Controls Surface mounted pushbuttons Suitable for gloved use. Buttons Side - On/Off Front Menu Scroll Pin Hole Setup access

Similar documents
Using the GammaRAE II Responder Personal Radiation Detector and Dosimeter in One. Firmware Version 3.00 D August 2006

Using the GammaRAE II Personal Radiation Detector

DMC 3000 Quick User s Guide

User s Manual. Electronic Personal Dosimeter (For Gamma(X)-ray) NRF30. Fuji Electric Co., Ltd. TN514629i 1/31

Personal Radiation Alarm Dosimeter LK Operating Instruction Manual. Contents

Dräger Pac Ex 2. Elegant and smart... Explosive hazards and lack or surplus of oxygen under control

RAM GENE-1 ERK. Contamination & Radiation Meter. Operating Manual. Document #PRIR90N2.DOC Version 2.2 October 2009

MODEL 23 AND 23-1 ELECTRONIC PERSONAL DOSIMETER. August 2017

Model R9400. Instruction Manual. CO Meter with Temperature. wwwreedinstruments. com

MINI-RADIAC INTRODUCTION

Operate the Mutli-Gas Monitor PID

Radioactivity dosimeter RD01. User's Manual

USER & INSTALLATION GUIDE

DYGIZONE GJD910 Lighting Controller & Enunciator

Zerio Plus EDA-D6000 Radio Combined Heat Detector and Sounder Installation Instructions

Bacharach Bodyguard 4 User's Guide

USER GUIDE Heat Index Psychrometer

NexSysLink. 2 CAN Display Operation Manual. CAN Instruments Product Family

Remote Display Alarm Indicator for Oxygen monitor

GasAlertMicroClip X3 Specifications

SmartVent. Keypad Controller User Guide Manual. NZ s Home Ventilation Specialists

RAD-60 USER GUIDE (ALSO FOR THE RAD-50 MODEL AND ISOTRAK DOSIMETERS)

SmartVent. Digital Controller User Guide Manual. NZ s Home Ventilation Specialists

RAM GENE / RAM GENE-1

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

Water Tank Level Monitor

Macurco Single-Gas XL Series Monitor, CM-1XL Carbon Monoxide (CO), HS-1XL Hydrogen Sulfide (H2S) User Instructions

Contamination Meter Users Manual

Dosimeters/Survey meters

INSTRUCTIONS FOR. Wireless Refrigerator Freezer Thermometer (#10378)

QUADRANT OPERATION and MAINTENANCE MANUAL

Introduction. OM-THA2

Intruder Alarm Kit IA-210 IA-220 IA-230

Enteral Pump Instructions for Use To Assemble When the low

INSTRUCTION MANUAL. 851 Transport Drive Valparaiso, IN SENSIT Technologies is in compliance with ISO 9001:2008.

ENGINE MONITOR VOTT MODEL: YEAR WARRANTY

DMC 3000 User s Guide

Operation manual. Rooftop Packaged Unit

RAE Systems. Using the MeshGuard. Protection Through Detection

Safety & Installation Instructions

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

PM1703MO-1A PM1703MO-1B PERSONAL COMBINED RADIATION DETECTOR/DOSIMETER. Operation Manual

Instruments. for hydroponics & horticulture 2016

SAFETY PERSONAL AC VOLTAGE (50 or 60Hz) PROXIMITY DETECTOR

GENERATOR SELF-TEST VERIFIER (GSV300) INSTALLATION INSTRUCTIONS

RAE Systems Systems. User Presentation. October Protection Through Detection

MetRad1 Handheld Metal/Gamma Detection Unit. Operation Manual. Berkeley Nucleonics Test, Measurement and Nuclear Instrumentation since 1963 BNC

PERSONAL COMBINED RADIATION DETECTOR/DOSIMETER РМ1703МО-1 OPERATION MANUAL

USER GUIDE. Paperless Humidity/Temperature Chart Recorder. Model RH520A 21.2 C 13:

LUDLUM MODEL 35 SERIES DIGITAL SURVEY METER USER S MANUAL

Premium 8 Zone Wireless Alarm Kit

Digital Cooking Thermometer models / 00282

Drayton Digistat +3RF

THA2 TEMPERATURE/ HUMIDITY/ DEWPOINT ALARM WITH LOGGING CAPABILITY. 99 Washington Street Melrose, MA Phone Toll Free

WIRELESS RAIN GAUGE WITH IN/OUT TEMPERATURE INSTRUCTION MANUAL

DESCRIPTION OF KEYPAD (Access module with segments)

User's Guide. Pinless Moisture Meter. Model MO257

Toxic and Explosive Smart Gas Monitor PN / Installation and User Manual

Issue 4 10/10/11. Part Number: 48160

Syringe Pump. User Manual

IMR IX176 Portable Gas Detector User Manual

Color Forecast Station. Table of Contents

NATURAL GAS DETECTOR. Confined Space Monitor. Leak Investigation. Line Purge Testing. Bar Hole Sampling

D3000. Installation & Setup Guide

LUDLUM MODEL 3276 SERIES FRISKER/AREA MONITOR USER S MANUAL. November 2017 Serial Number: and Succeeding Firmware: 49830n30 and Higher

Professional Wireless Rain Guage with 4" LCD

IPhone: 219/

Ranger EXP RADIATION A L E R T

ToxiRAE II. PGM-1100 Series Personal Toxic Gas Monitor. User Manual

LUDLUM MODEL 25 AND 25-1 PERSONAL RADIATION MONITOR USER S MANUAL. October 2014 Serial Number and Succeeding Serial Numbers

TRACERCO T402 and T402HR USER MANUAL

LD200 / RLD400 LD200-G /RLD400-G

Model ST-128M Moisture Detector

3 ZONE WIREFREE BURGLAR ALARM INSTALLATION & OPERATING INSTRUCTIONS

TS400 & TS410. Intruder Alarm Control Panels. Operating Instructions

HOME AUTOMATION, INC. Lumina and Lumina Pro Lighting and Automation System. Quick-Start Installation Guide

Indoor Air Quality Meter Rev. 2.x Meters. The Value Leader TM

SENSIT HXG-2d. SENSIT TECHNOLOGIES 851 Transport Drive Valparaiso, IN Phone: (219) Fax: (219)

LD-5000 REFRIGERANT LEAK DETECTOR

1, 2, 3, and 4-Gas Detector. Technical Reference Guide

Real-Time Remote Monitoring System Utilizing New Electronic Personal Dosimeter

Table of Contents. Product Image 1 Locking/Unlocking the neoair 24 Table of Contents 2 Frost Protection 25 What is a Programmable Room Thermostat?

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012

T82. Instruction Manual. Single Gas Monitor GUARANTEED. FOR LIFE. P/N REV 0 PRINTED ,000 Specifications Subject to Change

Wireless Weather Station with Bluetooth Speaker and Atomic Time & Date

Product Manual SZ1145

TEMPERATURE CONTROLLER (STANDARD MODEL)

Wöhler CM 220. Carbon Monoxide Meter. The Measure of Technology. Contents. 1. Important information Specification... 13

U ser's Guide PC6010

TRACERCO Radiation Monitor

780 Keypad Demonstrator Module

Control Panel-Based Alarm System Installation Programming Operating Keep this manual safe for reference and future maintenance

Quick Start Guide. 1 Charging. Function: Keeps the SoloProtect ID battery fully charged.

Digiplex LED Keypads User s Manual

Wireless Keypads LKP(E)S8M Series

ENMET Corporation. PO Box 979 Ann Arbor, MI RECON. Manual. Manual Part Number MCN-410, 12/03/08

USER GUIDE WIRE-FREE HOME PROTECTION SYSTEM AG100+ CONTENTS

2000 SERIES DIAGNOSTIC ALARM CONTROL SYSTEM

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

Programmable Touchscreen Thermostats. Read all instructions before proceeding. Store this manual for future reference

Transcription:

8.0 Safe-EPD Dosimeter 8.1 Technical data STS Safe-Series Series Field Survey Instruments Instrument Name STS Safe-EPD Dosimeter Description The STS Safe-EPD simulator is a simulated generic Electronic Personal Dosimeter designed to aid the tuition of workers in the nuclear industry in safe practices and in understanding the accumulation of dose over time but without exposure to radiation. The instrument operates using an STS radio frequency detection head which detects the presence of a simulated radiation field with the resultant reading displayed on the LCD Display. The instrument will work simultaneously with the Survey-Safe to provide a complete training experience. Set-able alarm levels, background and chirp rates allow the user to create their own specific training environment. Dimensions (mm) 75H 66W 32D Weight (KG) Construction 0.15KG Moulded Plastic Case Controls Surface mounted pushbuttons Suitable for gloved use Buttons Side - On/Off Front Menu Scroll Pin Hole Setup access Display Type Digital 2 Line 16 character Backlight Yes Battery 2 x AAA 1.5V cells Battery life 10 hrs+ Detector STS radio frequency Detector Audio Output Yes Alarm and chirp rate Alarm Thresholds Yes (1 Rate & 2 Dose Alarm levels) Set in Admin menu LED Red Led Chirp and alarm response Functionality Dose display Rate Display

Background Operating & Storage Temperature Warm up time Available Sources Level set in user menu Operating temp 0 to +30C 10 seconds Safe-MiniSource Storage temp 0C to +40C Additional Information The STS Safe-EPD is not designed to be intrinsically safe and therefore should not be used in hazardous environments. The units are not waterproof and contain delicate and sensitive electronics which may be caused to fail if exposed to moisture. Units should be stored in a clean and dry environment, batteries should be removed if storing for more than 4 weeks. Instrument response will be affected by environmental conditions such as the presence of large reflective surfaces, substantial metal structures and variable wall thicknesses. Factory Default Settings Background: 3: 150 nsv/hr Rate Alarm: 2: 100 usv/hr Chirp Dose: 3: 500 nsv Dose Threshold 1: 2: 500 usv Dose Threshold 2: 2: 10 msv Available settings via Menu Background: 1: 0 nsv/hr, 2: 50 nsv/hr, 3:150 nsv/hr, 4: 500 nsv/hr Rate Alarm: Chirp Dose: 1: 20 usv/hr, 2: 100 usv/hr, 3: 500 usv/hr, 4: 1 msv/hr 1: 0 nsv, 2: 150 nsv, 3: 500 nsv, 4: 1 usv Dose Threshold 1: Dose Threshold 2: 1:100 usv, 2: 500 usv, 3: 1 msv, 4: 5 msv 1: 5 msv, 2: 10 msv, 3: 20 msv, 4: 100 msv

8.2 Operational Controls Scroll through Menu Acknowledge Alarm Menu Option Select Pocket/Belt Clip Battery Access On/ Off Press and hold to turn off To turn the unit on briefly press the on button. To turn the unit off press and hold the on button for 2 seconds. USER accessible Menu: Dose Display: Battery Level Percentage

Rate Alarm Triggered: R Rate Alarm Dose Alarm Triggered: D1 - Dose Alarm D2 - Final Dose Alarm Rate Display: To view the user selectable menu items use the scroll key to move through the Home menu, the Home menu will loop through DOSE, RATE, and Admin Menu screens. ADMINISTRATOR accessible Menu: To enter the Admin menu, press until the screen shows Administrator Menu.

Use a paper clip to activate the Admin Menu through the access hole In the Administration Menu there will be various setting available for selection:

For all the menu items it is possible to select a value from four preset levels. To do this first scroll to the desired menu option and then enter the option by pressing the paper clip. you can then scroll through the various available levels using the. To set the desired level press the paper clip. To exit the options menu, press paper clip at the Exit Menu screen ( if you leave the dosimeter for a period of time(15s) it will revert back to the user menu default).

In this case it is the Rate Alarm level, currently the level is set at 1uSv/Hr To change the level Press the paper clip the display will then display Set Alarm Level: as below To choose from a preset level use the scroll button level, in this case 50uSv/Hr to choose the new desired To save this new value press paper clip- the screen will now update to show Alarm Level: Set : in this case at 50uSv/Hr as below. Here is a breakdown on each of the menu options: Background Rate This determines the dose rate level when there is no source present. This is used to create an environment with a constant dose rate level. Rate Alarm This Alarm determines the dose rate level to which any great increase in dose rate will trigger an audio alarm. This alarm will have a frequency of 1 tone every second. Chirp Dose An audible beep every time set dose is accumulated. Dose Alarm: The first dose alarm. The instrument will alarm once the accumulated dose reaches this threshold.

Final Dose Alarm: The final dose alarm. The instrument will alarm once the accumulated dose reaches this threshold. Sound This determines the initial audio state of the device upon turning on. Network This determines the network type of this instrument. There are two states: Master and Slave. The Master instrument will control the addition of any new instruments into the Radiation simulation network. There must always be one Master instrument switched on to control this network. The Slave units do not have this controlling function, but will join any radiation simulation networks upon turning on. (This radiation network technology is common to all SAFE-Series instruments.) After initial configuration, the devices will remember the set up and use this the next time they are turned on until such time as the set up is manually changed. The Network Status of the instrument is shown upon boot up as shown: Audible Alarms: The Dosimeter has 3 audible alarms. Chirp Dose The Dosimeter will give one single short beep for each incremental amount of dose received ie Set at 50nSv will beep at the first 50, then after a further 50 etc. Rate Alarm The Dosimeter will give an intermittent alarm beep when the rate alarm threshold is exceeded. This Alarm will have an audible intermittent sound until acknowledged by pressing the button. Dose Alarm The Dosimeter will give a continuous broken beep when the dose alarm threshold is exceeded. This Alarm will continue until acknowledged by pressing the button. Final Dose Alarm The Dosimeter will give a continuous beep when the final dose alarm threshold is exceeded. This Alarm will continue until acknowledged by pressing the button.

8.3 Maintenance The Safe-EPD does not contain any user serviceable parts and as such no repair or adjustment should be attempted as this will both invalidate the warranty and lead to potential damage of the circuit. The batteries are accessed through the panel on the side of the instrument. The Safe-EPD uses 2 alkaline AAA cells, professional or long life cells are recommended for best performance. Batteries should be removed when not in use for prolonged periods and partially discharged cells should never be mixed with new cells. ENSURE CELLS ARE CORRECTLY FITTED Observe the polarity markings on the case, the + sign indicates that the cell should be placed with the positive terminal facing the battery door aperture.