Carbon monoxide (CO) is a colorless, odorless gas that is the product of incomplete combustion of carbon-based fuels.

Similar documents
Materials Testing by Gregory Havel

Carbon Monoxide Alarm

Model Carbon Monoxide (CO) Alarm Response Policy

Combustion Safety. RESNET Conference San Antonio, TX February 27, Presented by Rich Moore Lightly Treading Energy & Design Denver, CO

Manhattan Fire Protection District

Travis County Emergency Services District #1 Standard Operating Guidelines

Good Ideas For Propane Safety

Response to Carbon Monoxide Incidents. W.J. Streett Jr Training Section Chief

COMBUSTION SAFETY BASICS

Carbon Monoxide Safety Information

OXYGEN. 21% in air. Does not burn - Supports combustion. Increased oxygen will intensify burning

RESNET National Conference New Orleans, LA. February 16, 2009 Presented by Rich Moore Invisible Energy Denver, CO

State of ALASKA, Weatherization Assistance Program. Technical Support Document. Combustion Safety

Frequently Asked Questions About Carbon Monoxide Detectors

Natural Gas Appliance Testing Action Guidelines (Non ESA/Low Income 5 )

Content Rev

The basic fire theory says that a fire needs four main elements in order to start: heat, fuel, oxygen, and a chain reaction. This theory is known as t

FIRE PREVENTION AND SAFETY IN THE HOME. Provided to You by Lawrence Laviolette CD Fire Safety Officer

Whole House Action Guidelines

From Your Building Inspector

Special Edition. Routt County Office of Emergency Management. Carbon Monoxide The Silent Killer. What is Carbon Monoxide (CO)?

What is carbon monoxide (CO) and why do I need a carbon monoxide detector?

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

Fire Prevention Plan for St. Barbara Hall 3904 Winding Way

LOMBARD FIRE DEPARTMENT ILLINOIS CARBON MONOXIDE ALARM DETECTOR LAW. Carbon Monoxide Law. Takes effect January 1, 2007 One outside each sleeping area

SAFETY TIPS. From Your Building Inspector. The Sound of Safety.

VENTING CLEARANCES. BBT NORTH AMERICA Bosch Group. Bosch Water Heating 340 Mad River Park, Waitsfield, VT TWH-V-26 page 1 of 6 rev 01/06

Retrofit Installer-Mechanical

2. Gas B. The column of hot gases, flames, and smoke rising above a fire; also called convection column, thermal updraft, or thermal column

U.S. Consumer Product Safety Commission Washington, DC 20207

TIMOTHY R. SZYMANSKI Instructor

Agenda. Intro Objective What is Carbon Monoxide Carbon Monoxide Law History Nelsons Law NFPA 720

Xavier Field Office Fire Prevention Plan. for. Xavier Field Office Dana Avenue

RESNET National Conference New Orleans, La. February 15, 2009 Presented by Rich Moore Invisible Energy Denver, CO

PROTECTING AGAINST CARBON MONOXIDE. Questions and Answers about Carbon Monoxide (CO) and CO Alarms

Guidelines for the Design Engineer

Carbon Monoxide Poisoning

Carbon Monoxide Detection in Buildings Frequently Asked Questions

In accordance with the Department of Labor and Industry s statute , Subd. 11,

about your house Assessing the Comfort and Safety of Your Home s Mechanical Systems

PLUMBING & CARBON MONOXIDE

CARBON MONOXIDE DETECTOR, i4h-co-m330

CARBON MONOXIDE (CO)

Objectives. Home Performance Diagnostics with the House of Pressure (Part 1) How can Pressure effect Building Performance?

Seriously how do you know your CO monitor is Working!

Fire Prevention Plan for Residence Life 1625 Musketeer Drive

COMBUSTION APPLIANCE SAFETY INSPECTION FOR VENTED APPLIANCES*

NJSP HMRU. Module 5 B HM Operations 1

Fire Prevention Plan for Bellarmine Parish Center 3832 Ledgewood Avenue

CORPUS CHRISTI FIRE PREVENTION MOBILE FOOD VENDOR REQUIREMENTS

2.1 CO is a colorless, odorless, tasteless, non-irritating, toxic gas.

Instructions for High Altitude Installations Above 4500 FT.

Home Heating MORE THAN JUST STAYING WARM

Fire Prevention Plan for

SAFETY AND MAINTENANCE TIPS FOR NATURAL GAS USERS FROM THE VILLAGE OF DIVERNON

Fire Prevention Plan for Alter Hall 3743 Ledgewood Drive

Fire Prevention Plan for Campus Services Building 1630 Musketeer Drive

ARCHIVED. Compliance Document for New Zealand Building Code Clause G4 Ventilation Second Edition. Prepared by the Department of Building and Housing

Setting the alarms in electrochemical sensor equipped toxic gas instruments

Topic: Mechanical Ventilation Refresher Reference #: DG Level of Instruction: In service personnel Time Required: 3 hours

Macurco Gas Detection Products

Aluminum Dust Management in a Metallizing Facility

The evil that men do lives after them; the good is oft interred with their bones.

Family Foster Home Fire Safety Evaluation Checklist Instructions

JAMES MOODY IM FLASH LIFE SAFETY AHJ

Fire Prevention Plan for McGrath Health and Wellness Center 1714 Cleneay Avenue

ATTACHMENT D #1 - HVAC (OIL) - SINGLE FAMILY DWELLINGS Category C: OIL

CUSTOMIZED TEACHER ASSESSMENT BLUEPRINT HVAC MAINTENANCE TECHNOLOGY. Test Code: 5937 Version: 01

BOOK 1 OVERVIEW RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

HOMEOWNER'S GUIDE FOR YOUR CONTEMPO FIREPLACE TABLE OF CONTENTS

Inspection Checklist Mechanical Rough in

USER S INFORMATION MANUAL

Uniform Dwelling Code 2017 Updates SPS 323

Carbon Monoxide: The High Cost and Affects of Complacency

The Heating System and Ventilation and Combustion Air

EL296UHV SERIES GAS FURNACE WARNING WARNING

USER S INFORMATION MANUAL

Energy Saver 101: Home Energy Audits

Max Fire Box Users Guide

PREVIEW COPY. Heating System Equipment. Table of Contents. Gas Heating Equipment...3. Oil Heating Equipment Electric Heating Systems...

System-Connected Carbon Monoxide Detectors

Operating instructions

Incident Summary (II )

CHAPTER 15: FIRE PREVENTION & AWARENESS POLICY

USER S INFORMATION MANUAL

carbon monoxide Preventing carbon monoxide poisoning in your home

FIRE PROTECTION PROGRAM

Battery Powered Commercial CO Monitor

John Jay College of Criminal Justice HOT WORK PERMIT STANDARD OPERATING PROCEDURES

MONTH-BY-MONTH GUIDE TO HVAC MAINTENANCE

Carbon Monoxide Detectors. What is carbon monoxide?

BOOK 1 OVERVIEW RD2XIN INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

OPERATING INSTRUCTIONS AND OWNER S MANUAL

Chimney Fire Prevention

WELDING, CUTTING, AND BRAZING SAFETY PROGRAM

General Industry Safety and Health Checklist Guidelines. Building and Premises. Loss Control Bulletin

GASEOUS HYDROGEN SYSTEMS

P.O. Box , Dallas, TX USER'S INFORMATION MANUAL Single-Stage Warm Air Gas Furnaces

September 1, Sincerely, Mike Montgomery Fire Marshal. M.S. Montgomery Fire Marshal

Glossary. Carbon Dioxide (CO 2

Transcription:

Construction Concerns: Carbon Monoxide November 20, 2017 By Gregory Havel Carbon monoxide (CO) is a colorless, odorless gas that is the product of incomplete combustion of carbon-based fuels. The chemical reaction for the normal combustion of carbon that takes place with enough oxygen is: C + 0 2 CO 2 (carbon atom plus oxygen molecule (two atoms) yields carbon dioxide molecule.) This chemical reaction is expected to take place in boilers and furnaces, and in fuel-controlled fires. When there is too much fuel that is pyrolyzing or not enough oxygen to support complete combustion, the chemical reaction is: 2C + 0 2 2CO (Two carbon atoms plus oxygen molecule (two atoms) yields two carbon monoxide molecules.) This chemical reaction takes place in boilers and furnaces with too little oxygen, and in room-and-contents and structure fires that are ventilation controlled. When carbon monoxide has been produced from incomplete combustion, it can finish burning in the chemical reaction: 2CO + O 2 2CO 2 (Two carbon monoxide molecules plus oxygen molecule (two atoms) yields two carbon dioxide molecules.) This chemical reaction can take place in the boiler or furnace flue pipe or chimney or outside the structure. If the chemical reaction does not take place, the unburned CO becomes an atmosphere contaminant that affects air quality. This chemical reaction can take place in the room contents fire s discharge flow-path, causing roll-over or flame-over, the results of combustible products of combustion mixing with the oxygen in the fresh air and igniting. If the mixing with fresh air is thorough and rapid enough, the ignition of the gases can be explosive, resulting in a backdraft or smoke explosion. These chemical reactions are the same whether they take place in a furnace or boiler, a fireplace, a room contents fire, or a conflagration. Carbon monoxide produced by heating appliances is of little consequence to a homeowner, the owner of a commercial building, or a contractor at a building under construction, unless the CO enters the occupied space either from heating appliance defects or from inadequate venting of the combustion chamber. When CO enters November 2017 Page 1 of 7

occupied building spaces, it tends to increase in concentration in human blood to the point that occupants become ill. The U.S. Occupational Safety and Health Administration (OSHA) has established a permissible exposure limit (PEL) of 50 parts per million time-weighted average (TWA) of carbon monoxide in the air in the workplace as being safe for an eight-hour workday. The National Institute for Occupational Safety and Health (NIOSH) of the Centers for Disease Control (CDC) recognizes that some people are more sensitive to carbon monoxide than others, and has established a recommended exposure limit (REL) of 35 parts per million CO time-weighted average for an eight-hour workday. Common sources of carbon monoxide on construction job sites are temporary heating appliances inside buildings and other enclosures that are operating without enough air for complete combustion (sometimes done deliberately to reduce fuel costs); and from internal combustion engines running inside buildings without adequate ventilation. One type of temporary heating appliance for construction job sites has a trailer located outside the building (Photo 1, above) that contains a fuel source, a combustion chamber, a heat exchanger, and a pump. The fuel is burned in the combustion chamber outside the building. Antifreeze solution is circulated through the heat exchanger, hoses, and terminal units (hot-water coils with fans) inside the building. This type of heater provides little chance of CO contamination inside the building, since the combustion chamber and its vent are located outside. November 2017 Page 2 of 7

Another type of temporary heater has its combustion chamber and a heat exchanger located on a trailer outside the building (Photo 2). Both heated air and cooler return air are circulated from the trailer into the building by fans through flexible ducts. If this type of heater is properly maintained, it is unlikely that there will be any significant levels of CO inside the heated spaces. November 2017 Page 3 of 7

A third type of temporary heater locates the combustion chamber and heat exchanger inside the building, and vents the combustion chamber to the building s exterior (Photo 3). A fan circulates the interior air through the heat exchanger to warm the building. If this type of heater is properly maintained, it is unlikely that there will be any significant levels of CO inside the heated spaces. November 2017 Page 4 of 7

A fourth type of temporary heater is the torpedo heater, usually fueled with natural gas or liquefied propane (LP) gas. Photo 4 shows one of these heaters used to heat a scaffold enclosure so that masonry work may be completed in cold weather. In this arrangement, the heater draws its combustion air from outside the enclosure. The November 2017 Page 5 of 7

products of combustion (heat, carbon dioxide, and water vapor from the combustion of the hydrogen in the gas fuels) are discharged together into the bottom of the enclosure, rise upward through the enclosure, and are vented out the top through openings left in the enclosure. With a proper balance between heated combustion gases entering the enclosure at the bottom and venting from the top, it is possible to maintain good air quality inside the enclosure, with no more than a few parts per million CO present. The same effect can be obtained by locating the heater entirely inside the building or enclosure, and equipping the heater with a duct between outdoor air and the air intake on the heating appliance. This same type of torpedo heater can be used inside a larger building or enclosure, without a combustion air supply. Photo 5 shows one of these heaters drawing combustion air from inside the building and discharging its products of combustion into the same space. This recirculation of combustion byproducts to be used as an oxygen source for combustion gradually reduces the levels of oxygen inside the building to the point that the atmosphere is oxygen deficient, and CO forms. The inside of the building will also become very humid because of the moisture build-up and condensation from contact with cool surfaces. However, the CO levels are easy to keep low, by adjusting the amount of fresh air and exhaust ventilation openings in the building or enclosure. One midwestern state under OSHA jurisdiction has a local emphasis program for carbon monoxide in construction, which requires that the contractors monitor CO levels inside buildings and enclosures with temporary heat, or that have internal combustion engines running inside; and requires that the CO levels be maintained below the NIOSH November 2017 Page 6 of 7

REL of 35 ppm for an eight-hour work day. In the future, this program may become the rule for the six-state OSHA Region, and perhaps nationwide. Emergency responders must be aware that a dispatch to a construction job site for a worker feeling ill may be related to CO concentrations. They should be prepared to monitor the area for the safety of their own personnel. If the contractors are already monitoring CO levels and maintaining adequate ventilation for the heating appliances and processes that are present, that is a good thing. If no monitoring is being done, the emergency responders may be able to prevent their own illness, and the illness of more construction workers, by providing this simple and basic service. Gregory Havel is a member of the Town of Burlington (WI) Fire Department; retired deputy chief and training officer; and a 35-year veteran of the fire service. He is a Wisconsin-certified fire instructor II, fire officer II, and fire inspector; an adjunct instructor in fire service programs at Gateway Technical College; and safety director for Scherrer Construction Co., Inc. Havel has a bachelor's degree from St. Norbert College; has more than 35 years of experience in facilities management and building construction; and has presented classes at FDIC. November 2017 Page 7 of 7