Emergi-Lite Orbis detectors

Similar documents
optical detector multisensor detector heat detector mounting bases product guide

ORBIS PRODUCT GUIDE. Optical Detector. Multisensor Detector. Heat Detector. Mounting Bases

CONTENTS NBM-06 Bell (6") Page 1

Series 65 Product Guide MAN 3036

EFBW series - BiWire Ultra control panel

4 wire conventional alarm system

System 800 Addressable Fire Detection & Alarm System

The new detector from Rafiki

Conventional Smoke Detectors KFAPO

Analogue addressable devices

Conventional Fire Detection

Evolution Analogue Addressable Fire System

VIMPEX BS Evacuation. Fire Alarms EN Banshee. Beacons. FlashDome. Electronic Sounders. Audible Alarm

Industries. As a premier global manufacturing company, we believe that great brands are

SERIES 65 ENGINEERING PRODUCT GUIDE

The complete conventional fire warning system

OPERATION AND INSTALLATION MANUAL

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

Cooper Industries (UK) Ltd

OH110, OP110, HI110 Automatic fire detectors

Intellia Sounder Bases and Sounder Beacon Bases

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

Xenex Conventional Fire Detection & Alarm System

Conventional Fire Control Panel (FKEP2, FKEP4, FKEP8) Operation and Maintenance Manual. Man-1078EL Issue 01 February 2014

FIREPRO INSTALLATION MANUAL FIRE ALARM CONTROL PANEL INSTALLATION MANUAL. Approved Document No. GLT Issue: 1. 8 Author: NRPJ Date: 7/ 3/201 4

Eaton is a global leader with expertise in:

Installation, Operating and Maintenance Manual

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

Fire-Cryer. Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX. Shaping Alarm Technology

Conventional Fire Control Panel

Fire Product Catalog

CONVENTIONAL >FIRE DETECTION C400 SYSTEM FIRE DETECTION

NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL

Orbis IS Product Guide MAN 3041

MINERVA MZX125 Digital Addressable Fire Detection System

Reflective Optical Beam Smoke Detector User Guide

Intelligent addressable fire alarm control panel

Fireray Application and. Installation Guide FEATURES. Range metres. 12V to 24V dc operation. Selectable alarm thresholds

Addressable Detectors & Bases

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

Product Guide MAN7030-2

Conventional Audible Visual Range

HART XL High Sensitivity Smoke Detection

An introduction to... Sigma

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

intelligent solutions

Addressable and Conventional Fire Protection

FIRE ALARM CONTROL PANEL. COMPLIES WITH EN54 part 2 & part 4 MEETS THE FUNCTIONAL REQUIREMENT OF BS:EN 5839 part 1 INSTALLATION MANUAL

Conventional Leaflets

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

SOUNDER BASES AND SOUNDER BEACON BASES

CATALOGUE. Request to Exit Products Relays, Fuses & Timers TROJAN DEVELOPMENTS Product Catalogue.

Control Panel Engineering and Commissioning Instructions

Fire Signalling. Signalling Solutions

Saffire User & Installation Manual. IMPORTANT This manual should be left with the panel after installation.

LF-4000 Series Conventional Fire Alarm Control Unit

ELECTRONIC SOUNDER STROBE Model : AVD-C407

SERIES 65 ENGINEERING PRODUCT GUIDE

The supplier and installer of the system should be approved by the local civil defence authority.

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

FSTP2-2-wire 2 Zone Conventional Fire Control Panel Operation and Maintenance Manual. Man-1078FS2 Issue 01 April 2012

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

ALK-V PHOTOELECTRIC SMOKE SENSOR

FSTP4-2-wire 4 Zone Conventional Fire Control Panel Operation and Maintenance Manual. Man-1078FS4 Issue 01 April 2012

Solution F2. Fire Alarm Control Panels one step ahead.

MINERVA MZX125. Digital Addressable Fire Detection System

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

DICTATOR Hold-Open Systems for Hazardous Areas

End To End Optical Beam Smoke Detector. Additional Information

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

Vega Devices.

Installation and Operating Instructions

Fire Signalling. Signalling Solutions

DUAL MONITORED INPUT/OUTPUT UNIT BN-305

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

Intelligent Security & Fire Ltd

Conventional Fire Alarm System 2014 V1.2

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Protec. Protec Algo-Tec TM 6500 Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network. Fire Detection - Addressable

2018 Johnson Controls. Tyco Fire & Security GmbH, Victor von Bruns-Strasse 21, 8212 Neuhausen am Rheinfall, Switzerland DUO-CEL

USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4

IFD-E Flame Detector User Manual

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

EUROFIRE Fire Control Panel

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER

D-Tect 2 GJD300 Quad PIR Movement Detector

FIRE CONTROL PANEL. Revision 1.1 January 1997 USER MANUAL. Emergi-Lite Safety Systems Ltd Bruntcliffe Lane Morley Leeds LS27 9LL

FIRE DETECTOR TYPE ED816 ZONE 5 ZONE 4 ZONE 6 ZONE 7 FIRE FIRE FIRE FIRE FAULT FAULT FAULT FAULT DISABLED DISABLED DISABLED DISABLED OFF OFF OFF OFF

SISTEMAS DE SEGURIDAD MIRA, S.L. COMPANY & PRODUCT GUIDE

Installation and Operation Manual

INFINITY 8 INSTALLATION MANUAL FIRE ALARM CONTROL PANEL INSTALLATION MANUAL

A GUIDE TO FIRE DETECTION AND ALARM SYSTEMS

Door Release Power Supply

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

IFD-E Flame Detector User Manual

Intelligent Security & Fire Ltd

TX7130. Conventional Reflective Beam Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

Application, Installation, Operation & Maintenance Manual

Transcription:

Emergi-Lite Orbis detectors Emergi-Lite Orbis brings the latest in fire detector microprocessor technology to the Firetec and Eurofire systems. Non-addressable (conventional) smoke and heat sensors respond to fire situations within a given zone, sending a signal to the fire panel, which will indicate a fire condition and sound the alarm. Orbis provides valuable core features, with high reliability, a marked reduction in unwanted false alarms, complemented by operational and maintenance enhancements. Features: StartUp: Correct installation a flashing red LED Continuity link: Zone wiring can be voltage tested before commissioning Wide-angle optics: Responsive to fires with black or white smoke Drift Compensation: Calibrated sensitivity levels are maintained despite contamination DustDefy: Dust ingress prevented while airflow is unimpeded Transient Rejection: Abnormal readings are filtered out to reduce false alarms DirtAlert: A flashing yellow LED will indicate when the drift compensation limit has been reached SensAlert: A flashing yellow LED indicates incorrect sensor operation Fast Test: A 4 second test confirms correct detector operation E-Z Fit slots: Remove and refit the base without dismounting the fixing screws Detector base with diode FAPO-TDB The standard detector base has a diode fitted beneath the connectors. A link feature enables voltage testing of zone wiring before commissioning. The base is a five terminal unit positive IN, positive OUT, Negative IN & OUT, remote LED negative and functional earth (screen) wire. Two fixing centre positions are provided at 51 and 60mm. Connectors accept up to 2.5mm 2 cables Dimensions ø d (mm) 100 x 15 60 FAPO-TDB Detector relay base FAPO-TRB The relay base has a single pole voltage free changeover contact for use to switch ancillary equipment. When the detector goes to alarm the relay is energised and changes state. Contacts rated at 30Vdc, 1A. Connectors accept up to 2.5mm 2 cables Dimensions ø d (mm) 100 x 15 60 FAPO-TRB 57 Emergi-Lite Orbis detectors Conventional

Emergi-Lite Orbis detectors Optical smoke detector FAPO-OPT The optical detector measures the level of smoke particles using light scatter, going to alarm at a pre-set threshold. New optics help reduce false alarms while stability is strengthened by using internal software control. Recommended for general purpose use to give early warning of fire. FAPO-OPT Average quiescent current at 24V 65µA Alarm current at 12V 24V Dimensions ø d (mm) 8.5 33Vdc 20mA 40mA 97 x 31 (100 x 46 inc base) 75, 135 with base Standards EN54-7: 2000 Optical smoke and thermally enhanced detector FAPO-MUS The detector uses optical and heat sensing technology in deciding when to trigger an alarm condition. The unit is designed as a smoke detector and cannot be switched from smoke to heat detection. This detector is more sensitive to fast burning, flaming fires than the optical model. Ideal for where heat is prevalent at an early stage in the fire. FAPO-MUS Average quiescent current at 24V 65µA Alarm current at 12V 24V Dimensions ø d (mm) 8.5 33Vdc Standards EN54-7: 2000 20mA 40mA 97 x 42 (100 x 57 inc base) 80, 140 with base 58 Conventional Emergi-Lite Orbis detectors

Emergi-Lite Orbis detectors Heat detectors Fixed temperature FAPO-HR1, FAPO-HR2, FAPO-HR3 The fixed (static) heat detector will trigger when a pre-set upper temperature threshold is exceeded at the sensor. Classification maximum application temperature: HR1 = 50ºC, HR2 = 65ºC, HR3 = 80ºC Average quiescent current at 24V 65µA Alarm current at 12V 24V 8.5 33Vdc 20mA 40mA Dimensions ø d (mm) 100 x 42 100 Standards EN54-5: 2000 FAPO-HR1 STANDARD ORDER CODE FAPO-HR1 FAPO-HR2 FAPO-HR3 DESCRIPTION Heat detector Fixed upper threshold 50ºC, A2S Heat detector Fixed upper threshold 65ºC, BS Heat detector Fixed upper threshold 80ºC, CS Heat detectors Rate of rise FAPO-RR1, FAPO-RR2, FAPO-RR3 The heat detector will monitor the rate of temperature increase in the vicinity and will also be triggered when a fixed upper threshold temperature level is exceeded. Readings are taken every 2 seconds, the stored values are compared against a preset value to decide if an alarm level has been reached. Classification maximum application temperature: RR1= 50ºC, RR2 = 65ºC, RR3 = 80ºC Average quiescent current at 24V 65µA Alarm current at 12V 24V Dimensions ø d (mm) 8.5 33Vdc Standards EN54-7: 2000 20mA 40mA 97 x 36 (100 x 51 inc base) 70, 130 with base FAPO-RR1 STANDARD ORDER CODE FAPO-RR1 FAPO-RR2 FAPO-RR3 DESCRIPTION Heat detector -Rate of rise with fixed upper threshold 50ºC, A1R Heat detector -Rate of rise with fixed upper threshold 65ºC, BR Heat detector -Rate of rise with fixed upper threshold 80ºC, CR 59 Emergi-Lite Orbis detectors Conventional

Conventional 4-wire detectors Conventional 4-wire detection: The FAP6 range Introducing the FAP6 range of detectors, for use with the Firetec and Eurofire 4-wire panels. FAP6 provides proven technology in a slim package, the concise range comprises optical and heat detectors (fixed and rate of rise temperature). In conjunction with Firetec the range is suited to small to medium sized buildings. Detector base with diode FAP6-STB The standard detector base has a diode fitted beneath the connectors. Connectors accept up to 2.5mm 2 cables Dimensions ø d (mm) 100 x 15 60 FAP6-STB Relay base FAP6-RLB The relay base incorporates a set of volt-free changeover contacts, which will latch when the detector registers an alarm. FAP6-RLB 9 33Vdc Relay base alarm current at 24V 17mA Modes Latching -20 to +70ºC Connectors accept up to 2.5mm 2 cables Dimensions ø d (mm) 100, 25 100 60 FAP6 is based on series 65 technology from Apollo Fire Detectors Ltd Conventional Conventional 4-wire detectors

Conventional 4-wire detectors Relay base, 12 volt FAP6-RLB12 The low voltage relay base incorporates a set of volt-free changeover contacts that can be used for either latching or non-latching (security system) purposes. To enable control of an automatic door closer, for example. 9 15Vdc Average quiescent current at 12V <10µA Relay base alarm current, at 12V 20mA Modes Latching or non-latching 20 to +70ºC Connectors accept up to 2.5mm 2 cables Dimensions ø d (mm) 100, 25 100 FAP6-RLB12 Optical smoke detector FAP6-OPT The optical detector measures the level of smoke particles using light scatter, going to alarm at a pre-set threshold. New optics help reduce false alarms while stability is strengthened by using internal software control. Recommended for general purpose use to give early warning of fire. 8.5 33Vdc Average quiescent current at 24V 65µA Alarm current at 12V 24V Alarm indication Dimensions ø d (mm) Standards EN54-7: 2000 20mA 40mA Clear LED, red on alarm -20 to +60ºC 100 x 42 (100 x 50 inc base) 99, 150 with base FAP6-OPT 61 Conventional 4-wire detectors Conventional

Conventional 4-wire detectors Heat detector fixed temperature FAP6-FT8 The fixed (static) heat detector will trigger when a pre-set upper temperature threshold is exceeded at the sensor. FAP6-FT8 Quiescent current at 24V Alarm current at 9V 24V Alarm indication Dimensions ø d (mm) 9 33Vdc <50µA 17mA 52mA Red LED 20 to +90ºC 100 x 42 (100 x 50 inc base) 80, 131 with base Standards EN54-5: 2000 Heat detector Rate of rise FAP6-RR6, FAP6-RR75, FAP6-RR90 The heat detector will monitor the rate of temperature increase in the vicinity and will also be triggered when a fixed upper threshold temperature level is exceeded. Classification maximum application temperature: RR6= 50ºC, RR75 = 65ºC, RR90 = 80ºC FAP6-RR6 9 33Vdc Quiescent current at 24V <50µA Alarm current at 9V 24V 17mA 52mA Alarm indication Red LED 20 to +90ºC Dimensions ø d (mm) 100 x 42 (100 x 50 inc base) 80, 131 with base Standards EN54-7: 2000 STANDARD ORDER CODE FAP6-RR6 FAP6-RR75 FAP6-RR90 DESCRIPTION Heat detector Rate of rise with fixed upper threshold 50ºC, A1R Heat detector Rate of rise with fixed upper threshold 65ºC, BR Heat detector Rate of rise with fixed upper threshold 80ºC, CR 62 Conventional Conventional 4-wire detectors

Conventional 4-wire call points Call point FMC-200R Surface mounted manually operated call point with LED indicator, providing a switch closure to the panel when operated. Features: Secure clip-fix front cover A single key for test, reset and removal of cover 24Vdc Impedance 470R series resistor Alarm indication Red LED -25 to +55ºC 4 way terminal block ABS plastic in red IP42 Dimensions lwd (mm) 87 x 87 x 53 (20 without back box) 190 Standards EN54-11 OPTIONS FMC-200RS Call point with re-settable plastic element FMC-10G Spare glass (pack of 10) FMC-10GRS Spare re-settable element (pack of 10) FMC-200R RSL800 Weatherproof call point FMC-200RWP Surface mounted manually operated call point with LED indicator, providing a switch closure to the panel when operated. Features: Secure clip-fix front cover One key for test, reset and removal of cover Weatherproof to IP67 24Vdc Impedance 470R series resistor Alarm indication Red LED 25 to +55ºC 4 way terminal block ABS plastic in red IP67 Dimensions lwd (mm) 110 x 110 x 65 290 Standards EN54-11 OPTION FMC-200RSWP Weatherproof call point with re-settable plastic element FMC-200RWP ACCESSORIES FOR FMC CALL POINTS FMC-KEY Spare test key (pack of 10) FMC-10G Spare glass (pack of 10) FMC-10GRS Spare re-settable element (pack of 10) FMC-PC Polycarbonate cover FMC-PCS Polycarbonate cover with security tie RSL800 Fire call point notice sticker SPARES FOR FMC INDOOR CALL POINTS FMC-BBR Back box in red FMC-BBW Back box in green For standard and weatherproof protective call point covers, see page 88. 63 Conventional 4-wire call points Conventional

Conventional 4-wire call points Call point FMC-800R Surface mounted manually operated call point, providing a switch closure to the panel when operated. Features: Secure clip-fix front cover A single key for test, reset and removal of cover FMC-800R 24Vdc Impedance 470R series resistor 25 to +55ºC 4 way terminal block ABS plastic in red IP42 Dimensions lwd (mm) 87 x 87 x 53 (20 without back box) 190 Standards EN54-11 OPTION FMC-800RS Call point with re-settable plastic element RSL800 Weather resistant call point FMC-800RWP Surface mounted manually operated call point, providing a switch closure to the panel when operated. Features: Secure clip-fix front cover One key for test, reset and removal of cover Weatherproof to IP67 FMC-800RWP 24Vdc Impedance 470R series resistor 25 to +55ºC 4 way terminal block ABS plastic in red IP67 Dimensions lwd (mm) 110 x 110 x 65 290 Standards EN54-11 OPTION FMC-800RSWP Weatherproof call point with re-settable plastic element 64 For standard and weatherproof protective call point covers, see page 88. ACCESSORIES FOR FMC CALL POINTS FMC-KEY Spare test key (pack of 10) FMC-10G Spare glass (pack of 10) FMC-10GRS Spare re-settable element (pack of 10) FMC-PC Polycarbonate cover FMC-PCS Polycarbonate cover with security tie RSL800 Fire call point notice sticker SPARES FOR FMC INDOOR CALL POINTS FMC-BBR Back box in red FMC-BBW Back box in green Conventional Conventional 4-wire call points

Conventional 4-wire call points/ancillary Key-switch operated call point FMC-2KSW A key-switch operated call point for use in secure premises where restricted access is needed. Suitable for use with 230Vac systems Operation 24Vdc Switch rating 10A, 24Vdc 2A, 230Vac 2 position keyswitch with 1 NO contact and 1 NC contact 25 to +55ºC Flying lead connections ABS plastic in red Dimensions lwd (mm) 87 x 87 x 20 190 Standards Fitting IP42, when fitted to a standard back box EN54-11 The 2KSW can be used with either a standard or a weather resistant back box. FMC-2KSW Remote Indicator unit FAP6-P10 A remote indicator is used to help an investigator quickly identify the location where a device has registered a fire, without having to gain entry to every room or inaccessible space. Features: Fire detector operated text LED indicator Red Terminal block IP rating IP42 Dimensions lwd (mm) 86.5 x 86.5 x 9 38 FAP6-P10 o Closed room space o Normal detection: Indicator visible Zone+ L1 in L1 out - R L1 in L1 out End of line device - R Zone +ve Zone -ve Remote LED indicator IN+ OUT+ LED- COM- LED- COM- IN+ OUT+ EOL Zone Corridor Solid door Vision panel in door Remote indicator Zone - Earth Note: A diode is normally fitted between L1 in & L1 out L2 L2 Note: A diode is normally fitted between IN+ & OUT- Example: Connecting a remote indicator to an FAP6 detector base (shown common across two detectors) in a zone Connection of remote LED unit to FAPO Orbis detector Illustration: Use of remote indicator in conventional fire system Ceiling tile mounting box FAP-MBCT The fixture is used to fit a detector or sounder into a false ceiling matrix. The devices can be pre-wired and tested before the ceiling is fitted. With the ceiling tiles in place, the MBCT assemblies can be slotted into place. STANDARD ORDER CODE FAP-MBCT-FD FAP-MBCT-SO DESCRIPTION Ceiling tile mounting box for detectors Ceiling tile mounting box for sounders 65 FAP-MBCT-FD Conventional 4-wire call points/ancillary Conventional

Conventional 4-wire alarms FACS Conventional 4-wire sounders, beacons and alarm bells Emergi-Lite Safety Systems offers a range of sounder and alarm options, for use with Firetec and Eurofire 4-wire panels. The table below highlights the key features of individual alarms to assist with planning and selection, when preparing a fire detection and evacuation system. PRODUCT CODE DESCRIPTION Features: Bell 6in diam Beacon Sounder Sounder: room / bedhead Sounder beacon Amber, Clear or Red lens Red. White or Grey body Visual LED IP rating 100 db(a) Integrated base Accessories 32 Tone range Page reference FACS-5W Sounder base W 67 FACS-5TPR Sounder base cap R 67 FACS-5TPW Sounder base cap W 67 FACS-1R Sounder R 67 FACS-1RL Sounder R 67 FACS-1W Sounder W 67 FACS-1WL Sounder W 67 FACS-BBR Back box for FACS1R R 67 FACS-BBW Back box for FACS1W W 67 FACS-4R Sounder R 68 FACS-4RDB Sounder R 65 68 FACS-4W Sounder W 68 FACS-4WDB Sounder W 65 68 FACS-8R Sounder-beacon R R 68 FACS-8RDB Sounder-beacon R R 65 68 FACS-8RDB-A Sounder-beacon A R 65 68 FACS-8W Sounder-beacon R W 68 FACS-8WDB Sounder-beacon R W 65 68 FACS-BEA-R Beacon R R 69 FACS-BEA-RDB Beacon R R 65 69 FACB-624 Bell R 69 FACB-624-G Bell G 69 FAAB-624-WP Bell R 55 70 66 Conventional Conventional 4-wire alarms

Conventional 4-wire alarms Low profile sounder FACS-5W A low height sounder that can be used standalone with an optional cover or as a platform for a smoke/heat detector with a detector base. Features: Four selectable tones including warble, pips and sweep 8 35Vdc Current draw @ 24Vdc 11mA Sound output, at 1m (dba) 91 (94 with cover plate) No. of tones 4 Operating frequency 800Hz to 1Khz 20 to +70ºC Terminal block Cable entry Rear ABS plastic IP43 (DB version - IP65) Dimensions ø h (mm) 106 x 25 (35 with cover) 121 OPTIONS FACS-5TPW White cover FACS-5TPR Red cover FACS-5W FACS-5TPW Room sounder FACS-1R A room sounder, suitable for bedroom and passageway use. Features: Low profile with a small footprint Audio/visual version with flashing LEDs on alarm Four selectable tones including warble, pips and sweep 8 35Vdc Current draw @ 24Vdc 11mA Sound output, at 1m (dba) 97 No. of tones 4 Volume control -50dBA Operating frequency 800Hz to 1Khz -20 to +70ºC Terminal block Cable entry Rear (or side entry with surface box) ABS plastic IP43 Dimensions lwd (mm) 86.5 x 86.5 x 9 (+25.2 back box or recessed) 103 OPTIONS FACS-1RL Room sounder, red, with two flashing hi-intensity LEDs FACS-1W Room sounder, white FACS-1WL Room sounder, white, with two flashing hi-intensity LEDs FACS-BBR Back box for FACS-1R FACS-BBW Back fox for FACS-1W FACS-1R 67 Conventional 4-wire alarms Conventional

Conventional 4-wire alarms Open area sounder FACS-4R A multi-tone sounder for open area use, operating across a range of frequencies. Features: Quick fit installation 32 tones, selectable by DIL switch High, medium and low outputs can be selected to fit in with a local sound pattern requirement Side grub screw for security locking FACS-4R FACS-4RDB 15 35Vdc Sound level Low Med Hi Current draw @ 24Vdc <9mA <18mA <36mA Sound output, at 1m, 1st tone (dba) 91 106 111 No. of tones 32 Operating frequency 440 to 2900Hz 20 to +70ºC Terminal block Cable entry Rear (DB rear or side entry [with cover plate]) ABS plastic IP43 (DB version - IP65) Dimensions ø h (mm) 93.6 (DB-93) x 84.3 (DB-101.6) 220 (DB-250) OPTIONS FACS-4RDB Open area sounder, red, deep base FACS-4W Open area sounder, white, shallow base FACS-4WDB Open area sounder, white, deep base 68 FACS-8R FACS-8RDB Open area sounder beacon FACS-8R A multi tone sounder-beacon, for open area use. Features: LED cluster beacon light 32 tones, selectable by DIL switch Enables compliance with the Disability Discrimination Act (DDA) Side grub screw for security locking 15 35Vdc Sound level Low Med Hi Current draw @ 24Vdc <14mA <20mA <41mA Sound output, at 1m, 1st tone (dba) 88 103 109 No. of tones 32 Operating frequency 440 to 2900Hz 20 to +70ºC Terminal block Cable entry Rear (DB rear or side entry [with cover plate]) ABS plastic, with red lens IP43 (DB version IP65) Dimensions ø h (mm) 93.6 (DB-93) x 89.6 (DB-106.9) 233 (DB-258) OPTIONS FACS-8RDB Open area sounder, red, deep base FACS-8W Open area sounder, white, shallow base FACS-8WDB Open area sounder, white, deep base FACS-8RDB-A Open area sounder, red, deep base with amber cover Conventional Conventional 4-wire alarms

Conventional 4-wire alarms Alarm beacon FACS-BEA-R A bright output flashing beacon to augment sounders, particularly in areas of higher ambient noise. LED light source with low power requirement. 20 35Vdc Set up Standard Low Current draw @ 24Vdc 5mA 3mA Light output (equiv) @24Vdc 0.7w 0.4w Operating frequency 1Hz 20 to +70ºC 6 way angled terminal block Cable entry Rear (DB - rear or side entry) ABS plastic in red IP43 (DB version - IP65) Dimensions ø h (mm) 93.6 (DB-93) x 60.2 (DB-77.1) 145 OPTION FACS-BEA-RDB Alarm beacon, deep base FACS-BEA-R FACS-BEA-RDB Alarm fire bell FACB-624 A wall mountable motorised fire bell for fire alarm or class change. The gong is secured by a tamper resistant bolt. 18 28Vdc Current draw @ 24Vdc 25mA Sound output, at 1m (dba) 96 10 to +55ºC 4 way terminal block Cable entry Rear (or side entry with surface box) Metal gong in red IP42 Dimensions ø h (mm) 150 x 54 527 OPTION FACB-624-G Alarm fire bell with grey gong FACB-624 69 Conventional 4-wire alarms Conventional

Conventional 4-wire alarms Alarm fire bell FAAB-624-WP A wall mountable fire bell for fire alarm or class change applications. Weather resistant rating achieved with a rubber gasket. FAAB-624-WP 18 30Vdc Current draw @ 24Vdc 30mA Sound output, at 1m (dba) 93 95 10 to +55ºC 4 way terminal block Cable entry Rear (or side entry with surface box) Metal gong in red, base in polycarbonate IP55 Dimensions ø h (mm) 150 x 85 1,100 70 Conventional Conventional 4-wire alarms