Floor cooling system. UNI EN 1264 Certificate.

Similar documents
GHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES

Air treatment units 0932EN October 2017 Dehumidifier unit for radiant systems Flush-mounting installation in false ceilings

GHE Dehumidifiers for radiant cooling systems with heat recovery

Stainless Steel Condensing Boiler Connection Instructions To Additional Heating Devices

CAUTION: ELECTRICAL HAZARD

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

b!klimax Ceiling and Wall Radiant System. Innovative Wellbeing.

CRIMSON & CRIMSON MAX

Regulation EASY CLIMA VERSION 1.6 TECHNICAL MANUAL

Everything you need to know about Radiant Heating but didn t dare ask

b!klimax radiant wall/ceiling system

solar thermic system Solar thermic systems are devices that allow you to capture and store solar energy for later use in various utilization.

SLIDE-IN HEATING COIL INSTALLATION MANUAL BULLETIN

CDS 80. Continuous ventilation without dehumidification can be selected on the CDS 80 control panel.

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

INSTRUCTIONS FOR LAYING OF WOOD FLOORING ON UNDERFLOOR RADIANT HEATING AND COOLING

Dehumidification and ventilation for residential, industrial radiant systems and swimming pools

GHE. Dehumidifiers for radiant cooling systems with heat recovery. Display

SAMPLE STUDY MATERIAL

L8151A Triple Aquastat Relay

L7224A,C; L7248A,C,L Oil Electronic Aquastat Controllers

solar thermic systems

ARGO AR SERIES CONTROLS

BTBa. FLUSHLINE Ventilated chilled beam for cooling, heating and ventilation. BTBa

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

CALEFFI. Modulating temperature regulating unit for heating and cooling with high temperature distribution kit. series /04 GB.

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

LAF 50 / 100 / 150. Condensing dehumidifiers for professional use. Accessories. Design. Approvals LAF

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

TACOTHERM FRESH PETA X (C/CL)

Secondary systems used in Europe.

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

Empty unit Cover Water Total weight 15 kg 8 kg 10 kg 33 kg

DEHUMIDIFIER DT 850 DIRECTIONS FOR INSTALLATION AND USE

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

PRODUCT OVERVIEW. Dehumidifiers

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

HEAT PUMPS AUDAX TOP ErP AND INTEGRATED SYSTEMS

51AKS I S O OWNER S MANUAL

Unit 4: Science and Materials in Construction and the Built Environment. Thermal Comfort

SPECIFICATIONS - NIKE

Product Manual SZ2161. Description The SZ2161 is a microprocessor-based controller designed for water source heat pump plant control applications.

INSTALLATION AND START-UP MANUAL HC BUS CONTROL SYSTEM INSTALLATION MANUAL - FULL VERSION EN

RECUPERA DRY Controlled mechanical ventilation with dehumidification and air treatment GB 01. Air conditioning. Ideas to install

17 Interior Climate Control

HIGH POWER. VICTRIX PRO 2 ErP. High power, wall-hung condensation boiler

QTS SELECTION TECHNICAL BOOKLET

CLIMAV 2.0 Thermoregulation Systems

SHERPA DHW 75. Th e multifunctional air-water split heat pump. COP > 4 DHW 75 C

Installation and operation manual for mixing modules FH-MJB and FH-MJC

TECHNICAL SPECIFICATIONS - CW-80T-TWIN AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way

Product Manual SZ2182

FHE. Dehumidifiers for radiant cooling systems with heat recovery. Display. Versions

FH - GH FH - GH. Dehumidifiers for radiant cooling systems. Versions

Inverter Hot Water Heat Pumps

CAIRfricostar CAU Controller with Remote Control SUPPLEMENT TO OPERATION MANUAL

Line. Floor Heating and Cooling Systems

CONTENTS DE-HUMIDIFICATION IN INDOOR SWIMMING POOLS 2 DESIGN PROPERTIES OF THE INDOOR POOL DE-HUMIDIFYING UNIT 4 FRAME STRUCTURE 6 PANEL STRUCTURE 6

OLIMPIA SPLENDID S INVERTER DC TECHNOLOGY 100% 80% 70% DC INVERTER AC INVERTER NON INVERTER

Heating Mat and Mesh for indoors, modular or customized

VEX100 series Air handling units with cross-flow heat exchanger

Air to water Heat Pump System

H4T R410A. refrigerant

FCX FAN COIL SILENT & EFFICIENT. Floor, ceiling & ducted installation Applicable with VMF management system, Plasmacluster filter option

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

TECHNICAL SPECIFICATIONS - CW-80T AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK

Automatic Burner Controls IFS 110 IM

BRH. Climaveneta Technical Bulletin. Water-cooled liquid chillers ,5-35,1 kw. Versatile High efficiency Maximum silent-running

CWS AIR-CONDITIONERS

Travaglini EQUIPMENT FOR FERMENTING AND AGING OF SALAMI. Travaglini_inglese.indd 6 05/07/

Systems for central heating

TACOTHERM FRESH PETA (C/CL)

SmartRad Planning Manual

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

Basic Principals of Air conditioning By Dr. Esam Mejbil Abed

The skirting board heating system

HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65%

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

TECHNICAL SPECIFICATIONS - CW-80T-TWIN USA & MEXICO

Air magic NTD500 Neutral Temperature Dehumidifier Air magic HRV500 Heat Recovery Ventilation. designed for radiant cooling systems.

INSTITUTE FOR ENVIRONMENTAL RESEARCH & SUSTAINABLE DEVELOPMENT NATIONAL OBSERVATORY OF ATHENS (NOA)

CALEFFI. Thermostatic regulating unit for heating systems. 166 series 01238/17 GB. replaces dp 01238/15 GB. Function

R410A. AIR CONDITIONER DUCT TYPE / ART Series OPERATING MANUAL. REFRIGERANT This Air Conditioner contains and operates with refrigerant R410A.

Components for solar heating systems

Also available with the new i-life R-Slim inverter and radiant panel version. Perfect comfort. Silent operation. Real energy savings

H E A T I N G A L L A R O U N D

Mercury Mixing Kit (Code: ME1053)

Eco-enerdigm was built on the technology of Samyang System Group that was founded in Since 2003, Eco-enerdigm has been testing and researching

Technical documentation Fan coil unit

VICTRIX 50 1 SPECIFICATIONS. Wall mounted condensing boilers

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

Air-Cooling Evaporators

AVIO kw Export 1 FEATURES. Wall-mounted with storage tank

Maincor Underfloor Heating UNDERFLOOR HEATING SYSTEMS. Introduction. Overview. Tel: Web: Why use Underfloor Heating?

Room panel. for ecomax800 R or T regulators. OPERATION AND MAINTENANCE MANUAL ISSUE: 1.3 APPLICABLE TO SOFTWARE: v , v , v08.21.

Q7300H Series 2000 Commercial Thermostat Subbases

SSC-JE STAFF SELECTION COMMISSION MECHANICAL ENGINEERING STUDY MATERIAL REFRIGERATION CYCLES REFRIGERATION CYCLES REFRIGERATION CYCLES

Transcription:

Floor cooling system UNI EN 1264 Certificate www.iip.it

aquatechnik, leading company in the hydro-thermo-sanitary industry, has long been working in the industry of pipe extrusion and moulding of plastic-material fittings. At present, it can boast thousands of projects and successes, with a well-established experience that makes it one of the most significant companies in Europe. Also concerning the industry of floor-panel radiant systems, aquatechnik is characterised by thirty years of experience: the constant use of high-quality components, certified to the UNI EN 1264 standard, as well as the continuous development of new products, allowed the company to supply the market with complete, innovatory and proven floor-panel radiant systems. When temperatures increase, it is extremely important to choose the type of climate control, the search for a perfect combination of system features, such as performance, energy output and obtained comfort. he floor-panel radiant system, besides being considered the best heating system in winter, proves to be an excellent solution for summer cooling, as well. A single, invisible and low-consumption system to control climate in the room all year long; it is healthy and comfortable in its summer version, too. aquatechnik offers its decades-long experience and its competence to supply a winning system, innovatory and high-performance materials, as well as technical support during all steps, from design to installation. IDEAL COMFOR Recent studies have demonstrated that comfort conditions are better when the body can dispose of its own heat according to precise proportions among various heat exchange methods: - 40%-45% by radiation: according to the temperatures of the surrounding surfaces; - 15%-20% by convection: mainly according to the temperature and the speed of the air; - 2%-5% by conduction: according to the temperatures of the surfaces we are physically in contact with; - 30%-35% by evaporation: according to the physical activity and the general surrounding conditions. In summer, the sun warms house structures through the south-facing walls, which can reach 50 C temperatures; the latter transfer heat to the other surfaces by contact and warm them, balancing one to the other. As a consequence, also the air inside the structure will warm up and often exceeds 30 C. When entering a non-cooled room whose walls are warmer than the body temperature, the organism cannot transfer heat, thus causing an increase in the perspiration level, which leads to the subsequent increase in the perceived discomfort. he use of forced-draught air-conditioning systems allows lowering the body temperature by conduction and convection, but air currents and thermal shocks often have contraindications for our health. o obtain an excellent physiological comfort level, you need to transfer heat by radiation, and it is possible only by means of a radiant cooling system. he system with radiant panels allows a homogeneous distribution of temperatures and its advantage is to lower the average temperature of the surfaces that surround the person (floor, walls, ceiling). he concomitant operation of the combined dehumidificators reduces the air humidity level, thus assuring an unequalled wellbeing sensation. Differently from traditional air-conditioning systems that create artificial wellbeing conditions with turbulence effect and high noise level, the radiant cooling system allows obtaining uniform temperatures and correct proportions of heat exchanges between the body and the environment. 1 floor cooling

Floor-panel system Programmed temperature: 25 C - Relative humidity 60% 29 C 29 C Fan coils Programmed temperature: 25 C - Relative humidity 50% 30 C 30 C 26 C 24 C 20 C 26 C 26 C 30 C 24 C 30 C 20 C 28 C he floor-panel heating and cooling system is still the most comfortable climate-control system, which can offer an invaluable habitat and body wellness level. OPERAION he same system with radiant panels that is used in winter for heating purposes, after specific design checks, can cool the rooms in summer, as well. he low-temperature water (on average about +15 C) flows within the same pipes forming the floor-panel circuits that carry hot water in winter; this way, the thermal energy in the air and in the structure will be absorbed and disposed of by the radiant effect of the cooled floor. As for the cooling system with radiant panels, the quantity of relative humidity within the rooms becomes really important. he installation of specific probes in the houses (able to simultaneously detect the relative humidity and the room temperature) allows adjusting the control units to control the switching ON and OFF of the dehumidifiers, besides establishing the lowest fluid delivery temperature as possible inside the pipes, thus assuring the absence of condensation on the floors (temperature limit called dew point ). herefore, the control units will increase the delivery temperature when the percentage of detected relative humidity increases and, vice-versa, they will lower the delivery temperature when the percentage of relative humidity decreaces. aquatechnik offers a wide and complete range of components that allow creating systems and meeting the most varied system needs. Condensation boiler /H probe Room probe Cooling system with Radiant panels Dehumidifier floor cooling 2

HEA-REGULAION SYSEMS Intel and Brain climate control units are the most advanced solutions offered by aquatechnik to manage cooling systems with radiant panels. hey are climate control units designed to assure wellbeing in the rooms. hey streamline energy consumption by controlling the water temperature within the delivery pipes of the system, and are suitable for all climatic regions. In particular, as for the summer cooling function, Intel and Brain control units include delivery probes, humidity and temperature room probes, mixer valves, pumps, servomotors, electrical heads, activation consents for cold water generator and dehumidifiers, with the double function of regulating temperature and room humidity, a combination that assures the best room comfort and wellness. It is possible because aquatechnik s climate control units operate according to a psychometric diagram whose purpose is to identify the so-called saturation line that divides the mist zone from the zone with unsaturated air (where the system includes a mixture of air and water vapour). his way, the control units relate the fluid delivery temperature to the percentage of humidity detected in the rooms by the specific probes. his allows the cooling system to operate with the lowest possible delivery fluid temperature, thus improving the performance of the system and, at the same time, it removes the possibility of condensation formation on the floor (dew point). aquatechnik s climate control units allow simultaneously managing several zones with different temperatures, as well as a pilot zone for humidity in the basic version; however, with the support of the specific expansion module, you can also manage the humidity in several zones and possible system supplements. All zones are provided with working and not-working day programmes (they can be fully customized to make up for any operating need) and, in addition, both programmes are equipped with management by time bands (attenuation) where the control unit will operate to reach a higher room temperature (attenuation degrees can be freely set and are the same in all zones and all time bands). It allows obtaining increased comfort, for example at night, when it is advisable to have slightly higher room temperatures. Furthermore, it allows additional energy saving by making the system operate to obtain a higher room temperature when, for example, the house is empty. As far as every zone is concerned, a single and simple screen (you can customize its name, as well) can be used to monitor the set and detected temperatures, the system efficiency conditions, if it is in full operating conditions or in attenuation mode. aquatechnik climate control units are also provided with a holiday programme, so you can set a starting date and a final date in which the system will always operate in attenuation mode. Intel and Brain are also provided with an interface that allows monitoring the operation of the system, so it is possible to control, in real time, its main operating data, such as for example humidity and maximum room temperature, external temperature, calculated and detected delivery temperatures, as well as the operation of the mixer valve. aquatechnik climate control units are supplied as already programmed concerning the main operating data (attenuation temperature, opening time and operation type of the mixer valve, etc.) and are usually compatible with all climatic zones. Anyway, you can modify all operating values in order to adapt the efficiency of the control units to any need and climatic condition. 3 floor cooling

DEHUMIDIFICAION SYSEMS For the correct operation of the radiant system in the cooling mode, it is absolutely necessary to adjust the system for the dehumidification function. Dehumidifiers have the function of removing the humidity from the environment: they suck the air charged with humidity within the premises. After that, the air passes through the pre-cooling battery, where the air is cooled at a temperature that is close to saturation. hen, the pre-treated air is conveyed to the evaporator, which further lowers its temperature beyond the dew point, where the water vapour condenses and the produced water will be drained. Now, the dehumidified air with a very low temperature is introduced into the condenser, which increases its temperature. After that, the air passes through the post-cooling battery (supplied with the same water conveyed into the pipes of the system with radiant panels), whose function is to adjust the air at a neutral temperature (similar to the initially sucked air) besides disposing of the heat produced by the condenser and the connected compressor. aquatechnik offers a wide range of dehumidifiers to better meet all needs, with different dehumidification ranges. In addition, a series is available having a patented integration system that can introduce cold air into the premises: it is useful in particularly adverse rooms (for example, attic or rooms exposed to the sun with large glass surfaces). echnical features DRY 200 P DRY 400 P DRY 400 PI DRY 400 S DRY 400 SI Input voltage 230 V - 50 Hz 230 V - 50 Hz 230 V - 50 Hz 230 V - 50 Hz 230 V - 50 Hz Average rated power demand (at 20 C, 60% R.H.) 250 W 390 W 390 W 400 W 400 W Maximum power demand (at 32 C, 95% R.H.) 320 W 450 W 450 W 460 W 460 W Max. current demand (at 32 C, 95% R.H.) F.L.A. 1.9 A 3.0 A 3.0 A 3.0 A 3.0 A Breakaway starting current F.L.A. 14.0 A 20.0 A 20.0 A 20.0 A 20.0 A Air flow (with clean filter) 260 mc/h 320 mc/h 320 mc/h 320 mc/h 320 mc/h Sound pressure level SPL (at 3m in free field) 34 db(a) 34 db(a) 34 db(a) 38 db(a) 38 db(a) Coolant R134a 190 g 360 g 360 g 360 g 450 g Standard defrosting control electrical electrical electrical electrical electrical Operating range (temperature) 8-32 C 10-32 C 10-32 C 10-32 C 10-32 C Operating range (relative humidity) 40-98 % 45-98 % 45-98 % 45-98 % 45-98 % Rated condensation capacity (30 C - 80% R.H.) 14 l/g 34 l/g 34 l/g 34 l/g 34 l/g Weight with formwork excluding the grating 26 Kg 36 Kg 36 Kg 34 Kg 39 Kg Cooling water flow-rate (input temp. 15 C) 80 l/h 180 l/h 260 l/h 180 l/h 260 l/h Cooling water pressure drop 2,3 kpa 12,0 kpa 25,0 kpa 12,0 kpa 25,0 kpa Cooling funct. capacity (room t. 25 C-65%, water 16 C/18 C) - - 1600 W - 1600 W Cooling funct. sensitive capacity (room t. 25 C-65%, water 16 C/18 C) - - 960 W - 960 W floor cooling 4

CONROL UNIS (art. 98002-98010-98020) Designed and manufactured to manage radiant climate control systems. - MONOCLIMA (single-climate): single-zone, programmable control unit - INEL: programmable control unit up to 7 zones - BRAIN: programmable control unit up to 24 zones /M AND ROOM S (art. 98030-98032) hey are available in temperature and /H versions to detect room-humidity temperatures. Reduced overall dimensions and modern design to favour the relevant integration into the furniture. EXERNAL (art. 98036) It was designed and manufactured to detect the external temperature. (art. 98034) Immersion probe to detect the temperature of the delivery water. EXPANSION MODULE (art. 98040) It allows installing several /H probes and the subsequent detection of the humidity level in different zones. DRY P DEHUMIDIFIERS (art. 98198-98200-98206) For wall-mount applications. hey were designed and manufactured to streamline the humidity level and to prevent the condensation effect in floor-mounted radiant systems in the cooling function; they are provided with a post-cooling battery. Dehumidification capacity: 14 l/24h for the P200 model ; 34 l/24h for the P400 model. he latter is also available with a 1600W supplement. hey are arranged for vertical underpin installation within the areas identified by the designed. DRY S DEHUMIDIFIERS (art. 98245-98250) For ceiling-mount applications. hey were designed and manufactured to streamline the humidity level and to prevent the condensation effect in floor-panel radiant systems in the cooling function; they are provided with double battery (pre- and post-cooling). Dehumidification capacity: 34 l/24h. hey are also available with a 1600W supplement. hey are arranged for horizontal underwall installation and in compartments or lowered areas within the ceiling, within the zones identified by the thermohydraulic designer. REMOE INERFACE (art. 98280-98285) It is a device that allows managing and displaying the data concerning the climate control units; it has a modern and up-to-date design. 5 floor cooling NOE: for further information, see the technical data sheets about the products in the web site: www.aquatechnik.it

PRACICAL RECOMMENDAIONS ESING OF HE SYSEM - It is extremely important to test the system before casting the screed and leave it under pressure during the relevant formation. - est the system at a recommended pressure of 10 bar, and restore the pressure from time to time until it has stabilised. - During testing operations, it is advisable to perform some pressure charging and descharging cycles in the system before stabilising the pressure at the pre-established value. he aforesaid cycles allow identifying possible weaknesses in the pipes and in gasket seals between manifold couplings, etc. - In case of freezing hazard, use the specific antifreeze solutions after checking their compatibility with the pipes, or completely drain the system, in case of water testing, after casting the screed. - If there is no freezing hazard and you want to prepare the system to be switched ON, fill it by means of the specific charging/descharging units that are installed in the manifolds, as it is described in the following chapter. - he absence of leakages and the testing pressure must be specified in a testing report. SWICHING ON AND BALANCING OF HE SYSEM - Load the system by using the specific charging/descharging units installed in the manifolds. Fill loop by loop, and drain the air from a rubber pipe that is connected to the charging/descharging unit and use manual and automatic drain valves. he operation must be carried out by starting to fill, with all valves and holders being closed, except for the ones for a loop. After draining the first loop, act in the same way for the other loops and close valve and holders of the completed loops. he aforesaid procedure assures a correct tharging of the system and, as a consequence, a better output also preventing the malfunction of the circulating unit. - While filling the system it is important to drain all the air that is present. System charging and venting operations are carried out as follows: 1) close all holders and all valves in delivery and return manifolds. 2) close the shut-off valves installed in the supply lines of delivery and return manifolds. 3) connect a transparent rubber pipe to the draining cock of the return manifold (on the top). 4) fill the water through the delivery manifold (low) by means of a pipe connected with the charging/ descharging cock or through the Ø 1 opening of the shut-off valve. 5) open the valve and the holder in the first circuit loading the water until fully removing the air; check the continuous exit of water by using the transparent rubber draining pipe previously connected with the return manifold. 6) close both the valve and the holder in the previously loaded circuit. 7) repeat the last two operations for all circuits. - Before switching ON the system, check that the perimeter insulating strip was cut flush with the final floor, assuring that the screed freely operates (expands) against the vertical structures. - Wait at least three screed-drying weeks before activating the system. - Switch ON the system with an initial delivery temperature of 25 C to be kept for 3 days. After that, increase it until reaching the maximum design temperature (see the drawing), which has to be kept for at least 4 days. - he system start-up process must be documented. - In case of quick drying, self-levelling or synthetic casting screeds, activate the system after a period that complies with the specifications established by the supplier of the screed. - While starting up the system, adjust the boiler thermostat at 50 C. he aforesaid precaution prevents water from circulating at a too high temperature within the panel system in case of adjustment malfunctions. - Calibrate the circuits of the system by adjusting manifold holders and position the relevant opening according to design tables (see the drawing). - As far as the boiler is concerned, you have always to provide for a safety probe to be installed in the delivery side of the panel system, which is independent from the control unit, and directly connected with the heat generator that will switch it OFF in case of overtemperatures. DESIGN ACIVIY - o prevent physiological discomfort conditions, the surface temperature of the floor must be lower than the values established by the reference standards (UNI/CEN 130 and UNI EN 1264-2), max. 29 C in residential living areas, max. 35 C in marginal areas with the limit of 1 m depth from external walls. he 35 C max. temperature can also be reached in the so-called transit and/or passage areas (ex. access floor cooling 6

areas and corridors) and in toilets. - o prevent useless heat accumulations and to reduce the already remarkable thermal inertia of this type of systems, during the design step, keep the value of the power supplied by the panel lower than the value provided for in reference standards (UNI/CEN 130 and UNI EN 1264), that is, max. 100 W/m 2. - It is preferable to use modulating-type thermoregulations, that is, capable of adapting the system to the external climatic conditions. Indeed, differently from thermostatic thermoregulations, which are also called fixed-point because they always maintain the same water temperature within the system, the thermoregulations with climatic regulator assure the reduction of useless heat accumulations in the screed with the subsequent reduction of the thermal inertia in the same system. In addition, selecting modulating thermoregulation assures considerable energy saving when managing the system SYSEM MANAGEMEN - During the operating period, do not switch OFF the system and reduce system operation slowdowns as much as possible; in that case, do not exceed maximum 2 or 3 degrees of difference (Δ) between comfort and attenuation temperatures. - It is advisable to manage the system with modulating thermoregulations. 7 floor cooling

EXAMPLES OF GRAPHIC DIAGRAMS SANDARD DIAGRAM FOR VALU-ECHNIK FLOOR-PANEL HEAING AND COOLING SYSEM WIH RADIAN PANELS, HIGH AND LOW EMPERAURE SYSEM, MULI-ZONE WIH UM3-YPE MIXING UNI AND ELECROHERMAL HEADS EJECION SUPPLY REMOE CONROL CONDENSAION BOILER EXERNAL GAS LINE REFRIGERAOR UNI O HE CONROL UNI EMPERAURE O HE CONROL UNI / VALU-DRY DEHUMIDIFIER O HE CONROL UNI O HE CONROL UNI /H HUMIDIY EMP. O HE CONROL UNI FAN-COIL CIRCUI FAN-COIL CIRCUI O HE CONROL UNI VALURAPID MANIFOLD VALURAPID MANIFOLD VALU-DRY DEHUMIDIFIER CIRCCIRCUI OF HE RADIAN PANEL CIRCCIRCUI OF HE RADIAN PANEL CONROL UNI (INEL) EXERNAL SAFEY HERMOSA CALIBRAED A 50 C S DELIVERY S DIFFERENIAL BYPASS MIXER VALVE M floor cooling 8

SANDARD DIAGRAM FOR VALU-ECHNIK FLOOR-PANEL HEAING AND COOLING SYSEM WIH RADIAN PANELS, HIGH AND LOW EMPERAURE SYSEM WIH UM3-YPE MIXING UNI, ELECROHERMAL HEADS AND SOLAR SYSEM S1 SOLAR MANIFOLDS EJECION SUPPLY BOILER HEAING ONLY SOLAR CONROL UNI REMOE CONROL S1 > S2 = R1 S3 < 40 = R2 DOMESIC HO WAER O HE CONROL UNI R1 GAS LINE S3 D R1 O HE CONROL UNI DIVERER VALVE S2 ACCUMULAION OF SANIARY WAER DOMESIC COLD WAER REFRIGERAOR VALUDRY DEHUMIDIFIER O HE CONROL UNI OWEL WARMER A O HE CONROL UNI /H O HE CONROL UNI VALURAPID MANIFOLD HUMIDIY EMP. UM3 MIXING UNI SAFEY HERMOSA CALIBRAED A 50 S DIFFERENIAL BYPASS DELIVERY S MIXER VALVE M MONO-CLIMAE CONROL UNI EXERNAL NOE: CONROL OF DELIVERY EMPERAURE BY MEANS OF HE UM3 MIXING UNI WIH CLIMAIC REGULAOR AND CONROL UNI EQUIPPED WIH EXERNAL CONROL OF ROOM EMPERAURE BY MEANS OF WO-WAY ZONE VALVE CONROLLED BY HE CONROL UNI CONROL OF HE DEHUMIDIFIERS CONROLLED BY HE CONROL UNI 9 floor cooling

M SANDARD DIAGRAM FOR FLOOR-PANEL VALU-ECHNIK HEAING AND COOLING SYSEM WIH RADIAN PANELS, SYSEM WIH HEA PUMP AND SOLAR MANIFOLDS FOR HIGH AND LOW EMPERAURE WIH COOLING CONROL SOLAR MANIFOLDS SOLAR REURN UNI O WAER UILIIES AIR/WAER HEA PUMP SPIRAL HEA EXCHANGER DOMESIC COLD WAER ECHNICAL WAER OWEL WARMER O HE CONROL UNI O HE CONROL UNI O HE CONROL UNI O HE CONROL UNI OWEL WARMER VALURAPID MANIFOLD VALURAPID MANIFOLD DEUMIDIFICAORE VALU-DRY VALUDRY DEHUMIDIFIER EMPERAURE EMP./HUMIDIY O HE CONROL UNI / O HE CONROL UNI /H CIRCUI OF RADIAN PANEL CONROL UNI EXERNAL CIRCUI OF RADIAN PANEL FAN-COIL CIRCUI floor cooling 10

SANDARD DIAGRAM FOR FLOOR-PANEL VALU-ECHNIK HEAING AND COOLING SYSEM WIH RADIAN PANELS, HIGH AND LOW EMPERAURE SYSEM WIH COOLING CONROL EJECION SUPPLY REMOE CONROL CONDENSAION BOILER EXERNAL GAS LINE REFRIGERAOR UNI O HE CONROL UNI EMPERAURE / O HE CONROL UNI VALU-DRY DEHUMIDIFIER O HE CONROL UNI O HE CONROL UNI /H HUMIDIY/EMP. O HE CONROL UNI FAN-COIL CIRCUI FAN-COIL CIRCUI O HE CONROL UNI VALURAPID MANIFOLD VALURAPID MANIFOLD VALU-DRY DEHUMIDIFIER CIRCUI OF RADIAN PANEL CIRCUI OF RADIAN PANEL CONROL UNI (INEL) EXERNAL SAFEY HERMOSA CALIBRAED A 50 S DELIVERY S DIFFERENIAL BYPASS MIXER VALVE M 11 floor cooling

NOES floor cooling 12

REFERENCES 13 floor cooling

floor cooling 14

Magicgraph - Aprile 2013 - vers.00 ADMINISRAIVE SEA - PRODUCION - WAREHOUSE 20020 Magnago (MI) - IALY - Via P.F. Calvi, 40 Phone 0039 (0)331 307015 - Fax 0039 (0)331 306923 DEMONSRAIVE/RAINING CENER IN BUSO ARSIZIO AND ECHNICAL DEP. 21052 Busto Arsizio (VA) - IALY - Via Bonsignora, 53 E-mail: aquatechnikexp@aquatechnik.it www.aquatechnik.it