MODULAR COMPRESSED AIR PURIFICATION. ULTRAFILTER FRL.

Similar documents
AirCel. AG Aluminum. SH Steel. Industrial Filter Housings

DS Series. Ultraaqua Autoclean. Oil/Water Separators

High-Capacity Cycling Refrigerated Compressed Air Dryer. RTM Series

Refrigeration dryers DW 2-504

Membrane Dryer. Air inflow rate KMM Series to m 3 /min

CONDENSATE MANAGEMENT

Global Leader in Efficiently Treating Compressed Air EXCELLENCE IN DESIGN, MANUFACTURING AND SERVICE

UltraDry s Features and Benefits

Membrane Dryers KMM Series

Buran. Cycling Refrigerated Compressed Air Dryer With Ultrapulse Control. Intelligent Energy Management

Dryer Systems Heatless Regenerating Adsorption Dryers

HEATLESS REGENERATED ADSORPTION DRYER ULTRAPAC SMART

Dryer Systems Heatless Regenerating Purification Packages

Membrane Dryers KMM Series

SD Membrane Dryers Quality Air Solutions

3. What are the main parts in a compressed air generation? And list the flow path in order? 4. Draw the ISO symbol for an air compressor.

PNEUDRI High Efficiency Compressed Air Dryers

UltraPleat Technology BURAN REFRIGERATION COMPRESSED AIR DRYER

AirCel. Cycling Refrigerated Compressed Air Dryers. RFC and DVF Series

PNEUDRI High Efficiency Compressed Air Dryers.

VarioDry SPN

Chapter 9: The basics of air preparation

Atlas Copco. Quality Air Solutions SD Membrane Dryers

High quality compressed air from generation to application

BURAN REFRIGERATION COMPRESSED AIR DRYER. UltraPleat Technology

Compressed air preparation Compressed air storage Moisture management. Catalog #1

Adsorption Air Dryers

Rust, corrosion and leakages threaten even the best network. Only Quality Air Solutions. in optimal shape. air distribution

Adsorption Dryers. AD 7 to 1300

Dryer Systems Heatless Regenerating Adsorption Dryers

20 21,250 SCFM GLOBAL AIR TREATMENT. FIL Series

Dryer Systems Heatless Regenerating Adsorption Dryers

Downstream Equipment. Intelligent Air Technology

Adsorption Dryers. AD 7 to 1300

CLEARPOINT THE WINNING COMBINATION FOR CLEAN COMPRESSED AIR

AirCel. Heated Regenerative Desiccant Dryers. AEHD Externally Heated, HRE Blower Purge, and HRS-L Zero Purge Series

SYNRAD Technical Bulletin # 0015d

Atlas Copco Quality Air Solutions. SD Membrane Dryers

Dryer Systems. Breathing Air Units

FACT SHEET 3. Efficient Compressed Air Treatment. How to save energy, reduce costs and help the environment

ADSORPTION DRYING: WHY?

Compressed Air. Filtration. Balston Membrane Nitrogen Generators. 157 Parker Hannifin Corporation

PET Drying Technology

F-H Refrigerated Dryers

CMMD Series Membrane Air Dryer

ultra-high purity compressed air dryers flow capacity: scfm ( Nm 3 /hr)

Pneumatech: Your guarantee of highquality. air and gas

ULTRAPAC SMART ULTRAPAC SMART INDUSTRIES

BOGE AIR. THE AIR TO WORK. Refrigerant Dryers RA Series

Spiralair SPR 2-30 TECHNOLOGY YOU CAN TRUST

Refrigerant air dryers. FD series ( l/s, cfm)

industry revolves around VMMD Series Membrane Air Dryer

Refrigeration dryers DW 2-504

Desiccant Air Drying Technologies HCS Series HCL Series HCT Series

Membrane Technologies DMD Series Dryers ESM Series Dryers

Thermo Scientific Model 1160 Principle of Operation

The Highest Quality Compressed air treatment Refrigerant dryers CFM 0.33 to 91.1 M/min

Ingersoll Rand. Heatless and Heated Blower Desiccant Air Dryers ,900 m 3 /hr

Oil / Water Separators Ultrasep Superplus N and Ultraaqua Autoclean

Adsorption Dryers for Compressed Air

Desiccant Air Dryers. ABP Series. Blower Purge Desiccant Air Dryer 70-8,000 scfm

Filters & Centrifugal Separators

Your compressed air - Our know-how Components and engineered systems for compressed air and gas treatment

TECHNICAL BULLETIN SELECTING A COMPRESSED AIR DRYER INTRODUCTION

Desiccant Dryers DC Series (Heatless regenerated) Air flow rates 0.15 to m³/min.

ThermoStar Refrigeration Air Dryers

Efficiency in the smallest space

Permission granted to reproduce for educational use only. Describe the problems caused by excess

Atlas Copco. Heat-of-compression rotary drum dryers ND series ( l/s, cfm)

P3X Series Membrane dryers

ingersoll rand desiccant dryers

Meeting Your Compressed Air Treatment Needs

VARIABLE SPEED DIRECT DRIVE CENTRIFUGAL AIR BLOWERS

ARV -3 & ARV -10 Active Reservoir Vent Installation and Operation Manual

Heat Les Desiccant Compressed Air Dryers. DSE Series DSS Series DHD Series

Refrigeration Compressed Air Dryer Boreas Variopulse

Cyclonic Separator. Condensate Separator. No Air Loss Drain. Condensate Management. People. Passion. Performance.

COMPRESSED AIR TREATMENT COMPRESSED AIR DRYER

Adsorption Dryers. DB 05 to 130

DENTAL AIR. LFx LF SF Class 0 clean air compressors. Atlas Copco dental compressors - 1

HEAT REGENERATED ADSORPTION DRYERS

HIGH QUALITY COMPRESSED AIR FROM GENERATION TO APPLICATION A GUIDE TO THE ISO 8573 AND ISO SERIES OF COMPRESSED AIR QUALITY STANDARDS

QUINCY QPNC SERIES NON-CYCLING QUINCY QRHT SERIES HIGH TEMP

CDX Refrigerant dryers


PNEUDRI MiDAS - Mini Dry Air System

Membrane Drying DRYPOINT MD. space saving compressed air membrane dryers. Truth in Compressed Air.

CDT Series MCGUIRE AIR COMPRESSORS INC MCGUIRE AIR COMPRESSORS INC Heatless Desiccant Air Dryers 40 5,400 SCfm

Compressed air treatment for applications up to 2,500 m³/h and 16 bar

Rev. None AUGUST 2012 MDM SERIES MODULAR MEMBRANE AIR DRYERS OPERATOR MANUAL MDM1 MDM4 MDM9 MDM13 MDM24 MDM49 MDM66 MDM106 MDM138

Application report. Compressed air treatment at a beverage industry plant. Food & beverages. Industry:

Adsorption dryers PDAD

PNEUDRI MiDAS A totally clean and dry compressed air system (CDA)

Refrigerated Air Dryers VF Series. DHT Series. Non-Cycling 10-2,000 scfm scfm

Compressed Air Filters

HEATLESS DESICCANT AIR DRYERS

Dual Tower Heat Reactivated Desiccant Air Dryer

SR Series Refrigerated Dryers SCFM

Atlas Copco Adsorption Air Dryers. MD l/s / cfm

Nitrogen Generation Systems Compressed Air Dryers

Transcription:

MODULAR COMPRESSED AIR PURIFICATION. ULTRAFILTER FRL.

ULTRAFILTER FRL-UNITS. THE INTELLIGENT AND COMPLETE PURIFICATION SOLUTION. A Contribution to Energy Saving The introduction of Quality Air (Filter, Regulator, Lubricator) program establishes a quality standard for compressed air purification in industrial pneumatic applications only Ultrafilter can offer. An important fact for all users of compressed air since it now allows to make use of the Ultrafilter quality and performance in the FRL sector as well not only reducing the number of suppliers but also guaranteeing a constant high quality level of this important power source from generating to the point of use, typically Ultrafilter. The almost unlimited possibilities in combining and varying the single Ultrafilter FRL components are pointed out best by having a close look at the single steps of the compressed air purification process. No matter what quantity of compressed air needs to be treated only the quality demands determine the components of your purification equipment. With a centralized purification device the entire compressed air generated has to be purified to meet the quality demands of the most sensitive application regardless of the fact that this only consumes % or even less of the air. Local compressed air treatment with Ultrafilter FRL-units supplies each individual application exactly with the air quality required and therefore avoids costly super qualification of compressed air for low demand purposes. Modular Compressed Air Purification with integrated dryer: VarioDry FRL 3 5 Filter-Water-Separator with cyclone system and filter element, filter element available in different pore sizes Submicrofilter equipped with Ultrafilter filter element Ultrair SMF 3 Membrane Compressed Air Dryer Ultratroc VarioDry FRL with integrated purge air nozzle and internal regeneration air duct Pressure Regulating Valve and Pressure Gauge for outlet pressure visualization, handwheel lockable 5 Activated Carbon Filter equipped with Ultrafilter filter element Ultrac AK

Depth filter element series Ultrair Packages The single Ultrafilter FRL components are designed to match perfectly with the VarioDry FRL membrane dryer in terms of airflow and connection size. No matter what purification solution is required Ultrafilter always offers the optimized combination for the individual application. A Look Inside: High Efficiency Filter Element The next important step on your way to a compressed air purified exactly to the individual requirements is filtration. Depending on inlet as well as outlet parameters filtration can be designed purely as a one-stage FRL component but also up to a several-stage maximum retention device. Ultrafilter supplies an optimally tailored solution for every application: from coarse dust filters up to submicro filters. They all do an extremely reliable and economical job in cleaning your air from oil, water and particles by their Step by Step the Purification Process The Ultrafilter FRL purification chain starts with a Filter-Water-Separator. It retains bulk particle contamination by a sieve effect and contains a cyclone separator to remove water and oil droplets from the compressed air. The Filter-Water-Separator prevents the following high efficiency filter from bulk contaminants, and therefore avoids pollution related problems like short overall lifetime or high differential pressure. Filter-Water-Separators are available in different pore sizes high capacity constant high efficiency superior dirt retention capacity minimized differential pressure optimized economy highest reliability Particularly the high efficiency Ultrair microfiber fleece guarantees an optimal threedimensional depth filtration ensuring highest load as well as dirthold capacity. Three stage filter combination to ensure the optimum filtration result 3

Superior Concept: Integrated Membrane Dryer The integration of a dryer in the FRL-unit itself offers some major advantages like Tuned to form a complete package No additional fittings required Identical housing design guarantees lowest differential pressure No danger of leakage since external adapters or interconnecting devices are not used Air coming from the prefilters enters the integrated dryer and is fed through the center of a bundle of hollow fibers with semi-permeable membranes. Moisture diffuses across the semi-permeable membrane as air moves through the centre of the hollow fiber bundle. The dry air produced leaves the system in order to drive the application or to enter the next purification step respectively with a portion of it fed back over the outside of the fiber bundle and vented to atmosphere via outlets. A throttle nozzle controls the continuous volume of sweep or purge air. No condensate is generated during the drying process since dehumidification takes place in the gas phase completely. Performance of the integrated membrane dryer for a given application will be a function of inlet conditions to the system. Varying inlet conditions will produce varying outlet conditions, although a discrete Pressure Dew Point (PDP) reduction within the dryer takes place. FRL SUPERPLUS. DRY COMPRESSED AIR. Leaving the last filtration stage the compressed air is free of dirt particles oil and water but far away from being dry. A temperature drop of only 3 F will result in water vapor condensing again a fact which cannot be prevented by any filtration technology. The reason behind is the natural process that air at a relative humidity of 00% condenses and water is set free with falling temperatures of the air. A fact that illustrates best the necessity of a FRL integrated dryer because only drying the air reliably prevents condensate from forming downstream of the filters. All FRLunits benefit from Ultrafilter s long-standing experience in manufacturing air dryers.

Bundled Advantages Membrane Dryer VarioDry FRL The use of a membrane compressed air dryer integrated in the Ultrafilter FRL-unit combines several unique advantages in a single device: almost silent operation allows direct workshop installation no power supply required inherently safe device, applicable in hazardous areas no oxygen depletion, suitable for breathing air applications Heart of the Dryer: Module with the hollow fiber bundle. Cross section of hollow membrane fibers: Cross section of the hollow membrane fibers. Taken with extreme magnification by means of a scanning electron microscope. The membrane wall thickness is approx. 50 micrometer. Relation between inlet airflow (as percentage of nominal airflow) and Pressure Dew Point Reduction realized. VarioDry FRL Airflow % Pressure Dew Point Reduction F 5

PURIFICATION DOES NOT END WITH DRYING... The compressed air leaving the dryer is treated to a quality level high enough to Always the Right Pressure The previous phases described in the purification process with FRL-units allow to supply each application with the required compressed air in terms of purity and dryness. But all this does happen on a working pressure level supplied by the compressor station to the complete compressed air system. ensure a smooth production process without downtime. This statement describes the situation of most applications correctly, however there is a high number of situations where experience and practice proves that clean and dry air alone simply is not sufficient. In addition to application related individual circumstances the reasons behind can usually be divided into two classes. At first not each individual application can operate on the working pressure generated in the central compressor station and secondly there is a wide range in the demands regarding the residual oil content of the dried air. Pressure Regulating Valve (Diaphragm type) fitted with pressure gauge The use of a pressure regulator contributes to the ideal purification solution by enable the optimal tuning to the requirement of the pneumatic device eliminates the transmission of pressure shock waves guarantees the exact observation of a maximum pressure limit optimal use of larger flow capacity for prefilters and dryer with higher operating pressure ensures that pressure related processes can run at constant conditions 6 No Bitter Aftertaste Of course the results of compressed air still containing oil vapor and aerosols are not in all branches as dramatic as in the food and beverage industry where not only taste but health is a major concern as well. But for many other applications the fact applies as well that oil components in the air which were not removed completely can cause trouble. Even with non-oil lubricated air compressors you will find oil in the compressed air a consequence of polluted ambient air used for compression. This leaves the purification equipment with the job to ensure that oil vapor is removed and the danger to health is minimized reliably. The guarantee for oilfree compressed air is the Ultrafilter Ultrac AK activated carbon filter capturing all gaseous hydrocarbons in an exceptionally intensive two-stage adsorption process patented by Ultrafilter. Only an Ultrafilter activated carbon filter ensures that purification as well as protection requirements are met and only a FRL-unit comprising an AK filter is to be regarded as complete purification station for oilfree air in the true sense of the word. Activated carbon filters guarantee comprehensive product protection and customer care Ultrafilter Oil Mist Lubricator and everything will work out fine Usually pneumatic cylinders and actuators depend on a constant amount of lubricated compressed air in order to do their job with the required precision and repeating accuracy. Therefore these components used in a number of industrial applications have to be supplied with a defined quantity of oil only the Ultrafilter oil mist lubricator can offer. By adding a lubricator to the FRL-unit the reliable and accurate function of the components is ensured as well as it contributes to prolong the life span of the pneumatic devices.

Purification unlimited Purification brought to the top that simply is the essence of the Ultrafilter FRL program. This does not only refer to the fact that air which has been treated completely fulfills even highest quality demands but also points out that decentral air Different bowl materials allow adaptation to distinct applications and environments treatment represents the state of the art technology offering the purification optimum for each individual application. The Ultrafilter philosophy expressed in the FRL series is best described simply: compressed air as clean as necessary and at a highly cost-effective pricing. Accessories and Options Although the removal of oil vapor and aerosols symbolizes the highest purification level it does not simultaneously represent the end of opportunities. There nearly is no limit to the variability and possibility of combining the single components of the Ultrafilter FRL program. Additionally the accessories or the combinations respectively really complete the individual unit. Besides the tuning to the individual requirements these components virtually enhance functionality, user-friendliness as well as easy operation to perfectly match with the single application. This ensures the optimal solution to meet each request perfectly there is no reason to accept anything less any longer. Intelligent Combinations The modular FRL system of Ultrafilter simply offers the user more more flexibility and more individuality hence the system guarantees one component to fit with the next. Nevertheless Ultrafilter has adapted customer needs and developed several components which already combine more than one feature in a single housing. Filter-Regulator including pressure gauge A filter-regulator does not only minimize space requirements compared to two separate units. It also reduces investment costs and additionally ensures that the filtration downstream always operates at a constant pressure and therefore with a defined performance. This illustrates that individual requirements are met best by individual solutions which might well result in a combination with all the advantages and benefits described above. Ultrafilter FRL-units offer maximum advantages at minimum investment costs. Ball-valve operated Shut-Off Device FRL-unit comprising a combination and two single FRLcomponents 7

Explanations: Airflow related to intake state of the air compressor (68 F,.5 psi); working pressure 00 psi gauge, inlet temperature 00 F, inlet Pressure Dew Point 00 F according to CAGI ADF 00 reference conditions. Performance data given refer to a PDP reduction of 0 F and a regeneration airflow of 0%. Operating parameters: Ambient temperature min. 35 F, max. 0 F; working pressure min. 70 psi, max. 50 psi, permissible pressure and/or temperatures may vary in combination with distinct FRL accessories. Technical alterations reserved. Quality guaranteed A company grows according to the challenges that are set. And according to the quality standard which it sets itself. We were the first to be awarded the DQS certificate in accordance with DIN ISO 900. For a constant quality standard in every single department of the company. Ultrafilter customers always receive intelligent products and systems representing state of the art technology. Premier quality goals combined with innovative technology enable system solutions of highest economic efficiency and reliability. All components are tuned to match with each other. In addition to a functional guarantee all Ultrafilter customers can rely on the compressed air quality process security made by Ultrafilter. TECHNICAL DATA. MEMBRANE DRYER. VARIODRY FRL. Model SF 000-60 SF 0003-60 SF 0006-60 SF 0008-60 SF 000-60 SF 005-60 SF 000-60 SF 0030-60 SF 000-60 SF 0050-60 SF 0060-60 SF 0070-60 SF 0085-60 Model SF 000-60 SF 0003-60 SF 0006-60 SF 0008-60 SF 000-60 SF 005-60 SF 000-60 SF 0030-60 SF 000-60 SF 0050-60 SF 0060-60 SF 0070-60 SF 0085-60 cfm.5 3 6 8 0 5 0 30 0 50 60 70 85 Inlet Airflow Width inches 3 3 5 5 6 9 3 3 SF 000 005 SF 0035 000 W D H W D l/min. 83 67 50 333 7 583 833 083 333 667 080 500 Connection Height inches 3 9 8 8 8 8 8 R / / / / / / / / Product range Weight Ib..5 5.5 7 7.5 8 8 5 7 35 3 8 8 Depth inches Adsorption dryers: Ultrapac 000 (3 60 cfm) High-capacity-filters: Standard (3,500 cfm) Superplus Compressed air fridge dryers: BURAN 6,000 cfm) BOREAS (,00 7,00 cfm) BRISA (as from 5,500 cfm) Compressed air membrane dryers: VarioDry Classic ( 9 cfm) Condensate drain: Ultramat Ultrasep (75,000 cfm) Donaldson Company, Inc. Ultrafilter 3560 Engineering Drive Norcross, GA 3009 00 Bulletin No. UFSB0 Toll free: 800.53.363 Telephone: 770.8.3363 Telefax: 770.8.385 E-mail: ultrafilterinfo@mail.donaldson.com Web: www.donaldson.com