ENCIRCLED FLUX (EF) TEST SOLUTIONS

Similar documents
ENCIRCLED FLUX (EF) TEST SOLUTIONS SPSB-EF LAUNCH MODE CONDITIONER AND FLS-600-NS1548 LIGHT SOURCE DESIGNED FOR CONTROLLED MULTIMODE LOSS TESTING

FTB-720 LAN/WAN Access OTDR OPTIMIZED FOR MULTIMODE AND SINGLEMODE ACCESS NETWORK TESTING

FTB-7400E Metro/CWDM OTDR METRO/CORE AND CWDM NETWORK FIBER CHARACTERIZATION

FTBx-740C-DWC TUNABLE OTDR C-BAND DWDM METRO ETHERNET LINK CHARACTERIZATION

Intelligent Optical Link Mapper (iolm)

FTB-730 PON FTTx/MDU OTDR OPTIMIZED FOR ACCESS FIBER DEPLOYMENTS AND TROUBLESHOOTING

FTB-720C LAN/WAN Access OTDR OPTIMIZED FOR MULTIMODE AND SINGLEMODE ACCESS NETWORK TESTING

LAN/WAN OTDR FTB-7200 FTTx Access/Metro OTDR FTB-7200/7300 Metro/Long-Haul OTDR FTB-7400/74000 Long-Haul OTDR FTB-7500

FTB/FTBx-740C-CWDM Tunable OTDR 18-WAVELENGTH CWDM OTDR FOR METRO ETHERNET AND C-RAN LINK CHARACTERIZATION

Extensive range of models covering all telecom testing applications. Flexible design, allowing up to three wavelengths in a single module

FOT-930 MaxTester MULTIFUNCTION LOSS TESTER

Intelligent Optical Link Mapper (iolm)

FTBx-750C Metro/Long-Haul OTDR LONG-DISTANCE FIBER CHARACTERIZATION AND FIBER UPGRADES

FG-750 Client API SDN-READY INTELLIGENT OTDR

AXS-100. Series NETWORK TESTING OPTICAL HANDHELD OTDR. Compact, rugged, lightweight OTDRs optimized for access/fttx and LAN/WAN network testing

MaxTester 730B FTTx/MDU PON OTDR

Event dead zone: 0.8 m. Attenuation dead zone: 4 m. Dynamic range: up to 50 db. Platform compatibility. FTB-200 Compact Platform

FTB-735C Metro/PON FTTx/MDU OTDR

FastReporter 2 DATA POST-PROCESSING SOFTWARE

Link loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team

MaxTester 715B Last-Mile OTDR

MaxTester 730B PON/METRO OTDR

AXS-100 Series HANDHELD OTDR. Telecom Test and Measurement

FastReporter 2 DATA POST-PROCESSING SOFTWARE

Intelligent Optical Link Mapper (iolm)

FTBx-730C PON FTTx/MDU OTDR OPTIMIZED FOR FTTx/MDU FIBER DEPLOYMENTS AND TROUBLESHOOTING

intelligent Optical Link Mapper (iolm)

MaxTester 715B Last-Mile OTDR

MaxTester 715B Last-Mile OTDR POINT-TO-POINT (P2P) LINKS, LAST-MILE INSTALLATION AND TROUBLESHOOTING

MaxTester 715B Last-Mile OTDR POINT-TO-POINT (P2P) LINKS, LAST-MILE INSTALLATION AND TROUBLESHOOTING

740C xwdm OTDR Series C-BAND DWDM AND 18-WAVELENGTH CWDM TUNABLE OTDR SERIES FOR METRO ETHERNET AND C-RAN LINK CHARACTERIZATION

FastReporter 2 DATA POST-PROCESSING SOFTWARE

MINI2. Inno Mini 2 Specs Provided by MOST ACCURATE COMPACT OTDR

MINI2 MOST ACCURATE COMPACT OTDR

M700-Series Multifunction OTDR

M210 Multifunction Micro OTDR

VIEW500 FASTEST STANDARD OTDR

M310 Enterprise OTDR. Designed for Enterprise Network Testing, Troubleshooting and Documentation. or (800) , (603)

M310 Data Center OTDR

FLX380-30x FlexTester OTDR

M210 Multifunction Micro OTDR

FTTH NETWORK TESTING: REAL APPLICATIONS USING THE OLTS METHOD

MaxTester 730C PON/METRO OTDR OPTIMIZED FOR FTTx/MDU FIBER DEPLOYMENTS AND TROUBLESHOOTING, SUITABLE FOR METRO

OPX-BOX. Platform Highlights. Software Support. Key Features

VIEW500 USER-FRIENDLY STANDARD OTDR

M310 Enterprise OTDR. Designed for Enterprise Network Testing, Troubleshooting and Documentation. or (800) , (603)

M700-Series OTDRs. or (800) , (603)

Noyes OFL 250B Specs Provided by

THE ENTRY-LEVEL SOLUTION DESIGNED FOR ALL YOUR TESTING NEEDS

EXECUTING HIGHLY ACCURATE FIBER MEASUREMENTS IN A FRACTION OF THE TIME

palmotdr Series Handheld OTDR

OTDR II. Tier-2 Optical Time Domain Reflectometer for Multimode and Single-mode Fiber Cabling

OptiFiber Pro OTDR Built for the enterprise

M210 Multifunction Micro OTDR

AV6416 OTDR. Product Overview: Main Features:

MicrOTDR. Optical Fault Locator. User Manual

MTTplus Modular Test Platform

Fibre (TIA) Field Test Specification

Kingfisher KI-3800 Light Source. Inexpensive handheld source for testing and commissioning optical fibre networks. Compact and rugged,

OptiFiber Pro OTDR Built for the enterprise


Certified Fibre Optic Specialist - Testing

FLX380-30x FlexTester3 OTDR

OLTS vs OTDR Tier-2 Expert; How far from Tier-1?

High cost performance choice

OPX-BOXe Rugged, Pocket-sized Mini OTDR

FX150 OTDR. Platform Highlights. Key Features

Agilent E6000A E6003A Specs Provided by E6000C Mini-OTDR. Technical Data Sheet

MADE FOR THE TRADE! FIBER OPTIC. professional. XL fibertools Series. instruments

Wilcom. Model FR2 Fiber Ranger Optical Fault Locator OPERATING INSTRUCTIONS

High cost performance choice

MADE FOR THE TRADE! FIBER OPTIC. professional. XL fibertools Series. instruments

FG-750 Access (P2P)/Metro/Core OTDR-BASED REMOTE FIBER TEST SYSTEM

100B MINI-OTDR FTB-100B. EXFO s rugged, flexible OTDR-dedicated portable platform. Telecommunications Test and Measurement

Agilent 81663A DFB Laser 8165xA Fabry-Perot Lasers

AE2200 FTTx Multi-Function Meter

Ensuring the Health of Tomorrow s Fiber LANs Part II OTDR Trace Analysis Become an Expert Troubleshooter with Advanced OTDR Trace Analysis

The True Value of Connector Inspection: New Challenges and Best Practices

palmotdr Series Handheld OTDR

DWDM OTDR with Tunable Laser MTP-200-D100. Hand-held High Performance OTDR. Series

Datasheet: OptiFiber Pro OTDR

The Definitive Handheld OTDR for FTTx Testing OTDR AXS Compact, lightweight handheld OTDR optimized for access/fttx network testing

A. General: Horizontal and backbone cabling shall be verified in accordance with ANSI/TIA/EIA-568-C and the addendum for fiber optic testing.

The Rise of Tier 2 Testing

FHO5000 Series Triple-Proof OTDR

ACCESS Master MT9085 Series. Product Introduction

Fiber Guardian. Fiber Guardian. Where fiber monitoring starts. Key Features

Agilent E6012A Specs Provided by E6000C Mini-OTDR. Technical Data Sheet

Field Testing and Troubleshooting of PON LAN Networks per IEC Jim Davis Regional Marketing Engineer Fluke Networks

VePAL FX300 Fiber Expert OTDR

OPX-350 Series. Fiberizer Cloud. Universal Performer for Fiber Testing. Add value with. Test and Measurement in Fiber Optics

OWL. Laser OWL Series. Operations Guide. Singlemode Light Sources. Optical Wavelength Laboratories. Date: October 1, 2015

Datasheet: OptiFiber Pro OTDR

AE3100A~M Series 2-and 4-Wavelength Handheld OTDR

Instruments Designed for POF & Fibre Optic Cable Testing

GO BEYOND OTDR LEAVE NO FAULTY NETWORK BEHIND. intelligent Optical Link Mapper

OTDR. Optical Time Domain Reflectometer. User Guide

M-Series Compact OTDRs User s Guide

Datasheet: OptiFiber Pro OTDR

FLX380 and OFL280 FlexTester Series

Transcription:

ENCIRCLED FLUX (EF) TEST SOLUTIONS Tier-1/2 solutions with controlled source launch conditions for maximum accuracy and repeatability designed to remove uncertainty from multimode fiber testing. KEY FEATURES APPLICATIONS EF-compliant as per TIA -526-14-B and IEC 61280-4-1 Ed. 2.0 Data center/high-speed links Optimized for multimode loss testing Enterprise and private networks Tier-1/2 testing of multimode fibers as recommended in TIA-568 Reference-grade UPC connectors for maximum precision and repeatability Built-in-EF-compliant light source no extra equipment to manipulate COMPLEMENTARY PRODUCTS AND OPTIONS AXS-110 FLS-140 FastReporter2 Data Post-Processing Software SPEC SHEET SPSB-EF LAUNCH MODE CONDITIONNER AND FLS-600-NS1548 LIGHT SOURCE DESIGNED FOR CONTROLLED MULTIMODE LOSS TESTING

UNDERSTANDING EF Encircled Flux (EF) is a new standard that defines how to control the source launch conditions as specified in TIA-526-14-B and IEC 61280-4-1 Ed. 2.0. Whether for an expanding enterprise business or a large-volume data center, the new high-speed data networks built with multimode fibers are running under tighter tolerances than ever before. These MM fibers are the trickiest links to test because the results depend greatly on each device s output conditions. Testing with different equipment often returns different test results, sometimes higher than the budget loss itself. This may mislead the technician or make it impossible to locate the fault, resulting in unsuccessful turnups or a longer network downtime. Now, cable installers can rely on their Tier-1 loss results and Tier-2 troubleshooting can be performed with maximum accuracy and utmost confidence of finding the actual problem. CONSISTENCY AND REPEATABILITY Whether built-in or packaged in the external launch conditioner, EXFO tunes each EF-compliant device to perfection in-house, ensuring that every unit meets the EF templates for both 850 and 1300 nm at 50 μm. This allows technicians and contractors to obtain reliable, consistent and repeatable results during construction, thus eliminating doubts and uncertainty. The test documentation that is generated will also help future-proof networks. When upgrades are needed, it will become easier and faster to know which circuits have to be activated, thereby saving time and troubles down the line.

TWO FIELD SOLUTIONS TO CHOOSE FROM MULTIMODE LIGHT SOURCE FOR CONSTRUCTION (TIER-1 BASIC) MULTIMODE OTDR FOR TROUBLESHOOTING (TIER-2) ef-compliant test Solutions FLS-600-NS1548 FLS-600 FtB-720 LAN/WAN Access otdr FtB-7200D LAN/WAN Access otdr AXS-110 All Fiber otdr EF Launch Conditions Built-in with reference grade jumper Paired with External Mode Conditioner (SPSB-EF-C30) Paired with External Mode Conditioner (SPSB-EF-C30) Key Benefit No extra tool to carry No need to use mandrels Leverage your existing FLS-600 Get EF compliance with low cost of ownership Compatible with iolm multimode troubleshooting tool (FTB-720 only) New or existing EXFO OTDRs can be retrofi tted with equipment in the fi eld Results Accurate and repeatable insertion loss (IL) measurement for successful turn-ups Undoubtful and accurate fault location for quicker link repair, reducing mean time to recovery (MTTR) Description Key Features Like all EXFO portable instruments, the FLS-600 is built for the harshest test conditions. It features a keypad with LCD backlight, for easy operation in darker environments. Combined with an FPM-600 power meter, it automatically selects the testing wavelengths and sends the reference power value to ensure accurate results. EF-compliant for basic Tier-1 certifi cation Four wavelengths on two ports: 850/1300 nm and 1310/1550 nm 3-year warranty for low cost of ownership Error-free, time-saving test features Packaged in a soft, light and convenient carrying case, it is compatible with EXFO OTDRs and the FLS-600 series. It includes 30 m of fi ber to be used as a launch cable with OTDR. Covers OTDR dead zones, enabling loss measurement on the fi rst and last connections of a fi ber under test Increases the life of the source connector by reducing the number of matings on the connector Supports LC/UPC and SC/UPC connectors Outcome Build and maintain a future-proof multimode fi ber network with utmost reliability and accuracy. Note: EF-compliant launch conditions with SPSB-EF external launch conditioner can only be acheived when paired with EXFO products as listed in this table. This may not be possible with OTDRs or light sources from other manufacturers.

THE NECESSITY OF LAUNCH AND RECEIVE CABLES Encircled Flux Link characterization is often performed using an OTDR. However, despite the fact that an OTDR has the shortest dead zones, the way loss is measured in a link means that to characterize the first and last connectors, an OTDR needs a launch cable, also called a pulse suppressor box. The reason for this is that the loss associated with an event is the difference between the backscattering levels measured before and after the event. To account for the dead zone, a backscattering level must be obtained before the first connector. This requires inserting a length of fiber between the OTDR port and the first connector of the fiber under test. At the other end, the same length of fiber is inserted after the last connector. In order to measure the loss of the first and last connectors, it is important to use launch and receive cables. The SPSB-EF has an internal 30-meter fiber that allows complete end-to-end loss while still maintaining the EF launch conditions up to the first connector of the link. By complying with the EF standards, faulty connectors are easily located when troubleshooting high-speed multimode links. Note: To measure the loss in the first connector with the SPSB-EF launch cable, the OTDR pulse width should be 100 ns or shorter and the connection to the OTDR port should have a relfection value of -45 db or better. A 50 μm test link must also be selected.

SPECIFICATIONS FLS-600-NS1548 a Model 12C 23BL Central wavelength (nm) 850 ± 25 1300 +50/ 20 Spectral width b,f (nm) 50/135 5 Launch conditions f Encircled flux compliant at 850 nm (guaranteed) at 1300 nm (typical) Auto-switching Yes Yes 1310 ± 20 1550 ± 20 Tone generation 270 Hz, 1 khz, 2 khz 270 Hz, 1 khz, 2 khz Battery life (hours) (typical in Auto mode) 50 50 Warranty (years) 3 3 GENERAL SPECIFICATIONS Size (H x W x D) 190 mm x 100 mm x 62 mm (7 1 /2 in x 4 in x 2 1 /2 in) Weight 0.48 kg (1.1 lb) Temperature operating storage Relative humidity 10 C to 50 C 40 C to 70 C 0 % to 95 % non-condensing (14 F to 122 F) ( 40 F to 158 F) STANDARD ACCESSORIES User guide, Certificate of Calibration, instrument stickers in six languages, AC adapter/charger, lithium ion battery, shoulder strap, carrying case. LASER SAFETY SPSB-EF SPECIFICATIONS EXTERNAL LAUNCH MODE CONDITIONER SPECIFICATIONS Model SPSB-eF-C30 Total connector insertion loss (db) d < 1 Fiber length e Launch conditions f Optical source for EF compatibility Available connectors 34m / 112 ft Encircled flux compliant at 850 nm (guaranteed) at 1300 nm (typical) FLS-600-12D, AXS-350-12D, FOT-930-12D, FTB-720-12D, FTB-7200D-12D, AXS-110-12D SC to LC SC to SC NoteS a. Guaranteed unless otherwise specified. All specifications valid at 23 C ± 1 C. b. rms for FP lasers; and 3 db width for LEDs (typical values for LEDs). c. After a 15-minute warm-up period, and using an APC connector on the power meter (except for multimode sources, for which a PC connector is used). Expressed as ± half the difference between the maximum and minimum values measured during the period. d. Using a 50 μm fiber at the input of the SPSB-EF e. To measure the first connector loss, reflection value of OTDR port must be -45 db or better and a maximum pulse width of 100 ns. f. Compliant with TIA-526-14-B and IEC 61280-4-1 Ed. 2.0

GENERAL SPECIFICATIONS Size (H x W x D) 165 mm x 165 mm x 40 mm 6½ in x 6½ in x 1 9/16 in Weight 0.3 kg 0.7 lbs Temperature operating storage Relative humidity 10 C to 50 C 40 C to 70 C 0 % to 95 % non-condensing 14 F to 122 F 40 F to 158 F ORDERING INFORMATION FLS-600-NS1548-XX-XX-XX Model 12C = 850/1300 nm LED source 50/125 μm 12C-23BL= 850/1300 nm LED source 50/125 μm, 1310/1550 nm laser source 9/125 μm Multimode Connector a EI-EUI-91 = UPC/SC EI-EUI-98 = UPC/LC Singlemode Connector b EI-EUI-28 = UPC/DIN 47256 EI-EUI-76 = UPC/HMS-10/AG EI-EUI-89 = UPC/FC narrow key EI-EUI-90 = UPC/ST EI-EUI-91 = UPC/SC EI-EUI-95 = UPC/E-2000 EI-EUI-98 = UPC/LC EA-EUI-28 = APC/DIN 47256 EA-EUI-89 = APC/FC narrow key EA-EUI-91 = APC/SC EA-EUI-95 = APC/E-2000 EA-EUI-98 = APC/LC Example: FLS-600-NS1548-12C-23BL-EI-EUI-91-EA-EUI-91 SPSB-EF-XX-XX Model C30 = Encircled flux external launch conditioner, multimode fiber 50/125 μm, 34 meters including pigtails Connector c 91-91 (SC/UPC to SC/UPC) 91-101 (SC/UPC to LC/UPC) Example: SPSB-EF-C30-91-101 Notes a. For multimode port b. For singlemode port c. First connector to source port must be SC-UPC only EXFO Headquarters > Tel.: +1 418 683-0211 Toll-free: +1 800 663-3936 (USA and Canada) Fax: +1 418 683-2170 info@exfo.com www.exfo.com EXFO serves over 2000 customers in more than 100 countries. To find your local office contact details, please go to www.exfo.com/contact. EXFO is certified ISO 9001 and attests to the quality of these products. EXFO has made every effort to ensure that the information contained in this specification sheet is accurate. However, we accept no responsibility for any errors or omissions, and we reserve the right to modify design, characteristics and products at any time without obligation. Units of measurement in this document conform to SI standards and practices. In addition, all of EXFO s manufactured products are compliant with the European Union s WEEE directive. For more information, please visit www.exfo.com/recycle. Contact EXFO for prices and availability or to obtain the phone number of your local EXFO distributor. For the most recent version of this spec sheet, please go to the EXFO website at www.exfo.com/specs. In case of discrepancy, the Web version takes precedence over any printed literature. SPEF.1AN 2013 EXFO Inc. All rights reserved. 2008 Printed in Canada 13/12