I760B-DX BGA Rework System. Operation Manual

Similar documents
QK-IR2005. User s Manual

QUICK BGA2005. Operation Manual

QUICK BGA2015 BGA/SMD Rework System. Operation Manual

NOTEBOOK I 760 BGA/SMD Rework System. Operation Manual

QUICK BGA 2025 BGA/CSP Rework Station Operation Manual

QUICK BGA2015. Precision BGA Rework System. Features:

QUICK EA-A10. BGA/CSP Rework Station. Operation Manual

Instruction Manual QUICK 855PG PROGRAMMABLE SMD REWORK STAION

HRS55PG PROGRAMMABLE SMD REWORK STAION. Instruction Manual. Thank you for purchasing our SMD Rework station. The unit is exclusively designed for

SMD REWORK SYSTEM. Instruction Manual 401H000505

34737-TL SMD REWORK STATION

Intelligent Lead Free Soldering Station OPERATION and MAINTENANCE MANUAL

S ATION EWORK ST BGA R

JOVY SYSTEMS RE User Manual Rev. 1.00

S ATION EWORK ST BGA R

JOVY SYSTEMS RE-7500 User Manual Rev Index

Desoldering Tool. New. Portable Desoldering Tool. Packing List. Specifications

Mini SMT Reflow Oven Model: T-961

BGA Rework Station TOUCHBGA GM490 User Manual

WHA 3000V Hot Air Station

INFRARED IC HEATER Model: T962C. User Manual.

ASE-4313 Users Manual

Big Board Rework. Joerg Nolte Ersa GmbH Wertheim, Germany

LED New Light Source Reflow Oven. Model: T-960

SHENZHEN ZHUOMAO TECHNOLOGY CO., LTD. BGA Rework Station ZM-R5860C Instruction Manual

METCAL QX2 CONVECTION REWORK SYSTEM USER GUIDE

E S D REWORK SYSTEM 3 IN 1, I702 USER S GUIDE

BGA Rework Station Pro-660

Operating Manual. for. SMD/BGA Rework System IR860

touchbga.com TOUCHBGA BGA Rework Station HR6000 User Manual

Ersa IR 550 A plus Microprocessorcontrolled Rework System

Shenzhen SCOTLE Technology 深圳市玉海源科技有限公司 SHENZHEN SCOTLE TECHNOLOGY LTD

WHA 3000P Hot Air Station

DSSHP06G Intelligent Lead Free Soldering Station INSTRUCTION MANUAL

touchbga.com TOUCHBGA BGA Rework Station GM330 IR+HR User Manual

Operation and Maintenance Manual for the SODRTEK ST 325 Digital Convective Soldering/Desoldering System P/N

SMD Rework Station with Vacuum Pickup Instruction Manual TABLE OF CONTENTS

LY R690 Touch Screen BGA Rework Station User Manual

QUICK 3202 OPERATION MANUAL. Lead Free Soldering Station

Accessories for WHA 3000P and WHA 3000V

SMD Rework Technology Complete solutions

SMD Rework Technology Complete solutions

THROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER. Instruction Manual. Model AMB-12H

OPERATION MANUAL WARNING TAIYO ELECTRIC IND.CO.,LTD. MODEL XPR-600 PREHEATER

INFRARED IC HEATER. Model: T962. User Manual

OPERATING MANUAL FOR LF-852DII HOT-AIR S.M.D. REWORK STATION

Repair under control

SS-969 SMD Rework Station

4 Port Rework Station with 140 desoldering gun, M-type soldering iron and 670W hot air

Lead Free Soldering Pot I100-15S

User Manual. Dryer Controller M720

DSSLF2X04H 2 IN 1. Intelligent Lead Free Soldering Station. OPERATION and MAINTENANCE MANUAL

EST User Manual. (Please read this manual carefully before using)

HA06. User manual. (SDO Hot Air One) HOT AIR / QUARTZ REFLOW OVEN. Version 2.21

Table Of Contents

ERSA IR 500 A SMT/BGA Rework System

AOYUE. Int 852A+ pro Int 852A++ pro. SMD Rework Station INSTRUCTION MANUAL. (Centigrade / Fahrenheit switchable)

Contents 1. GENERAL DESCRIPTION TECHNICAL DATA INSTALLATION...4

Reflow Soldering Guidelines

User Manual. TN6900 H&E Slide Stainer. Read Prior to Operation! Always keep this manual near the unit! WP

CO 2. Incubators. Incubator, the first microprocessor-based system, and the first menu-driven control system, but we offer the

Dryer Controller M720

NTS STRUME IN N-ON DE

over 100 are used all over India by our top customers many with repeat... repeat orders

QA16 Addressable System

SMT & Area Array Rework

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual

RD-500V RD-500SV ESD SMT REWORK SYSTEM

Operating Instructions ERSA IR 500 A SMT / BGA Rework System 3BA

premium line Stations Different equipment designed for a specific soldering or rework job

AOYUE INT. Advanced Repairing System NT 701A++ INSTRUCTION MANUAL. Correct Disposal of this product

E1000 Portable gas detector

QD6310. Fixed Gas Detector Operation Manual

Instruction Manual. SMD Rework Station with Vacuum Pickup TABLE OF CONTENTS

IMR EX610. Portable Gas Detector. Operation Manual

Instruction Manual. for. Soldering / SMD Rework Station. For Lead-free soldering application and rework on professional SMD electronics.

Electronic Pellet Burner Controller NPBC-V3M

Digital LEAD FREE. Soldering Soldering. Temperature range. Station. N1-06 Nozzle ø0.6 N1-08 Nozzle ø0.8 N1-10 Nozzle ø1.0 N1-13 Nozzle ø1.3. ø2.

Electronic Pellet Burner Controller NPBC-V3-1

ZSC100 Gas Detection and Alarm System Controller

Ontech GSM 9040/50. Reference Manual English -1 -

User s Manual. CONCEPT Processor 305 DW / 405 DW / 505 DW 505 DW XP

Danfoss gas detection units

User Manual. Reflow Batch Oven Model: X-REFLOW305

EDR Series. Model. Instruction Manual. Rev 5.0. Thank you for purchasing the EDR Auto Smart.

FR-1012B Operation and Maintenance Manual

SMD Rework Station TABLE OF CONTENTS

Key Features & Benefits w Digital display for repeatable w Automatic control of the preheater for w Easy profile creation for operator

User Manual. Tanner 1500 Embedding Center

Hot Air Station Ref. JT-B

Instruction Manual. ZM-R6200 Rework Station. comercialreballing.ro tel Cluj-Napoca, Calea Motilor 43, RO

SMD Rework Station with Vacuum Pickup. Instruction Manual

Focus 4010\ Focus 4010 HT porcelain firing furnace

FULL CONVECTION REFLOW OVEN

RD-500V RD-500SV ESD SMT REWORK SYSTEM

TAC-09CHSA/*** TAC-12CHSA/*** TAC-18CHSA/*** TAC-24CHSA/*** SERVICE MANUAL WALL MOUNTED SPLIT-TYPEAIR CONDITIONERS. No.TE1307.

TV2 Room Pressure Monitor Quick Start Guide

INSTRUCTION MANUAL Soldering Station Ref. LC-2SIA

aoyue Int732 INSTRUCTION MANUAL Game Console Reworking System

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

Transcription:

I760B-DX BGA Rework System Operation Manual Thank you for purchasing our IR Rework System. The system is exclusively designed for reworking and soldering SMD component. Please carefully read this manual before operating the system. Store this manual in a safe, easily accessible place for future reference.

Table of Contents 1. Summary 1 2. Specifications and Technical Parameter 1 2.1 Specifications 1 2.2 Technical Parameter 2 3. Product Picture 2 4. Safety Instructions 3 5. Install the Unit and Adjust Parts 3 5.1 Place the Unit 3 5.2 Check the Pack 3 5.3 Connect the Unit 4 5.4 PCB Fixture 4 6. Keys and Parameter Setting 5 6.1 Keys Instruction 5 6.2 Parameter Setting 5 A. Input Password 6 B Modify Workflow 7 C Modify Working Flow 7 C-1. Modify Parameter of Working Flow 8 D. Modify Laser Alignment Mode 12 E System Instruction 13 7. Technics Instruction 13 7.1 Soldering Technics (Switch on the System s Power) 13 7.2 De-soldering Technics (Switch on the System s Power) 14 8. Turn Off the System 15 9. Maintenance 15

1. Summary Thank you for using QUICK 760B Rework System. This system adopts micro-processor control and infrared sensor technology to do soldering and de-soldering to surface mount components safely and accurately and it can also control the whole technological process and record all information by means of the IR Software, thus meeting the higher technological demands of modern electronic industry. It becomes one of the most valued electronic equipments in this field. This Rework System adopts microprocessor control and infrared sensor technology. It has the precision non-contact infrared temperature sensor for de-soldering parts and the middle wavelength infrared heater. The soldering process is under the monitoring of non-contact infrared sensor and optimum control of process can be achieved at any time. In order to get the best technological control and the nondestructive and reproductive PCB temperature, I760B supplies a 2200W heating power, suitable for all application, such as large or small PCB as well as lead-free process. The technology of re-flow soldering controlled by closed-loop ensures the precise and smaller technological window, even heat distribution and appropriate peak value of temperature for lead-free soldering. The infrared heating tube of QUICK 760B, With a uniform and safe heating and power systems and the flexibility necessary for the large heat capacity of PCB and other high temperature requirements (lead-free soldering), etc. can be easily addressed QUICK 760B with 10 kinds of operating parameters of model, a model for each parameter can be modified. In addition QUICK 760B also provides effective cooling of the PCB board, for professional users is a complete, ideal soldering tool. 2. Specifications and Technical Parameter 2.1 Specifications 1. Max Power 2200W max 2. Power of Bottom preheating 1500W (Infrared heating tube) 3. Power of Top heating 720W (Infrared heating tube, Size: 60m 60 mm) 4. Preheating time of Bottom 260*260mm Heater 5. Adjusting rang of Top Heater 20~60mm 6. Heating time of Top Heater Approx 10s ( From room temperature to 230 ) 7. LCD display screen Size: 65.7 23.5 (mm) 16 2 character 8. Communication Standard RS-232C (Connect with PC) 9. Infrared Temperature sensor 0~300 (Testing range) 10. Outside K type sensor Optional 11. Dimension 33 38 44 (cm) 12. Weight 20Kg Note: When purchasing the equipment, please point out the working voltage. Page 1

2.2 Technical Parameter TL: Melting temperature of solder T1: Heat preservation starting temperature of reflow soldering T2: Heat preservation ending temperature of reflow soldering T3: Peak value temperature of soldering and de-soldering T0: Valve temperature: The lowest temperature of bottom heater when top heater heats up. T0<TB TB: The set temperature of bottom heater Tb: The real time temperature value of bottom heater TC: The real time temperature value of top heater S1: Heating time rising from T1 to T2 S2: Heating time rising from T2 to T3 S3: Heat preservation time of T3 3. Product Picture Display Top infrared heater Bottom infrared heater Page 2

4. Safety Instructions Note: For the safety of system and operator, please read this manual carefully before operating the unit. Please note that the unit is suitable for soldering and de-soldering of electronic components. CAUTION: Top and bottom IR heater will be very hot during working, so explosive and combustible object or gas and solvent is strictly prohibited in working areas, also please don touch the hot housing parts. CAUTION: Because the laser alignment device includes a laser device Class II, don t see the laser bean directly. CAUTION: When the system is in trouble and needs maintenance, it should be maintained by an experienced and authorized technicist or maven, or you can contact with service agent or our company. The inside of the unit with dangerous voltage! The inexperienced servicing is dangerous for operators. 5. Install the Unit and Adjust Parts 5.1 Place the Unit Unwrap the packing of the unit, then take it out and put it on the solid level worktable. Put I760B main unit on the base plate. 5.2 Check the Pack Please check whether the following parts are in good condition and they aren t missed. * I760B Main unit * IR Base plate with PCB Fixture (Optional) * Power cord * Operation Manual * IRsoft Disc * RS232 cable * External cooling fan (selected parts) Note: The parts will be packed according to the packing list, if you don t purchase the optional part and it isn t in the package. If any above part is missed out, please contact with our company or agents immediately. CAUTION: Top and Bottom heater will be very hot during working, so explosive and combustible object or gas and solvent is strictly prohibited in working areas, also please don touch the hot housing parts. Page 3

5.3 Connect the Unit * Please check whether the power voltage according with the rated voltage on the equipment nameplate. * Please check whether the switches are turned off. (Set to 0 ) * Connect Power cord to the power socket behind equipment. * If you use IR Soft, please connect the RS232 connecting cord to the RS232 socket behind the unit. After finishing above steps, insert power plug into power socket, and switch on power. 5.4 PCB Fixture PCB Lock Knob Supporting bar at the bottom of anti-collapse Fixing screws of fore-and-aft moving 1. Fore-and-aft moving distance is more than 100mm. 2. Maximum moving distance from left to right is about 400mm. 3. Maximum height can be used is about 92mm. 4. PCB Fixture Dimensions: 700 L * 580(W) * 170(H)mm 5. Movable PCB fixture is able to fix PCB with different size. The Lock Knobs lock PCB Fixed Bar to fix PCB. Unscrew PCB Lock Knobs and push Sliding Blocks by hand to open PCB Fixed Bars, make the distance between PCB Fixed Bars accord with the PCB size. Fix PCB between them and screw down PCB Lock Knobs after adjusting position. PCB Lock Knob PCB Fixed Bar Sliding Block 6. Keys and Parameter Setting Page 4

6.1 Keys Instruction 1. During selecting working flow period, + and - keys are used for controlling the cursor moving upward or downward and increasing or decreasing the number. 2. During the soldering or de-soldering period, also top IR heater haven t yet started to heat up, key + and key - are used for controlling movement upward or downward of top IR heater. That is to say, during movement upward and downward of top IR heater, after pressing the key BEGIN, + and - keys make the top heater stop at a proper position. 3. Under the standby condition, if the cooling fan has already drawn back, press + and - keys to make the top IR heater move up and down. 4. Under the standby condition and the top IR heater is at top position, press ALIGN key, the cooling fan (it has laser alignment device inside) will hold out or draw back. When cooling fan completely holds out, the laser alignment device will switch on automatically. After the cooling fan has held out, if you double click ALIGN key, the cooling fan will be on or off. 5. Function of OK : When in the settings so that the cursor BGA-IR menu to return to higher levels, until the return of user interface, and save the changes the result. 6. Function of SET key: Make the BGA-IR enter parameters setting mode and cursor move a step forward. 7. Function of Delay Key: During the soldering or de-soldering process, pressing this key, make the setting value of S3 delays five seconds after the temperature up to T3. If pressing the key continuously, the time of heating (S3) continuously prolongs. 8. Function of FAN Key: Make the external cooling fan to work or to stop. 9. Function of STOP key: During the setting mode, make BGA-IR cursor exit until to the setting mode. During the soldering or de-soldering process, make BGA-IR exit operation. 10. Function of START key: During the standby condition, make BGA-IR get into soldering or de-soldering situation. 6.2 Parameter Setting Parameter settings order as the followings: A. _password: *** Password settings B. _ (Flow settings, it can modify parameter inside.) C. _type: solder Working mode settings D. _laser: off (Laser alignment settings) E. _baud: 19200 Communication speed settings A. Input password The initial password of system is 000. At the same time, system also has the omnipotent password 159. If you forget the setting password, you can input 159 to make the password of system come back to initial password 000. Note: If want to modify parameter of system, you must input correct password, otherwise, you only Page 5

can browse them. For instance: Input the initial password 000. When in initial state, TC, Tb display room temperature. TC:022 Tb:019 _password: *** ready for flow password: *** Press - password: 0** password: 0** Press - password: 00* password: 00* Press - password: 000 Press OK Saving Password! Any key return Password input complete 1. If want to change the password, it needs enter into this mode and input the new password as password inputting. If changing successfully, the display shows as following: Saving Password! Any key return 2. If want to change the workflow, it needs enter into the next step B. Modify workflow. If not need to change, press - key can see the parameter data. Page 6

B Modify workflow For example: to amend the process. So that the workflow for the process1: password: *** Press - password: *** Step Step password: *** Press + password: *** Press OK Step select: 1 Step password: *** select: 1 1. When carry on the forth step (Step ), if press SET key, you can browse and modify parameter of this flow, shown as C-1 item. 2. After finishing modifying of working flow 1, if you want to modify the next working mode, operate as C item shows; If you don t want to modify it, yon can press - key to browse the next parameter settings. C Modify Working Flow For instance: Modify the working flow and make it become 1 flow. password: *** Press - select: 1 select: 1 type: solder select: 1 Press - + select: 1 Press OK type: solder Page 7 type: desolder

select: 1 type: desolder C-1. Modify Parameter of Working Flow 1. If it is necessary to modify parameter of a working flow, first you must select the working flow and then modify its parameter. 2. The modification of parameter must be according with the following technics graph. TL T3 TB Tb=T0 S2 S3 T1 T2 Tb TC S1 denote: Tb denote: TC 3. The soldering technics is decided by the parameters of T0, TB, T1, T2, T3, S1, S2 and S3. It describes the temperature curve during the system working. TL denotes the melting temperature of the solder and the temperature range between T2 and T3. T0 T0 is the valve temperature of the top heater comes to heat up. Also it is the first temperature of this technics process. When the workflow begins, the bottom heater starts to heat up. After reaching the T0, the top heater begins to heat up. TB, Tb, TC TB: The setting temperature of the bottom preheating. Tb: Real-time temperature of the bottom heating. TC: Real-time temperature of the top heating. T1 It is the heat preservation starting temperature of reflow soldering. It is the second temperature of this technics process. The temperature rises to T1 with a proper speed the component permits. In parameter modifying, use the and key to set the value of T1. Page 8

T2 It is the temperature when finish the heat preservation of reflow soldering. The pre-heating temperature rises to T2, after the time of S1 finishes. Within this time, PCB and component pre-heating is finished and the solder is activated. In parameter modifying, use the and key to set the value of T2. T3 It is the peak value temperature of reflow soldering. When the temperature reaches T2, the temperature equably rises to T3 with a definite raising speed. The soldering or de-soldering will be finished when the temperature reaches to the peak value and performs the next step. In parameter modifying, use the and key to set the value of T3. TL Melting temperature of solder. At this temperature, the solder starts to melt down and turn into liquid. During the soldering and de-soldering, users can press CALTL Key to calibrate the value of TL when the solder turn into liquid. In parameter modifying, use the and key to set the value of TL. S1 Heating time rising from T1 to T2. User can set the value in the range of 0~300s. S2 Heating time rising from T2 to T3. User can set the value in the range of 0~300s. S3 Prolonged heating time (Heat preservation time) after the temperature reach T3, and user can also set the value in the range of 0~300s. Unit It s able to set the unit of display temperature during work flow. In parameter modifying, use and keys to set the value of it. Sense It is used for choosing the system s sensor type. Users can also choose K type sensor used for measuring temperature, besides system s IR sensor. The signal of chosen sensor will be displayed and used for process controlling. In parameter modifying, use the and key to set the value. Password It is used for setting password. It is designed for preventing the equipment unnecessary or non-authorized change. When it is set to 000, the password protecting is useless. The password is used for all flows and it can be useful and useless in each flow. The system requires inputting correct password before any change. Using of password refer to A item. For instance: Modify parameter of flow one (Flow one has been selected) and make T1=130, S1=70s, T2=160, S2=50s, TB=130. password: *** _T1: 110 select: 1 Page 9

T1: 110 T1: 110 Press + 2 T1: 130 Press OK Press - _T1: 130 T1: 130 T1: 130 _ T1: 130 Press + T1: 130 S1: 070s Press OK T1: 130 Press - S1: 070s S1: 070s T2: 150 S1: 070s T2: 150 Press + T2: 150 T2: 160 Press OK Press - T2: 160 T2: 160 Page 10 T2: 160 S2: 030s S2: 030s

T2: 160 Press + two times T2: 160 Press OK S2: 030s S2: 050s T2: 160 S2: 050s Press - Press - S2: 050s T3: 200 T3: 200 S3: 010s Press - Press - S3: 010s TL: 183 TL: 183 TL: 183 TB: 140 TB: 140 TL: 183 Press - TL: 183 Press OK TB: 140 TB: 130 TL: 183 TB: 130 Press - Press - TB: 130 T0: 090 T0: 090 unit: Press - Press - unit: sense: IR Senser: IR type: desolder Page 11

D. Modify Laser Alignment Mode For instance: Modify the laser alignment mode and set it to on. select: 1 Press - type: desolder type: desolder laser: off type: desolder laser: off type: desolder Press - or + Press OK laser: on type: desolder laser: on 1. After finishing the modification, the next step is the communication speed setting, will not be able modified by keyboard. 2. Press EXIT key to exit. Now, the system has saved all parameter settings, the window will display: TC:022 Tb:019 ready for flow 3. After all technological parameters have been selected, press BEGIN key and then the system perform the set flow. E System Instruction 1. In the initial state, if the top sensor or the outer sensor is broken, it displays: TC: *** Tb: *** T sense error! If the bottom sensor is broken, it displays: TC: *** Tb: *** Page 12 B sense error!

When happening above status, user must stop operating or do not begin the work process. 2. During work, when the TC (real temperature of the top heater) is below 180, if the temperature heating up is less 7 in10seconds, the system will enter into the protection process, exit from the heating flow and display TC raise error. At the time, it needs to restart and reposition the device before beginning work. TC: *** Tb: *** TC raise error! 3. If TC is more than 267 during working, the system will also exit the process and back to the initial state. 7. Technics Instruction CAUTION: Top and bottom IR heater will be very hot during working, so explosive and combustible object or gas and solvent is strictly prohibited in working areas, also please don touch the hot housing parts. CAUTION: Because the laser alignment device includes a laser device Class II, don t see the laser bean directly. 7.1 Soldering Technics (Switch on the System s Power) 1. Turn on the power switches of the each part. 2. Move PCB Fixture with fixed PCB to make PCB over the Bottom Heater and make the soldered component between Top Heater and Bottom Heater. The position is easy to be measured with laser alignment device. The right position should make the red laser point in the center of component. The component which to solder on the PCB have been aligned before soldering. 3. Adjust aperture system to get a proper window size. 4. Select parameter with keyboard. (Refer to Parameter setting ) 1) Input password 000 2) Select the required flow, if need to modify, perform relevant operation. 3) Select solder working mode. 4) Select IR laser alignment mode. 5) Not to change communication speed, and press OK key to exit. The window shows: TC: *** Tb: *** ready for flow Page 13

6) Press BEGIN key and the system starts to work, perform content of selected flow. 5. The window will show series of setting temperatures and the current temperature of Tb and TC during working, and indicate when it reaches T0, T1, T2, T3 and TL. S1, S2 and S3 are counted down and user can know about the setting value clearly. 6. When the temperature reaches TL, there will be a voice signal. 7. When the temperature reaches T3, the voice signal is change to a hurry sound and the system prolongs heating by S3 seconds, after it, the system will not heat up anymore, and the technical process is over. 8. The system can perform a series of function action during working. A. After press BEGIN key, the top heater move downwards near to bottom. B. After the system sounds unvaryingly, the top heater move upwards and cooling fan spread out to blow cooling wind. 9. After the PCB cooling down to the befitting temperature, turn off the cooling fan to stop working and the whole process has finished. 7.2 De-soldering Technics (Switch on the System s Power) 1. Turn on the power switches of the each part. 2. Fix the PCB on the top of Bottom Heater and make the de-soldered component between Top Heater and Bottom Heater. The position is easy to be measured with laser alignment device. The right position should make the red laser point in the center of component 3. Adjust aperture system to get a proper window size. 4. Select parameter with keyboard. (Refer to Parameter setting ) 1) Input password 000. 2) Select the required flow, if need to modify, perform relevant operation. 3) Select desolder working mode. 4) Not to change communication speed, and press OK key to exit. the window shows: TC: *** Tb: *** ready for flow 5. After pressing BEGIN key, bottom heater starts to heat up and top heater moves downwards and reach to bottom. 6. IR window will show a series of setting temperatures during working. Indicate when it reaches T0, T1, T2, T3 and TL. When the bottom temperature reaches T0, the top heater begins to heat up. 7. When the temperature reaches TL, it will give a sound alert automatically (Low frequency). 8. When the temperature reaches T3, it will also give a sound alert automatically. (Middle frequency) 9. When the solder has melted down, take down the component and the top heater moves upwards and stops at the maximal position. 10. The outer cooling fan runs automatically and blows cooling airflow to cooing the PCB. After the cooling fan blows cooling wind for 150 seconds, the whole soldering technics finished. Page 14

8. Turn Off the System Please turn off the power switch of each part and pull out power plug when not using it. 9. System Maintenance Remark: For ensuring reliable function and maintenance of equipment, please use parts provided by original factory. Note: After cutting off the power supply, the housing is still very hot, so please do the clean after it has cooling down and don t use any dangerous or combustible solvent to clean it. Clean parts: Clean the dust on system with clean towel. Add lubricating oil periodically to the transmission part. Use the towel with cleaning oil to clean PCB fixture and orbit. Solder on the gridding of the bottom heater can be cleaned out with hard object. Page 15