QAQC LABS ANALYTICAL DRYING

Similar documents
SHERWOOD SCIENTIFIC FLUID BED DRYER

WITH A LARGE RANGE OF TUB ASSEMBLIES, CONSTRUCTION MATERIALS AND SOFTWARE THE MODEL 501 OFFERS A FLEXIBLE PLATFORM ABLE TO ASSIST WITH;

USER GUIDE FLUID BED DRYER

THE LABORATORY FLUID BED DRYER

Tovatech LLC Phone (973) Rutgers St, Maplewood, NJ 07040

THE LABORATORY FLUID BED DRYER INSTRUCTION MANUAL

Mini Spray Dryer B-290 Technical data sheet

SD-06AG Laboratory Scale Spray Dryer

Safety vacuum drying oven for flammable solvents

FLUID BED EQUIPMENT. Drying

ROTO MIX HIGH SHEAR MIXER GRANULATOR

RADIO FREQUENCY (RF) DRYER APPLICATIONS

Powder Technology Division. Niro. Fluidized Spray Dryer FSD

Determination of the enthalpy of vaporization of liquids

Mini Spray Dryer B-290 Technical data sheet

Customers. The core of our innovation. Feeding&Conveying. Drying Dosing Temperature Control Refrigeration Granulation

From Drops to Powder From a Suspension to a Granulate. Innovative Processing of Fluids in Fluidised Bed Dryers

Fluid Bed Processor LFP LÖDIGE ALWAYS THE RIGHT MIX

BINDER Scientific Product Catalog

Roller Compactors. for the Pharmaceutical Industry

Incubators. with BioCote antimicrobial protection

Ribbon Blenders. Vertical Blenders. Tumble Blenders

t. +44 (0) f. +44 (0) e. w.

Vacuum drying oven for non-flammable solvents

Laboratory Freeze Dryers Routine Applications

Ingenieurbüro M.ZippererGmbH

Heating and Drying Ovens HeatEvent

GFD POWDER SYSTEMS LIMITED

Load type and process/autoclave selection

Air & Water Heat Pump R832

HPLC Column Ovens and Temperature Controllers

The SPX World of Industrial Drying Technologies

CROP PROTECTING AGENTS. Drying, mixing, milling, agglomeration/extrusion, deaeration & containment. Process technologies for tomorrow.

BlendingLine. MINICOLOR V MINICOLOR G GRAVICOLOR Dosing and mixing units. smart solutions

Where we are Aurum Process Technology has its headquarters in Murcia (Spain).

KOCH Curtain Coaters

TC-PLUS Thermal Cyclers

SIZE REDUCTION TECHNOLOGY

Vacuum Conveying. Industrial Equipment & Design Company....a world of experience in powder handling

SIHI dry Dry running vacuum pumps

RapidTrace + Automated SPE Workstation. Instruments. Accessories Racks Vial Adapters Test Tubes O-Rings Miscellaneous

Dehumidifying Dryers DP DP 615 Series

VACUUM HEATING AND DRYING OVENS Gentle and safe

Anhydro Drying Systems FOR THE PHARMACEUTICAL INDUSTRY

CEM Mars 5 Microwave Accelerated Reaction System

Integrated Process Solutions. Series 48 Heaters. heater jackets sizes 1 1/2'' to 4'' (nw 40 to nw 100)

VD 53 - Vacuum drying oven for non-flammable solvents

The AST Dryer

The Intelligent Choice for Rapid, Accurate Microwave Moisture/Solids Analysis. Innovators in Microwave Technology. Chemicals & Coatings.

Using the Model 1500 Portable Chilled Mirror Hygrometer

EQUIPMENT FOR OIL/PAPER DRYING AND STABILIZATION

FLUID BED DRYERS, COOLERS AND MOISTURIZERS

Chemical engineering range - 11/01 MULTI-FUNCTION DISTILLATION DVI/6000. Version presented DVI/6000 PIGNAT S.A.S. Subject to technical modifications

Agricultural. drugs of abuse. Food & Beverage. Pesticides SOLID PHASE EXTRACTION. Inject. Wash Elute. Cartridges. Concentrate. Silica.

M-Sens 2. Online-Moisture Meter for Solids. Operating Instructions. SWR engineering Messtechnik GmbH

VAC-U-DRY VACUUM DEHYDRATOR

COMPLETELY AUTOMATED HYDROLYSIS

Industrial Oven. Electrical Oven :- Figure 1. Tunnel Type Batch Oven for operating/using 2 nos.

2How does a vibratory fluid-bed dryer work?

Fibretherm. C. Gerhardt - Analytical Systems. Fibrebag-Systems

Heating and Drying Cabinets HeatEvent

Mixer and Blender Options for. Vacuum Drying Requirements

DRY BULK HANDLING SYSTEM

Training Papers Distillation with a Rotary Evaporator

StaticArc Screens. Water and Effluent Treatment

Incubators THE BENCHTOP EQUIPMENT HYGIENE SOLUTION

ARAO - ARAV HIGH FLOWRATE ATMOSPHERIC DRYER

ASSEMBLY & OPERATING INSTRUCTIONS

SPECIALIZED EQUIPMENT

Zoom Microplate Washer and Washer-Dispenser. Reliable Solutions for Your Daily Work

desiccant dryers hot air dryers mould drying

BlueSpin Magnetic Hotplate Stirrer

Freeze drying and alternative technologies for drying of biopharmaceutical products

CLEACOM Engineered System Solutions. Established 24/7 technology for the separation of dust and fume during compounding processes

Leading Safety Standards Superior Ease of Use Reduced Cost of Ownership. Intelligent. Evaporation

UC152 and US152. Key Features. Hotplate with Stirrer, UC152 US152. Technical Specification. Ordering Information

FREEZE DRYER LYOPHILIZER PRODUCTS LABFREEZ INSTRUMENTS CO., LTD

Evaporators, Sealers and other Equipment

AZTECA A LITRE STERILISER

Drying Systems. for mixing, granulating and drying in a single machine. The Pioneer in Material Processing. Reaction and.

Development Centre for Evaporation and Thermal Separation Technologies

Continuous Carousel Filter Dryer

MCR. Temperature Devices. ::: Intelligence in Rheometry

N-Wissen GmbH. Top Loading Autoclaves (95, 120, 135 L) Available top loading models: The Top Loading Autoclave range features:

MDS-15 High Throughput Closed Microwave Digestion/Extraction Workstation

Advances in Grinding, Classifying, and Shaping Technology for Color Toners Wolfgang Menzel, Hosokawa Alpine Aktiengesellschaft, Augsburg, Germany

SMA Microbial Air Sampler System Product Guide

Vacuum in the laboratory. products and solutions

Using the DewTrak II Dew Point/ Humidity Transmitter

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000

Vertical Centrifugal Coater VCC

Downstream Processing Prof. Mukesh Doble Department of Biotechnology Indian Institute of Technology, Madras. Lecture - 36 Drying

PERFORM Operating Document

LTE Scientific Ltd. Touchclave-R. The dynamic new range of cylindrical-section autoclaves from LTE Scientific

Vacuum drying VD VDL series

DDM SERIES. Desiccant Dryer Mobile Drying of free-flowing granular plastic materials

Specialized in the design and the tailor-made production of dryers, coolers and thermal processing equipment for industrial use.

MINTRAC MEAT INDUSTRY ENVIRONMENT CONFERENCE WASTE HEAT RECOVERY FROM RENDERING PLANTS PRESENTED BY DEREK HENDERSON

CRYSTALLISATION UNIT UOP14-MKII

Best Freeze Drying Solutions

Transcription:

WHAT IS FLUID BED? By forcing enough air through a bed of particles, the particle bed may assume a fluid-like state (resembling a boiling liquid). Heating the incoming air and managing air flow rate through the sample, the Model 501 Fluid Bed Dryer provides thorough mixing and maximum contact of solid with moving air. The result; a process producing more even and much quicker drying than conventional methods. FAST Delivering up to 2.5m3 per minute of air, the Model 501 Fluid Bed Dryer can break up wet samples and ensure vigorous mixing and rapid moisture removal. 5kg of wet "ideal" sample (80% moisture) can be dried in 15-20 minutes (5 Litre tub). High air flow rate gives: Air separated particles prevents lumps and caking, both of which make other drying processes much slower. HOMOGENEITY OF SAMPLE MILD NONAGGLOMERATING high moisture removal rates at relatively low temperatures thorough mixing, so no wet spots requiring extra thermal energy to penetrate an air cushion between particles to reduce abrasion and particle size alteration Static drying methods leave evaporation residues at the sample surface giving a heterogeneous sample. Fluid Bed Drying achieves the opposite. Mixing during Fluid Bed Drying gives homogeneous samples, making an ideal method of representative sample preparation for subsequent material analyses. WHITE STONE VA 22578 TEL (804)) 318-3686

REPRODUCIBLE Microprocessor control of air flow, inlet air temperature and drying period coupled with fluid bed action gives highly reproducible experiments and finished samples. After preliminary experiments, a known moisture content in the final sample (ideal for tablet forming) or removal of external (surface) moisture only, may be achieved. Drying times to required moisture content may be optimised and drying patterns studied to aid scale-up and plant design. Without a PC connected the Model 501 Fluid Bed Dryer can run one stored program of up to 16 steps (previously downloaded from a PC), or may be used as a conventional (manually controlled) Fluid Bed Dryer. Additional features of this advanced in-lab dryer technology include: Precise air flow feed-back control Membrane sealed controls to prevent ingress of particles into the instrument Reduced operating noise Advantages of the Model 501 Fluid Bed Dryer The Model 501 Fluid Bed Dryer offers significant advantages over conventional drying techniques: The high rates of heat and mass transfer ensure much faster and more homogeneous drying than other methods such as oven and vacuum drying Drying times range from a few seconds to minutes. Complete drying is usually achieved in under 15 minutes, the exact time for a given sample, airflow rate and temperature setting being very repeatable. A uniform, reproducible, moisture content can also be achieved with the appropriate settings Materials with moisture contents from a few per cent to over 80 per cent may be dried The inlet air temperature range from ambient to 200 C covers the majority of drying and solvent removal operations. Due to good mixing, the sample temperature is uniform and under close control during drying. This proves advantageous when drying heat sensitive materials or coating particles Among the wide range of materials that can be processed are pharmaceuticals, chemicals, minerals, foods, coals, wood chips, plastics, resins, etc. The high performance characteristics of this instrument allow it to be used for many applications in addition to drying, such as: WHITE STONE VA 22578 TEL (804)) 318-3686

Quick determination of moisture content (e.g. coal, tobacco, food products) by correlation with weight loss over 5 mins, using specified drying conditions Mixing and blending of solids Granulation and agglomeration Rough classification of particle size (i.e. Stokes Law) Why choose the Sherwood Scientific Model 501 Fluid Bed Dryer? Three Dryers in one Standalone Fluid Bed Dryer The base unit and specified tub assembly for standalone operation. Microprocessor control of air flow, inlet air temperature and drying period coupled with fluid bed action gives highly reproducible experiments and finished material samples. The Model 501 Fluid Bed Dryer is the latest model from Sherwood Scientific Ltd and features membrane sealed controls to prevent particle ingress and reduced operating noise. Programmable Fluid Bed Dryer The base unit and specified tub assembly connected to a PC hosting Sherwood Scientific Ltd's Fluid Bed Dryer Software program. The software allows control of all variable functions, data monitoring, feedback and creation of multistep drying protocols designed to dry samples in the most efficient manner. The Model 501 Fluid Bed Dryer can be programmed (via the computer interface) to step through up to 16 drying steps with the following parameters defined and controlled: Timer, Blower motor speed, and inlet air temperature. An optional pulse flow module can also be controlled using the software package. These variable parameters may be monitored and recorded throughout the drying programme. Each programme step may be terminated manually or when a preset time or condition (outlet temperature or relative humidity) has been achieved; whichever conditions occurs first. Analytical Fluid Bed Dryer The base unit and specified analytical tub assembly (fitted with auxiliary combined temperature and relative humidity probe) connected to a PC hosting Sherwood Scientific s Fluid Bed Dryer Software program. WHITE STONE VA 22578 TEL (804)) 318-3686

The ability to monitor in tub (above sample) "outlet" temperature and relative humidity allows for capture of additional data which may be used to understand better the drying behaviour of a particular material. The ability to transfer that data for post-run processing expands the scope for material drying behaviour studies, for example, material drying curve generation is possible. How to specify your dryer and accessories The user has to specify the tub together with the Inlet and Outlet Filters required for their application as follows: Material of construction: Glass or Stainless Steel Tub Volume: 5 Litre, 2 Litre or Mini-Tub (for use with Multi-Tub Base Adapter) Tub Type: Ordinary (Bags), Sealed, Analytical (GL32 side port) Dynamic Moisture Analysis, Classifier, Mini, Custom Inlet Filter: Material type, pore size Outlet Filter: Bag, Top Cap, Material type, pore size Bag Material Selection: (Nylon or Terylene are normally chosen) Nylon is resistant to alkali vapours Terylene shows greater resistance with acids Polypropylene is resistant to most chemicals but degrades more rapidly (than the other two) over 100 C Nomex is an alkali tolerant material suited to sustained high-temperature drying, e.g. ~200 C Accessories also to be specified include: With a Pulse Flow Module (50186001) you are able to pulse air into the sample and adjust the frequency of pulsing as well as the duration of alternating between pulsed and normal continuous flow. Pulsing the flow has been found analogous to providing external shaking and mixing. Samples which are difficult to fluidize, like long wet strands of irregular shaped leaves of tobacco or tea are 'blown apart' and mixed by pulsing the flow. The addition of a Humidity/Temperature Probe (50186500) to the Programmable Fluid Bed Dryer upgrades the instrument to an Analytical Dryer. RS232 Cable (92609052) for downloading program steps to the Fluid Bed Dryer and for collection of data for real-time feedback of temperature and relative humidity. Software (50186700) for control of variable functions, data monitoring and feedback and creation of multistep drying programs designed to dry samples in the most efficient manner and taking into account the changes in the materials behaviour as its moisture content changes. The table below lists the available options for Tubs, Inlet and Outlet Filters for the M501 Programmable Fluid Bed Dryer. WHITE STONE VA 22578 TEL (804)) 318-3686

A TUB UNITS SIZES MATERIAL 2 Litre Tub and Base Unit Glass 50035006 Stainless Steel 50035005 5 Litre Tub and Base Unit Glass 50035009 Stainless Steel 50035008 B C INLET FILTERS OUTLET FILTERS SS 60 Mesh Support Filter (50035113) with 45 Micron Nylon Inlet Filter (50035110) as standard; Tub Assembly 5 Litre with GL32 port supplied with screw fitted blank plate To fit Humidity Probe 50186500 F I L T E T R U B B A A G S S O E P M T B I L O I N E S Multi Tub Unit S 50035011 S E A L E D Nomex 50035407 Nylon 50035400 Glass 50035010 Also Available Polypropylene 50035404 (Must use Model SS 250 Mesh 50035114 Terylene 50035402 501 Fluid Bed Dryer to use SS 500 Mesh 50035115 Humidity Probe) Stainless Steel Tubs 4 x 50035012 SS 60 Mesh Support Filter as standard Glass Tubs 4 x 50035013 SS 60 Mesh Support Filter (50035309) with 45 Micron Nylon Inlet Filter (50035305) as standard; Also available SS 250 Mesh 50035307 SS 500 Mesh 50035308 3 Micron Polyester 50035306 5 Litre Sealed Glass Tub and Base with Clamp (50035014) Tub Assembly 5 Large Filter Bags SS 60 Mesh Support Filter (50035113) with 45 Micron Nylon Inlet Filter (50035110) as Glass 50135020 standard; (Must use Model Also available Small Filter Bags Nomex 50035408 Nylon 50035401 Polypropylene 50035405 Terylene 50035403 Top Cap with 45 Nylon Filter 50035020 Top Cap with SS 250 Mesh Filter 50035021 WHITE STONE VA 22578 TEL (804)) 318-3686

T U B O P T I O N S * Litre Glass Moisture Analysis (Includes ports for sample and Humidity Probe. Both ports supplied with screw fitted blank plates) 501 Fluid Bed Dryer to use Humidity Probe 50186500) SS 250 Mesh 50035114 SS 500 Mesh 50035115 3 Micron Polyester Filter for smallest particle size 50035120 Top Cap with SS 500 Mesh Filter 50035022 Top Cap with Nylon Filter Bag 50035023 Top Cap + 3 Micron Polyester Filter 50035024 Low Density Glass Tub Classifier 50035049 Assembly 50035020 fitted as standard to Low Density Classifier Mini Tub, Sealed Tub, Inlet and Outlet Sets Multi Tub Unit 50035011 Glass Tub 4 x 50035033 Mini 45 Micron Nylon Filter Set 50035310 Mini 3 Micron Polyester Filter Set 50035311 Mini SS 250 Mesh Filter Set 50035312 Mini SS 500 Mesh Filter Set 50035313 (SS 60 Mesh Support Filter (50035309) and 45 Micron Nylon Inlet Filter (50035305) as standard) * (Includes Silicon "O" Ring and Ground Glass Flange with Clamp) Specifying Process The Sherwood Scientific Model 501 Fluid Bed Dryer is a Lab Scale (Bench Top) dryer with a maximum sample capacity of 5Kg. There is a wide variety of drying tubs (volume and material of construction), inlet & outlet filters, and other accessories available; both to handle as a wide range of sample types as possible and enhance the capability of the drying system. Therefore each system requires specifying in some detail to reflect individual customer requirements and sample characteristics in order to prepare an appropriate quotation. Outlined below are prompts about the sample type and required process and hence implications for component selection: SAMPLE TYPE SYSTEM WHITE STONE VA 22578 TEL (804)) 318-3686

REQUIREMENTS Sample quantity (weight and/or volume) A wet sample should occupy about 1/3 of the tub assembly volume. As a sample dries and its density drops, its apparent volume will increase to about ½ the tub volume. Tubs should be purchased that are 3 x the volume of the sample size. The mini tubs are 250ml in capacity and can be used effectively on samples weighing from 5 to 50 grams per tub. Four tubs can be dried simultaneously. Moisture content at start of drying process The Model 501 Fluid Bed Dryer is designed for damp materials not slurries with free water. Flammable Solvents present The Model 501 Fluid Bed Dryer is not spark or explosion proof. It is not suitable for the removal of flammable solvents with low flash points. You need to know the minimum particle size in the sample in order to choose a suitable Particle size-minimum to maximum (not just mesh/pore size for inlet and outlet filters to average) prevent sample falling out the bottom of the tub or being blown out the top. Tub made from glass or metal Glass is ideal for developing drying processes; you can observe the material's behaviour as it dries. The optimum flow rate is easy to select judging by the fluidised samples appearance. The operator may estimate the state of dryness, shape and particle size distribution by the appearance of the sample flowing in the tub. Stainless Steel could be useful in the food industry where regulations may not permit use of glass items within food production or preparation areas. Sealed tub or filter bag Samples with a wide or bi-modal particle distribution are difficult to fluidise without sample overflow into the bag. A sealed top cap is advisable for such samples and any sample with a particle size less than 40 microns. 3 micron polyester filters can be used for mini tubs, 2 and 5 litre tubs. These filters are effective for 5 to 25 micron particles but greatly reduce air flow rate through the WHITE STONE VA 22578 TEL (804)) 318-3686

sample. Drying times normally occurring between 10 to 30 minutes can take up to several hours. Many of the main advantages of fluid bed drying may be lost. PROCESS Simple dryer Standalone Base Unit Multistep drying process Add software and RS232 cable In-time drying progress feedback Add Moisture/Humidity Probe which means you have to select a tub with a GL32 side port. Only the 5 litre glass tub assemblies, 500 35 010 and 501 35 020 can have an inlet for the outlet humidity and temperature probe. Only these tubs can fully utilise all the features on the M501. Data collection Add software and RS232 cable Data manipulation with drying curve generation Add software and RS232 cable Add sample to dryer without removing outlet Specify Dynamic Moisture Analysis tub (501 filter 35 020) Model 501 Fluid Bed Dryer Configurations Examples With a large range of tub assemblies, construction materials and software the Model 501 Fluid Bed Dryer offers a flexible platform able to assist with: Studies of material drying behaviour The optimisation and scale-up of drying processes Preparation of small sample batches for subsequent materials studies WHITE STONE VA 22578 TEL (804)) 318-3686

Model 501 Fluid Bed Dryer* shown with 5 Litre Glass Tub 50035008 and Large Filter Bag. Remember to specify Tub Inlet Filter (mesh size and material type) and bag material required. *Fluid Bed Dryer Base Unit Models 110v # 501 00 200 230v # 501 00 201 Model 501 Fluid Bed Dryer shown with 5 Litre Glass Tub with GL32 side port 50035010, Temperature/Humidity Probes and Large Filter Bag. Please specify Tub Inlet Filter (mesh size and material type) and bag material required and remember to order the Temperature/Humidity Probe 50186500. Model 501 Fluid Bed Dryer shown with 5 Litre glass Dynamic Moisture Analysis Tub 50135020 with Sealed TopCap Assembly and GL32 side port, Temperature/Humidity Probe plus side port for samples. Please specify Tub Inlet Filter (mesh size and material type) and Top Cap Filter (required mesh size and material type) and remember to order the Temperature/Humidity Probe 50186500. WHITE STONE VA 22578 TEL (804)) 318-3686

Model 501 Fluid Bed Dryer shown with Multi-Tub unit 50035011 and Glass Mini-Tubs with fixed Top-Caps and bags for drying of small batches of sample. Mixture of TopCaps and Bags shown are for illustration purposes only. Stainless Steel Mini-Tubs for use with Small Filter Bags are also available. Model 501 Fluid Bed Dryer shown with Low Density Classifier 50035048 which allows for fractionation of samples with wide particle size/density distribution and collection of fractions within that range. It also allows separation of desirable sample elements from bulk samples, for example, removal of tree seed "wings" from the seeds. Typical Uses Rapid drying of many types of chemicals, foodstuffs and minerals with up to 80% moisture content Drying of heat sensitive materials at low temperatures under accurately controlled and uniform conditions Determining the moisture content of substances such as adhesives, tobacco, dried foods and building materials Converting cake or precipitate from chemical or pharmaceutical production into powder or granular form Removing solvents such as Methanol or Heptane from plastics and polymers by accelerated vaporization WHITE STONE VA 22578 TEL (804)) 318-3686

Determining thermodynamic parameters for industrial dryer design e.g. heat/mass balance, thermal efficiency and calculating heat transfer coefficients Obtaining uniform coatings of evaporation residues on particles Simulating large scale process installations to monitor quality, efficiency and carry out small batch treatment The Basic Design The basic Model 501 Fluid Bed Dryer incorporates an air pump, heating coil, and temperature measurement (with control and timer). Air is drawn through an inlet filter, passed over a heating element and forced through a Support Filter (which holds the weight of the sample) and a Tub Inlet Filter (selected for pores smaller than the sample particle size). The air passes through the sample contained within a tub (glass or stainless), and finally through an Outlet Filter which can be a Filter Bag. Bag material is selected to be chemically inert to emitted sample vapours. Alternatively, "Sealed" tub assemblies are available, where a Top Cap (which has an Outlet Filter and Support Filter) seals onto a flanged tub with a silicon O-ring and clamp (for particles less than 40 microns in size). Sealed Tubs are only available in Glass. The Model 501 Programmable Fluid Bed Dryer: THE BASICS The microprocessor controlled Model 501 Fluid Bed Dryer can be used as a standalone unit or programmed via a computer interface to step through as many as sixteen drying stages with each stage having the following parameters defined controlled and monitored: Inlet air temperature Blower motor speed Pulse flow function (for difficult to fluidise samples) Without a computer interface the Programmable Fluid Bed Dryer can run one stored program of up to sixteen steps, or can be used as a conventional, manually adjusted, dryer. Additional features of this advanced in-lab dryer include: precise air flow control and membrane sealed controls to prevent ingress of particles into the instrument. The following items are required to achieve programmable drying: WHITE STONE VA 22578 TEL (804)) 318-3686

The Fluid Bed Dryer Software Tub Assembly RS232 Computer Interface Cable Computer The addition of a Humidity/Temperature Probe to the Programmable Fluid Bed Dryer upgrades the instrument to an Analytical Dryer. The following data is captured and stored: Air flow rate Inlet temperature Pulse flow condition Outlet temperature Relative humidity Each drying step can be programmed to terminate either on duration of step, humidity level achieved or outlet temperature reached. The Analytical Fluid Bed Dryer can be used to monitor both manual as well as programmed operations. The captured data can be transferred to an Excel Worksheet, which allows drying curves and moisture calculations to be performed. WHITE STONE VA 22578 TEL (804)) 318-3686

Inlet air temperature, blower motor speed, in-tub temperature and relative humidity can all be recorded against time (using software and the temperature humidity probe). WHITE STONE VA 22578 TEL (804)) 318-3686