Location(s) where activities are performed under accreditation Head Office Koolwaterststraat 1 6161 RA Geleen The Netherlands Location Abbreviation/ location code Koolwaterststraat 1 6161 RA Geleen The Netherlands Sampling a Drinking water, process water and spring water. Sampling for microbiological analysis (the corresponding tests are outsourced) 3528 in accordance with NEN 6265 and NEN-EN-ISO 19458 b Surface water Sampling for microbiological analysis (for all accredited activities listed in the scope) 3540 in accordance with NEN-EN-ISO 19458 1 If there is a referral to a code starting with NAW, NAP, EA or IAF, this concerns a scheme mentioned on the RvA-BR010 list (https://www.rva.nl/en/document/download/br010-lijst). If no date or version number is mentioned for a normative document, the accreditation concerns the most current version the document or scheme. This annex has been approved by the Board the Dutch Accreditation Council, on its behalf, J.A.W.M. de Haas Director Operations Dutch Accreditation Council RvA Page 1 11
Field measurements 1 Surface water Determining the ph value; potentiometric method 2 Surface water Determination a electrical conductivity; conductometric method 3 Surface water Determination dissolved oxygen in water; electrochemical method 3540 in accordance with NEN-EN-ISO 10523 3540 3540 in accordance with NEN-EN-ISO 5814 Inorganic parameters (chemical) 4 Waste water Determination the dry matter fraction; gravimetric method 3640 in accordance with NEN 6499 (in accordance with NEN-EN 15934 and NEN 6499 chapter 6) 5 Sludge Determination the dry matter fraction; gravimetric method 3640 in accordance with NEN 6499 (in accordance with NEN-EN 12880 + NEN 6499 chapter 3.1 or in accordance with NEN-EN 15934) 6 Sludge Determination residue on ignition; loss-on-ignition method, gravimetric method 3640 in accordance with NEN 6499 and (in accordance with NEN-EN 12879 + NEN 6499 chapter 3.1 or in accordance with NEN-EN 15169 + NEN 6499 chapter 3.1) 7 Waste water and surface water Determination suspended solids; filtration through glass fiber filters, gravimetric method 3641 in accordance with NEN 6499 (in accordance with NEN-EN 872 and in accordance with NEN 6499 chapter 8) 8 Waste water Determination fluoride; potentiometric titration 3599 in accordance with NEN 6483 (1982) 9 Waste water, surface water and sludge Determination the chemical oxygen demand; potentiometric titration 3651 in accordance with NEN 6633 Dutch Accreditation Council RvA Page 2 11
10 Waste water and surface water Determination biochemical oxygen demand, dilution and seeding under the addition allylthiourea; electrochemical method 3591 in accordance with NEN-EN 1899-1 11 Waste water and surface water Determination biochemical oxygen demand, method for undiluted samples; electrochemical method 3592 in accordance with NEN-EN 1899-2 12 Waste water, ground water and surface water Determination ammonia nitrogen and organic bound nitrogen content, after mineralization with selenium; Kjeldahl titrimetric method 3584 equivalent to NEN-ISO 5663 13 Sludge Determination ammonia nitrogen and organic bound nitrogen content, after mineralization with selenium; Kjeldahl titrimetric method 3585 equivalentto NEN 6641 (1983) 14 Waste water, ground water and surface water Determination ammonium, nitrate, nitrite, chloride, orthophosphate and sulfate content; discrete analysis system and spectrophotometric analyses 3506 in accordance with NEN-ISO 15923-1 15 Waste water, ground water and surface water Determination dissolved nitrite and nitrate; discrete analysis system and spectrophotometric analyses 3506 (measurement in accordance with NEN-ISO 15923-1) 16 Waste water, ground water and surface water Determination total phosphor; discrete analysis and spectrometric analyses 3506 (measurement in accordance with NEN-ISO 15923-1) 17 Polyamide 46 (Nylon 46) Determination the water content; coulometric (Karl Fischer method) 4389 in accordance with NEN-EN-ISO 15512, method B2 Dutch Accreditation Council RvA Page 3 11
Inorganic parameters (metal analysis) 18 Waste water Determination arsenic after digestion with aqua regia; AAS hydride 19 Surface water Determination mercury after acidification (ph <2 dissolved); Flowinjection AAS 20 Waste water Determination mercury after digestion with aqua regia; Flowinjection AAS 21 Sludge Determination mercury after digestion with aqua regia; Flowinjection AAS 22 Surface water Determination elements after acidification (ph <2 dissolved); ICP-MS Be, Na, Mg, Al, K, Ca, Fe, V, Cr, Mn, Co, Ni, Cu, Zn, As, Se, Cd, Ba, Tl, Pb and U 23 Waste water Determination selected elements after digestion with aqua regia; ICP-MS Be, Al, P, Ti, V, Cr, Mn, Co, Ni, Cu, Zn, Se, Sr, Mo, Ag, Cd, Sn, Sb, Ba, Ce, Tl, Pb and U 3548, 3597 equivalent to NEN 6953 (digestion equivalent to NEN-EN-ISO 15587-1, measurement in accordance with NEN 6432) 3524 3548, 3568 (digestion equivalent to NEN-EN-ISO 15587-1, measurement ) 3548, 3568 equivalent to NEN 6950 (digestion equivalent to NEN 6961, measurement in accordance with NEN- ISO 16772) 4265 in accordance with NEN 6953 (measurement in accordance with NEN-EN-ISO 17294-2) 3548, 4266 equivalent to NEN 6953 (digestion equivalent to NEN-EN-ISO 15587-1, measurement in accordance with NEN-EN-ISO 17294-2) Microbiologists parameters 24 Surface water Detection and enumeration Escherichia coli (E.coli) by inoculation in a liquid medium; Most Probable Number method 3552 in accordance with NEN-EN-ISO 9308-3 Dutch Accreditation Council RvA Page 4 11
25 Surface water Detection and enumeration major intestinal Enterococci by inoculation in a liquid medium; Most Probable Number method 3553 in accordance with NEN-EN-ISO 7899-1 Physical tests 26 Polypropylenegranulate Determination the melt mass flow rate (MFR); viscometric method 4248 in accordance with NEN-EN-ISO 1133 27 Polypropylene and polypropylene s Determination the tangent E- Modulus and flexural strength; three-point loading test 2356 in accordance with ASTM D790 (2002) 28 Polypropylene test bars Determination IZOD impact strength, impact test 2836 in accordance with ISO 180 (1993) 29 Polyamide after condensate Determination the viscosity number; capillary viscometric method 3117 30 Plastics Determination the Charpy impact strength (maximum energy up to 4 J); impact test 31 Plastics Determination the tensile properties; tensile test 4208 in accordance with NEN-EN-ISO 179-1 (1eA at 23 ºC) 4209 in accordance with NEN-EN-ISO 527-2 (1A bars at 23 ºC) 32 Plastics and ebonite composites Determination the Heat Deflection Temperature (HDT) under pressure; bending test 3618 in accordance with NEN-EN-ISO 75-1 and NEN-EN-ISO 75-2 33 Thermoplastics Determination the vicat stening temperature (VST) thermoplastic materials; penetration test 3550 in accordance with NEN-EN-ISO 306 34 High-performance Thermoplastic Copolyester film (internal produced granulate) Determination the number gels and defects (detection and classification); optical sensors number gels/ defects >0.1 mm, >0.2 mm, >0.3 mm, >0.4 mm, >0.5 mm, >0.6 mm, >0.7 4007 in accordance with ASTM D7310 mm, >0.8 mm, >0.9 mm per m 2 Dutch Accreditation Council RvA Page 5 11
Emission measurements on location; sampling (NPR-CEN/TS 15675, Quality assurance according to the NEN-EN 14181) c Air emissions, smoke Sampling: requirements for measurement sections, measurement sites, planning and reporting. 3805 en 3806 in accordance with NEN-EN 15259 d Air emissions, smoke Sampling with the purpose the determination the content gaseous ammonia (for activity no. 47 this scope) 4064 in accordance with NEN 2826 e Air emissions, smoke Sampling for the determination the sulphuric oxide SO2 in flue gases (for activity no. 48 this scope) 4072 in accordance with NEN EN 14791 f Air emissions, smoke Sampling for the determination the concentration total mercury (the corresponding determination is structurally outsourced to an accredited laboratory) 4083 in accordance with NEN-EN 13211 g Air emissions, smoke Sampling for the determination the mass concentration and emission As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Ti and V (the corresponding determination is structurally outsourced to an accredited laboratory) 4084 in accordance with NEN-EN 14385 Emission measurements on location; Tests (NPR-CEN/TS 15675, Quality assurance according to the NEN-EN 14181) 35 Air emissions, smoke Determination the velocity and volume flowrate ( gas streams in ducts); Pitot tube method 3287, 3288, 4285 in accordance with ISO 10780 and NEN-EN-ISO 16911-1 Dutch Accreditation Council RvA Page 6 11
36 Air emissions, smoke Determination the nitrogen oxides(no, NO2, NOx); continuous measurements, chemiluminescence 3291 in accordance with NEN-EN 14792 and NEN-ISO 10849 37 Air emissions, smoke Determination carbon monoxide CO, carbon dioxide CO2 and oxygen O2; infrared absorption method (CO2 en CO) and Para magnetism method(o2) 3464 in accordance with NEN-EN 15058, NEN-EN 14789 and NEN-ISO 12039 38 Air emissions, smoke Determination dust emissions; gravimetric method, isokinetic sampling 3465 en 3466 in accordance with NEN-EN 13284-1 and NEN-ISO 9096 39 Air emissions, smoke Determination dinitrogen monoxide (N2O); non-dispersive infrared method 3317 in accordance with NEN-EN-ISO 21258 40 Air emissions, smoke Determination the concentration gaseous chlorinated compounds (including sampling); spectrophotometric method 3499 in accordance with NEN-EN 1911 41 Air emissions, smoke Determination gaseous fluoride content, (including sampling); potentiometric method 3500 in accordance with NEN-ISO-15713 42 Air emissions, smoke Determination the weight index the combustion gases 3501 in accordance with NEN-EN-ISO 6976 Dutch Accreditation Council RvA Page 7 11
43 Air emissions, smoke Determination the water vapour concentration in ducts; gravimetric method 3502 in accordance with NEN-EN 14790 44 Air emissions, smoke Determination the temperature, pressure and humidity; thermocouple, pressure measurements and capacitive 3503 in accordance with ISO 8756 45 Air emissions, smoke Determination the mass concentration total organic carbon (expressed as TOC) (CxHy), FID 3504 in accordance with NEN-EN 12619 46 Air emissions, smoke Determination the content sulphurdioxde (SO2); UVspectrometry 3505 in accordance with NEN-ISO 7935 47 Air emissions, smoke Determination gaseous ammonia; discrete analyser 4064 en 3506 in accordance with NEN 2826 48 Air emissions, smoke Determination the sulphuric oxide SO2 in flue gases; ion chromatography 4072 en 1003 in accordance with NEN-EN 14791 Migration plastics 49 Materials and articles non-moisture sensitive plastics in contact with foodstuffs Determination the overall migration into olive oil, by total immersion; gravimetric method and GC-FID 3467 in accordance with NEN-EN 1186-2 Dutch Accreditation Council RvA Page 8 11
50 Materials and articles non-moisture sensitive plastics in contact with foodstuffs Determination the overall migration into olive oil by cell; gravimetric method and GC-FID 3469 in accordance with NEN-EN 1186-4 51 Materials and articles plastics in contact with foodstuffs Determination the overall migration into aqueous simulants, by total immersion; gravimetric method 3468 in accordance with NEN-EN 1186-3 52 Materials and articles plastics in contact with foodstuffs Determination the overall migration into aqueous based food simulants by cell; gravimetric method 3470 in accordance with NEN-EN 1186-5 53 Aqueous food simulants (acetic acid 3% ethanol 10/20/50/95% isooctane, water and MPPO) that have been in contact with materials and plastic articles Determination Bisphenol A; UPLC Fluorescence 4396 54 Aqueous food simulants (acetic acid 3% v / v in water and ethanol 10 to 15% v / v in water) that have been in contact with materials and plastic articles Determination hexamethylenetetramine (HMTA) and formaldehyde; spectrophotometric method 4230 in accordance with NPR-CEN/TS 13130-23 Dutch Accreditation Council RvA Page 9 11
Test methods for emission from materials 55 Non-metallic materials for the interior Determination the formaldehyde release; Spectrophotometric method 4207 in accordance with VDA 275 (formaldehyde) and NEN-EN 322 (moist) 56 Non-metallic materials for the interior Determination the thermal desorption organic emissions; Thermal Desorption GC-MS 4200 in accordance with VDA 278 57 Non-metallic materials for the interior Determination the Fogging characteristics; reflectometric method and/or gravimetric method 4009 in accordance with DIN 75201 in accordance with PV 3015 (1994-05) Volkswagen (gravimetric method) in accordance with NEN-ISO 6452:2007 (ISO 6452:2007) in accordance with SAE J1756 (2006-08) in accordance with D45 1727 (2012-11), PSA Peugeot - Citroen 58 Non-metallic materials for the interior Determination emission volatile organic compounds (VOC); headspace GC-FID 4384 in accordance with VDA 277 in accordance with PV 3341 59 Non-metallic materials for the interior Determination the odour characteristics; Sensory Testing with odour panel 4247 in accordance with VDA 270 en VD 3900 60 Emitted air from internal components and materials The determination the total volatile organic compounds (TVOC, expressed as toluene equivalent); GC-MS 4431 in accordance with NEN-ISO 16000-6 (including associated sampling from the small emission chamber via Tenax TA tubes) 61 Emitted air from internal components and materials Determination the content formaldehyde and acroleine; UPLC-UV (including associated sampling from the small emission chamber via DNPH cartridges) 4430 in accordance with NEN-ISO 16000-3 Dutch Accreditation Council RvA Page 10 11
62 Internal parts and materials for The determination the emission total volatile organic compounds (expressed as PPM propane); Small chamber method (1 m 3 ), FID 4432 in accordance with NEN-ISO 12219-4 Dutch Accreditation Council RvA Page 11 11