T-Class AC and HP Units Up to SEER and 9.0 HSPF. Commercial Air Conditioners and Heat Pumps. True performance and rugged durability

Similar documents
True performance and rugged durability Commercial Air Conditioners and Heat Pumps TSA/TPA Models. Up to 15.0 SEER, and 9.0 HSPF

True performance and rugged durability. Commercial Air Conditioners and Heat Pumps TSA/TPA Models. Up to 16.2 SEER

T-CLASS. Commercial Air Conditioners and Heat Pumps TSA/TPA Models UP TO 16.0 SEER AND 9.7 HSPF. Performance and rugged durability

The most energy-efficient commercial split system* Commercial Air Conditioners and Heat Pumps SSB/SPB Models

AC, HP and Air Handler Units Up to 20 Tons. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

50Hz AC, HP and Air Handler Units Up to 70 kw. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

T-CLASS Commercial Split Systems Up to 20-Ton TSA/TPA Models

Performance and rugged durability. Commercial Split Systems Up to 20-Ton TSA/TPA Models

Air Handlers and Indoor Coils Up to 20 Tons. CB* and C* Models. True performance and rugged durability

Performance and Reliability. CB*, C* and TA* Models

14HPX MERIT SERIES R 410A H E A T P U M P O U T D O O R U N I T S

T-SERIES COMMERCIAL SPLIT SYSTEMS 6- TO 20-TON ELP/ELS MODELS UP TO 12.0 EER

Lennox Mini-Split Systems Year-Round Comfort and Performance

13HPD MERIT SERIES R 22 H E A T P U M P O U T D O O R U N I T S

T S A 048 S 4 N 4 1 T

The XP21 raises the bar for efficiency and comfort.

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

XC17. DAVE LENNOX SIGNATURE COLLECTION R-410A - SilentComfort Technology. SEER up to to 5 Tons Cooling Capacity - 21,800 to 59,000 Btuh

Landmark. Commercial Packaged Rooftop Units 2- to 25-Ton KG/KC/KH Models. Up to 13.0 SEER, 14.0 IEER. Performance Marked by Flexibility

2 shp 13 lc 1 36 t - 1 a

14 AC x

Come home to perfectly quiet and efficient comfort.

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

The XC21 delivers the ultimate in comfort.

3- to 24-Ton Models. Commercial Packaged Rooftop Units. The most energy-efficient rooftop unit in the industry *

The XC17 is an efficiency expert.

XC16. ELITE SERIES R 410A Two Stage Compressor SilentComfort Technology A I R C O N D I T I O N E R S

Commercial Packaged Rooftop Units 3- to 50-Ton LC/LG Models. Up to 17.0 SEER, Up to 12.8 EER

Xc21 air conditioner up to seer Xc21

T CLASS SPLIT SYSTEM UNITS Standard Efficiency R HZ Bulletin No March 2009 Supersedes April 2008

ELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS

L E N N O X MINI-SPLIT SYSTEMS THE SOLUTION THAT WORKS WHERE OTHERS WON T.

4HP15L PRODUCT SPECIFICATIONS HIGH EFFICIENCY SPLIT HEAT PUMP SYSTEM UP TO 15 SEER & 9.0 HSPF COILS COMPONENTS COMPRESSOR WARRANTY CABINET DESIGN

The XP17 provides comfort without comparison.

LENNOX MINI-VRF SYSTEMS. CONNECTING TECHNOLOGY WITH EXPERTISE.

T CLASS SPLIT SYSTEM UNITS Standard Efficiency - R-410A - 60 HZ

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

Up to 16.1 SEER, Up to 14.3 EER and Up to 15.4 IEER

DRY CHARGE UNITS. 1.5 to 5 Tons. HEAT PUMP OUTDOOR UNITS lps13dc PRODUCT SPECIFICATIONS L P S 13 DC MODEL NUMBER IDENTIFICATION

T CLASS SPLIT SYSTEM UNITS Standard Efficiency R HZ Bulletin No March 2009 Supersedes August 2008

PROVIDING EXTRA-HIGH EFFICIENCY AND WORRY-FREE PERFORMANCE

2018 LIGHT COMMERCIAL ROOFTOP UNITS. Industry-leading efficiency and innovation to meet your needs

complete comfort Heat Pumps

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 18,000 to 60,000 Btuh AIR CONDITIONERS ML14XC1 PRODUCT SPECIFICATIONS

MERIT Series R-410A. SEER up to HSPF up to to 5 Tons Cooling Capacity - 18,000 to 61,000 Btuh Heating Capacity - 17,500 to 58,500 Btuh

PROVIDING HIGH EFFICIENCY AND WORRY-FREE PERFORMANCE

Specially Designed. SilentComfort Fan Guard. Visit us at For the latest technical information,

ELITE Series R-410A - Two-Stage Compressor

incomparably cool XC21 The most quiet and efficient central air conditioner you can buy*

complete comfort Heat Pumps

DUAL ZONE CONTROL PANEL Zone Control For Residential Heating/Cooling Systems

complete comfort Heat Pumps

seer 4HP16LT Split System Enhanced Heat Pump Features and Benefits WARRANTY

T P A 048 S 4 N 4 1 T

complete comfort Heat Pumps

Commercial Packaged Rooftop Units 3- to 50-Ton LC/LG Models UP TO 18.0 SEER, 12.8 EER AND 15.5 IEER

XP21 The most quiet and efficient heat pump you can buy*

Infinity 16 Heat Pump with Puron Refrigerant

DAVE LENNOX SIGNATURE COLLECTION WITH SILENTCOMFORT TECHNOLOGY

A heat pump that redefines comfort and efficiency.

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

072, 090, 120, 180 & 240 MODELS C SERIES CONDENSING UNITS P SERIES HEAT PUMPS

DT5BD Series High Efficiency Heat Pumps 13+ SEER Residential System Ton Capacity

XC21. XC21 Air Conditioner Up to 20.5 SEER. Home Comfort Systems. The most quiet and efficient central air conditioner you can buy*

Air Conditioner with Puron Refrigerant MODEL 126B

Infinity 19 Heat Pump with Puron Refrigerant

Home Comfort Systems. g60v. The quietest furnace in its class*

SSB. S CLASS SPLIT SYSTEM R 410A Two Stage Compressor 60 HZ A I R C O N D I T I O N E R S

cool and comfortable Air Conditioners

Commercial Packaged Rooftop Units 3- to 50-Ton LC/LG Models. Up to 18.0 SEER, Up to 12.8 EER and 14.5 IEER

16 SEER Split System Enhanced Heat Pump 4SHP16LT. Features and Benefits WARRANTY

T P A 120 S 4 S N 1 Y

Cooling & Heating Products Residential and Commercial

An air conditioner that redefines comfort and efficiency.

True performance and rugged durability. TU, LF and LD Models

Infinity 21 Air Conditioner with Puron Refrigerant

complete comfort Heat Pumps

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

SPLIT SYSTEM AIR CONDITIONERS, HEAT PUMPS AND PACKAGED SYSTEM PRODUCTS Built Exclusively for Manufactured Housing

Infinity 20. Heat Pump with Greenspeed Intelligence. Variable-Speed, Ultra High-Efficiency Heat Pump with up to 20.0 SEER and 13.

Series. Heat Pumps. Two-Stage, Extra-Efficient Heat Pumps with up to 19.0 SEER and up to 9.5 HSPF. Infinity

ELITE Series Variable Capacity

RSG16**S1M. Split System Air Conditioner 16 SEER

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Preferred 96t Gas Furnace with Perfect Heat Technology

Air Conditioner with Puron MODEL 186B

Visit us at For the latest technical information,

Infinity 19 Heat Pump with Puron Refrigerant

TECHNICAL SPECIFICATIONS

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

AIR HANDLERS R-410A, Variable-Speed TOUGH. SMART.

ELITE Series Variable Capacity

Two-Stage Heat Pump with Puron

16.0. High-Efficiency Heat Pump Designed with Your Comfort in Mind. Performance Series Heat Pumps with Puron Refrigerant

AND WORRY-FREE PERFORMANCE

AND WORRY-FREE PERFORMANCE

The First Family of Indoor Weather

Transcription:

T-Class AC and HP Units Up to 15.00 SEER and 9.0 HSPF T-Class Commercial Air Conditioners and Heat Pumps TSA/TPA Models True performance and rugged durability

Control operational costs with reliable, energy-efficient split systems T-Class split systems at a glance: High-efficiency units for reduced energy usage Easy installation and maintenance A variety of sizes for increased application flexibility Excellent construction, reliability and warranties Complies with ASHRAE 90.1-2006 and USA NAECA efficiency requirements Features environmentally friendlier R-410A refrigerant ENERGY STAR qualified Rating Up to 15.00 Seasonal Energy Ratio (SEER) and 9.0 Heating Seasonal Performance Factor (HSPF) Warranty 5-Year Limited Warranty on compressor 1-Year Limited Warranty on covered components The T-Class TSA/TPA line of air conditioners and heat pumps from Lennox is designed to help achieve comfort as well as energy savings. The advanced design includes high-quality components and, for added flexibility, is available with a choice of R-22 or R-410A refrigerant. Energy efficiency Lennox energy-efficient design features high-efficiency scroll compressors and outdoor coils that provide exceptional heat transfer, low air resistance and efficient operation. These units are rated up to 15.00 SEER and 9.0 HSPF to save hundreds of dollars in heating and cooling costs compared to lower-efficiency models. Easy installation and maintenance Arriving fully charged from the factory, Lennox air conditioning and heat pump units are designed to install quickly, with factory-wired control boxes and factory-tested coils. To ensure years of simple, low-cost service and maintenance, the units feature brass service valves, which provide easy access to the refrigerant system. The suction valve can be fully shut off while the liquid valve may be front-seated to manage refrigerant charge. Application solutions Lennox offers a large selection of options to meet a wide range of commercial HVAC needs. Customers can choose from a variety of voltages such as 208-230/3/60 and 460/3/60 for increased flexibility. Fieldinstalled accessories including low ambient kit options allow unit operation down to 30 F. Heat pump specific kits such as outdoor thermostats and kits for mild weather and monitoring are also available. Excellent reliability To guard against unexpected service costs, Lennox split systems feature durable components and safety features such as corrosion-resistant cabinets, drainage holes and enhanced fan and coil guards. High-pressure switches are standard on all R-410A models, and are available as field-installed kits for R-22 models. Other field-installed accessories, such as loss-of-charge and freezestat kits, provide additional protection when needed. All Lennox products are built according to demanding ISO-9001 standards and feature excellent warranties to provide peace of mind. The T-Class split systems can be ordered with R-22 or R-410A refrigerant. R-410A is the environmentally friendlier refrigerant introduced to replace R-22, which will be phased out within the coming years. R-410A units have been completely redesigned with a thicker, more durable compressor shell to withstand the refrigerant s higher pressure. The sturdier units vibrate less, so there s less strain on piping connections, where most leaks occur. Strict assembly procedures and larger refrigerant filter/ driers in the R-410A units reduce the chance of compressor failure. The high-quality synthetic used in the lubricant in the redesigned units helps protect parts from damage. Humidity control T-Class air conditioners and heat pumps with R-410A are also available with enhanced humidity control when you choose the optional Humiditrol dehumidification system.* Its patented design reduces moisture and helps control the spread of airborne contaminants such as mold. See actual warranty certificate for details. *Not for use with zoning applications.

field-installed accessories TSA/TPA Humiditrol Dehumidification System Improved reliability Compressor Low Ambient Cutoff Prevents compressor operation when outdoor temperature is below 35 F. Compressor Time-Off Control Improves compressor reliability by preventing short-cycling and allowing the compressor to start in an unloaded condition. Loss-of-Charge Kit (standard on R-410A heat pump models) Protects compressor from damage due to low refrigerant charge conditions. High-Pressure Switch Kit (standard on R-410A models) Protects the system from high-pressure conditions that can result from a fan failure or a blocked or dirty coil. Hail Guards Constructed of louvered heavy-gauge steel, hail guards surround unit on all four sides and prevent damage to the coil. Freezestat Prevents system failure in cold conditions by cycling the compressor off when the suction line temperature falls below the setpoint. Easy installation and maintenance Mounting Base Extremely durable high-density polyethylene structural material is lightweight, sturdy and provides a permanent foundation for outdoor units. Unit Stand-Off Kit Raises unit off the mounting surface and away from potentially damaging moisture. Refrigerant Line Kits Refrigerant lines are shipped cleaned, dried, pressurized and sealed at the factory for easy installation. Application solutions Low Ambient Control to 30 F Allows for unit operation down to 30 F. Mild Weather Kit Allows heating operation above 75 F (heat pump units only). Quiet and efficient operation Compressor Sound Cover Reinforced vinyl cover with fiberglass insulation helps lower operating sound levels. Time-Delay Relay Kit Improves comfort by delaying the blower-off time during the cooling cycle. Thermal Expansion Valve (TXV) Provides peak cooling performance across the entire application range. Enhanced humidity control Humiditrol dehumidification system reduces moisture and controls the spread of airborne contaminants. Minimum system requirements include: Humiditrol dehumidification system ComfortSense touchscreen thermostat Lennox variable-speed furnace or air handler Lennox air conditioner or heat pump with R-410A refrigerant Choose ENERGY STAR qualified products to reduce energy spending and conserve natural resources. Lennox has developed a wide range of products that meet ENERGY STAR guidelines for energy efficiency.* T-Class split systems are available with R-410A, an environmentally friendlier refrigerant. * Proper sizing and installation of equipment are critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR criteria. Ask your contractor for details or visit www.energystar.gov.

T-Class R-22 AC/hP Performance Specifications AIR CONDITIONERS Nominal Tonnage Model Sound Rating db 1 Cooling Data 2, 3 Heating DATA 4 Physical data ARI Rated Cap. [SEER] [EER] [HSPF] Capacity COP Dimensions H x W x L [inches] 3 TSA036S2 76 34,800 13.00 11.00 33.25 x 24.25 x 24.25 141 3.5 TSA042S2 79 41,500 13.00 11.00 29.25 x 28.25 x 28.25 171 4 TSA048S2 79 45,500 13.00 11.00 37.25 x 28.25 x 28.25 191 5 TSA060S2 79 58,000 13.00 11.00 33.25 x 28.25 x 28.25 216 Ship. Wt. [lbs.] HEAT PUMPS 3 TPA036S2 76 35,200 13.00 11.00 7.7 33,800 3.58 33.25 x 24.25 x 24.25 178 4 TPA048S2 80 50,500 13.00 11.00 7.7 47,500 3.42 37 x 28.25 x 28.25 248 5 TPA060S2 80 57,000 13.00 11.00 7.7 55,000 3.30 43.25 x 32.25 x 32.25 298 T-Class R-410A AC/hP Performance Specifications AIR CONDITIONERS Nominal Tonnage Model Sound Rating db 1 Cooling Data 2, 3 Heating DATA 4 Physical data ARI Rated Cap. [SEER] 5 [EER] [HSPF] 6 Capacity COP Dimensions H x W x L [inches] 3 TSA036S4 76 33,800 13.00 10.90 29.25 x 24.25 x 24.25 135 3.5 TSA042S4 79 40,500 13.00 10.90 29.25 x 28.25 x 28.25 178 4 TSA048S4 79 47,000 13.00 11.00 37.25 x 28.25 x 28.25 194 5 TSA060S4 79 59,000 13.00 11.00 33.25 x 28.25 x 28.25 218 Ship. Wt. [lbs.] 3 TPA036S4 76 34,200 13.00 10.85 8.0 34,200 3.60 33.25 x 24.25 x 24.25 180 HEAT PUMPS 3.5 TPA042S4 80 41,500 13.50 11.00 8.0 41,500 3.48 33.25 x 28.25 x 28.25 220 4 TPA048S4 80 48,000 13.00 11.00 7.7 45,500 3.36 37.25 x 28.25 x 28.25 250 5 TPA060S4 80 58,500 13.00 10.90 7.7 56,500 3.34 43.25 x 32.25 x 32.25 255 T-Class R-410A High-efficiency AC/hP Performance Specifications AIR CONDITIONERS Nominal Tonnage Model Sound Rating db 1 Cooling Data 2, 3 Heating DATA 4 Physical data ARI Rated Cap. [SEER] 7 [EER] [HSPF] 8 Capacity COP Dimensions H x W x L [inches] 3 TSA036H4 76 34,000 14.00 12.00 37.25 x 28.25 x 28.25 164 3.5 TSA042H4 78 41,500 14.00 12.00 29.25 x 28.25 x 28.25 198 4 TSA048H4 78 49,000 14.00 12.00 37.25 x 28.25 x 28.25 221 5 TSA060H4 80 58,000 14.00 12.00 33.25 x 32.25 x 32.25 238 Ship. Wt. [lbs.] 3 TPA036H4 79 34,600 14.00 12.00 8.2 35,200 3.64 29.25 x 32.25 x 32.25 212 HEAT PUMPS 3.5 TPA042H4 79 42,500 14.00 12.00 8.2 45,500 3.66 37 x 32.25 x 32.25 257 4 TPA048H4 80 49,000 14.00 12.00 8.2 47,000 3.6 37 x 32.25 x 32.25 262 5 TPA060H4 80 58,500 14.00 12.00 8.2 55,000 3.5 43.25 x 32.25 x 32.25 307 1 Sound rating number in accordance with test conditions included in ARI Standard 270. 2 5-ton-and-under equipment certified in accordance with ULE certification program, which is based on ARI Standard 210/240. 3 Cooling ratings, 95 F (35 C) outdoor air temperature and 80 F (27 C) db/67 F (19 C) wb entering indoor coil air. 4 High-temperature heating ratings, 47 F (8 C) db/43 F (6 C) wb outdoor air temperature and 70 F (21 C) entering indoor coil air. 5 Up to 14.00 SEER when the T-Class TSA060S4 split system is matched with the CBX26UH-060 air handler. 6 Up to 8.2 HSPF when the T-Class TPA036S4 split system is matched with the CR33-50/60C-F 4 coil and G61MPV-36C-090 furnace. 7 Up to 15.20 SEER when the T-Class TSA036H4 split system is matched with the CX34-49C and G71MPP-36C-090 furnace. 8 Up to 9.00 HSPF when the T-Class TPA042H4 split system is matched with the CX34-62D and G60UHV-60D-135 furnace. Note: Due to Lennox ongoing commitment to quality, all specifications, ratings and dimensions are subject to change.

High with Intelligent Design and High-Quality Components 7 6 10 3 2 1 9 8 11 4 5 Quiet and efficient operation 1 Scroll Compressor Provides smooth, efficient and quiet operation. 2 High- Outdoor Coil Provides exceptional heat transfer and low air resistance for high-efficiency operation. 3 Quiet, Direct-Drive Fan Precision-balanced, direct-drive fan is designed to run slower for an enhanced level of quiet operation. Easy installation and maintenance 4 Brass Service Valves Isolate the refrigeration system in outdoor units and allow for simple access. 5 Refrigerant Line Connections and Electrical Inlets Located in one central area of cabinet for easy access. Reliable performance 6 Fan Guard Heavy-duty guard increases safety. 7 Corrosion-Resistant Cabinet Galvanized steel under a two-layer painted surface protects against rust and corrosion. 8 Drainage Holes Prevent damaging moisture from collecting inside the basepan. 9 Enhanced Coil Guard Protects the outdoor coil, maintaining the efficiency of the unit. Heavy-gauge steel construction and non-corrosive PVC coating assure long-lasting protection. 10 Fan Motor Features a fully enclosed design with a rain shield to provide maximum protection from weather, dust, corrosion and moisture. 11 Crankcase Heaters Protect the compressor against refrigerant migration that can occur during low ambient operations. Solid-State Defrost Control Monitors the condition of the coil. Quickly and efficiently clears the build-up of frost on the coil (heat pump unit only, not shown).

Solutions for customized comfort Don t just choose a Lennox product choose a Lennox Commercial Comfort System. These complete packages of HVAC solutions provide tools to create a healthier and more comfortable environment. Packaged Units Strategos Rooftop Units S-Class Rooftop Units Landmark Rooftop Units L Series Rooftop Units T-Class Rooftop Units Split Systems S-Class Air Conditioners/ Heat Pumps T-Class Air Conditioners/ Heat Pumps Air Conditioners/Heat Pumps Air Handlers Indoor Coils Heating T-Class Unit Heaters Unit Heaters Duct Furnaces Furnaces Commercial Controls L Connection Network Systems Integration Solutions Commercial Thermostats Indoor Air Quality Humiditrol Dehumidification System Demand Control Ventilation Energy Recovery Ventilators/Systems Air Filters UVC Lamps (13W06)-06/08 Lennox Industries Inc. 2008 Visit us at www.lennox.com, or contact us at 1-800-9-LENNOX. Litho U.S.A. PC54064