INSTRUCTIONS! DO NOT DISCARD!

Similar documents
INSTRUCTIONS! DO NOT DISCARD!

INSTRUCTIONS! DO NOT DISCARD!

INSTRUCTIONS! DO NOT DISCARD!

WineZone Ceiling Mount Ductless Split 15

5+2 DAY. Digital Thermostat. residential. & 1-cool. up to 2-heat PROGRAMMABLE THERMOSTAT. Venstar Inc. 05/08

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

OWNER'S MANUAL T0140. Contents Page #

Non-Programmable Digital Thermostat

Owner s Manual Use with most Heat Pump systems: 1-Heat, 1-Cool 2-Heat, 1-Cool

Thermostat Remote Control & Receiver

MANUAL 8/12/05. Model BKP TM 100 INSTALLATION, OPERATION & MAINTENANCE. Commercial High Efficiency Heat Pipe Dehumidifier

WKS 2200 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

Installation Instructions

Humidity Module OWNER S MANUAL. Complete Control from

Publication # RD-0003-E Rev 1, 10/17 SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS

Split Floor-Mounted Cooling System Operation Care Installation Manual

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit

5+2 DAY. OWNER S MANUAL Venstar Inc. 05/08

2 - Wire Programmable Digital Thermostat

VENSTAR T1070 FAN COIL THERMOSTAT PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

DOLE REFRIGERATING COMPANY 1420 Higgs Road Lewisburg, Tennessee Phone (931)

Installation Instructions

Carrier NON-PROGRAMMABLE DIGITAL THERMOSTAT. Dual Setpoint Thermoglow Backlight No Batteries Required Auto Changeover Locking Keypad

User s Information Manual

Owner s Manual. Digital. Heat Pump. 5+2 Day Programmable. Model S1-THEH21P5S HVAC SERVICE PARTS TM

Wine Zone Ductless Split System

Installation Instructions

Programmable 5-2 Day Digital Thermostat

EBAC MODEL CD60 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

7-Day. Digital Thermostat. residential. & 2-cool

Programmable Digital Thermostat

user s information manual

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS

Programmable 5-2 Day Digital Thermostat

Ceiling Split Cooling System Installation, Operation & Care Manual WM-2500SSD WM-4500SSD WM-6500SSD WM-8500SSD

1 For All Programmable or Non-Programmable. Digital Thermostat. Meets Residential California Title 24

VENSTAR T1075 FAN COIL THERMOSTAT 7 DAY PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

EBAC MODEL KOMPACT INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Owner s Manual. Digital Thermostat. Heat/Cool & Heat Pump 7-Day Programmable S1-THEM22P7S COMMERCIAL. Model HVAC SERVICE PARTS

11,000 BTU Portable Air Conditioner with dehumidifier & Fan PE4-11R-03 Operating Instructions. Model No. PE4-11R Soleus Air International

Read and save these instructions

5+2 DAY PROGRAMMABLE DIGITAL THERMOSTAT

5+2 Day. up to HEAT COOL

COMFORT PACK INSTALLATION AND MAINTENANCE INSTRUCTIONS

Read and save these instructions

Enspeco RMS. The Enspeco Refrigerant Management. The following instructions will INSTRUCTIONS

EBAC MODEL BD-150 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

DOM MODEL SERIAL NUMBER VOLTAGE/HERTZ/PHASE

Horizontal Bottle Cooler Installation and Operation Manual

MODEL TSTATBBPB101 PROGRAMMABLE DIGITAL THERMOSTAT. Heat Pump & Heat Cool. Meets California Title 24 Residential USERS INFORMATION MANUAL

Owner s Manual Refrigerated Compressed Air Dryers Models F-3528, F-3529, F-3530, F-3531 & F-3532

Residential Duct Mount Builder s Box Media Air Cleaner

I2:00 Mo MODEL TSTATBBPB501 PROGRAMMABLE DIGITAL THERMOSTAT. Heat Pump & Heat Cool. Meets California Title 24 Residential USERS INFORMATION MANUAL

OWNER S Manual PRINTED IN CANADA 10/2009

Read and save these instructions

T-SERIES Air Conditioner. T62 Model INSTRUCTION MANUAL nvent Rev. F P/N

National Comfort Products 539 Dunksferry Road Bensalem, PA (215) Fax: (215)

SERVICING PROCEDURE R-410A LEAK TEST EVACUATION CHARGING. Bard Manufacturing Company, Inc. Bryan, Ohio Manual Page 1 of 11

INSTALLATION and OPERATION INSTRUCTIONS

Model BKP TM 750 Model BKP TM 750-AC Model BKP 1000 Model BKP 1000-AC Model BKP 1250 Model BKP 1250-AC

Split Wall-Recessed Cooling System Operation Care Installation Manual

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Quest Dry 150 Dual. quest Asset Protection and IAQ Solutions. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

National Comfort Products 539 Dunksferry Road Bensalem, PA (215) Fax: (215)

EBAC MODEL NEPTUNE INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

TC --- NHP, TC --- NAC Comfort Series Non---Programmable Thermostat. Owner s Manual

PROdry. High Inlet. Temperature. refrigerated. compressed air. dryers. Contents. For Sales & Service please contact:

GL-DEH Series Portable Dehumidifier Operating Instructions

CD85 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Horizontal/Side Discharge Condensing Units

1 For All Programmable Digital Thermostat. Meets Residential California Title 24

(PD[ $LU 'U\HU 5 ( ) 5, * ( 5 $ 7 ( ' 7 < 3 ( & ( 6 6 ( ' $, 5 ' 5 < ( 5 6 ('5&) ದ ('5&) Instructions Manual

INSTALLATION AND OPERATING MANUAL

Owner s Manual PRINTED IN CANADA 05/2009

TECHNICAL SPECIFICATIONS

Turbo Air Speed up the Pace of Innovation TBB-4SB CAUTION! PLEASE KEEP POWER SWITCH ON BEFORE OPERATING THIS EQUIPMENT

REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual

Model R060 Installation - Operation Manual

5+2 DAY INSTALLATION. Digital Thermostat. residential. & 1-cool. up to. 1-heat PROGRAMMABLE HEAT COOL HEAT PUMP THERMOSTAT. Venstar Inc.

Quest Power Electric Heat EHS 31 Pro

Air Conditioning Operation and Troubleshooting Matt Dunham

Commercial High-Efficiency Condensing Units

INSTALLATION INSTRUCTIONS

IMPORTANT SAFETY INFORMATION

Polar Air Dryer. Instructions Manual PDRCF PDRCF R E F R I G E R A T E D T Y P E C O M P R E S S E D A I R D R Y E R S

RHGN-H: COMMERCIAL AIR HANDLER WITH VARIABLE FREQUENCY DRIVE (VFD) NOMINAL 10 TONS R-410A REFRIGERANT 2-STAGE AIR-FLOW

Model No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions

Performance Non-Programmable Owner's Manual

MULTI HEAT PUMP PANEL CASSETTE TYPE DUCTLESS INVERTER INDOOR UNIT OWNER'S MANUAL. Models: CH12CC230VI CH18CC230VI CH24CC230VI

RPI Industries, Inc.

Quest Dry. Quest 110 Dual. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

Commercial High-Efficiency Condensing Units

InstructIon Manual KrEs EQuIPMEnt stands

A910.8A Remote Water Chiller, 8 GPH A A / A A-220V TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER:

CAH SERIES INSTALLATION & MAINTENANCE MODELS CAH CAH

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

Owner s Manual. Digital Thermostat. Non-Programmable

INSTALLATION & OPERATING INSTRUCTIONS FOR CEILING MOUNT AIR HANDLERS AC SERIES

CHEST FREEZER INSTRUCTION MANUAL. Model No.: EWCF5WBX EWCF7WBX

Transcription:

INSTRUCTIONS! DO NOT DISCARD! CAUTION! Do NOT install where injury might occur due to Moving parts, Sharp corners, Hot surfaces or electrical components d N0417 Page 1 of 10

INSTALLATION INSTRUCTIONS CAUTION This equipment should be installed only by a qualified technician. 1 Select a location for the evaporator coil. The Ideal location would be directly across from the entrance door. This will purge the entrance area when the door is opened, However since wine cellars are closed most of the time this is not critical. Mount the evaporator coil to the ceiling leaving a distance equal to the height of the unit, minimum, to the wall to allow for proper airflow. If you have a air handler system refer to the additional information supplied. Wall mount units require no additional space, except to ensure that air flow is not restricted. 2 Place the condenser at the desired location (air cooled condensers must be outside the wine cellar in a well ventilated area or outside). When installing an outdoor condenser be sure that it is located so snow or leaves will not pile up and block air flow. This can be accomplished by setting the condenser on concrete blocks Etc. 3 Install a line set sized according to the specifications for your unit. Insulate the vapor line the entire length of the run. Be sure to install P trap in the suction line, several may be required if the condenser is higher than the evaporator. 4 Connect your gauges and Vacuum Pump to the condenser and evacuate the system. 5 While the system is being evacuated, install the thermostat following the manufactures instructions and run the thermostat wire to the condenser unit, use the R and Y Terminal on the thermostat sub base, connect to the yellow and red wires in the condenser unit, if the system is an indoor unit use the R and G terminal on the control relay. On air handler systems refer to the drawing for that system. If possible, place the thermostat or sensor on the same wall as the evaporator coil near the evaporator air inlet. This will cause the thermostat to sense the air returning to the evaporator and should cool the entire room before the unit shuts off, Preventing compressor short cycling 6 Charge the unit with R22 according to the specifications for your unit (or until bubbles appear in the sight glass. Continue to slowly add Refrigerant until the bubbles just disappear). 7 After the unit has run about 10 minutes check the sight glass. Under normal operation there should be no bubbles, if there is, the system is low on Refrigerant, Add Refrigerant to eliminate bubbles. 8 When the wine room has reached 55 Degrees Check the sight glass again and the gauge readings. Suction pressure should be in the range of 65 to 78. Liquid pressure should be in the range of 250 to 300. Check the superheat ( which should be 8-15 ) and if necessary adjust the expansion valve to compensate. d N0417 Page 2 of 10

Installation of the indoor unit Mounting Installation Plate The indoor unit must be installed so that there is no short circuit of the cool discharge air with the hot return air. Please follow the installation clearance shown in the figure. Do not place the indoor unit in direct sunlight. Also this location must be suitable for piping and drainage and be away from the door or window. ROUTING OF PIPING The refrigerant piping can be routed to the unit in a number of ways (left or tight from the back of the unit) by using the cut-out holes on the casing of the unit (see figure). Bend the pipes carefully to the required position in order to be aligned with the holes. For right hand and rear side drawing out, hold the bottom of the piping and then fix the direction (see figure). The condensation drain hose should be taped to the pipes. Ensure that the wall is storong enough to support the weight of the the unit. Use the plumb line for horizontal mounting, and fix it with 4 suitable screws. If the lines are through the wall, drill a 65mm hole at the proper location. It should be slightly lower on the outside of the wall MOUNT THE UNIT ONTO THE INSTALLATION PLATE Hook the indoor unit onto the upper portion of the installation plate (engage the two hooks at the rear top of the indoor unit with the upper edge of the installation plate) To ensure that the hooks are properly seated on the installation plate, try checking by moving it slightly to left and to the right. 1. Hook the unit onto the installation plate. WATER DRAINAGE PIPING The indoor drain pipe must be downwards gradient for smooth drainage Avoid situations that are likely to cause water leaking. Check to see that there is a good flow of condensate water into the drain pan. 2. A unit support plate on the installation plate can be used to hold the unit slanted (see figure) to ease the piping installation work 3. Fix the screw underneath after completion of installation HORIZONTAL AIR FLOW CONTROL For more effective air circulation, you can manually adjust the air discharge grille to the left or right. d N0417 Page 3 of 10

d N0417 Page 4 of 10

11 7/16 2 41 5/16 35 3/16 Required Space for Service 2 4 d N0417 Page 5 of 10

Typical installation configuration for Split System With SLD Evaporator Power From Electrical Panel 220 Volt 15 Amp Wine Cellar SLD 3/8 Copper Liquid Line Evaporator Disconnect Indoor OR Outdoor Condenser Insulated 1/2 Copper Suction Line WineSmart SL Humidifier 2 wire Heater 2 wire Internet Cat5 Power to Condenser Thermostat 4 Wire OR Thermostat 4 Wire power to evaporator SL Thermostat d N0417 Page 6 of 10

Green Red Black Red Yellow R1 Compressor Contactor T1 230 vac - 24 vac Transformer FS1 Pressure Controled Fan Switch CH1 Crankcase Heater Wiring diagram 10,200 BTU R22 Outdoor unit Control Panel Located In Outdoor Unit Chassis Power Relay Coil Red Black 220 volt 24 VAC Orange FS1 Control Box Chassis CH1 C 1 Compressor Terminals 2 S R Red Yellow 1 2 M UP S L Start relay Condenser Fan Overload Black Start Capacitor 220 volt disconnect 15 amp MAX fuse size Evaporator 1 2 R G WineSmart-SL OR T8775-SL G R Y R1 T1 Condenser d N0417 Page 7 of 10

Wine Cellar Systems ALL PRODUCT LIMITED WARRANTY ONE-YEAR WARRANTY - This Wine Cellar Systems product is warranted to be free from defects in material and workmanship under normal use and maintenance for a period of one year from the date of purchase. A new or rebuilt part to replace any defective part will be provided without charge, Provided the defective part is returned to our factory shipping prepaid. The replacement part assumes the unused portion of the warranty. THIS WARRANTY DOES NOT INCLUDE LABOR or other costs incurred for repairing, removing, installing, shipping, servicing, or handling of either defective parts or replacement parts. WINE CELLAR SYSTEMS WILL NOT BE RESPONSIBLE FOR: 1. Normal maintenance. 2. Damage or repairs required as a consequence of faulty installation or application by others. 3. Failure to start due to voltage conditions, blown fuses, open circuit breakers, or other damages due to the inadequacy or interruption of electrical service. 4. Damage or repairs needed as a consequence of any misapplication, abuse, improper servicing, unauthorized alteration, or improper operation. 5. Damage as a result of floods, winds, fires, lightning, accidents, corrosive atmosphere, or other conditions beyond the control of Wine Cellar Systems. 6. Parts not supplied or designated by Wine Cellar Systems. 7. Wine Cellar Systems products installed outside the united states and Canada. 8. Any special, indirect, consequential, property, or commercial damage of any nature whatsoever. LIMITATION OF WARRANTIES - this warranty is exclusive and in lieu of all other warranties express or implied. The remedies provided for in this warranty are exclusive and shall constitute the only liabilities on the part of Wine Cellar Systems. In no event shall Wine Cellar Systems be responsible for any consequential damages of any nature whatsoever. FOR SERVICE OR REPAIR, FOLLOW THESE STEPS: First: Contact the installer. Second: Contact the dealer. Third: Contact: Wine Cellar Systems 6434 Canastota Drive. Hamilton, Ohio 45011 Ph: (513) 863-6596 Model No. Serial No. Date of installation d N0417 Page 8 of 10

Specifications SLD-10d Refrigerant Charge Liquid Line Suction Line Air Cooled R22 / R422b 4.6 Lbs 3/8 F 1/2 F Evaporator Evaporator Air Flow Max 360/403/480/572 CFM Sound Level Indoor 45 DB Evaporator Watts 65 Installed Size 41-5/16Wx11-7/16Hx9-3/8D Installed Weight Boxed Weight Condensor Outdoor Installed Size in 26.5 Lbs 31 Lbs 26x20x20 Installed Weight 125 lbs Boxed Weight 138.0 Fan CFM 600 Suction line Size Liquid Line Size 1/2 F 3/8 F Condensor electrical RLA/LRA 5.3 / 31.0 Nominal Voltage 208/230-60-1 Max. Fuse Size 15 Amp Min. Circuit Ampacity 7.7 Fan RLA 1.1 d N0417 Page 9 of 10

This page intentionally left blank L1205 Page 16 of 17

A Special Note To the Installer! If you would like your name to be added to our list of installers, Please fill out the following and mail or fax to Wine Cellar Systems 6434 Canastota Drive. Hamilton, Ohio 45011 Ph: (513) 863-6596 FAX (513) 863-6632 Job name Geographic Area that you are available for installations Company Name Address City State Zip Phone# FAX# Did you find our equipment Easy Hard Fair to install? Was the instructions Good Fair Poor Did you require additional information Yes No If you needed additional support what did it concern? d N0417 Page 10 of 10

Refrigerants Systems labeled R22 are capable of using any of the alternate R22 Class "A" refrigerants such as R422 If you prefer to tisc a refrigerant other than R22 we recommend using NLJ-22b (R422b) as it has R-22 like operating characteristics and is compatible with all standard ACR System Lubricants, i.e. MO, AB, and POE oils. Please refer to the P/T chart on the opposite side of this sheet Properly Label System: For your convenience we have included a NU-22B label If you have chosen another refrigerant Please avoid mixing refrigeranls by properly labeling your system. This System Contains NO Refrigerant! For additional information concerning NU-22b or to find a dealer near you www.icoriiucrnational.com

DATE: August 2009 REFERENCE DOCUMENT NO. RD-0003-E SERVICE GUIDELINES HCFC R22 to HFC REFRIGERANT BLENDS Figure 1, Pressure/Temperature Chart Temperature "F -40-30 -20-10 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 C -40.0-34.0-28.0-23.0-18.0-12.2-9.0-1.0 4.4 10.0 15.6 21.1 26.7 32.2 37.8 43.3 48.9 54.4 60.0 65.6 Pressure (PSIG) R22 0.6 4.9 10.2 16.5 24.0 32.8 43.1 56.8 68.6 84.1 101.6 121.4 143.6 168.4 195.9 226.4 260.0 296.9 337.4 381.7 R422A 3.1 8.3 14.6 22.1 30.9 41.4 53.5 67.5 83.5 107.3 128.4 152.1 178.6 208.1 240.9 277.1 317.1 361.2 409.7 463.2 R422B 0.9 5.4 10.7 17.1 24.7 33.6 43.9 55.9 69.6 85.3 103.0 123.0 145.4 170.4 198.2 229.0 263.1 300.6 341.8 387.1 R422C 2.2 7.1 13.2 20.4 29.0 39.1 50.8 64.4 80.1 97.9 125.4 148.7 174.7 203.7 253.9 271.5 310.8 354.1 401.8 454.2 R422D 2.4 7.1 12.9 19.8 27.9 37.5 48.5 61.3 75.9 92.6 111.4 132.6 156.3 182.8 212.2 244.7 280.7 320.2 363.7 411.4 R417A 4.2 1.5 5.9 11.2 17.6 25.1 33.9 44.2 56.1 69.8 95.7 114.0 134.5 157.3 182.6 210.6 241.3 275.0 311.7 - Dew Pt. Bubble Pt. Temperature F -40-30 -20-10 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 C -40.0-34.0-28.0-23.0-18.0-12.2-9.0-1.0 4.4 10.0 15.6 21.1 26.7 32.2 37.8 43.3 48.9 54.4 60.0 65.6 Pressure (kpa) R22 3.9 33.9 70.3 113.9 165.6 226.3 296.9 391.1 472.4 579.2 700.0 836.4 989.4 1160.3 1349.8 1559.9 1791.4 2045.6 2324.7 2629.9 R422A 21.4 57.2 100.6 152.3 212.9 285.2 368.6 465.1 575.3 739.3 884.7 1048.0 1230.6 1433.8 1659.8 1909.2 2184.8 2488.7 2822.8 3191.4 R422B 6.2 37.2 73.7 117.8 170.2 231.5 302.5 385.2 479.5 587.7 709.7 847.5 1001.8 1174.1 1365.6 1577.8 1812.8 2071.1 2355.0 2667.1 R422C 15.2 48.9 90.9 140.6 199.8 269.4 350.0 443.7 551.9 674.5 864.0 1024.5 1203.7 1403.5 1749.4 1870.6 2141.4 2439.7 2768.4 3129.4 R422D 16.5 48.9 88.9 136.4 192.2 258.4 334.2 422.4 523.0 638.0 767.5 913.6 1076.9 1259.5 1462.1 1686.0 1934.0 2206.2 2505.9 2834.5 R417A 28.7 10.6 40.9 77.3 120.9 172.6 233.3 304.3 386.2 480.7 659.2 785.2 926.4 1083.8 1258.1 1450.8 1662.5 1894.5 2147.8 - Dew Pt. Bubble Pt. 2009 Tecumseh Products Company. All rights reserved.