR Mode Display the fiber length Select Auto mode Advanced Mode Offers multiple setup and measurement capabilities for increased flexibility. Control all parameters on a single page and optimize your measurement setup to pinpoint specific anomalies. Template Trace Mode Compares each acquisition with a designated template trace for complete cable testing and documentation. Optional tools: Packing more functions in a single unit Power Meter Fiber Inspection Probe Offered with two detector types: - GeX for high-power measurement - InGaAs for high dynamic range Calibrated at 7 or 20 CWDM wavelengths - Data-saving capabilities Tone recognition Connector endface verification Image capture for documentation purposes Compact, lightweight 200X or 400X magnification Visual Fault Locator (VFL) Simple fiber identification Pinpoints breaks and faulty connections Bright and powerful red laser Software OPTION: SMART KIT Linear trace view Virtually eliminates the need to analyze complicated OTDR traces Straightforward display and event table Easy toggling between OTDR traces and linear view Macrobend finder Allows you to easily characterize macrobends View the data in the summary screen Automated macrobend characterization

Data post-processing The FTB-200 uses ToolBox Office software, which offers great functions: Bidirectional trace analysis* Improve the accuracy of your loss measurements with the bidirectional averaging feature, which uses OTDR acquisitions from both ends of a fiber span to average loss results for each event. *Available on singlemode OTDRs only. Efficient multifiber testing with Template Trace Reduce testing time when commissioning a large number of fibers by using the Template Trace mode. This mode dynamically compares new OTDR results with a trace you assign as a reference. Reference trace documentation is automatically pasted onto new acquisitions to save you time. Professional report generation User-configurable test reports and batch printing let you generate complete, professional OTDR reports quickly and efficiently. Fast-Track Data Post-Processing with FastReporter Software The optional FastReporter software package provides you with the post-processing tools and functionalities you need to achieve flexible, fully integrated data analysis, whatever the application. Designed for off-line analysis of field-acquired data, FastReporter offers a truly intuitive graphical user interface, which contributes to boosting productivity. Powerful Batch Processing Automate repetitive operations on large numbers of OTDR test files, and optimize your productivity. Document an entire cable in a matter of seconds. Adjust your cable parameters and detection thresholds and perform batch analysis. Open OTDR files from various vendors equipment and convert them to the universal Telcordia format. Bidirectional Batch Analysis Analyze an entire cable in just two steps. View data for all events on all fibers, and at each wavelength, on a single screen. Live Templating for OTDR Testing Benefit from one-step file management at any wavelength. Keep full control by adding or removing events manually, or add/remove events automatically using a reference. Get uniform, detailed cable reports. Bidirectionnal Batch Analysis Flexible Reporting Choose from various report templates, including loss and ORL, OTDR, PPM, PMD, CD, fiber characterization and cable report. Generate comprehensive cable reports in PDF, Excel or HTML format.

SPECIFICATIONS a Display Interfaces Storage Batteries b Power Supply Touchscreen, color, 640 x 480 TFT 163 mm (6 7 /16 in) USB A main USB B remote RJ-45 LAN 10/100 Mbit/s Compact Flash Fiber inspection probe connector port (video) Internal 80 MB (Flash) USB sticks 1 GB and 2 GB (optional) Compact Flash cards (optional) Rechargeable Li-Ion 8 h of operation as per Bellcore TR-NWT-001138 AC/DC adapter, input 100-240 VAC, 50-60 Hz, 2 A max, output: 24 VDC, 90 W GENERAL SPECIFICATIONS Temperature operating 5 C to 50 C (23 F to 122 F) storage c 40 C to 70 C ( 40 F to 158 F) Relative humidity 0 % to 95 % non-condensing Size (H x W x D) 322 mm x 197 mm x 109 mm (12 11 /16 in x 7 3 /4 in x 4 5 /16 in) Weight 2.5 kg (5.4 lb) Vibration < 1.5 g at 10 Hz to 500 Hz (on three main axes) Mechanical shock < 760 mm on six sides and eight main edges (according to GR-196-CORE) ACCESSORIES FP4S FP4D GP-10-070 GP-10-072 GP-302 GP-308 GP-2001 GP-2011 GP-2012 GP-2014 GP-2015 FP4S 400X Fiber Inspection Probe 200/400X Fiber Inspection Probe Rigid FTB-200 carrying case Semi-rigid FTB-200 carrying case USB mouse DC car adapter/inverter USB keyboard Compact Flash Ethernet WiFi card Compact Flash Bluetooth card Compact Flash memory 1 GB card Compact Flash memory 2 GB card GP-2016 GP-2017 GP-2019 GP-2021 (A-E-I-J-S-U) GP-2023 GP-2024 GP-2025 GP-2027 GP-2028 10 feet RJ-45 LAN cable Spare FTB-200 battery USB micro drive standard capacity Spare AC power supply (requires AC external adapter/charger). Specify: A North America, E Europe, I India, J Japanese, S Australia and New-Zealand, U United-Kingdom Spare neck strap Spare belt strap Spare battery door Portable printer Computer security cable kit PM-200 BuILT-IN POWER METER SPECIFICATIONS d Calibrated wavelengths (nm) 850, 1300, 1310, 1490, 1550, 1625, 1650 Optional CWDM calibrated wavelengths (nm) 1270, 1290, 1310, 1330, 1350, 1370, 1390, 1410, 1430, 1450, 1470, 1490, 1510, 1530, 1550, 1570, 1590, 1610, 1383, 1625 Power range (dbm) 10 to 86 (InGaAs) 26 to 64 (GeX) Uncertainty (%) e ±5 % ± 3 pw (InGaAs) ±5 % ± 0.4 nw (GeX) Display resolution (db) InGaAs 0.01 = max to 76 dbm 0.1 = 76 dbm to 86 dbm 1 = 86 dbm to min GeX 0.01 = max to 54 dbm 0.1 = 54 dbm to 64 dbm 1 = 64 dbm to min Automatic offset nulling range f Max power to 63 dbm for InGaAs Max power to 40 dbm for GeX Tone detection (Hz) 270/1000/2000 VISuAL FAuLT LOCATOR (VFL) (OPTIONAL) Laser, 650 nm ± 10 nm CW Typical Pout in 62.5/125 µm: 3 dbm (2 mw) Notes a. All specifications valid at 23 C (73 F). b. Standard recharge time is 3 h. Recharge temperature: 0 C to 35 C (32 F to 95 F). c. Not including internal batteries. Battery maximum storage temperature: 60 C (140 F). d. At 23 ºC ± 1 ºC, 1550 nm and FC connector. With modules in idle mode. Battery operated. e. Up to 5 dbm. f. For ±0.05 db, from 18 ºC to 28 ºC. LASER SAFETY If VFL option is available IEC 60825-1:2007 21 CFR 1040.10 LASER RADIATION AVOID DIRECT EYE EXPOSURE CLASS 3R LASER PRODUCT λ: 650 ±10 nm P out maximum < 5mW (into free space) 21 CFR 1040.10 AND IEC 60825-1:2007 CLASS 3R WITH VFL OPTION

ORDERING INFORMATION FTB-200-XX-XX-XX-XX-XX-XX Modular compact platform Display S1 = TFT active screen S2 = Outdoor enhanced screen Power meter 00 = Without power meter PM2X = Power meter only; high-power GeX detector PM3 = Power meter only; InGaAs detector VPM2X = VFL platform; power meter; high-power GeX detector VPM3 = VFL platform; power meter; InGaAs detector PM2X-CWDM = Power meter GeX detector, CWDM-calibrated wavelengths (from 1270 to 1610 nm) PM3-CWDM = Power meter InGaAs detector, CWDM-calibrated wavelengths (from 1270 to 1610 nm) Example: FTB-200-S1-VPM2X-U25-FOA-22-FP4S-SK2 Software summary kit 00 = Without software summary kit SK2 = IP testing SK6 = Macrobend detection and linear trace view Probe option 00 = Without probe FP4S = Inspection probe (400x) FP4D = Inspection probe (200x/400x) Connector adapter FOA-12 = Biconic FOA-14 = D4, D4/PC FOA-16 = SMA/906 FOA-22 = FC, FC (PC/SPC/UPC/APC, NEC-D3) FOA-28 = DIN 47256 (LSA): DIN 47256 (PC/APC) FOA-32 = ST, ST (PC/SPC/UPC) FOA-40 = Diamond HMS-0, HFS-3 (3.5 mm) FOA-54 = SC (PC/SPC/UPC/APC) FOA-76 = FSMA HMS-10/AG, HFS-10/AG FOA-78 = Radiall EC FOA-84 = Diamond HMS-10, HFS-13 FOA-96B = E2000 FOA-98 = LC FOA-99 = MU VFL connector U25 = Connector for 2.5 mm ferrules EXFO Corporate Headquarters > 400 Godin Avenue, Quebec City (Quebec) G1M 2K2 CANADA Tel.: +1 418 683-0211 Fax: +1 418 683-2170 info@exfo.com Toll-free: +1 800 663-3936 (USA and Canada) www.exfo.com EXFO America 3701 Plano Parkway, Suite 160 Plano, TX 75075 USA Tel.: +1 800 663-3936 Fax: +1 972 836-0164 EXFO Asia 151 Chin Swee Road, #03-29 Manhattan House SINGAPORE 169876 Tel.: +65 6333 8241 Fax: +65 6333 8242 EXFO China Beijing New Century Hotel Office Tower, Room 1754-1755 Beijing 100044 P. R. CHINA Tel.: +86 (10) 6849 2738 Fax: +86 (10) 6849 2662 No. 6 Southern Capital Gym Road EXFO Europe Omega Enterprise Park, Electron Way Chandlers Ford, Hampshire S053 4SE ENGLAND Tel.: +44 2380 246810 Fax: +44 2380 246801 EXFO Service Assurance 285 Mill Road Chelmsford, MA 01824 USA Tel.: +1 978 367-5600 Fax: +1 978 367-5700 EXFO is certified ISO 9001 and attests to the quality of these products. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. EXFO has made every effort to ensure that the information contained in this specification sheet is accurate. However, we accept no responsibility for any errors or omissions, and we reserve the right to modify design, characteristics and products at any time without obligation. Units of measurement in this document conform to SI standards and practices. In addition, all of EXFO s manufactured products are compliant with the European Union s WEEE directive. For more information, please visit www.exfo.com/recycle. Contact EXFO for prices and availability or to obtain the phone number of your local EXFO distributor. For the most recent version of this spec sheet, please go to the EXFO website at http://www.exfo.com/specs In case of discrepancy, the Web version takes precedence over any printed literature. 2008 SPFTB200.6AN 2009 EXFO Electro-Optical Engineering Inc. All rights reserved. Printed in Canada 09/11