CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

Similar documents
CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau. Permit fees shall be assessed in accordance with the Permit Fee Schedule

Clark County Department of Building & Fire Prevention 4701 West Russell Road, Las Vegas, NV (702) FAX (702)

Rancho Cucamonga Fire Protection District Prevention Bureau Standard

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

FIRE & LIFE SAFTEY STANDARD

Bold items are particular to the City of Euless

Moreno Valley Fire Department Fire Prevention Bureau. New and Existing Fire Alarm & Signaling Systems Guideline

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

COMMERCIAL (IBC) FIRE ALARM SUBMITTAL GUIDE

SANTA CLARA COUNTY Winchester Blvd., Los Gatos, CA (408) (408) (fax)

1.3 REFERENCE STANDARDS

CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services 575 E. Flamingo Road, Ls Vegas, NV (702) FAX (702)

RULES OF DEPARTMENT OF COMMERCE AND INSURANCE DIVISION OF FIRE PREVENTION CHAPTER FIRE PROTECTION SPRINKLER SYSTEM CONTRACTORS

Public Notice of Amendment to New Shoreham General Ordinances Chapter 5 Fire Prevention and Protection New Article IV Fire Alarm Ordinance

September 30, Dear Fire Suppression System Contractor/Designer:

CITY OF LONG BEACH Department of Development Services BUILDING AND SAFETY BUREAU FIRE ALARM / ELECTRICAL FIRE PLAN REVIEW CHECKLIST

Medical Gas and Vacuum Systems

STANDARDS UPDATE NOTICE (SUN) ISSUED: February 5, 2018

Date Issued: December 14, 2017 Revision: 2.1

May 1, Dear Fire Suppression System Contractor/Designer:

Update all extract references to NFPA documents (including NFPA 72) in Chapter 3 and related annex material to the latest editions.

THIS ORDINANCE ONLY AFFECTS EXISTING FIRE ALARM SYSTEMS.

Brighton Area Fire Authority

Applying Performance-based Fire Alarm System Design Part 4

Full Service Central Station Fire Alarm Listing Evaluation

Valuation: # of Plans Submitted: # of pages: Type of Work (select one): New Addition Existing System/Modification Project Name: Scope of Work:

Article 3: Police Regulated Occupations and Businesses. Division 37: Burglary, Robbery and Emergency Alarm Systems

Standard Operating Procedure Ottawa Fire Services. Fire Operations- Structural Fire Incidents SUBJECT. Fire Alarm Systems (Silence/Reset) - Revised

Chapter 4: Fire Protection Systems

DEPARTMENT OF PUBLIC SAFETY DIVISION OF FIRE PREVENTION AND CONTROL

1. Floor above/floor below notification. 2. Private alarm notification. 3. Not Used 4. Voice alarm notification. 5. Not Used.

IOWA STATE FIRE MARSHAL DIVISION Attn: Licensing Administrator

WESTIN HOTEL. Smoke Control System. Testing Procedures Manual. October 10, Copyright Impact Engineering, Inc All Rights Reserved

Standard Operating Procedure Ottawa Fire Services. Fire Safety Plan Approval - Revised

Application for Certification for an Alarm System Contractor

AIRPORT OFFICE BUILDING. Smoke Control System. Testing Procedures Manual. September 10, 2016

PART 1 GENERAL Quality Assurance A. Fire Alarm Contractor Qualifications:

Chapter ALARM SYSTEMS

Permitting and Licensing for Hazardous Material Use and Storage

DATE: CHECK AMOUNT: CHECK NUMBER: RENEWAL APPLICATION. COMPANY CERTIFICATE OF REGISTRATION And INDIVIDUAL LICENSE RENEWAL

RULES OF DEPARTMENT OF COMMERCE AND INSURANCE DIVISION OF FIRE PREVENTION CHAPTER FIRE EXTINGUISHERS TABLE OF CONTENTS

Mount Laurel Fire Department, Office of The Fire Marshal FIRE WATCH NOTIFICATION

CAN/ULC-S561. To comply, or not to comply. actually it s not even a question! Underwriters Laboratories of Canada. By Alan Cavers & Brian McBain

Should you have further questions, please feel free to contact the Fire Prevention Branch.

PART 1 GENERAL Quality Assurance A. Fire Alarm Contractor Qualifications:

AUTOMATIC FIRE SPRINKLER SYSTEMS

a) Establishment of emergency procedures to be followed at the time of an emergency;

Fire Protection System Contractors and Systems. Submission of the Application for a Water-Based Fire Protection Inspector Permit

I. Scope: II. Environmental Health and Safety Fire Alarm System Impairment Program - Guideline Revision Date: April, 2018

Fire Protection System Contractors and Systems. Submission of the Application for a Water-Based Fire Protection Inspector

You are required to READ ALL PAGES. of this application

APPENDIX H (DESIGN SUBMISSION CRITERIA)

M E M O R A N D U M. Technical Committee on Supervising Station Fire Alarm and Signaling Systems

LEE COUNTY ORDINANCE NO

The definitions provided in , C.R.S., shall apply to these rules and regulations. The following additional definitions shall also apply:

BUILDING, FIRE, AND LIFE SAFETY CODE ENFORCEMENT AND CERTIFICATION OF INSPECTORS FOR HEALTH FACILITIES LICENSED BY THE STATE OF COLORADO

At least 10 calendar days prior to project start date Within the last 30 days of a project that will extend beyond 12 months

MECKLENBURG COUNTY FIRE MARSHAL S OFFICE

Table OUT OF SERVICE. Building Fire Video 1/15/ Inspection, testing and maintenance. Standards Further Referenced by FCNYS

CAN/ULC-S1001, INTEGRATED SYSTEMS TESTING OF FIRE PROTECTION & LIFE SAFETY SYSTEMS Simon Crosby, LEL, CET, CFPS October 21, 2015

Florida Building Code Chapter 9 Fire Protection Systems Advanced Course

Fire Alarm, Water Flow Alarm & Signaling Systems

ALTA LOMA RIDING CLUB EMERGENCY RESPONSE TEAM ANIMAL EVAC ORGANIZATIONAL CHART EVAC GROUP SUPERVISOR

City of Reedley Community Development Department 1733 Ninth Street Reedley, CA (559) FAX

FIRE SAFETY PLAN. Ceramics/Sculpture Building 47 Service Rd 1 S Winnipeg, MANITOBA. May / Prepared by: Chris Pancoe

Sec False alarms.

NFPA 72 Code Changes vs 2013

CAN/ULC-S1001, INTEGRATED SYSTEMS TEST OF FIRE PROTECTION AND LIFE SAFETY SYSTEMS

DIVISION C ADMINISTRATIVE PROVISIONS

Town of Cochrane Policy

Second Revision No. 104-NFPA [ Section No ] Submitter Information Verification. Committee Statement

Norfolk Fire Department Fire Prevention & Information

FORT MYERS BEACH FIRE DEPARTMENT JOB DESCRIPTION

Purpose Definitions. Chapter BURGLAR ALARM SYSTEMS *

CITY OF PORTSMOUTH Department of Public Works MUNICIPAL COMPLEX FIRE ALARM. Bid # Addendum #1

2. HVAC and smoke control systems; fire, smoke, and combination fire/smoke dampers. 5. Central control and monitoring system.

7.3 Design and Development Design and development planning Design and development inputs Design and development outputs 7.3.

Type of Fire Alarm Control Panel: System is: Existing OR New If new, provide Electrical Permit Number:

The definitions provided in , C.R.S., apply to these rules and regulations. The following additional definitions also apply:

Authorized individuals to be notified. Include two (2) persons with access to the premises to allow emergency access.

Purpose : Project Manager. Professional. Contractor: devices/system. compatibility

RE: PERMIT REQUIRED TO WORK ON FIRE ALARM SYSTEMS IN THE RMWB

Minimum Standards for Engineers Practicing Fire Protection Engineering in the State of Oklahoma September 14, 2016

Westerville, OH Code of Ordinances. CHAPTER 969 Alarm Systems

CODE ENFORCEMENT AND CERTIFICATION OF INSPECTORS FOR PUBLIC SCHOOLS, CHARTER SCHOOLS AND JUNIOR COLLEGES

DERRY FIRE DEPARTMENT LISTED AGENT CERTIFICATION PROGRAM

City of Regina Alarm Bylaw

VERIFICATION OF FIRE ALARM SYSTEMS

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

WESTERN CONNECTICUT STATE UNIVERSITY HAZARDOUS WASTE CONTINGENCY PLAN PROCEDURE E-115

GUARDED STATUS INFORMATION and REQUIREMENTS For OWNERS AND OPERATORS Of REFRIGERATION PLANTS

DEPARTMENT OF PUBLIC SAFETY. Division of Fire Prevention and Control 8 CCR FIRE SUPPRESSION RULES

City of Vista Fire Department

Standard of Practice - Fire Alarm Systems. NOTE: Significant revisions or additions to the previous standards are highlighted in italics.

Transcription:

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau 575 E. Flamingo Road, Las Vegas, NV 89119 (702) 455-7316 FAX (702) 455-7347 Permit Type: 105.6.54 Control Number: A.0 Effective Date: TITLE: PROPRIETARY (SELF) MONITORING FACILITIES SCOPE: Clark County Fire Department requirements for the submittal and design of a Proprietary (Self) Monitoring Facilities permit. PURPOSE: To standardize plan/permit requirements of the Fire Department in accordance with the Clark County Fire Code. Permits for Proprietary (Self) Monitoring Facilities expire one year from the date of issue and shall be renewed annually. DEFINITIONS: Assessor s Parcel Number (APN): A unique number assigned to each property by the Clark County Assessor s office. Operators: Operators are personnel that monitor fire alarm control unit signals at a facility, operate the fire alarm system, and take such action as required by the approved Standard Operating Procedures for that facility. ANNUAL RENEWABLE PERMIT PROCEDURE: After issuance of your initial permit(s), your permit(s) will be valid for one year. Approximately 30-60 days prior to the expiration of your permit, a renewal notice will be mailed to you with instructions for the annual permit renewal. If you do not receive this notice, it is your responsibility to submit the renewal application. Please refer to the website for additional information. PERMIT FEES: Permit fees shall be assessed in accordance with the Permit Fee Schedule as adopted in the Clark County Fire Code. For applications that are expedited, additional fees shall apply. SPECIFICATIONS AND SUBMITTAL REQUIREMENTS: An application must be completed for each submittal. A minimum of three sets of the complete submittal package shall be submitted with the permit application. The complete submittal package will consist of a report, and may also include plans, Page 1 of 5

specifications, etc. The report shall describe compliance in accordance with the Clark County Fire Code, as adopted and amended. All submittals must be legible and readable or the plan shall be issued a correction letter for cause. The submittal package shall address all of the following: 1. Indicate the project name, address, and APN (Assessor s Parcel Number). Note that each separate facility having a unique address requires a separate permit. 2. The proprietary supervising station facility shall maintain an annual operational permit. 3. The proprietary supervising station shall be located in a property s Fire Command Center, or other approved location. 4. The approved location shall have at a minimum the following items: a. A fire alarm annunciator that has appropriate control capabilities. b. An all-call microphone and all-call evacuation switch. c. Switches that activate the evacuation message, the investigation message (if applicable), and the all-clear message for the active alarm zones. d. A printer that is provided with a secondary power source such as an uninterruptible power supply or other approved means. e. Copy of the approved Standard Operating Procedures (SOP). 5. Two means of retransmission shall be provided. The primary means of retransmission shall be a land-line telephone. The secondary means of retransmission shall be a dedicated cellular telephone. 6. Proprietary supervising stations shall be operated by trained, competent personnel in constant attendance responsible to the owner of the protected property. 7. Annually the applicant shall certify in writing to the fire code official that all authorized personnel have received training in the recognition and proper handling of alarm signals. Evidence of annual training for each authorized personnel shall be provided when requested by the fire code official. 8. Operators shall be trained on an annual basis either by the installing fire alarm contractor, by the fire alarm maintenance contractor, or by the manufacturer s representative of the installed fire alarm system. Documentation of annual training shall be kept on site and available upon request of the fire code official. 9. Operators shall be trained on the following: a. How to differentiate between a water flow alarm signal, a fire alarm signal, a fire supervisory signal, and a fire trouble signal. b. The basic operations of the panel, including but not limited, to the following: signal acknowledgment, resetting of the fire alarm system, Page 2 of 5

selection of evacuation zones, and activating of the evacuation, investigation (if applicable), and all-clear evacuation messaging. c. The Standard Operating Procedures (SOP s) for the facility. 10. At least two operators shall be on duty at all times. One of the two operators shall be permitted to be a runner. 11. A Standard Operating Procedure (SOP) shall be submitted to the fire code official when applying for the required annual permit for proprietary supervising station facilities. The SOP shall outline procedures with regards to emergency procedures and the disposition of the alarm, supervisory, and trouble signals. The SOP shall include at a minimum the following items: a. The number of operators that will be on duty at all times. b. The location and the equipment found within the proprietary supervising station facility. c. The facilities procedures in handling alarm, supervisory, and trouble signals. d. The following procedures if a positive alarm sequence is provided: i. Describe whether positive alarm sequencing is to be utilized, whether an evacuation message will be played, or whether an investigation message will be played for the first 180 seconds after the receipt of a fire alarm signal. ii. Describe that an evacuation message will automatically activate per the fire alarm operational matrix after 180 seconds if the fire alarm system has not been reset. e. A copy of Appendix L from the Clark County Fire Code titled Fire Protection Systems Impairments and Systems Out of Service shall be incorporated into the SOP. 12. Upon receipt of a fire alarm signal, the proprietary supervising station operator shall initiate action to perform the following: a. Immediately dispatch runner to the alarm location identified on the fire alarm control unit. b. If the fire is verified, immediately activate the evacuation message on the fire alarm system and initiate notification procedures. c. If the alarm is false, the fire alarm system shall be reset. If either an investigation message or an evacuation message has been activated, then sound an all-clear message. 13. Upon receipt of a supervisory signal, the proprietary supervising station operator shall initiate action to perform the following: a. Immediately dispatch runner to the location identified on the fire alarm control unit, unless the supervisory conditions are promptly restored. b. If unable or unqualified to clear the supervisory signal, then personnel shall contact a fire alarm contractor within two hours to service the fire alarm system. Page 3 of 5

c. When fire protection systems are impaired, the procedures outlined in Appendix L of the Clark County Fire Code shall be performed. 14. Upon receipt of trouble signals or other signals pertaining solely to matters of equipment maintenance of the fire alarm system, the proprietary supervising station operator shall initiate action to perform the following, if required: a. Immediately dispatch runner to the location identified on the fire alarm control unit, unless the trouble conditions are promptly restored. b. If unable or unqualified to clear the trouble signal, then personnel shall contact a fire alarm contractor within four hours to service the fire alarm system. c. When fire protection systems are impaired, the procedures outline in Appendix L of the Clark County Fire Code shall be performed. 15. A written log of all fire alarm signals shall be maintained in the Fire Command Center including: a. The investigating person s name. b. The device address. c. The type of alarm. d. The date and time of receipt of the fire alarm signals. e. The cause and disposition of the fire alarm signals. 16. Any additional information determined necessary by the fire code official. PERMIT REVISIONS AND RESUBMITTALS: Revisions to approved plans are required to be submitted and approved. Revisions will be assessed additional plan review fees. A copy of the previously approved plan shall accompany the revised submittal to facilitate the review. Clearly indicate all changes to the revised plans by clouding the change with a delta number to signify the date of plan change. When several changes have been made, a detailed list of changes is required. Re-submittals to address a Letter of Correction will require a full submittal. These plans require a copy of the red lined plan from the previous submittal to facilitate the review. Clearly indicate all changes by clouding the change with the delta number to signify the date of plan change. PLANS CHECK STATUS INSTRUCTIONS: The status of the review can be checked by logging on to: www.clarkcountynv.gov/depts/fire INSPECTIONS THAT MAY BE REQUIRED AND SCHEDULING INSTRUCTIONS: If approved, an inspection will need to be scheduled. To schedule an inspection, also go to: www.clarkcountynv.gov/depts/fire. A fire inspector will review your site in Page 4 of 5

accordance with the approved plans and this guideline and, if compliant, will issue the permit. The Clark County Fire Department s Fire Prevention Division (FPB) may perform testing, acceptance, and maintenance of fire & life safety systems as required by and within the scope and authority of the Clark County Fire Code. This Guideline does not take the place of the Fire Code and does not take precedence over any Fire Code requirement or position taken by the Fire Chief. When a conflict exists between the requirements of this Guideline and the Fire Code or the opinion of the Fire Chief, the Fire Code or opinion of the Fire Chief prevails. Technical Assistance, when required by the Fire Chief, will require a Technical Opinion and Report prepared by a State of Nevada licensed: qualified engineer, specialist, laboratory, or fire safety specialty organization acceptable to the Fire Chief and the owner. The Fire Chief is authorized to require design submittals to bear the Wet Stamp and Signature of a professional engineer. Acceptance of Alternative Materials and Methods requires a Technical Opinion and Report prepared by a State of Nevada licensed: qualified engineer, specialist, laboratory, or fire safety specialty organization acceptable to the Fire Chief and the owner. The Fire Chief is authorized to require design submittals to bear the Wet Stamp and Signature of a professional engineer. Page 5 of 5