UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

Similar documents
Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems.

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

AIR HANDLING UNITS Vibration Isolation Air Filtration Equipment Ductwork.

1.1 This section applies to air handling units for HVAC Systems.

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS

HVAC REPAIR/REPLACEMENT 07/18/12 SECTION HVAC - MAJOR EQUIPMENT

A. Codes and Standards that are Standard at the University:

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS

Advance Release September 2009

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

SECTION FAN COIL UNITS

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

SECTION AIR HANDLING UNIT

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

SECTION AIR-COOLED SPLIT SYSTEM AIR CONDITIONING UNITS

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

A. This Section includes air-handling units with coils for indoor installations.

AIR HANDLER SPECIFICATION

University of Delaware

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise Modular Climate Changer Full Spec. Prepared by: Phone Number: Prepared for:

A. Section includes split-system air-conditioning units consisting of separate evaporator-fan and compressor-condenser components.

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup.

Direct Fired Heater Model AD Specification

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

SECTION COMPUTER ROOM AIR CONDITIONING SYSTEMS

SECTION AIR HANDLING UNITS WITH COILS. 1. Central Station Air Handling Units. 1. Section Basic Mechanical Requirements.

Modular Supply Make-Up Air Unit

A. American National Standards Institute (ANSI) : Establishes requirements applicable to certifying direct gas-fired heaters.

Product Specifications. Vertical Floor Consoles By First Co.

Submittal Data Performance Data Electrical Data

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS - CUSTOM

SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS

SECTION (15833) - HVAC POWER VENTILATORS

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

SKYPAK II, 3 Ton Series, gives you a

DARTMOUTH COLLEGE DESIGN March 15, 2003 & CONSTRUCTION GUIDELINES

SECTION CONVECTION HEATING AND COOLING UNITS

SECTION STEAM CONDENSATE PUMPS

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

SKYPAK II, 3 Ton Series, gives you a

MACH N-407 Heat Pump Air-Cooled Chiller

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March

Propeller Fans. Industrial And Commercial Fans Belt And Direct Drive. Your Clean Air Source!

Large Capacity Fan Coil Units Belt and Direct Drive Cabinet and Hideaway

1. Product Data for Prerequisite EQ 1: Documentation indicating that units comply with ASHRAE 62.1, Section 5 - "Systems and Equipment.

TYPICAL CPA SPECIFICATIONS

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories.

SECTION SPLIT-SYSTEM AIR-CONDITIONERS

RTU. Roof Top Units 8 30 Ton. Maxi-Kool.

Construction Standards Page

AIR HANDLING. B. Section Building Automation and Control System Guidelines. C. Section Air Cleaning Devices and Filters

AIR COOLED PACKAGED CHILLER

Large Capacity Fan Coil Units Catalog Belt-Drive and Direct-Drive Cabinet and Hideaway Models

PACKAGE AIR CONDITIONER

MAC N-407 Air-Cooled Chiller

.2 Section Waste Management and Disposal.

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

VERTICAL FAN COIL UNITS

Update In Progress. Division 23 Heating, Ventilation, and Air Conditioning Page Section FLUID SYSTEMS EQUIPMENT PART 1 GENERAL

SECTION AIR COOLED WATER CHILLERS

DIVISION 15 MECHANICAL

SECTION SPLIT-SYSTEM AIR-CONDITIONERS

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

SSL / SBS Sales Guide BLOWER-COILS REDUCED-FOOTPRINT, VERTICAL

SECTION WATER-SOURCE UNITARY HEAT PUMPS

Modular Heating & Ventilating Unit Model IGX-HV

SECTION CUSTOM INDOOR CENTRAL-STATION AIR-HANDLING UNITS For large systems, 50,000 cfm or more.

SeasonMaker ThinLine Fan-coil Units

Selecting the Correct Fan

C. Samples for Initial Selection: For units with factory-applied color finishes.

VSA SEWAGE PUMP. Capacities to 1600 gpm, Heads to 120, Horsepower range 3/4 thru 40, 3 thru 6 discharge, 1750 and 1150 operation.

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

Cabinet Unit Heaters Steam / Hot Water

Indirect Gas-Fired Make-Up Air

Chilled Water DOAS Fan Powered Terminal Units

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

SECTION AIR DUCT ACCESSORIES

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

EHH SERIES DRAW THROUGH FAN COILS CFM

SECTION AIR COILS

SKYPAK II Heating & Cooling Self Contained Packages

HiLine Vertical Stacking Fan Coils. Type FHSS and FHSK. Catalog

50TM COMBINATION HEATING/COOLING UNITS

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping.

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

University of Houston Master Construction Specifications Insert Project Name

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons

Transcription:

SECTION 15800 - AIR HANDLING EQUIPMENT 1.1 GENERAL A. All air handlers installed shall conform to the University of Rochester specification Guideline for Semi-Custom and Pre-Engineered Air Handling Units. If the Consultant believes this specification should be modified in anyway, he shall apply, in writing and providing whatever supporting information may be requested, to the Directors of Central Utilities and the effected Operations & Maintenance Group for a variance. B. No system shall be constructed which does not fully meet the functional needs of the area(s) being served as defined in the Architect s schematic design report. The equipment utilized, whether new or existing, must be compatible with the infrastructure (utilities) supporting it. When existing equipment is utilized, deficiencies and inefficiencies due to incompatibilities with the infrastructure shall be corrected. C. Modification or extension of existing systems must include calculation of the entire system's current capacities and demands (both supply and return). D. All new and renovated air handling systems shall be designed so that the draining of coils for freeze protection is not required. E. Systems shall be designed and operated to meet the latent heat gains of the area served. F. The primary chilled water control on air handling equipment will be the discharge air temperature of the unit set at the maximum necessary to meet the space requirements (including dehumidification). G. In all other applications (heat pumps, direct expansion systems, equipment, etc.) shall take their Chilled Water from the return. Flow will be controlled by the return water temperature at not less than 80 degrees unless approved in writing by the Director of Central Utilities. H. The maximum working pressure drop between the supply and return connections to the Chilled Water system shall be 15 psig. I. Project work must include rebalance of the entire system, both supply and return, it is a pressure independent system. 2.1 AIR CONDITIONERS A. Window air conditioners and domestic water cooled air conditioning units are generally not accepted as a means of air conditioning. All projects should make a concerted effort to use central utilities distributed services. B. Equipment must meet or exceed N.Y.S. Energy use guide lines. C. Unit shall not be supported from window frame, but from separate bracket supports. Unit shall be completely enclosed with galvanized sheet metal between outside bottom of air conditioning unit and window sill to eliminate nesting. 2.2 FAN COIL UNITS A. Shall be designed for combination heating and cooling units complete with cabinet, heating and cooling coil (separate coils), drain pan, fan(s), motor, fan plenum, grills, air filter(s), and return air grill. B. Unit Casing - Shall be fabricated from 18 gauge steel, insulated and sound proofed with glass fiber insulation, prime coat of baked-on enamel finish, removable panel for servicing. C. Fans - Shall be blow-through design, centrifugal wheels (aluminum or non ferrous), direct connected to motor shaft. Fan and motor shall be mounted on a 14 gauge steel support platform. Motor shall have built-in overload protection and provided with rubber isolation bases. Bearings shall be bronze sleeve type with oil reservoirs. Section 15800- Air Handling Equipment Page 1 of 5

D. Speed controller - Shall be controlled by two or three speed switch (Hi-Lo-Off or Hi-Med-Lo- Off), direct connected to fan motor. Temperature control shall be as specified with Powers, Johnson or Honeywell flow control valves. E. Coils and drain pan - Shall be provided with water heating and cooling coils, suitable for a working pressure of 200 psig, coils shall be installed at no greater than 30 degrees from vertical. Drain pan shall be fabricated from 18 gauge stainless steel (or equivalent material), insulated on all inside surfaces and pitched to drain port. A second drain pan shall be provided under the coil pan to catch condensate drips from coil end valves and piping. Drain pan connection 1 FPT connection min. F. Filter section - shall be removable throw away type with viscous impingement type of media. Filter shall have its own rack with holder lock. 2.3 UNIT HEATERS - PROPELLER TYPE A. Shall be provided complete with casing, coil, fan, motor, supports, temperature, electric, and safety controls. B. Rating shall be in accordance with ASHRAE standards and approved by the AMCA. C. Heating coils - shall be seamless copper tubing with copper or aluminum fins. D. For steam pressures over 100 psig the tubes shall be red brass, admiralty brass, or equal. Fins shall be mechanically bonded and be at least.0095 thick for aluminum or.008 thick for copper. Header shall be cast brass, cast bronze, copper or gray close grained cast iron. Coils shall be designed for 125 psig WSP, 200 psig OWG and 300 psig air pressure test under water. E. Casings - shall be stamped steel, with adjustable louvers, and shall be galvanized or bonderized with factory finish baked enamel. F. Fans - Shall be propeller type, direct connected to motor. Motor shall be single phase fractional horse power with thermal overload on capacitor, split phase or shaded pole type. G. Mounting - shall be from overhead building construction, rigidly affixed by minimum of two hangers and isolated from structure by means of double deflection rubber-in-shear vibration isolators. H. Thermostats - shall be furnished and installed for each unit heater, suitable for unit heater control. 2.4 CENTRIFUGAL WALL EXHAUSTER A. Shall be all aluminum construction, backward curved non-overloading wheel. B. Fan housing shall be aluminum or stainless steel with like exposed fastenings. C. The drive power assemblies shall be isolated from the housing, with the drive motor out of the air stream. D. Housings shall be removable for service access. E. Fan shall be provided with factory mounted, U.L. listed unfused disconnect, located in the motor compartment. F. Fan with wheels 12 inches and up shall be licensed to bear the AMCA seal. Section 15800- Air Handling Equipment Page 2 of 5

G. Motor - fractional horsepower size shall be capacitor, split phase, or shaded pole type with life time lubricated bearings. (single pole type) H. Grills and shutters - shall be provided and of same manufacturer as the fan. Bird guard shall be 1/2 spacing to comply with safety codes. Shutters shall be automatic closing, self opening type with bronze or nylon end shaft bearings. Shutter blades shall be felted and coupled together with tie rods. 2.5 PROPELLER FANS A. Shall be of steel construction with aluminum or steel blades and permanently lubricated bearings. B. Fan blades shall be of air foil design and licensed to bear the AMCA seal on fans 12 inches and larger. C. Panel Fans: Wheel Panel 12 and under 18 gauge steel 14 to 24 16 gauge steel 24 and up 14 gauge steel min. D. Panel shall be complete with deep throated orifice. E. Panel shall be galvanized or bonderized and have two coats factory applied baked enamel. F. Shutters and guards - shall be the product of the same manufacturer as the fan. Shutters shall be self-opening on discharge side complete with bronze or nylon bearings. Guards shall be provided on inlet side of fan, fabricated of 1/2 sq. wire spacing and meet OSHA standards. G. Motor shall be provided with a non-fused U.L. approved disconnect. Single phase fractional horse power motors shall be capacitor, split phase or shaded pole type. 2.6 ROOF EXHAUST FANS A. Where available, direct drive fan is preferred to minimize maintenance. B. Shall be provided with aluminum housing, strong enough to withstand a horizontal pressure of 30 lbs per square foot of projected area. Housing shall be provided with quick release catched for service access, (fan, motor, and bearings). Vibration isolators shall be provided to isolate all rotational movement and fan wheel shall be non-overloading type centrifugal fan of welded steel or aluminum construction statically and dynamically balanced. Ball bearings shall be grease-pack ball bearing pillow blocks. C. Drive - Shall be belt driven with cast iron or steel pulley and capable of adjustment 10% above or below specified speed. D. Motor - Shall be suitable for vertical shaft operation, equipped with non fusible U.L. listed disconnect, and shall be located out of the air stream, suitable for outdoor conditions. E. Dampers - shall be self-opening back draft dampers, with spring or counter balance return, located at top fan curb. Bearings shall be bronze or nylon bushings. Section 15800- Air Handling Equipment Page 3 of 5

F. Curbs - shall be prefabricated double shell insulated aluminum or galvanized 2 thick. Curb shall be manufactured out of min 18 gauge. G. Fan, curb and dampers shall be of same product manufacturer. 2.7 STANDARD AIR HANDLING FAN UNITS (Modular design & configuration typically 3000 20,000 cfm capacities) A. Fan units shall provide inspection ports and maintenance access opening for: Mixed air section Filter section Leaving side of the cooling coil Fan (and drive motor0 section Humidifier section Internal controls, safeties, control devices, etc. Air flow measuring station B. Units shall be structurally sound and support unit features including the added pressure and weight of maintenance personnel C. No through wall metal connection and properly insulated avoiding heat loss and condensation external to the unit. D. Air pressure testing or leak testing determine limits and test at factory or on site. Air leakage should not exceed ½ of 1 % airflow leakage at 1.5 times the operational static pressure. E. Utilization of ball bearing on damper ends or equal bear, resistance free mechanisms. Large damper sections actuated from a common driven shaft instead of sections driven and connected from damper blade to damper blade. F. De-stratification systems installed where air-mixing sections cannot proficiently de-stratify both air streams. Mixing sections do not necessarily completely mixed both air streams and therefore air temperature stratification exists. The mechanical contractor with his unit manufacture are responsible for eliminating potential air and flow stratification within the unit; not the controls contractor. Temperature stratification should not exceed =/- 5 F of average mixture temperature anywhere in the cross-sectional air stream of the unit. G. The filtration system and size shall be based on a life cycle analysis over a 5-year term for the pre/ mid, and finial filter sections. Stay with standard size filters ( 24 x 24 ). H. Determine if the fan system shall be draw through or blow threw with consideration to fan horsepower and the heat contributed to the discharge air temperature of the unit. I. Heating & cooling coil sections and specification as so noted in the Design Section of this document. J. All mechanical piping and unit features shall have access and drain ports installed to fully drain and burp air from the systems. K. All metals in direct contact with the cooling coil condensate shall be stainless steel or otherwise coated/protected with lifetime expectancy. Condensate pans shall be pitched to the drain(s); double pitched pans preferably. Drain connections shall be a size of 1- ¼ minimum. L. The chilled water cooling piping should have winterization scheme if the coil is left dormant over the winter season. A retrofit referred to as the Air Drying lay-up system is recommended if no other means has been offered other than simply draining the coil systems. The Facilities Section 15800- Air Handling Equipment Page 4 of 5

Departments connected to the central utilities cooling system is migrating from the use of glycoling cooling coils as a coil winterization means. M. The McMaster Bridge loop system required on all fan unit installations. Should exceptions arise, such as building McMaster Bridge loops, then as a minimum, each unit shall have a chilled water supply and return temperature sensor installed in the mechanical chilled water. N. Steam coil equalization across the condensate trap, typically called the vacuum breaker, shall not be vented to the ambient air. Breaking a vacuum with air introduces in-condensables in steam system hampering heat output, control, and introducing corrosives. The vacuum breaker piping shall extend down to the leaving side of the condensate trap securing the closed loop. A high temperature limit is installed in the piping between the trap connection and the vacuum breaker as a redundancy measure should the vacuum valve (check valve) fail or hang up. 2.8 HEATING AND COOLING COILS Reference Air Coils Design Standard 238216 END OF SECTION 15800 Section 15800- Air Handling Equipment Page 5 of 5