FIRE AND SAFETY PROJECT REVIEW REPORT

Similar documents
FIRE SAFETY REQUIREMENTS FOR PRE RESIDENTIAL BUILDINGS OF THREE OR MORE STORIES (DOROTHY MAE ORDINANCE - NO. 158,963)

Moreno Valley Fire Department Fire Prevention Bureau. New and Existing Fire Alarm & Signaling Systems Guideline

Building & Fire Code Academy. Building Better With Our Greatest Resource Education. Welcome!

SANTA CLARA COUNTY Winchester Blvd., Los Gatos, CA (408) (408) (fax)

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

DONALD H. BERG, ARCHITECT

FIRE & LIFE SAFTEY STANDARD

2018 IFC Update. Based on the 2018 International Fire Code, (IFC ) Goal. Objectives. Content

Fire Sprinkler Plan Submittal Form

POLICY NUMBER ISSUE DATE REVISED DATE REVIEW DATE

HIGH-RISE RETROFIT ORDINANCES - NO and NO

Agency for Health Care Administration

Valuation: # of Plans Submitted: # of pages: Type of Work (select one): New Addition Existing System/Modification Project Name: Scope of Work:

International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures

Recommended Amendments to the 2015 International Existing Building Code North Central Texas Council of Governments Region

Public. Mike Free Health. State of Alabama Department of

Public Health Fax: Web Site:

Are there any policies regarding outlets that contain USB ports?

M E M O R A N D U M. NFPA 5000 A2011 ROP Letter Ballot

Other EC and LS documents may be requested by surveyors, as needed, throughout the survey.

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry

Plan Review Check List Fire Alarm System

Taming the Health Care Building Codes NFPA vs. The International and Chicago Building Codes JENSEN & HALSTEAD LTD.

SECTION FIRE ALARM STANDARDS REVISED CONSTRUCTION STANDARD

Health Chapter ALABAMA STATE BOARD OF HEALTH ALABAMA DEPARTMENT OF PUBLIC HEALTH ADMINISTRATIVE CODE

El Reno Fire Department Fire Alarm Plan Review Worksheet

NFPA 101, 2012 EDITION IMPACT ON NEW AND EXISTING HEALTH CARE FACILITIES

FIRE INSPECTORS GUIDELINES FOR PLAN REVIEWS AND INSPECTIONS OF NEW CONSTRUCTION / ADDITIONS AND CHANGE OF OCCUPANCY

5123: information. The graphic plan shall include, but may not be limited to: (a) A primary and secondary means of exit from each floor;

Changes to the 2018 Joint Commission Comprehensive Accreditation Manual for Hospitals (CAMH)

ADDENDUM NO. 1. for. MARQUETTE HOUSING COMMISSION Pine Ridge Apartments Fire Alarm Replacement Project #A1140. Marquette, Michigan.

LIFE SAFETY & FIRE PREVENTION MANAGEMENT PLAN

9/20/2016 2:53 PM. Second Revision No NFPA [ Section No ] Supplemental Information. Submitter Information Verification

FACILITY MANAGEMENT DEFICIENCIES IN CRITICAL ACCESS HOSPITALS (CAH)

2. HVAC and smoke control systems; fire, smoke, and combination fire/smoke dampers. 5. Central control and monitoring system.

SAF-BCF SECOND REVISIONS WITH STATEMENTS

PROPOSED CODE CHANGES FOR REVIEW BY THE FIRE CODE ACTION COMMITTEE

Agency for Health Care Administration

FACILITY MANAGEMENT DEFICIENCIES IN ACUTE CARE SETTINGS

Brighton Area Fire Authority

Fire Protection Coffee Break Training May 2016

Review of Revisions to NFPA 1, 2015 Edition

Agency for Health Care Administration

Electronic Safety and Security

FIRE INSPECTION GUIDELINES FOR FOSTER GROUP HOME PARENTS Effective June 1, 2002, Update September 2011

Commercial Application/Plan Review Submittal Checklist

Residential Care Facilities Requirements

WEST VIRGINIA UNIVERSITY

DIVISION 26 ELECTRICAL SECTION FIRE ALARM SYSTEM

BCBC 2012 CHANGES TO PART 3

Changes to Environment of Care, Equipment Management, and Life Safety Chapters Related to Life Safety Code Updates

Fire Alarm, Water Flow Alarm & Signaling Systems

DESIGN GUIDELINE SBA 5.11

2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge.

NFPA 101 Code Update from 2012 Edition to the 2015 Edition

Residential-based Care Facility R-4 Guideline

Chapter 2: Definitions

Report on First Revisions with Statement June 2014 NFPA 101

EC 5.10 FIRE PREVENTION MANAGEMENT

Commercial Remodel/ Add On Rules and Regulations

MANUAL OF DESIGN CRITERIA AND SPECIFICATIONS FOR FIRE DETECTION AND ALARM SYSTEMS PUBLIC SCHOOLS IN NEW MEXICO

CHAPTER 61G15-32 RESPONSIBILITY RULES OF PROFESSIONAL ENGINEERS CONCERNING THE DESIGN OF FIRE PROTECTION SYSTEMS

12/14/2013. Fire alarm and emergency power SPRINKLER HEAD

D. The work addressed in this section consists of a fire protection system, which may include coordination with one or more of the following:

Montgomery County Government Building and Codes Department 350 Pageant Lane, Suite 309 Clarksville, TN 37040

2015 Recommended Building Code with Amendments. The Executive Committee of the Central Iowa Code Consortium does ordain as follows:

LIFE SAFETY COMPLIANCE: ADAPTING TO THE 2012 LIFE SAFETY CODE

9/23/ :20 AM. Second Revision No NFPA [ Section No ] Supplemental Information. Submitter Information Verification

Riverside County Fire Department Office of the Fire Marshal Market St., Ste. 150, Riverside, CA Ph. (951) Fax (951)

AD HOC HEALTHCARE COMMITTEE MEANS OF EGRESS WORK GROUP APPROVED CODE CHANGE DRAFTS CODE GROUP B MOE COMMITTEE

10/28/2015. Enjoy Your TJC Survey. Bill H. McCully CHFM SASHE. Senior Consultant MSL Healthcare Partners. MSL Healthcare Partners, 2015 PREPARATION

Clark County Department of Building & Fire Prevention 4701 West Russell Road, Las Vegas, NV (702) FAX (702)

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST

Established /10/2015. Doran Pruisner Dan Wood

H BUTCH BROWNING FIRE MARSHAL BUILDING REHABILITATION

Agency for Health Care Administration

1. Floor above/floor below notification. 2. Private alarm notification. 3. Not Used 4. Voice alarm notification. 5. Not Used.

FIRE SAFETY MAINTENANCE INFORMATION for Agricultural Livestock Structures

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

Rancho Cucamonga Fire Protection District Prevention Bureau Standard

CITY OF LONG BEACH Department of Development Services BUILDING AND SAFETY BUREAU FIRE ALARM / ELECTRICAL FIRE PLAN REVIEW CHECKLIST

Minimum Standards for Engineers Practicing Fire Protection Engineering in the State of Oklahoma September 14, 2016

SPRINKLER PROTECTION OF COMBUSTIBLE CONCEALLED SPACES WITH LESS THAN 6 BETWEEN OPPOSITE FACES IN CAVITY.

Large Family Daycare Guideline

E25 (D) Automatic controls for general means of egress lighting

New Construction Fire Inspection Process

Design & Construction Standards, Revised January

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

BUILDING CODE OF THE CITY OF NEW YORK. New York City Department of Buildings 4 June 2007

Agency for Health Care Administration

MECKLENBURG COUNTY FIRE MARSHAL S OFFICE

STATE FIRE MARSHAL S REQUIRED FIRE PROTECTION SYSTEMS NARRATIVE REPORT

Residential Based Care Facility Guidelines

IMO UNIFIED INTERPRETATIONS TO SOLAS CHAPTER II-2 AND RELATED FIRE TEST PROCEDURES

2007 CBC & CFC Residential Care Facility Requirements (24 hour care only)

DEALING WITH FIRE SAFETY

SECTION FIRE DETECTION AND ALARM

For additional information regarding R-3.1 residential care facilities please contact (951)

Full Service Central Station Fire Alarm Listing Evaluation

I. Scope: II. Environmental Health and Safety Fire Alarm System Impairment Program - Guideline Revision Date: April, 2018

Transcription:

1. A001 2. A001 3. A001 4. D102/103 5. A102/103 *VA enforces/applies the National Fire Protection Association (NFPA) 101 (current edition is 2015) and not the International Building Code (IBC). Ideally all references should be to NFPA 101 and not IBC. Note: There are no differences between NFPA 101 and IBC for the life safety and fire protection features affected by this project. The codes analysis indicates there is a 1-hour occupancy separation between the assembly occupancy (chapel) and the business occupancy comprising the rest of the floor. This separation is only required if there is an intent to provide separate egress facilities for each occupancy type. The 1-hour barrier shown on drawing A103 does not include the means of egress for the chapel within the separated portion of the building. While Stair 6 could be included within the separated area by the relocation of the rated wall, this would only include one means of egress while two are required. Incorporation of a second stairway within the separated assembly occupancy appears impractical; it is not required as the building appears to be code compliant if the design intent is a non-separated or mixed occupancy. Revise the codes analysis to reflect the mixed-use concept or revise the occupancy separation to provide a code compliant means of egress within the assembly occupancy. All means of egress doors from the chapel must swing out since the occupant load exceeds 50. Note: Only one of the two single doors is needed as a required means of egress presumably the door in the east wall. Indicate rated walls (the stairway, elevator, and elevator machine room appear to be the only rated walls) to ensure proper firestopping of any penetrations and use of rated infill. Indicate rated walls (the stairway, elevator, and elevator machine room appear to be the only rated walls) to ensure proper firestopping of any penetrations and use of rated infill. VA Fire Protection Design Manual (FPDM), Paragraph 1.3.B Section 6.1.14 Paragraph 7.2.1.4.2 Revisions include references to NFPA 101 codes Revisions include references to NFPA 101 codes Door on east wall now swings out and decorative paneling in chapel has been modified to reflect change. Existing rated walls now indicated. Existing rated walls now indicated. Page 1 of 5

6. A103 7. Fire extinguisher cabinet 8. E-101 9. E-101 10. E-310 All means of egress doors from the chapel must swing out since the occupant load exceeds 50. Note: Only one of the two single doors is needed as a required means of egress presumably the door in the east wall. At least one fire extinguisher is needed within the project area; no fire extinguisher cabinet was observed and presumably is needed. Note: A specification section for fire extinguisher cabinets is provided. Paragraph 7.2.1.4.2 Provide an exit sign over the single door in the east wall as a second means of egress that must be designated from the chapel. Paragraph 13.2.10.1 *Recommend the provision of emergency lighting in the chapel. Note: While Life Safety Code, Paragraph 13.2.9.3 allows for omission of emergency lighting in this small chapel, it is still an area that will be used by patients and visitors unfamiliar with the chapel. There is also potential for the seating arrangements to be modified at any time since seating is not fixed. If the resolution of Item 2 results in deletion of the 1-hour wall at the chapel, then the smoke detectors and door hold-open devices at the main chapel doors should be deleted, because this will no longer be a rated door and a mechanical hold-open device is adequate to keep the doors open when desired. Door on east wall now swings out and decorative paneling in chapel has been modified to reflect change. (4) are provided. Refer to 3/A120 in corridor 397 between column grid H.9 & K, 2/A120 in Locker/Break 351C @ Column Grid F, 1/A120 in Corridor 397 between C & D, & in Chapel 349 between column line B & C. Concur An exit sign has been added above the single door (second exit) from the Chapel. Melissa D. Meade, Fire Protection Engineer, Woolpert Concur Emergency lighting has been added to the Chapel since this space has an occupant load greater than 50 persons and will be used by visitors. Melissa D. Meade, Fire Concur The 1-hour separation for the Chapel has been removed from the design. Therefore, the door hold open devices and associated smoke detectors have been removed from the fire alarm plan at the Chapel double door. Melissa D. Meade, PE, Fire Page 2 of 5

11. E-310 12. E-501 13. E-501 14. E-501 15. M103 Notification appliances are not required in individual offices unless the occupant is known to be hearing impaired. Coordinate the designation of the new panel to house the new cards, amplifiers, batteries, and battery charger; on Drawing E-310 the designation NAC is used, while on this drawing it is called an RPS. Paragraph 7.3.F.1.b(1) Delete the return air duct detector since the air handler serves only one floor. NFPA 90A (2015), Paragraph 6.4.2.1(2) If the resolution of Item 2 results in deletion of the 1-hour wall at the chapel, then the smoke detectors and door hold-open devices at the main chapel doors should be deleted, because this will no longer be a rated door and a mechanical hold-open device is adequate to keep the doors open when desired. Delete the fire dampers shown on the ducts entering chapel. Even if the 1-hour rated wall is retained, NFPA 90A does not require fire dampers on walls with less than 2-hour rating, and VA does not follow IBC/IMC for fire protection. NFPA 90A (2015), Paragraph 5.3.1.1 Non-Concur It is our understanding that the VA would prefer to maintain an environment that is ABA/ADA ready to avoid having to make system modifications in the future. There are only three single office rooms (Office 349E, Office 349F, and Office 349H). Therefore, the strobes will remain in these rooms in order to achieve future flexibility to have this office available to an occupant with hearing disabilities without having to do future system modification. Melissa D. Meade, PE, Fire Concur The notation has been coordinated to Notification Appliance Circuit (Remote Power Supply) on the floor plan, legend, and riser diagram. Melissa D. Meade, PE, Fire Concur The return air duct detector has been removed since the air handler RTU only serves this one story. Melissa D. Meade, Fire Concur - The 1-hour separation for the Chapel has been removed from the design. Therefore, the door hold open devices and associated smoke detectors have been removed from the riser diagram. Melissa D. Meade, PE, Fire Protection Engineer, Woolpert Page 3 of 5

16. FP001 17. FP001 18. FP001 19. FP102 20. FP102 Provide water supply information on the drawing or in the specification. The contractor is only required to perform a water supply test if the information provided in the contract documents is more than 12 months old at the time the contractor develops hydraulic calculations. Add a third sprinkler shutdown option allowing sprinkler shutdowns while the contractor provides fire watch in the affected areas in accordance with medical center interim life safety measures requirements. Remove references to fees and the review/approval of sprinkler plans by the fire marshal or fire department. VA approves all submittals, which may be delegated to A/E. Modify Note 1: VA policy does not permit use of concealed sprinklers (this room is not covered by any of the exceptions). Note: If clearance is an issue, consider the use of sidewall sprinklers. Modify Notes 2 and 3 to indicate that sprinklers shall be replaced in the new location (sprinklers cannot be removed and reinstalled). Page 4 of 5 Paragraph 6.1.G Paragraph 6.1.G NFPA 13 (2016), Paragraph 6.2.1.1 Concur A copy of the most recent fire pump test received from the VA has been added to sheet FP001 along with a note stating that the contractor is responsible for obtaining or performing water supply testing within 12 months to use in the hydraulic calculations. Melissa D. Meade, Fire Non-Concur The two options listed for construction period safety were specifically developed by the VA and provided to the design team. Therefore, this third option will not be included. Melissa D. Meade, Fire Concur References to fees and review/approval by the fire marshal or fire department have been removed. Notes 1 and 26 have been deleted. Melisa D. Meade, Fire Non-Concur Per specific direction by the VA, the concealed sprinklers shall be used in the Dishwashing area only. Currently the existing sprinklers in the Dishwashing room are concealed heads. Additional notes have been added to the plans to clarify that concealed heads are permitted in Dishwashing area only. Melissa D. Meade, Fire Concur Note 2 and 3 will be revised to more clearly indicate that sprinklers shall be removed and new sprinklers shall be provided. Sprinklers shall not be reinstalled. Melissa D. Meade, PE, Fire Protection Engineer, Woolpert

21. FP103 22. 21 13 13 23. 21 13 13 24. 28 31 00 Note 4 is not used on this sheet; delete. Provide water supply information. Delete components not used: valves, switches, gauges, etc. Delete the sprinkler flow and tamper switches, as these are not part of the project design. Also delete the door hold-opens if the 1-hour wall around the chapel is deleted. Concur Note 4 has been deleted. Melissa D. Meade, Fire Protection Engineer, Woolpert Concur Specification has been updated to reference the fire pump flow test on sheet FP001 and the associated note. Melissa D. Meade, Fire Non-Concur All of the components are not known at this time since the exact work will be shown on the shop drawings. Therefore, these components will remain in the specification in case the contractor chooses to use them. Melissa D. Meade, Fire Concur All of the components are not known at this time since the exact work will be shown on the shop drawings. Therefore, these components will remain in the specification in case the contractor chooses to use them. Door hold opens have been deleted from the specification since they are known not to be used. Melissa D. Meade, Fire Page 5 of 5