PRELIMINARY NEW PRODUCT GUIDE. Zoneline Packaged Terminal Air Conditioners

Similar documents
all-season comfort GE Zoneline packaged terminal air conditioners New product introductions Spring 2010

Ge zoneline SinGle PackaGeD Vertical air conditioners Product Guide

SPACE SAVING & EFFICIENT Zoneline Single Packaged Vertical Air Conditioners

Zoneline vertical packaged terminal air conditioners

GE Zoneline. vertical packaged terminal air conditioners Home Products and Services

STREAMLINED & EFFICIENT

We bring good things to life. Zoneline. Packaged Terminal Units PRELIMINARY

GE zoneline. Packaged Terminal Air Conditioners

GE Zoneline packaged terminal air conditioners. AZ41/ contract sales architects and engineers data manual

GE Zoneline packaged terminal air conditioners contract sales architects and engineers data manual

PTAC/PTHP. Packaged Terminal Air Conditioners and Heat Pumps. Residential & Light Commercial HVAC. Features: Performance:

PTW 42 Series 230/208 VOLT

Packaged Terminal Air Conditioner (PTAC)

Packaged Terminal Air Conditioner (PTAC)

Packaged Terminal Air Conditioner (PTAC)

NEW 2011 DESIGN AIR CONDITIONERS

Packaged Terminal Air Conditioner (PTAC)

PTAC 2017 Air Conditioner Collection

FRIGIDAIRE PTAC COLLECTION AIR CONDITIONERS

Vert-I-Pak Series. Single Package Vertical Air Conditioners. Installs easily in a closet for quiet operation THE EXPERTS IN ROOM AIR CONDITIONING

Single Package Vertical Air Conditioners. Vert-I-Pak

built-in comfort GE built-in air conditioners and heat pumps

ARCHITECTS AND ENGINEERS DESIGN DATA MANUAL

Important Safety Information. Operating Instructions The Controls on Your Zoneline Care of Product

Series PIN. New Construction or Renovation. Application Flexible Quiet Comfort Damage Protection

PACKAGED TERMINAL AIR CONDITIONERS

NEW! Digital Packaged Terminal Air Conditioners. Over 40 standard features! Distinct, audible sound improvements

Technical Service Guide

Air Conditioners. Zoneline.

PTAC Air Conditioners 11.7 EER / 3.4 COP. and Heat Pumps

GE AIR CONDITIONER ACCESSORIES Split System/Built-In/Window/Zoneline Models

PTAC Air Conditioners 11.7 EER / 3.4 COP. and Heat Pumps

PACKAGED TERMINAL AIR CONDITIONER SOLUTIONS

built-in comfort GE built-in air conditioners New product introductions January 2010

VERT-I-PAK SERIES SINGLE PACKAGE VERTICAL AIR CONDITIONERS

PACKAGED TERMINAL AIR CONDITIONER SOLUTIONS. New Construction Model. Model EGN Superior Sound Performance. High Efficiency

Important Safety Information. Operating Instructions The Controls on Your Zoneline Care of Product

Incremental Comfort Conditioners

Packaged Terminal Air Conditioners

Air Conditioners. Zoneline Vertical. GEAppliances.com

THRU-THE-WALL AIR CONDITIONERS

E Z S E R I E S " W X 16" H

Boston Green Tourism. Upgrading Hotel PTAC units When & Why October 23, Donna Sheeran Store Manager Trane Supply

PACKAGED TERMINAL AIR CONDITIONER SOLUTIONS. New Construction Model. Model EGN Superior Sound Performance. High Efficiency

room air conditioners #1 preferred brand of room air conditioners.

2014 Duct Free Split Air Conditioners, PTAC & Through-the-Wall AC. Open the door to a new world of cooling & heating.

Air ConditionersSafety Instructions

ROOM AIR CONDITIONERS

Series PIC. New Construction and Renovation; Replaces RetroAire VPAC and First Company DPU Application Flexible Quiet Comfort Damage Protection

Packaged Terminal Air Conditioners. SG Series. Efficient and reliable for the lowest cost of ownership. More efficient. More reliable.

SG SERIES PTACs THE EXPERTS IN ROOM AIR CONDITIONING

We bring good things to life. GE Room Air Conditioners The 1997 Line

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

Applied Packaged Terminal Air Conditioner with Catalog Top-Mounted Hydronic Heat

McQuay Suite Type N Top Mounted Hydronic Heat Incremental Packaged Terminal Air Conditioners C:

UseandCare & Installation Guide

OWNER S MANUAL PACKAGED TERMINAL AIR CONDITIONERS AND HEAT PUMPS

Packaged Terminal Air Conditioners & Heat Pumps

Product Profile Packaged Terminal Air Conditioners

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

Owner s Manual. Important Safety Information. Operating Instructions The Controls on Your Air Conditioner Care of Product

TECHNICAL SPECIFICATIONS

52C 52C and 52P SERIES OWNER S MANUAL PACKAGED TERMINAL AIR CONDITIONERS AND HEAT PUMPS. 7,000-15,000 Btuh

SPXB-HW Series Single Package Vertical Unit Cooling with Hot Water Heat 1 through 2 tons, up to 47,800 BTUH Heating

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA

Feel the difference! Uncompromised Comfort Unrivaled Value C US. Mark of Superior Quality SERIES

HEAT PUMPS. Efficient Comfort For Every Season

Greensource iseries Water Source Heat Pumps. SV Model. Made in Florida boschheatingandcooling.com

DUCTLESS ROOM AIR CONDITIONERS

Service Manual R410A Models

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

The XP17 provides comfort without comparison.

AIR CONDITIONERS 2017 COLLECTION. Window Portable Dehumidifier Through The Wall Ductless Split Units

Greensource Residential Water Source Heat Pumps. Simply Smart. i Series: SV Model. boschheatingandcooling.com

ROOM AIR CONDITIONERS cool only heat pumps electric heat

THE WORLD S MOST EFFICIENT HEAT PUMP

TECHNOLOGY GUIDE. :: the dawn of a new era in commercial HVAC technology. The all-new Rheem Commercial Renaissance Line featuring:

The XP21 raises the bar for efficiency and comfort.

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

How to Select and Size Enclosure Thermal Management Systems: White Paper, Title Page. How to Select and Size Enclosure Thermal Management Systems

TECHNICAL SERVICE GUIDE

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

EASY DOES IT. Multiple Fan Speeds with Auto Cool

A heat pump that redefines comfort and efficiency.

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

Hazardgard. Product Profile. Engineered to perform in the harshest environments. Hazardous Location Room Air Conditioners

Liebherr's engineering excellence in Germany provides the largest selection of freezers, refrigerators and wine refrigerators worldwide.

SPXA / SPXA-HP Series Single Package Vertical Unit Straight Cool and Heat Pump 3/4 through 2 tons, up to 10 kw Electric Heat

An air conditioner that redefines comfort and efficiency.

SPXB / SPXB-HP Series Single Package Vertical Unit Straight Cool and Heat Pump 3/4 through 2 tons, up to 10 kw Electric Heat

Service Instructions

Geniuses at work. Residential Mini Splits

Xc21 air conditioner up to seer Xc21

Digi-Motor. ECM for Commercial Refrigeration. Toll Free (800) Fax (631)

AIR HANDLERS R-410A, Variable-Speed TOUGH. SMART.

CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH

CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH

9 EER 1-5 Ton Vertical Packaged Wall Mount Air Conditioners

Transcription:

PRELIMINARY NEW PRODUCT GUIDE Zoneline Packaged Terminal Air Conditioners

GE ZONELINE A Story of American Invention In 1961, the GE Zoneline PTAC began making its way into hotels and motels across the country, changing the face of comfort on the road. Now, over 50 years later, GE Zoneline has been reinvented in Louisville, Kentucky, to meet the changing needs of America s hotel industry. The newest GE Zoneline PTACs are engineered to be more reliable, efficient, quieter and incredibly easy to install and maintain. 2

PRELIMINARY KEY BENEFITS HOTELIERS WILL LOVE The new GE Zoneline leads the industry in four categories: RELIABLE QUIET EFFICIENT NEW APPEARANCE 3

4

PRELIMINARY RELIABLE With over one million units installed across the U.S. and remarkably low service issues, GE Zoneline PTACs offer unrivaled reliability, consistent performance and constant guest comfort. UNMATCHED SERVICE & SUPPORT GE Appliances is the only manufacturer with a dedicated factory service network and field team. Our technicians service your Zoneline and any other GE appliances you have in no time, so guest comfort is not compromised. FEATURE HIGHLIGHTS: REDESIGNED STRUCTURE Simplified and streamlined so servicing is faster and easier than ever before. PREMIUM GUARD CORROSION PROTECTION Special coatings keep each part performing at peak condition, longer. EASY TO SERVICE New Zonelines have integrated structural components for easy maintenance and support. IMPROVED DESIGN Rustproof base pan comes standard on all models. SERVICE DIAGNOSTICS PORT Technicians can quickly diagnose problems. QUICK CONNECT The thermostat, central desk control and external fan can be connected in seconds for faster installation and servicing. 5

6

PRELIMINARY QUIET Quiet operation has always been a strong suit of Zoneline. It s the quietest PTAC when compared to leading competitors *, so you know your guests will always get a good night s rest. WHERE IT COUNTS Typical outdoor noises such as those from traffic or airports present challenges to hotel owners every day. When tested against leading competitors, GE Zonelines block the most outdoor noise with a sound transmission class of 29 * that s the highest PTAC STC on the market. That means Zonelines help guests sleep better and can support high guest ratings for hotel and motel properties. STC (Sound Transmission Class) 29 GE Appliances Comp A Comp A (2) Comp B Comp C Guests who are dissatisfied with the room noise or temperature: 33 % 66 % ARE NOT LIKELY ARE NOT LIKELY TO RECOMMEND THE HOTEL** TO RETURN TO THE HOTEL** GE Appliances Zonelines provide quiet comfort for hotel rooms. FEATURE HIGHLIGHTS: BAKED-ON MASTIC A heavy-duty barrier covers the back of the unit for superior sound insulation. WEATHER BARRIER SYSTEM SEAL A seal around the perimeter of the unit keeps noise and dirt outside. TWO DC FAN MOTORS A motor for each fan reduces noise by dialing in the exact airflow needed for each heating and cooling function. LARGE CROSS-FLOW BLOWER Airflow is optimized for a low, balanced sound that is hardly noticeable. SMART FAN COOLING/HEATING Allows the fan to run in either continuous mode during hot weather or cycle mode during the winter months, saving energy and improving guest comfort. * 12,000 BTUh heat pump models tested by independent third-party testing at a national acoustical lab, conducted March 2015 and October 2015, in accordance with ASTM and AHRI standards. The higher the STC rating, the better the unit blocks outside noise. ** Clarabridge Ratings and Reviews, for hospitality data collected July 2013 June 2014. Americans' biggest complaints about hotels Forbes Magazine, July 27, 2012 issue. 7

8 FPO_Stock

PRELIMINARY EFFICIENT GE Zoneline PTACs are highly efficient. Zoneline heat pumps can save a property hundreds of dollars per month in utility expenses. * On average, Zoneline is 8% more efficient than the leading competitor for 7,000 BTUh and 9,000 BTUh electric resistance heat models, for more savings per room, per year. ** That all adds up to lower operation costs. WHY IT MATTERS Decreasing the energy usage of your properties can save you a lot of money. Since Zoneline PTACs are one of the industry leaders in efficient operation, you ll be able to cut utility bills without compromising the comfort of your guests. FEATURE HIGHLIGHTS: REVERSE CYCLE DEFROST Prolongs heat pump operation, saving energy and money. ELECTRONIC TEMPERATURE LIMITING Limits are preset to save energy and avoid excessive temperature swings. HEAT & FREEZE SENTINELS Specially designed sentinels protect your property by preventing overheating or freezing. EXTENSIVE HEAT SOURCE LOGIC Smart technology lets each unit automatically select the right heat source to efficiently meet guest needs. SMART PROGRAMMING Every unit is programmed to balance guest comfort with efficient operation. *Savings depend on region, equipment, structure and other factors. ** GE Zoneline AZ45 and AZ65 Series models for 7,000 BTUh and 9,000 BTUh electric resistance models, vs. leading competitor for comparable models with average EER values of listed models, per AHRI listing October 2015. 9

10

PRELIMINARY NEW APPEARANCE The Zoneline boasts a slimmer room front, sleek appearance and fresh color, providing an updated look that blends in seamlessly with any hotel décor and room design. Even though it has the same footprint for easy replacement, it also has the industry s slimmest room front, so Zoneline provides more open space for guests to enjoy. STREAMLINED, INSIDE AND OUT The new Zoneline looks sleeker on the outside, but is also more efficiently engineered inside. FEATURE HIGHLIGHTS: BACKLIT, COVERLESS CONTROL PANEL Improved display with large, white LED lights and no lid cover keep this unit looking like new. SLEEK APPEARANCE Enjoy the same case dimensions with a shallower depth for more usable room space. FRESH COLOR Perfectly blends in with modern interior designs. DIMMING DISPLAY Automatic dimming feature makes sure LED lights are never too bright at night. 11

FEATURE HIGHLIGHTS The new Zoneline continues a legacy of energy efficiency and guest comfort, thanks to innovative features that property managers love. BLOWER & DC MOTORS Cross-flow blower, two DC fan motors and smart fan cooling and heating keep the unit quiet while providing efficient heating and cooling performance HEAT & FREEZE SENTINEL Keeps room from overheating or freezing to increase efficiency and comfort while decreasing operating and maintenance costs SYSTEM COMPATIBILITY ompatible with a wide variety of thermostats C and energy management systems, including central desk control 12

PRELIMINARY PREMIUM GUARD CORROSION PROTECTION * Special coatings, paintings and stainless steel ensure lasting performance in challenging environments such as oceanfront properties HEAT PUMP FEATURES Reverse cycle defrost increases efficiency and allows unit to run in heat pump mode longer Backup resistance heat delivers quick heating comfort Internal Condensate Removal (ICR) also available on select models DRY AIR 25 * Patented dehumidifier heat pipe removes up to 25% more humidity from a room ELECTRONIC TOUCH CONTROLS Easy-to-use controls with clear LED readout provide a user-friendly experience Ideal for properties in ocean environments and high-humidity areas WEATHER BARRIER SYSTEM SEAL Keeps noise, dirt and grime outside Creates a quieter room and more efficient operation ELECTRONIC TEMPERATURE LIMITING Prevents expensive overcooling and overheating of rooms Limits are automatically set, so seasonal adjustments aren t necessary *Available on select models 13

RESISTANCE HEAT 4500 SERIES RESISTANCE HEAT UNITS* Digital LED display Solid-state thermostat Variable vent control Automatic indoor frost control 2 DC fan motors Heat & Freeze Sentinel Remote thermostat capability Models with Premium Guard Corrosion Protection are also available* 4500 SERIES COOLING & ELECTRIC RESISTANCE HEAT 230/208V MODELS AZ45E07D AZ45E09D AZ45E12D AZ45E15D Cooling BTUh 7,200/7,000 9700/9600 11,800/11,500 14,900/14,800 EER (BTUh/Watt) 13.4/13.4 12.1/12.1 11.8/11.8 10.5/10.5 Dehumidification Pts/Hr 1.7 2.7 3.5 4.6 Refrigerant type R-410A R-410A R-410A R-410A CFM, indoor fan high 290 340 420 409 CFM, indoor fan low 218 229 323 324 Power factor 89% 93% 93% 90%/92% Sensible heat ratio @ 230 volts 80% 75% 70% 70% Watts 535/520 800/790 1,010/1,000 1,415/1,405 Cooling amperes, F.L. 2.5/2.5 3.6/3.9 4.7/5.0 6.4/6.8 Amperes, L.R. 13.5 21.0 29.5 31.5 Weight (Net/Ship) 89/103 100/113 99/112 100.3/113.3 265V MODELS AZ45E07E AZ45E09E AZ45E12E AZ45E15E Cooling BTUh 7,200 9,400 11,800 14,300 EER (BTUh/Watt) 12.3 12.0 11.1 10.3 Dehumidification Pts/Hr 1.7 2.7 3.5 4.6 CFM, indoor fan high 290 340 420 406 CFM, indoor fan low 215 229 323 324 Power factor 90% 91% 92% 92% Sensible heat ratio @ 265 volts 80% 75% 70% 70% Watts 580 805 1,025 1,385 Cooling amperes, F.L. 2.4 3.2 4.1 5.7 Amperes, L.R. 11.7 16.5 23.5 26.0 Weight (Net/Ship) 92/105 101/114 100/113 101/114 Specifications subject to change. *Premium Guard Corrosion Protection model BTUh and watts may vary. 14

RESISTANCE HEAT PRELIMINARY 4500 SERIES DRY AIR 25 RESISTANCE HEAT UNITS Digital LED display Solid-state thermostat Variable vent control Automatic indoor frost control 2 DC fan motors Heat & Freeze Sentinel Remote thermostat capability Premium Guard Corrosion Protection standard on all Dry Air 25 models DRY AIR 25 SERIES COOLING & ELECTRIC RESISTANCE HEAT 230/208V MODELS AZ45E07DAP AZ45E09DAP AZ45E12DAP Cooling BTUh 6,500/6,300 9,200/8,800 11,200/11,000 EER (BTUh/Watt) 11.9/11.9 11.5/11.5 10.8/10.8 Dehumidification Pts/Hr 2.3 3.4 4.4 Refrigerant type R-410A R-410A R-410A CFM, indoor fan high 220 280 330 CFM, indoor fan low 190 208 270 Power factor 86%/87% 92% 92% Sensible heat ratio @ 230 volts 60% 60% 60% Watts 555/535 790/765 1,035/1,015 Cooling amperes, F.L. 2.8/3.0 3.6/3.9 4.7/5.1 Amperes, L.R. 19.5 21.0 29.5 Weight (Net/Ship) 97.0/110.0 106/121 114/129 265V MODELS AZ45E09EAP AZ45E12EAP Cooling BTUh 9,200 11,200 EER (BTUh/Watt) 11.5 10.8 Dehumidification Pts/Hr 2.7 3.5 CFM, indoor fan high 340 420 CFM, indoor fan low 229 323 Vent CFM (full open/partial open) 70/45 75/45 Power factor 91% 92% Sensible heat ratio @ 265 volts 60% 60% Watts 805 1,025 Cooling amperes, F.L. 3.2 4.1 Amperes, L.R. 16.5 23.5 Weight (Net/Ship) 101/114 100/113 Specifications subject to change. 15

HEAT PUMP 6500 SERIES HEAT PUMP UNITS* Staged heating Heat pump with resistance heat backup Electric resistance heat lockout Reverse cycle defrost Models with Premium Guard Corrosion Protection and ICR are also available ** 6500 SERIES HEAT PUMP UNITS * 230/208V MODELS AZ65H07D AZ65H09D AZ65H12D AZ65H15D Cooling BTUh 7,100/6,900 9,700/9,600 12,100/11,900 14,400/14,200 EER (BTUh/Watt) 12.8/12.8 12.2/12.2 11.9/11.9 10.6/10.6 Dehumidification Pts/Hr 1.7 2.7 3.5 4.5 Refrigerant type R-410A R-410A R-410A R-410A CFM, indoor fan high 340 360 370 370 CFM, indoor fan low 194 212 284 290 Power factor 91% 92% 92% 91%/92% Cooling watts 545/535 795/785 1,015/1,000 1,355/1,335 Cooling amperes, F.L. 2.5/2.7 3.6/3.8 4.5/4.9 6.1/6.5 Amperes, L.R. 13.5 21.0 29.5 31.5 Reverse cycle heat BTU 6,200/6,100 8,100/8,000 10,500/10,400 13,400/13,300 COP 3.9/3.9 3.7/3.7 3.6/3.6 3.3/3.3 Heating watts 465/455 650/635 855/835 1,190/1,180 Heating amperes 2.2/2.3 3.1/3.3 4.1/4.5 5.2/5.6 Weight (Net/Ship) 94/107 101/114 102/115 101/114 265V MODELS AZ65H07E AZ65H09E AZ65H12E AZ65H15E Cooling BTUh 7,000 9,400 11,700 14,400 EER (BTUh/Watt) 12.8 12.2 11.6 10.6 Dehumidification Pts/Hr 1.7 2.7 3.5 4.5 Refrigerant type R-410A R-410A R-410A R-410A CFM, indoor fan high 340 360 370 370 CFM, indoor fan low 194 211 284 290 Vent CFM (full open/partial open) 50/40 70/45 75/45 75/45 Power factor 92% 90% 92% 93% Sensible heat ratio @ 265 volts 85% 75% 70% 65% Cooling watts 540 760 1,015 1,355 Cooling amperes, F.L. 2.2 3.1 4.0 5.4 Amperes, L.R. 11.7 16.5 23.5 26.0 Reverse cycle heat BTU 6,200 8,100 10,700 13,500 COP 3.9 3.6 3.6 3.3 Heating watts 455 665 880 1,270 Heating amperes 2.0 2.7 3.6 5.0 Weight (Net/Ship) ** 97/117 106/119 107/120 106/119 *Premium Guard Corrossion Protection model BTUh and watts may vary. **ICR adds 3 pounds to unit weight. Specifications subject to change. 16

GE APPLIANCES ZONELINE WARRANTY PRELIMINARY FOR THE PERIOD OF ONE YEAR From the date of the original purchase GE APPLIANCES WILL REPLACE Any part of the air conditioner which fails due to a defect in materials or workmanship. During this limited one-year warranty, GE will provide, free of charge, all labor and related service costs to replace the defective part. FIVE YEARS From the date of the original purchase Sealed Refrigerating System, if any part of the Sealed Refrigerating System (the compressor, condenser, evaporator, and all connecting tubing) should fail due to a defect in materials or workmanship. During this limited five-year warranty, GE will provide, free of charge, all labor and related service costs to replace the defective part. SECOND THROUGH FIFTH YEAR From the date of the original purchase Fan Motors, Switches, Thermostat, Heater, Heater Protectors, Compressor Overload, Solenoids, Circuit Boards, Auxiliary Controls, Thermistors, Freeze Sentinel, Frost Controls, ICR Pump, Capacitors, Varistors and Indoor Blower Bearing, if any of these parts should fail due to a defect in materials or workmanship. During this additional four-year limited warranty, the customer will be responsible for any labor and related service costs. ZONELINE CHASSIS NOMENCLATURE A Z 6 5 H 1 2 D A D Chassis series 45=cool/electric heat 65=heat pump Unit type E= cooling with electric resistance heat H= heat pump with electric resistance heat Nominal cooling capacity 07=7,000 BTUh cooling 09=9,000 BTUh cooling 12=12,000 BTUh cooling 15=15,000 BTUh cooling Voltage/Phase/Frequency D= 230/208 Volt, single phase, 60 Hz E= 265 Volt, single phase, 60 Hz Universal power connection Special features B=base unit C=corrosion treated D=internal condensate removal (ICR) system (heat pump models only not for coastal applications) M=Makeup Air P=Dry Air 25 17

ACCESSORIES A look inside: WALL CASE CROSS-FLOW BLOWER GRILLE ROOM FRONT CHASSIS WALL CASE OPTIONS RAB71B, RAB77B Extended sleeves available in 16" and 24" depths THERMOSTATS Digital RAK148D2, RAK164D2 Programmable RAK148P2, RAK164P2 GRILLE OPTIONS Architectural rear grille Extruded aluminum RAG67 Stamped aluminum RAG60 High-impact polymer grille Beige RAG61 Maple RAG62 Bittersweet RAG63 RETROFIT KITS RAK40 Deflector kit STANDARD SUB-BASE WITH POWER CORD INCLUDED RAK204D15PA RAK204D20PA RAK204D30PA 18

POWER CONNECTION KITS ARE REQUIRED ON ALL ZONELINE CHASSIS. (See chart below) PRELIMINARY The correct kit for the installation is determined by the voltage and amperage of the electrical circuit and the means of connecting the unit to the building wiring. If the unit is to be plugged into a receptacle, a line cord kit would be used; if the unit is to be permanently connected, a permanent connection kit would be used. Cord set units of 265 volts must be installed in compliance with National Electrical Code. POWER CONNECTION KITS Required on all models. See specification information below for heater kwh and branch circuit ampacity. RAK315P/320P/330P 230/208 volt line cord connection kit Also available with short power cords RAK315D/320D/330D 230/208 volt universal power supply kit RAK515D/520D/530D 265 volt universal power supply kit 7,000/9,000 BTUH 230/208 VOLT LINE CORD CONNECTED UNITS LCDI Power Connection Kit RAK315P RAK320P RAK330P Heater kwh 2.4/1.99 3.42/2.83 4.83/3.98 Watts 2,401/1,989 3,418/2,825 4,827/3,984* BTU 8,187/6,782 11,655/9,633 16,460/13,585 Amps 10.4/9.6 14.9/13.6 21.0/19.2 Min. circuit amps 15 20 30 Recommended protective device 15 amp timedelay fuse or breaker 20 amp timedelay fuse or breaker 30 amp timedelay fuse or breaker 7,000/9,000 BTUH 265 VOLT PERMANENT CONNECTED UNITS** (CORD SET) RAK515P RAK520P RAK530P 2.4 3.4 4.8 2,400 3,400 4,800 8,150 11,550 16,350 9.6 13.3 18.6 15 20 30 15 amp time-delay fuse or breaker 20 amp time-delay fuse or breaker 30 amp time-delay fuse or breaker 7,000/9,000 BTUH 230/208 VOLT DIRECT CONNECTION KIT RAK315D RAK320D RAK330D Heater kwh 2.4/1.99 3.42/2.83 4.83/3.98 Watts 2,401/1,989 3,418/2,825 4,827/3,984* BTU 8,187/6,782 11,655/9,633 16,460/13,585 Amps 10.4/9.6 14.9/13.6 21.0/19.2 Min. circuit amps 15 20 30 Recommended protective device 15 amp timedelay fuse or breaker 20 amp timedelay fuse or breaker 30 amp timedelay fuse or breaker 7,000/9,000 BTUH 265 VOLT DIRECT CONNECTION KIT RAK515D RAK520D RAK530D 2.4 3.4 4.8 2,400 3,400 4,800* 8,150 11,550 16,350 9.6 13.3 18.6 15 20 30 15 amp time-delay fuse or breaker 20 amp time-delay fuse or breaker 30 amp time-delay fuse or breaker *Wattage less when in low fan. **To be used with sub-base. To be used with sub-base or connection to building wiring. Specifications subject to change. Wall case and exterior grille are also required for new construction. Specs may vary for 12,000/9,000 BTUh models. ADDITIONAL ACCESSORIES AVAILABLE For example, drain kits, adapter, exterior air deflector kits and filters. Visit Zoneline.com for full listing. 19

Appliance Park Louisville, KY 40225 geappliances.com zoneline.com 888.231.2548 2016 GE Appliances Pub. No. 20-T055 PC82903