A System That Utilizes the LD-2000 or LD-3000 Mechanical Line Leak Detector to Perform 3 10 PSI (catastrophic) Line Tests

Similar documents
INSTALLATION AND OPERATION MANUAL ISM-4081 INTEGRATED SHUTDOWN MODULE

AL600ULADA. NAC Power Extender. Installation Guide

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

AL800ULADA. NAC Power Extender. Installation Guide

Gas Safety Products. Installation, operating and maintenance 11/18/2015. Merlin 1000S+ Gas Utility & Electrical Isolation Controller

Installation, Operating and Maintenance Manual

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

Gas Safety Products. Installation, operating and maintenance. Merlin 1000S+i Gas & Electric Utility Controller. Rev: 03 Date:

Evaluation of the Red Jacket Fx1, Fx2, Fx1V and Fx2V Line Leak Detectors For Hourly Monitoring on Rigid Pipelines. Final Report

PLC-5000 FULL SHUT-DOWN SYSTEM INSTALLATION AND OPERATION MANUAL

Gas Safety Products. Installation, operating and maintenance. Merlin 1000VW+ Gas Interlock, Gas Proving, Electric & Water Isolation System

PRYCO, INC. FUEL CONTROL

Specification/ Data Sheet

Evaluation of the Incon TS-LLD Line Leak Detection System

Ammonia Detection System Codes and Design Specifications

FDF Foam Pump Controllers Features

24V PCU CORE FIRE PROTECTION INSTALLATION SUMMARY

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

FEC400 Series. Installation Manual

XC10 Extinguishing control panels

PURGE/PRESSURIZATION SYSTEM

Model 7700 Pump Director Valve and Pump Motor Interface Controller

24V PCU CORE FIRE PROTECTION INSTALLATION SUMMARY

Manual No: Revision: G. Sensor Products. Application Guide

TECHNICAL DATA OBSOLETE

Fire Control/Communicator

Conventional Releasing Control Panel

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

Electric Release Panel Wiring Tips

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

Isolation Relay: If Needed. # 9. NO relay for TT To Thermostat NO relay. MZ308 Exquisite Heat Controller

QUICK SHIP Products. Available for Same/Next Day Shipment at NO ADDITIONAL CHARGE!

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH SHP-PRO CONTROL PANEL

Gas Safety Products. Installation, operating and maintenance. Merlin 1500S Gas Interlock System. American Gas Safety LLC 1 05/10/2016

Frequently Asked Questions

RED1. Technical Support And Installation Manual. Models ST, E1, E2, E3, E4, and 420. Approved

Single Doors FIREGUARD Series Use one Master Unit each door or one 2409 Support unit each door. Pairs of Doors

Commercial and Light Industrial Fire Alarm Control Panel

WaterFurnace FX10 Application Guide Reversible Chiller

EVLA Memorandum 107 Failure Pathology of EVLA WIDAR Correlator Support Systems October 18 th, 2006 Bob Broilo, Brent Carlson

Model 3300 Technical Support and Installation Manual

D2071A. Operation & Installation Guide Fire Alarm Control Panel

GasScanner 8C. Eight Channel Monitor. Operator s Manual. MINT-0281-XX Rev. A 01/29/08

Gas Safety Products. Installation, operating and maintenance. Merlin 1500S Gas Interlock System. Rev: 03 Date:

MODEL MW200 MODEL MW600 AIR DRYER

LS500 Auto Learn Line Leak Detection

Wiring Instructions for the 2900 Series FIREGUARD Combination Door Closer-Holder and Releasing Device with Integral Smoke Detector

Alternative Fuel Fueling Stations

TOTAL SOLUTIONS. Liquid Level Control Product Guide. MATELEC AUSTRALIA innovative by design

Beacon 800 Gas Monitor Operator s Manual

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH CHEETAH Xi 50 CONTROL PANEL

RELAY BASES & COVERS

RAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) General Description.

Booster Power Supply Manual

21-light Remote Annunciator. Owner s Manual

PL140 Sump Liquid Sensor-Controller Kit With Local or Remote Notification

MODEL B2 INSTALLATION MANUAL

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

Rack Mount Series Installation Guide

RAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) General Description

CHECKFIRE 210 Detection and Actuation System

CONTACTORS FOR AEROSPACE GROW SMARTER AND MORE CAPABLE

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

MINERVA MX. 800 Series Ancillary Equipment

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

SYSTEM DESIGN REQUIREMENTS

Electronic Fuel Management Systems

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

Model A1600 Series Annunciator

Product Data Sheet. Merlin GDP2. Gas Safety Products. Merlin GDP2. Installation, operating and maintenance 23/08/2016. S&S Northern Ltd 1

Type 8001 PRIME MOVER CONTROLS INC. ALARM ANNUNCIATOR TYPE8001 FEATURES SB 8001B

10-175UL INSTALLATION. Power Supply UL. Access Control Power Supply/Charger. Installation and Specifications Manual

Pneumatic Heat Press. Revision: 3 Operators Manual

Automatic Tank Gauging and Line Leak Detection System Bid Specification TS-550evo Fuel Management System

RELEASE DEVICE CONTROLS

Linear Heat Detection for Coal Conveyors. Application Guide

NU2 Smart Power Supply (SPS) Manual

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

MODEL EUR -5A AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL

Installation Guide for models:

30.45 Electric Release PDRP-2001

Application Note. Using XPoint Wireless Devices with Emergency Lighting. 1 of 16

Installation and Operation of AST Equipment. Presenter: Steve Allwein Northeast Regional Sales Manager Morrison Bros. Co.

Installation Guide for models:

SP-1000X. Panic Device Power Controller Installation Guide. Rev

LEAKSTOPPER RANGE Multizone water leak detection systems

TLS-300 UST Monitoring and Leak Detection System

ERS-3600B. PERS-3600B Personal Emergency Reporting System

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

Ammonia Leak Detector Manual

DIGITAL LIGHT CONTROLLER

MR3CCUHV Temperature/Defrost Control

FireNET Plus Wiring Instructions

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

WaterLeakStop Manual. Detection and Management of Water Leaks WLS-1

SECTION SANITARY SEWAGE PUMP STATIONS

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

Transcription:

Overview of the

A System That Utilizes the LD-2000 or LD-3000 Mechanical Line Leak Detector to Perform 3 GPH @ 10 PSI (catastrophic) Line Tests

Meet EPA Hourly Test Requirement by Performing Line Tests In-Between Dispensing Activity

Integrates Line Leak Alarms to Offsite Reporting Significantly Reduces Thermal Contraction Slow Flow

How Mechanical Line Leak Detectors Function Mechanical line leak detectors (MLLD) are line pressure monitors MLLD checks for pressure drop in line when the pump is off

The ISM Switch detects falling line pressure and initiates a line test to look for line leaks or overcome thermal contraction

Falling line pressure, due to thermal contraction or line leak Leak detector responds to line pressure change ISM-4103 switch opens to notify ISM-4080 to start line repressurization cycle

Line has been tested and repressurized Switch has been closed and ISM-4080 notified ISM-4080 shuts off the submersible and monitors line pressure

Overview of ISM-4080 During authorization or during inactive (monitoring) periods, provide submersible shut-down in the event of a catastrophic line leak Submersible shut-down is the only option for a catastrophic line leak, no alarm only option

Overview Provide Hourly Testing Eliminate thermal induced false alarms Test and repressurize the line during periods of thermal contraction

Overview Monitor single point sump sensors: ISM-4080: Submersible shut-down if the sump sensor is activated ISM-4081: Alarm only option at sump sensor activation

Overview Provide a means for an uninterrupted tank test without submersible restarts if needed Allows authorized dispensing during this time

Overview Provide a means to report line test failures and sump alarms to site monitoring equipment

Overview Utilize existing mechanical line leak detectors - 99 series (since 2/98) - LD-2000 & LD-3000 The ISM-4080 can utilize existing sump sensor wiring to reduce installation costs

Overview Where multiple submersibles are piped into a single delivery line, ISM-4080 & 4081 Modules may be wired to stage the submersibles, ensuring (EPA) 3 GPH line leak detection

Three Components of ISM-4080 + ISM-4081 1. A certified mechanical line leak detector: VMI LD-2000 or LD-3000 and

Three Components of ISM-4080 + ISM-4081 2. A Piston Switch to determine: The position (status) of the mechanical line leak detector which identifies falling line pressure and

Three Components of ISM-4080 & ISM-4081 3. A Microprocessor: Receives line pressure/leak detector status information from the piston switch May receive sump sensor status Controls power to the turbine Alarm outputs Staged Turbine Control

Continuous Line Leak Monitoring Automatic Line Test Line pressure is monitored through a switch attached to the mechanical leak detector If line pressure falls below 12 PSI, a wait time is established

Continuous Line Leak Monitoring Automatic Line Test Wait time is sufficient for the leak detector to reset if there is a 2 GPH @ 10 PSI line leak (or less)

How Do We Know The Leak Detector Is Reset? Each line is unique To ensure the leak detector is reset, we have the installer measure the bleed-back (line resiliency)

Reset, Continued Bleed-back gives us the unique volume each (tight) line holds before a leak detector is reset Wait times are based upon this volume (set at install)

Continuous Line Leak Monitoring Automatic Line Test After the reset period has elapsed, a line test is run. If the line passes the catastrophic test, the ISM resets and monitors the line for pressure loss again If the line fails a monitor test, the submersible is shut-down and an alarm is activated

After an authorization, the ISM-4080 allows the leak detector up to 15 seconds to repressurize the line and open Shut-down and alarm if the leak detector does not open

A leak test of the mechanical line leak detector to detect a catastrophic line leak, stay in slow-flow and for the ISM to shut-down the submersible during both an authorization and during an Automatic (Monitor) Line Test is required for post-installation and Annual Equipment Testing

No New Wires To The Submersible Pump Sump ISM-4080 monitors a normally closed Piston Switch on an intrinsically safe circuit The Piston Switch may be installed in parallel with an existing N/C sump sensor that does not have a resister inline

No New Wires, Continued When installed in this manner, the ISM-4080 is able to discriminate between the sump sensor and the piston switch

Ready Relay When the Leak Detector Moves Open, the Piston Switch Opens, the ISM Closes the Ready Relay

Ready Relay With the Line Passed, this Relay Can Safely Start Additional Submersibles May Be Used to Open Solenoid Valves That Have Isolated Above-ground Portions of the Line While the Under-ground Portion was Tested

Ready Relay May Be Used to Open Solenoid Valves Closed During Line Testing Allow Fuel to Loading Rack Allow Filling of Day Tanks Allow Fuel onto Boat Dock Allow Fuel into Polishers

No Interference With Automatic Tank Testing Three Options

Option 1 The Key Pad allows the installer to enter the disable hours for tank testing The ISM stops repressurization every day at the same time Battery backup to keep timer settings and run time

Option 2 The ISM-4080 will stop repressurization on a signal from the site Tank Test (Monitoring) Equipment AC Signal DC Signal

Option 3 Set the run time for the submersible to 0 seconds

Alarm Output Alarm output is a contact closure Report through site monitoring auxiliary sensor input

Alarm Output, Continued Report through stand-alone light, horn, etc. 115vac to 250vac, up to 8 amps Up to 30 vdc, up to 5 amps

Authorization Signal Authorization signal may be between 60 to 240V Contactor control through the ISM

Operation of System Certified Mechanical Line Leak Detectors Independent testing at Ken Wilcox Associates confirms VMI leak detectors operate as originally certified with Piston Switch installed

Operation of System Independent testing confirms VMI leak detectors operate as originally certified with Computer Processor initiated leak tests

Operation of System Independent testing confirms the submersible pump is shut-down when the mechanical line leak detector finds a catastrophic line leak of 3 GPH @ 10 PSI

Operation of System Independent testing confirms Computer Processor recognizes sump sensor activation and shuts submersible pump off

Fuel Compatibility: Ethanol, Methanol, Biodiesel, & Aviation Fuels All VMI mechanical line leak detectors are delivered from the factory for use in up to 100% concentrations of the above fuels For concentrations over 20% Alcohol, concentrations over 5% Biodiesel, or any Aviation Fuel use Stainless Steel Vent Kit

Ethanol Issues Ethanol wants to off-gas or return to a vapor state Vapor pockets cause slow flow or missed detection in electronic line leak monitors Only by keeping the line pressure above 5 PSI can this be prevented

Following are two slides taken at an E-85 site The ISM-4080 installed at this and many other sites has been effective at reducing false alarms Credited with saving the submersible at this site due to low fuel

Meets All Regulatory Codes Quality Value Submersible shut down due to a catastrophic leak Customer Satisfaction Service Alarm notification Defeat thermal contraction Allow tank quiet time for testing