HGM-MZ Halogen Gas Monitor Multi Zone

Similar documents
Gas Monitor Multi Zone

HGM-RD Remote Display Module: Refrigerant Gas Monitoring System

HGM-RD Remote Display Module for Refrigerant Gas Monitoring System

SECTION 1 (Page 2) Introduction, standard accessories and mounting specifications.

MZ-RD Remote Display. Instruction Installation / Operation / Maintenance. Rev. 6 December 2011

Rev 4 12-APR IRLDS II and IRLDS II User Interface Installation and Operation Manual

CO2MSZ Carbon Dioxide Gas Monitor Single Zone

HGM300/RDM800 PREVENTATIVE MAINTENANCE AND TECHNICAL SUPPORT. SECTION 1 HGM300 CPU reset, RDM800 CPU reset, WARM UP notes and HGM300 Self Test

MultiZone Gas Monitors

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

Controllers. Instruction Manual WARNING

Remote Relay Module (RRM)

PGM-IR Halogen Monitor Bagless Portable Gas Monitor for Halogen Gases (Refrigerants)

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

Instruction Manual WARNING

Figure 1. Figure 2. See notes 1 and 2 below.

Model OEM-2 INSTRUCTIONS FOR USE

SAFETY INFORMATION AND WARNINGS

TMC. Installation and Operation Manual TMC. Temperature and Pressure Monitoring for Heating and Cooling Applications. Temperature Monitoring Control

FLCH4R Garage and Utility Electric Heater

IT COULD FAIL TO PERFORM AS DESIGNED AND PERSONS WHO RELY ON THIS PRODUCT FOR THEIR SAFETY COULD SUSTAIN SEVERE PERSONAL INJURY OR DEATH.

Installation and Operations Manual

Rev Pulse Modulating Anti- Sweat Control (PMAC II) Installation and Operation Manual

Alnor AirGard 410HE Air Flow Monitor for Hazardous Environment Fume Hoods

Pre-March 2016 Design - Click to be redirected to newer SBS-H2 design SBS-H2. Hydrogen Gas Detector Kit

Installation Guide Bacharach Communications Adapter HGM-MZ to Johnson Controls Metasys N2 Network (Electrically Isolated N2 Port Version)

Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector

SCAN200E USER S MANUAL

Installation, Operation & Service Manual

Section PERIMETER SECURITY SYSTEMS

PGM-IR Halogen Monitor

Operations Manual TS400. Test Station for G450/G460 Gas Detector

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

Carbon Monoxide Transmitter

21-light Remote Annunciator. Owner s Manual

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

INSTALLATION AND OPERATION MANUAL ENVIRONMENTAL SYSTEM IR-SNIF-MCD MODELS MCD-1, 4, 8 & 16

Public Safety DAS Annunciator Panel

THIS MANUAL MUST BE CAREFULLY READ BY ALL INDIVIDUALS WHO HAVE OR WILL HAVE THE RESPONSIBILITY FOR USING, MAINTAINING OR SERVICING THIS PRODUCT.

RC-2000 Thermostat Installation Instructions

Danfoss gas detection units

Model 405 AIRGARD Fume Hood Monitor

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

Static Pressure Alarm For Hazardous Location Fume Hoods

Beacon 410A Gas Monitor Operator s Manual

HALOGUARD IR MULTI-POINT, COMPOUND SPECIFIC MONITOR INSTRUCTION MANUAL

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

P2267 NETWORK INTERFACE

1228s Multidrop INSTRUCTIONS. Installation and Operation of the AMC-1228s Electrochemical Sensor Module For Use With Multidrop AMC Monitors

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES

RAM3 Remote Alarm Module

Pioneer-R16 Gas Monitor Operator s Manual

Beacon 800 Gas Monitor Operator s Manual

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

AMC-RAM-4. Refrigerant Alarm Module USER MANUAL. Please read the installation and operating instructions completely and carefully before starting.

Sintrol Snifter A2 EX. Manual. Version 1.2.3

! "! # Please read these installation and operating instructions completely and carefully before starting.

Duct and Rough Service Carbon Monoxide Sensor

Macurco HD-11 Hydrogen Gas Detector

GG-R REFRIGERANT SENSOR. Installation and Operation Manual

Installation Guide. Bacharach HGM300 to LonWorks FT-10 Communications Adapter

ion Genesis Pump Controller

Chore-Tronics Load Cell Indicator

CIRRUS PRO. User Manual and Responsibilities ASPIRATING FIRE DETECTOR

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Instruction Bulletin

Warranty Registration

Macurco HD-11 Hydrogen Gas Detector User Instructions. Important: Keep these User Instructions for reference

Networked Access Control Panel. Installation Guide

CO Guardian LLC Document: E. AIRPORT DRIVE Date: 11/15/05 OWNERS MANUAL

SEC 2000 Millenium Infrared Gas Detector

Mark 25 Ultrapure Water Conductivity Analyzer

Multi-Gas-Controller MGC2

EXPERT TRI-STAR. Temperature controller. User s Manual

Flostop TS D7E and A8E. Operation Manual

Document No

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS

NEUTRONICS MINI ID R-1234yf REFRIGERANT IDENTIFIER OPERATION MANUAL

PGM-IR CO 2 Monitor. Instruction Operation and Maintenance. Portable Gas Monitor for Carbon Dioxide (CO 2 ) Gas. Rev.

Flopurge TS. Operation Manual

TAG MR VOLTAGE DETECTORS AND ACCESSORIES. Instruction & Operation Manual

Danfoss gas detection units

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler

Water heating for your PV system. Installation and user guide. v1.1

FIRERAY 5000 range USER GUIDE

Two-Channel Gas Controller

C-Bus Pascal Automation Controller 5500PACA. Installation Instructions

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

INSTALLATION INSTRUCTIONS TALKBACK MODULE

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Ammonia Leak Detector Manual

OKB, OKD, & OKH Series

AFA 500 FUME HOOD ALARMS

Snifter ATEX22 VERSION. User Manual. Distributor

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

Transcription:

Halogen Gas Monitor Multi Zone HGM-MZ Halogen Gas Monitor Multi Zone Instruction 3015-5074 Installation / Operation / Maintenance UL 61010-1 CAN/CSA 22.2 No.61010.1 Rev. 0 Preliminary November 2008 Product Leadership Training Service Reliability

WARRANTY Bacharach, Inc. warrants to Buyer that at the time of delivery this Product will be free from defects in material and manufacture and will conform substantially to Bacharach Inc.'s applicable specifications. Bacharach's liability and Buyer's remedy under this warranty are limited to the repair or replacement, at Bacharach's option, of this Product or parts thereof returned to Seller at the factory of manufacture and shown to Bacharach Inc.'s reasonable satisfaction to have been defective; provided that written notice of the defect shall have been given by Buyer to Bacharach Inc. within two (2) years after the date of delivery of this Product by Bacharach, Inc. Bacharach, Inc. warrants to Buyer that it will convey good title to this Product. Bacharach's liability and Buyer's remedy under this warranty of title are limited to the removal of any title defects or, at the election of Bacharach, to the replacement of this Product or parts thereof that are defective in title. The warranty set forth in Paragraph 1 does not apply to parts the Operating Instructions designate as having a limited shelf-life or as being expended in normal use (e.g., filters). THE FOREGOING WARRANTIES ARE EXCLUSIVE AND ARE GIVEN AND ACCEPTED IN LIEU OF (I) ANY AND ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE: AND (II) ANY OBLIGA- TION, LIABILITY, RIGHT, CLAIM OR REMEDY IN CONTRACT OR TORT, WHETHER OR NOT ARISING FROM BACHARACH'S NEGLIGENCE, ACTUAL OR IMPLIED. The remedies of the Buyer shall be limited to those provided herein to the exclusion of any and all other remedies including, without limitation incidental or consequential damages. No agreement varying or extending the foregoing warranties, remedies or this limitation will be binding upon Bacharach, Inc. unless in writing, signed by a duly authorized officer of Bacharach. Register your warranty by visiting www.bacharach-inc.com Declaration of Conformity Manufacturer s name: Manufacturer s address: Product Name: Bacharach, Inc. 621 Hunt Valley Circle New Kensington, PA 15068 HGM-MZ (Halogen Gas Monitor) European EMC Directive 2004/108/EC EN55011 Emissions Product Specific Standard EN61326-1 Immunity Product Specific Standard EN61010-1 Safety requirements for Electrical Equipment For Measurement, Control, and Laboratory Use-Part 1: General Requirements Notice: Product improvements and enhancements are continuous; therefore the specifications and information contained in this document may change without notice. Bacharach, Inc. shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. No part of this document may be photocopied, reproduced, or translated to another language without the prior written consent of Bacharach, Inc. Copyright 2000 2008, Bacharach, Inc., All Rights Reserved BACHARACH is a registered trademark of Bacharach, Inc. All other trademarks, trade names, service marks and logos referenced herein belong to their respective owners. A Instruction 3015-5074

Table of Contents Halogen Gas Monitor Multi Zone 1 INTRODUCTION... 5 How to Use This Manual... 5 Warning Statements... 5 Caution Statements... 5 Hazard Symbols on Monitor... 5 Safety Precautions... 6 AC Power Supply... 6 Protective Grounding... 6 Explosive Atmosphere... 6 Proper Exhaust Venting... 6 Working Inside the Monitor... 6 Misuse and Modifications to the Instrument... 6 In Case of Malfunction... 6 Fusing... 6 Installation Category... 6 Altitude Limit... 6 Cleaning... 6 Functional Overview... 7 General Description...7 Communication Options... 7 Understanding Monitoring Levels... 7 Response to the Presence of Multiple Refrigerants... 7 Suggested Location of Sampling Points... 7 2 INSTALLATION... 9 Installation Considerations... 10 Warnings and Cautions... 10 Inspection... 10 Locating the Monitor... 10 Mounting Instructions.... 11 Connecting Air Lines... 12 Overview... 12 Tubing Considerations... 12 Connecting Purge Line... 12 Connecting Exhaust Line... 12 Connecting Sample Intake Lines.... 12 Interior Schematic... 14 Electrical Wiring... 17 Connecting Communication Devices... 17 Remote Display Module (HGM-RD) Connection... 17 Integrating with Building Management Systems (BMS)... 17 Larger Integrated Systems... 17 Changing Terminator Switch Settings... 18 HGM Node Address Dip Switch Settings... 18 Personal Computer... 18 Multiple HGMs... 19 Multiple HGM-MZs with HGM-RD... 19 RS-485 Connections Between HGM-MZs... 19 Connecting to a Building Management System (BMS)... 19 PC Software... 20 Saving the HGM-MZ Program to a Disk or Drive... 21 Opening a Saved Program... 21 Sending a Saved Program to an HGM-MZ... 21 Trend Data... 21 Converting the TREND Text File to a Microsoft Excel File... 21 Saving & Printing the HGM-MZ Software Screen, Alarm Log, Fault Log, or Diagnostic Screen... 21 USB Type Laptops... 22 Current Loop Interfaces... 23 Instruction 3015-5074 1

Optional 4-20 ma DC Outputs... 23 Connection... 23 Connecting External Alarms... 24 Overview... 24 Connection... 24 3 SETUP PROGRAMMING... 26 Display Screens... 26 Initial Power Up... 26 Data Display Screen... 26 Navigating to the 1 st Setup Screen... 26 Navigating to the 2 nd Setup Screen... 27 Location... 27 Number of Zones Installed... 27 Alarm Ack Mode... 27 Audible Alarm... 27 Zone Hold Time... 29 Detection Limit... 29 Loop2 Factor... 29 Re-Zero Mode... 29 Navigating to the 3 rd Setup Screen... 30 Service Timeout... 30 Node Address... 29 Password... 29 Accessing Additional Features... 30 DET Digipot... 30 Sensor Temperature Coefficient... 30 Acquiring Temperature Coefficient... 30 IR Digipot... 30 4 GENERAL OPERATION... 31 Functional Overview....31 The Zone Screen....31 Location....31 Refrigerant Type....31 Distance....32 Zone Temperature....32 Current Detection Reading....32 Log Interval....32 Navigating to the 2 nd Zone Screen....32 Leak Level....33 Spill Level....33 Evacuation Level....33 Re-Setting the peak PPM value....33 Alarm Conditions....33 Fault Conditions....33 Alarms....33 Functional Overview....33 Responding to Alarms....34 Alarm Detail Screen....34 Acknowledging Alarms....35 System Faults....35 Functional Overview....35 Navigating to the Fault Screen....36 Critical Faults....36 Non-Critical Faults....36 Reset to Factory Default Settings....37 Clearing System Faults....37 Viewing Fault Log....37 Viewing Flow Log....38 The Trend Screen....39 Navigating to the Trend Screen....39 2 Instruction 3015-5074

The Calibration Screen....39 Overview....39 Navigating to the Calibration Screen....40 Adjusting Calibration Factor....40 Calibration Procedure....40 Programming New Gases....41 The Diagnostic Screen....42 Navigating to the Diagnostic Screen....42 Diagnostic Screen Overview....42 Service Mode....43 5 MAINTENANCE....44 Warnings and Cautions....44 Servicing Primary Filter....44 Charcoal Filter....44 Servicing Air Lines & Replacing Termination Filters....44 Replacing Fuses....44 Clock Battery....44 Sample Pump... 44 Intake Manifolds....45 4-20 madc Interface Board....45 Replacement Parts & Optional Accessories....46 Specifications....47 APPENDIX A....48 Recommended Alarm Settings....48 APPENDIX B....49 RS-485 Communication Protocol....49 HGM-MZ MODBUS RTU Operation....49 Overview....50 Protocol Details....50 Notes on MGM-MZ Polling....50 Notes on Network Topologies....50 Key Comm Protocol Parameters....51 Summary of Registers....52 System Data Register....53 Status Register....54 Zone Data....55 Notes on Alarm & Alarm Acknowledge....56 Date Time Register....57 Sensor Data Register....57 Release Zone Hold Register....58 Hold Zone Register....58 HGM-MZ Hold Mode....58 Fault Log Register....59 Flow Log Register....59 Alarm Log Register....59 Service Mode Register....59 Release Service Mode Register....60 PPM Register....60 Zone Log Register....60 Modbus Exception Response....61 APPENDIX C....62 HGM-MZ System Map....62 Instruction 3015-5074 3

This page intentionally left blank. 4 Instruction 3015-5074

1 Introduction About This Manual Thank you for investing in a Bacharach HGM-MZ Refrigerant Gas Monitor. To assure operator safety and the proper use of the HGM-MZ please read the contents of this manual, which provides important information on the installation, operation, and maintenance of the monitor. If you have a working knowledge of refrigerant monitors, you will find this manual useful as a reference tool. If you are new to the use of refrigerant monitors, this document is educational in the principles of refrigerant gas detection and the proper operation of this device by reading this manual thoroughly. This manual provides important information about the installation, operation, and servicing of the HGM-MZ Refrigerant Monitor and HGM-RD Display Module. Warning Statements The use of the word WARNING in this manual denotes a potential hazard associated with the use of this equipment. It calls attention to a procedure, practice, or condition, or the like, which if not correctly performed or adhered to, could result in personal injury or death. Caution Statements The use of the word CAUTION in this manual denotes a potential hazard associated with the use of this equipment. It calls attention to a procedure, practice, condition, or the like, which if not correctly performed or adhered to, could result in damage to the equipment. Hazard Symbols on Monitor This symbol indicates the need to consult this operating instruction manual when opening the enclosure. WARNING: A potential risk exists if the operating instructions are not followed. This symbol indicates the presence of electric shock hazards when the enclosure is opened. WARNING: To avoid risk of injury from electric shock, do not open the enclosure without first disconnecting AC power. Instruction 3015-5074 5

Safety Precautions Halogen Gas Monitor Multi Zone AC Power Supply The HGM-MZ uses a universal power supply that is capable of accepting inputs of 100 to 240 VAC, 50/60 Hz. The monitor s power consumption is 20 Watts. It is highly suggested that the monitor be connected directly to the AC power source, preferably on its own circuit (with UPS or surge protection). A switch or circuit breaker rated 1.0 A, 250 VAC, with a minimum terminal spacing of 3.0 mm must be attached to the monitor s AC power leads. This switch must also be located in close proximity to the monitor, and be in easy reach of the operator. This switch should also be clearly marked as the monitor s type of equipment. Protective Grounding Under no circumstances should the HGM-MZ be operated without connection to a protective ground. Doing so poses a potential shock hazard and is also a violation of electrical safety standards applicable to this type of equipment. Explosive Atmosphere Do not operate this equipment in the presence of flammable liquids, vapors or aerosols. Operation of any electrical instrument in such an environment constitutes a safety hazard. Proper Exhaust Venting It is imperative that the exhaust port on this instrument be properly vented as described in this manual. Failure to do so may constitute a safety hazard. Accessing the Interior of the Monitor Extreme care should be exercised when accessing the interior of the monitor. Only qualified electrical maintenance personnel should perform connections and adjustments. Always remove AC power before opening the monitor s enclosure. Misuse and Modifications to the Instrument The protection provided by the monitor may be impaired if the monitor is used in a manner not specified by Bacharach, Inc. Modifications to this monitor, not expressly approved, will void the warranty. In Case of Malfunction Do not continue to use this equipment if there are any symptoms of malfunction or failure. In the case of such occurrence, de-energize the power supply and contact a qualified repair technician or the nearest Bacharach Service Center. Use ONLY the provided knockouts for electrical and communication wiring. Drilling into the box will void the warranty. Fusing F1, F2: 1.0 A, 250 VAC, Type F Installation Category Installation Category II, Pollution Degree II, as defined by UL. Altitude Limit 6,562 ft (2,000 m) Cleaning To clean the outside of the case use a DRY CLOTH. To avoid shock hazard and/or equipment damage, DO NOT use soap and water. 6 Instruction 3015-5074

Functional Overview General Description Halogen Gas Monitor Multi Zone Refrigerant monitors are specified to support compliance to federal, state and local safety codes governing refrigerant emissions. Avoiding significant refrigerant loss reduces equipment replacement costs, maintains equipment efficiency, promotes safety, and protects the environment. The Bacharach HGM-MZ provides continuous monitoring of refrigerant gas levels in up to 16 separate test zones. The instrument is easily programmed to monitor a variety of gasses and independent leak (small), spill (medium), and evacuation (large) levels may be designated for each zone. The instrument also retains a log of previous readings that can be easily accessed for analysis. An audible alarm and front panel indicators are provided to signal alarm and fault conditions, and relay contacts are provided that can be used to trigger external alarm devices in the event of a system fault, or if a leak (small), spill (medium), or evacuation (large) level of gas is detected. The system also may be fitted with and optional two channel 4-20mA current loop board for connection to remote monitoring equipment. The HGM-MZ requires only minor periodic maintenance such as the occasional replacement of filters. The monitor incorporates active diagnostics that continuously check the system for proper operation. A front panel indicator is provided to alert an operator of system malfunctions, and fault codes are generated that enable the user to identify the cause of the fault. Communication Options The HGM-MZ features full two-way communications via an RS-485 interface. MODBUS RTU is the communication protocol standard. The instrument can be connected directly to a Building Management System or it may be operated as a stand-alone system. An RS-232C port is also provided for connection to a PC. This enables the HGM-MZ to be setup from a personal computer. Please refer to the Appendix for a more complete discussion of communication protocols. Understanding Monitoring Levels Effective use of this instrument requires an understanding of what constitutes reasonable alarm set points for the types of gasses monitored. Refrigerant manufacturers define allowable exposure levels and threshold limit values in units of parts per million (ppm). In a good tight installation these background levels will be acceptably low and often do not require corrective action. You can reduce nuisance alarms and needless service calls if the alarm levels are set at practical limits. Bacharach has developed recommended monitoring levels based on compliance to ANSI/BSR ASHRAE 15-1994 and ASHRAE Safety Code 34-1992. These reference levels are listed in the Appendix. Setting the monitor at these recommended alarm levels will satisfy the needs of most users. However, the ppm levels generated by system leaks into the environment are greatly influenced by the volume of air in the sampling area, air circulation, size of the leak, distance to the monitoring point, and a host of other variables. In some cases the set points may need to be adjusted either up or down to achieve effective monitoring. Response to the Presence of Multiple Refrigerants The HGM-MZ is a refrigerant level monitor, not a gas analyzer. You must program the monitor to test for a specific refrigerant, and it will only return accurate concentration readings for that particular refrigerant. If a leak occurs of another refrigerant gas type, the monitor may return incorrect readings. Most applications only require detection of a single refrigerant and the problems that are associated with monitoring multiple gases are rarely an issue. If there is a possibility of multiple refrigerants leaking in the same sampling zone, then you should carefully consider which refrigerant compound you program the unit to monitor. Suggested Location of Sampling Points At the point of a refrigerant leak the gas is nearly pure. As the refrigerant is dispersed into the air, the gas molecules diffuse, causing a dilution of the original concentration. The HGM-MZ measures the refrigerant concentration at the sample collection point. Therefore, if the termination of the collection line is not at the exact point of the refrigerant leak, the unit will read a diluted mixture of the refrigerant gas and air. Instruction 3015-5074 7

It should also be noted that refrigerant gas is heavier than air and tends to collect below the point of a leak. Therefore a sample taken near the floor will have a greater concentration of gas than that collected above the source of a leak. Therefore, sampling points should be located as close as possible to the sources of potential leaks. If this is impractical, then the alarm set points should be adjusted for that zone to compensate for the dilution of the refrigerant gas. Sample inlet filters should be mounted 12-18 above the floor. DO NOT block any of the zones. Unused zones may be disabled by setting the distance parameter to zero feet in the zone setup screen. The HGM-MZ should be centrally located in the mechanical room and be readily accessible for easy visual monitoring and servicing. The combined length of sample tubing, plus exhaust tubing, should not exceed 1200ft. for any zone. The fresh air purge line should draw from an area that does not contain any refrigerant gas and cannot exceed 300 feet in length. The exhaust line should run to an outside location if possible. The length of the exhaust line cannot exceed 300 feet. Ideally, two to three pick up points spaced around each chiller will provide sufficient coverage. It may be necessary to perform a smoke test of the mechanical room to determine the best locations. The smoke test would provide the pattern of air currents present in the mechanical room. HGM-MZ / HGM-RD Refrigerant Gas leak Monitor Mechanical Room Placement Sample Inlet Pickup Point Exhaust Fan Outside Hallway Auxiliary Horn/Strobe Fresh air purge from area away from refrigerant gas HGM-RD Remote Display Module outside of mechanical room Machine Room Chiller HGM-MZ Halogen Gas Monitor Sample Inlet Pickup Points The HGM-RD should be mounted outside of the mechanical room, or just inside the room s doorway if the first option isn t possible. This is the split architecture design for safety of the operator. The HGM-RD can be located up to 4500 feet from the HGM-MZ. The HGM-RD is the man machine interface by which you program the HGM-MZ, acknowledge alarms and observe conditions inside of the mechanical room. Note that there are two additional alarm relay contacts in the HGM-RD that can be programmed to alarm with leak, spill, evacuate, fault or monitor on. 8 Instruction 3015-5074

Halogen Gas Monitor Multi Zone 2 Installation HGM-MZ Front View Display Screen Solenoid Connections LED Indicators RED: Alarm YELLOW: System fault GREEN: Monitor is powered on *Open cover for mounting instructions (page11) Standard Accessories for a 4-Point System 5 Line-End Filters (P/N 3015-3420) Charcoal Filter (P/N 3015-3125) T-Bolt Bracket (P/N 3015-2969) HGM-MZ Instruction Manual (P/N 3015-5074) Instruction 3015-5074 Bacharach, Inc. 9

Installation Considerations Warnings & Cautions WARNING: Explosion hazard! Do not mount the HGM-MZ in an area that may contain flammable liquids, vapors or aerosols. Operation of any electrical equipment in such an environment constitutes a safety hazard. WARNING: Shock hazard! Always disconnect AC power before working inside the monitor. CAUTION: Drilling holes in the HGM-MZ enclosure may damage the unit and will void the warranty. Please use the knockouts provided for electrical connections. CAUTION: The HGM-MZ contains sensitive electronic components that can be easily damaged. Do not touch nor disturb any of these components. Inspection The HGM-MZ has been thoroughly inspected and tested prior to shipment from the factory. Nevertheless, it is recommended that the monitor be re-checked prior to installation. Inspect the outside of the enclosure to make sure there are no obvious signs of shipping damage. Open the enclosure and inspect the interior of the monitor for loose components that may have become dislodged during shipment. If damage is discovered, please contact the nearest Bacharach Service Center for assistance. Locating the Monitor The HGM-MZ should be centrally located in the facility and should be easily accessible for visual monitoring and servicing. Intake sample lines can be up to 1,200 feet in length, but it is important to remember that sampling cycle time is proportional to the total number and length of individual sample lines. Dirt, grease, and oils can adversely affect the operation of the HGM-MZ. The monitor should be installed out of direct sunlight in a clean, dry area that is not subject to temperature or humidity extremes. Installation of the monitor in a mechanical room is acceptable provided reasonable environmental conditions exist. If there is a question, consider installing the unit outside of the mechanical room in a cleaner area of the facility. The location should allow the monitor to be easily accessible for visual monitoring and servicing. 10 Bacharach, Inc. Instruction 3015-5074

Mounting Instructions The HGM-MZ should be installed plumb and level and securely fastened to a rigid mounting surface. The enclosure utilizes keyhole mounting brackets designed for 1/4 inch fasteners. Locate the four screws as shown in the diagram below or by using the provided mounting template (P/N 3015-5109). Allow the screw heads to protrude approximately 1/4". HGM-MZ Mounting Specifications Hold the monitor flat against the mounting surface and allow it to slide down, engaging the screw heads in the keyhole slots of the mounting brackets. Adjust the screws as necessary to hold the monitor securely against the mounting surface. Instruction 3015-5074 Bacharach, Inc. 11

9 10 11 12 13 14 15 16 Exhaust Purge 8 7 6 5 4 3 2 1 Connecting Air Lines Overview Halogen Gas Monitor Multi Zone Individual sample lines are run from the HGM-MZ to each area of the facility to be monitored. Additionally, a purge line is installed to provide clean air for resetting the infrared zero baseline. All air line connections, located on the left side of the enclosure, are displayed below. HGM-MZ Side View Inlet/Purge Ports (see below) Exhaust Port Tubing Considerations Use ¼" outside diameter (0.040" wall) flex tubing for all air lines (P/N 304-2743) or equivalent. The tubing should be clean and free of residual moisture or other contaminants. The tubing should be cut cleanly with a sharp knife and care should be taken not to distort the tubing end. To connect the air lines to the monitor simply push the tubing firmly onto the connector. To remove a line, depress the plastic ring on the connector with one hand while withdrawing the tube with your other hand. All tubing bends should have a radius of no less than 5" to ensure proper airflow. If kinks or obstructions occur in any of the air lines the instrument may not function properly. Connecting Purge Line A purge line is required to draw fresh air into the instrument and should not exceed 300 feet in length. It is advisable to terminate the purge line outdoors, provided the input is not exposed to rain, snow, ice, exhaust fumes, or other airborne contaminates. If an outdoor installation is impractical, the line should be run to an area inside the facility that you are certain is not contaminated with ambient refrigerant gas. If this is not possible, an optional charcoal filter assembly (P/N 3015-3125) can be used to filter refrigerant from the purge line, it may be mounted adjacent to the monitor. A line-end filter (P/N 3015-3420) should be attached to the end of the purge line when the charcoal filter is not used. Connecting Exhaust Line An exhaust line can be used when it is required to vent gas samples away from the instrument and should not exceed 300 feet in length. The exhaust line should terminate in a location that is completely isolated from the purge line termination point and other areas of the facility that will be monitored. Ideally this line should terminate outdoors in a location that is not exposed to the elements. This line does not require a line-end filter. If the exhaust line terminates outside the building, position the tubing so that no water or moisture can enter it. Connecting Sample Intake Lines The HGM-MZ is designed to accommodate up to 16 separate sample intake lines. The standard configuration of the unit includes one manifold of 4 intake connectors and 1 purge connector. Additional manifolds can be easily installed to increase monitoring capacity (field installation kit P/N 3015-5171, and 4 zone line end filter kit P/N 3015-3411). 12 Bacharach, Inc. Instruction 3015-5074

Sample intake lines can be up to 1,200 feet when no exhaust tubing is used. Otherwise, the combined length of the sample line and the exhaust line cannot exceed 1,200ft.. All line terminations should be positioned to reduce the possibility of mists, aerosols, oil, water, dust, or other contaminates being drawn into the instrument. A line-end filter (P/N 3015-3420) should be attached to the end of each sample intake line. Lineend filters should be placed 12" to 18" above the floor. IMPORTANT: DO NOT block any of the zones. Unused zones may be disabled by setting their length parameter to zero feet in the zone setup screen. Please refer to the earlier section Suggested Location of Sampling Points to learn more about where to place the ends of the sample intake lines. Instruction 3015-5074 Bacharach, Inc. 13

Interior Schematic IR Bench Gas In Universal Power Supply AC Input Ground Stud IR Bench Gas Out Intake Manifold Solenoid Connectors AC Input Terminals Intake Manifold Solenoids Microcontroller Board Hydrophobic Filter Dual 4-20 ma Outputs (Signal Out Only) Gas Sample Pump Main Board -Optional- *NOTE: The plastic cable ties surrounding the air pump are to ensure safe handling during shipping. Please remove before operation. Reinstall a plastic cable around the air pump if the unit is shipped to Bacharach, Inc. for service or repair. This prevents damage during shipping. 14 Bacharach, Inc. Instruction 3015-5074

AC Power / RS-485 / Relay Connector / 4-20 madc Current Loop AC Input Terminals Relay Connector Alarm 1, 2, 3, Fault RS-485 Connector 4-20 ma (Output only DO NOT APPLY POWER) Switches / Fuses Line Fuses 1 Amp, 250 V Factory Default CPU Reset Instruction 3015-5074 Bacharach, Inc. 15

Electrical Wiring Halogen Gas Monitor Multi Zone The HGM-MZ uses a universal power supply that is capable of accepting inputs of 100 to 240 VAC, 50/60 Hz. The monitor s power consumption is 20 Watts. It is highly recommended that the monitor be connected directly to the AC power source, preferably on its own circuit. The AC power connection should be completed with UL approved 3-conductor wire (minimum 16 AWG), rated 300 VAC at 105 C. Locate a convenient service knockout and install electrical conduit in the typical manner. Locate the AC Input Terminals and Ground Stud on the inside of the monitor. Secure the incoming AC power neutral (white/blue) and live (black/brown) wires to the LINE 1 and LINE 2 terminals. Using the supplied crimp-on ring terminals, washers, and nuts, connect the incoming AC power ground wire (green) to the monitor s AC Input Ground Stud, and then install a separate wire between the ground stud and the GND terminal. Warnings & Cautions WARNING: Electrical installation should be performed by a certified electrician, and must comply with all applicable NEC/CEC and local electrical safety codes. WARNING: Copper conductors for connection to supply mains must be made in accordance with NEC/CEC and local codes. WARNING: The AC power ground wire must first be connected to the monitor s ground stud. Under no circumstances should this monitor be operated without a protective ground. Doing so poses a potential shock hazard, and is also a violation of electrical safety standards applicable to this type of equipment. CAUTION: Drilling holes in the HGM-MZ enclosure may damage the unit and will void the warranty. Please use the knockouts provided for electrical connections. A switch or circuit breaker rated 1.0 A, 250 VAC must be attached to the monitor s AC power leads. This switch must also be located in close proximity to the monitor, and be in easy reach of the operator. This switch should also be clearly marked as the monitor s main AC disconnect device. The circuit breaker or switch must disconnect all current-carrying conductors (i.e. Live and Neutral). HGM-MZ AC Input Power and Ground Connections 16 Bacharach, Inc. Instruction 3015-5074

Connecting Communication Devices Remote Display Module (HGM-RD) Connection The HGM-MZ is connected to the HGM-RD using a shielded twisted pair instrument cable. The maximum distance between the farthest away HGM-MZ and HGM-RD is 4500 feet. Use any of the remaining service knockouts to gain access to the interior of the monitor. The RS-485 communication wiring between the HGM-MZ and HGM-RD must be connected in the following manner: Locate the RS-485 connector in the HGM-MZ (page 15). Connect one lead of a twisted shielded pair to the B connection point (the far right point), note the wire color. Connect the second wire to the A connection point (the middle), note the wire color. Connect the ground to the connection point Locate the RS-485 connector marked TO MONITORS in the HGM-RD (See this topic in the HGM-RD manual 3015-5157). This connector is located on the bottom of the HGM-RD PC board, second from the right. Make the wire run to the HGM-RD and connect the twisted shielded pair to the RS-485 TO MONITORS connector using the same color code as used on the HGM-MZ. Integrating with Building Management Systems The HGM-MZ may be connected directly to a Building Management System using a shielded twisted pair cable. The cable from the Building Management System is connected to the RS-485 connector inside the HGM-MZ. MODBUS RTU is the standard communication protocol. Use any of the remaining service knockouts to gain access to the interior of the monitor. Locate the RS-485 connector and remove it from the circuit board. Secure the wire leads to the connector orienting them as shown in the diagram below. Check to make sure that the polarity matches the wiring to the Building Management System. When you are through securing the connections, carefully plug the connector back onto the circuit board. Larger Integrated Systems You may also connect the HGM-MZ to a Building Management System through an HGM-RD. In this case, first connect the HGM-MZ to the HGM-RD as described above. Then, follow the instructions in the Communications Connections section of the HGM-RD manual (3015-5157) for information on how to connect the HGM-RD to a Building Management System. RS-485 Connector Instruction 3015-5074 Bacharach, Inc. 17

Changing Terminator Switch Settings The terminator switch is shipped from the factory in the terminated or IN position. This is the correct setting if the HGM-MZ is connected as a single device, or if it is the last device on the network chain. If the HGM-MZ is to be installed in the middle of a network, the terminator must be moved to the OUT position. Locate the switch and determine its position. If it must be moved, slide the switch to the appropriate position. RS-485 Terminator Switch OUT IN 0 4 Personal Computer (Refer to HGM-MZ PC Software Section) The HGM-MZ may be connected to a personal computer using the RS-232 interface on the left side of the enclosure. Software will be provided upon request or as a download from: http://www.bacharach-inc.com/downloads.htm 18 Bacharach, Inc. Instruction 3015-5074

Multiple HGMs TERMINATOR IN HGM-RD RS-485 Halogen Gas Monitor Multi Zone Multiple HGM-MZs With HGM-RD NOTE 1: The last HGM-MZ or HGM-RD on either end of the network must have its terminator in the IN position, and all other units must have their terminators in the OUT position. NOTE 2: The total length of the RS-485 cable cannot exceed 4500 feet. (Use instrument cable 20 gage multi-strand shielded and twisted pair similar or equal to Belden cable #8762.) RS-485 Connections Between HGM-MZs NOTE: The terminators in the HGM-RD and HGM-MZ Unit 4 must be in the IN position. The terminators in HGM-MZ units 1, 2 and 3 must be in the OUT position. HGM-MZ UNIT 1 NODE 1 HGM-MZ UNIT 2 NODE 2 HGM-MZ UNIT 3 NODE 3 HGM-MZ UNIT 4 NODE 4 TERMINATOR TERMINATOR TERMINATOR TERMINATOR OUT OUT OUT IN Connecting to a Building Management System The HGM-MZ may be connected to a Building Management System via the RS-485 connector. The node address on each HGM-MZ may be set from 1 to 15 in order to identify itself to the Building Management System. Note that Building Management Systems set to a 0 or 1 address both respond to messages from the HGM-RD as address 1 therefore you should not have a unit set to 0 and another set to 1 on the same network. If the HGM-MZ network is connected directly to a Building Management System it may not be connected to the HGM-RD. However, the HGM-RD has two communication ports, an upstream port (labeled BMS) and a downstream port (labeled TO MONITORS). A BMS node may be connected to the up stream HGM-RD port while the downstream HGM-RD port talks to the HGM-MZs. In this case, the BMS is talking through the HGM-RD to the HGM-MZs, but not physically on the HGM-MZ/HGM-RD network. NOTE: If the HGM-MZ is not at the end of the line in a series connection, then the terminator on the HGM must be set to OUT. Also, each end of the series must have the terminator set to IN. Multiple HGM-MZs Connected to a Building Management System TERMINATOR OUT BMS HGM-MZ NODE 1 HGM-MZ NODE 2 HGM-MZ NODE 3 HGM-MZ NODE 4 TERMINATOR TERMINATOR TERMINATOR TERMINATOR IN OUT OUT IN Instruction 3015-5074 Bacharach, Inc. 19

Multiple HGM-MZs Connected to a Building Management System Daisy Chain Fashion RS-485 BUILDING MANAGEMENT SYSTEM TERMINATOR IN HGM-MZ UNIT 1 NODE 1 HGM-MZ UNIT 2 NODE 2 HGM-MZ UNIT 3 NODE 3 HGM-MZ UNIT 4 NODE 4 TERMINATOR TERMINATOR TERMINATOR TERMINATOR OUT OUT OUT IN PC Software NOTE 1: The HGM-MZ is compatible with HGM300 PC software version 1.52 and higher. NOTE 2: The PC software uses COM1 by default. Therefore, the interface cable should be connected to the port configured as COM1 on the PC. Also, no other software drivers or devices in the PC may control COM1 when the HGM-MZ software is in use. The connection is made through a standard straight through serial port connection. A three-wire connection is used (RXD, TXD, and GND). No hardware flow control is used. The HGM-MZ software automatically configures COM1 to match the HGM-MZ RS-232 communications parameters. NOTE 3: Occasionally the laptop connection will not connect properly and only two beeps are heard and the program times out. To resolve this, disconnect the RS-232 cable and cycle power on the HGM-MZ and the laptop. After both are operational, connect the RS-232 cable and start the software program. 1. Turn on power to HGM-MZ and allow it to warm up. 2. Connect RS-232 interface cable to PC and RS-232 port on the HGM-MZ. 3. Insert software disk into PC. 4. Open the HGM-MZ software using Windows Explorer. 5. Upon start up, the program will immediately attempt to download data from the HGM-MZ. Several beeps can be heard as the program communicates with the HGM-MZ. NOTE: To move through the screen use the ARROW keys to move up, down, left and right. 6. Use the ENTER key to select options and the ESC key to back out of a selection. 7. Using the arrow keys go to EDIT; press ENTER the EDIT Menu DROPS DOWN; select SYSTEM and then press ENTER the HGM LOCATION becomes highlighted. Press ENTER to move to the HGM TAG area; use the BACKSPACE key to remove the existing tag; then enter in a new tag. Press ENTER to return to LOCATION. Use the ARROW key to select the next item to be addressed. Note that you cannot change the SN or FIRMWARE items. Press the ESC key to return to the menu bar. 8. Go to EDIT; press ENTER; select ZONES; and then press ENTER. You may now select a specific zone to identify and set parameters. When REFRIGERANT is selected use the ARROW keys to move up and down through the gas library to locate the gas type for that zone. Highlight the gas type and press ENTER. 20 Bacharach, Inc. Instruction 3015-5074

9. To set the ALARMS first select EVAC LEVEL; press ENTER; use the BACKSPACE key to clear previous setting; and type in the new PPM level. Use the same method to set the SPILL LEVEL and LEAK LEVEL. 10. To close or bypass a zone, set the DISTANCE to 0 feet. IMPORTANT: Any time you modify a parameter (zone, system or calibration) and send it to the HGM-MZ, please wait for the PC software to indicate that the download is complete before continuing with any edits. Saving the HGM-MZ Program to a Disk or Drive Go to FILE, PATH, and change the drive letter to the drive where the program is to be saved. Give the program a name, such as A:\HGM-MZ or C:\MY DOCUMENTS\HGM-MZ; press ENTER; go to SAVE SETUP and press ENTER again. Type in the file name, such as CHRM1 (eight characters maximum without a filename extension) and then press ENTER. The program will automatically add.cfg to the filename that you typed. To Open a Saved Program Open software; go to FILE, PATH, and clear the old path and type in the proper drive for the saved program (A: or C: etc.). Press ENTER; select the proper program; press ENTER again. The saved program will be downloaded into the software. To Send a Saved Program to an HGM-MZ Open the HGM-MZ PC software; open the proper saved program; connect the PC to the HGM-MZ; and then go to HGM, SEND SETUP and press ENTER. The saved program will be sent to the HGM-MZ. Trend Data Creating a trend data file must be done while connected to the HGM-MZ. Go to FILE, PATH, clear the old path and type in the proper drive where the trend data will be saved. Press ESC; go to HGM; select GET TREND DATA; select the zone that you want to trend and press ENTER. The trend data will appear in a list format. Press ENTER again a file name screen will appear. Type in the file name for that zone (trend1 etc.). Press ENTER and the file is saved as a text file. The text file can be converted to a Microsoft Excel file or printed as is. NOTE: The TREND file must be saved ZONE by ZONE, with a filename per zone. The file will be saved in a notepad format, which can be converted to a delimited Excel file. To Convert the TREND Text File to a Microsoft Excel File Open Microsoft Excel; open the desired file using All files (*.*); select DELIMITED format and SPACE as the delimiter. Select GENERAL as the column data format. The text file now appears as an Excel file. To save the file, go to FILE, SAVE AS; select the proper drive; then change the file name extension to.xls and save it. Comments or notes may be added to this file as needed and saved. To Save and Print the HGM-MZ Software Screen, Alarm Log, Fault Log, or Diagnostic Screen Open the software while connected to the HGM-MZ. After the software gets the program, open the desired screen. With that screen as the active screen, press the ALT and PRINT SCREEN keys on the PC keyboard. Open Microsoft Word; go to FILE, NEW; go to EDIT; then PASTE. The active screen is then brought into Word. To save the file, select SAVE AS; select the proper drive and file name; and then press SAVE. Instruction 3015-5074 Bacharach, Inc. 21

USB Type Laptops Some laptops have USB ports and no RS-232 9-pin ports. You will be required to purchase a PCMCIA card that provides an RS-232 output. We recommend the PCMCIA card manufactured by: SEALEVEL SYSTEMS, INC. 155 TECHNOLOGY PLACE P. O. BOX 830 LIBERTY, SC 29657 PHONE 864-843-4343 www.sealevel.com Part number: PC- SIO-232 PCMCIA CARD A straight through RS-232 cable and a DB25 to DB9 adapter will be required to connect the laptop to the HGM-MZ. 22 Bacharach, Inc. Instruction 3015-5074

Current Loop Interfaces Optional 4 20 madc Outputs Halogen Gas Monitor Multi Zone Upon installation of the optional 4 20 madc Interface Board (page 15) (P/N 3015-5152), the HGM-MZ has the capability of providing dual 4-20 madc scrolling current loop outputs for connection to external monitoring devices. Loop outputs are powered internally. Do not use an external power supply as this can damage the loop card. The interfaces are set up as follows: Loop 1 indicates zone area Loop 2 indicates PPM Connection The external devices are connected to the HGM-MZ using a shielded dual twisted pair cable. Use any of the remaining service knockouts to gain access to the interior of the monitor. Locate the Dual 4 20 madc Output connector (page 15) and remove it from the circuit board. Secure the wire leads to the connector orienting them as shown in the diagram below. Check to make sure the polarity matches the wiring at the external device. When you are through securing the connections, carefully plug the connector back onto the circuit board. NOTE: When one or both current loop outputs are not used, install a jumper wire between the ground and the unused loop terminal(s) to prevent the system from generating a current loop fault. CAUTION: The loop outputs have isolated grounds. Therefore the cable shield should be terminated at the receiver and not the HGM-MZ. The signal for both current loops must be returned to the HGM-MZ. Current Loop Connector NOTE: SIGNAL OUT ONLY DO NOT APPLY POWER LOOP 1 ZONE LOOP 2 PPM GROUND NOTE: The ground connections are common. LOOP 1 = ZONE LOOP 2 = PPM 5 madc = Zone 1 Default 6 madc Zone 2 0.016 madc = 1 PPM --- Scalable via Software --- 4 madc = 0 PPM 20 madc = Zone 16 20 madc = 1000 PPM Instruction 3015-5074 Bacharach, Inc. 23

Connecting External Alarms Overview Each HGM-MZ includes 4, Form C, SPDT relays. The contacts are rated.5a at 250 VAC. These relays are used for the connection of external alarm devices. The relays are factory assigned to the following conditions: Relay #1 Leak Relay #2 Spill Relay #3 Evacuate Relay #4 Fault Connection Use the AC conduit or any of the remaining service knockouts to gain cable access to the interior of the monitor. Locate the relay connector (page 14) and remove it from the circuit board. Secure the leads to the connector orienting them as shown in the diagram below. When you are through securing the connections, carefully plug the connector back onto the circuit board. HGM-MZ Relay Connector NOTE: Each relay may be connected as normally open (NO), or normally closed (NC). The relay contacts are rated.5 A at 250 VAC. Latching / Non-Latching refer to Page 27 to select Alarm Ack Mode. Alarm power source power for the alarm devices connected to the relay contacts may be supplied from the AC Power Input Connector (Page 14). 24 Bacharach, Inc. Instruction 3015-5074

Typical HGM-MZ Relay 1 and Relay 2 Wiring Red Yellow Leak / Spill / Evacuate / Fault RELAY NO COMMON NC Normal configuration: Strobe = Leak Horn = Spill HORN STROBE External Power: AC < 250V DC < 15W LINE NEUTRAL MAIN INPUT Note: The device does not power accessories; power must come from an external source. Jumper the Neutral of the input power connector to the Common on the relay block. Connect one end of strobe or horn to the NO of whichever level of alarm is appropriate for application. The other end of strobe or horn is connected to the Line of the input power connector (5 A maximum). Instruction 3015-5074 Bacharach, Inc. 25

3 Setup Programming Display Screens Initial Power Up When the HGM-MZ is powered up, all front level panel LEDs will illuminate and a splash screen will appear, displaying the monitor s firmware version level. After a moment, the Warm Up screen will be displayed and the green MONITOR ON light will blink. After a 15 minute warm up cycle, the MONITOR ON light will glow steadily and the Data Display screen will be displayed. (See Appendix C for an overview map of the screens in the system.) Data Display Screen Navigating to the 1 st Setup Screen Use the UP/DOWN arrow keys to select the first text box to access the Setup screen. Press ENTER to select. HGM System Setup Screen #1 26 Bacharach, Inc. Instruction 3015-5074

Navigating to the 2 nd Setup Screen Halogen Gas Monitor Multi Zone From HGM System Setup Screen #1, select the SYSTEM option to go to HGM System Setup Screen #2. Select the ESC key to return to the System Setup Screen #1. HGM System Setup Screen #2 Location This is the name you assign to the HGM-MZ to identify its location. It may have up to 12 alphanumeric characters. 1. Press the ENTER key to adjust the setting. 2. Use the LEFT/RIGHT cursor keys to move across the entry field and the UP/DOWN cursor keys to modify the individual characters. 3. Press ENTER to accept the new entry or ESC to revert to the previous setting. Number of Zones Installed IMPORTANT: Do not change the number of zones to deactivate unused zones. Changing the number of installed zones is only necessary when manifold blocks are added or removed. Go to the individual zone that you wish to disable and set its distance to zero. 1. Press the ENTER key to adjust the number. 2. Use the UP/DOWN cursor keys to modify the number. 3. Press ENTER to accept the new number or ESC to revert to the previous setting. Alarm Ack Mode This function programs the relays in the HGM unit for latching or non-latching operation. 1. Press the ENTER key to adjust the setting. 2. Use the UP/DOWN cursor keys to toggle between settings. AUTO Non-latching (Alarm relay will automatically de-energize when the gas level drops below its alarm point.) MANUAL Latching (Alarm relay remains energized, and will not release until the alarm condition has been manually acknowledged. Refer to Acknowledging Alarms on Page 35.) 3. Press ENTER to accept the new entry or ESC to revert to the previous setting. Audible Alarm This parameter selects the function of the HGM-MZs internal audible alarm device. 1. Press the ENTER key to adjust the setting. 2. Use the UP/DOWN cursor keys to select unused, monitor on, evacuate, spill, leak, fault, or alarm. 3. Press ENTER to accept the new entry or ESC to revert to the previous setting. Instruction 3015-5074 Bacharach, Inc. 27

Zone Hold Mode Halogen Gas Monitor Multi Zone A zone can be placed on hold and continuously monitored for a length of time determined by the Zone Hold Time value. To place a zone on hold, select the zone at the top level screen, then press and hold down the ENTER key until the unit beeps. The word HOLDING will appear in the status box. While in the hold mode, further investigation of the zone s status can be made by navigating to that Zone s Setup Screen #1. To release the zone from the hold mode, press and hold down the ENTER key until the unit beeps and the screen display returns to normal. Zone Hold Time Sets the length of time a zone will be monitored when the zone hold feature is activated. The default is 15 minutes. The range is 1 to 999 minutes. 1. Press the ENTER key to adjust this setting. 2. Use the LEFT/RIGHT cursor keys to move across the entry field and the UP/DOWN cursor keys to modify the individual numbers. 3. Press ENTER to accept the new entry or ESC to revert to the previous setting. Detection Limit This is essentially a squelch setting that instructs the instrument to interpret PPM readings below the designated level as 0. The range is 1 to 99 PPM. 1. Press the ENTER key to adjust the setting. 2. Use the UP/DOWN cursor keys to modify the setting. 3. Press ENTER to accept the new entry or ESC to revert to the previous setting. Loop2 Factor This sets the PPM scale factor for current loop number 2. To calculate the current output, multiply the scale factor by the PPM and add 4. For example, at the default scale factor of 0.016, a measurement of 100ppm would generate a current output of 5.6 madc. The current output cannot exceed the 20 madc capacity of the interface. 1. Press the ENTER key to adjust the setting. 2. Use the LEFT/RIGHT cursor keys to move across the entry field and the UP/DOWN cursor keys to modify the individual characters. 3. Press ENTER to accept the new entry or ESC to revert to the previous setting. Re-Zero Mode This parameter defines the frequency at which the instrument re-zeros the optical sensor. 1. Press the ENTER key to adjust the setting. 2. Use the UP/DOWN cursor keys to toggle between settings. AUTO Sets the instrument to re-zero every 10 minutes. ZONE CHANGE Sets the instrument to re-zero at each zone change. This is the most accurate setting, but increases the time interval between measurement cycles. 3. Press ENTER to accept the new entry or ESC to revert to the previous setting. 28 Bacharach, Inc. Instruction 3015-5074

Navigating to the 3 rd Setup Screen Halogen Gas Monitor Multi Zone From HGM System Setup Screen #2, select the MORE option to go to HGM System Setup Screen #3. Select the BACK option to return to HGM System Setup Screen #2. HGM System Setup Screen #3 Service Timeout Sets the length of time the Service Mode is in effect. Stops the monitor for up to 300 minutes (5 hrs) to allow for servicing the unit. 1. Press the ENTER key to adjust the setting. 2. Use the LEFT/RIGHT cursor keys to move across the entry field and the UP/DOWN cursor keys to modify the individual numbers. 3. Press ENTER to accept the new entry or ESC to revert to the previous setting. Node Address Each HGM on the network must has a distinct node address. The node address may be set from 1 to 64. 1. Press the ENTER key to adjust the setting. 2. Use the LEFT/RIGHT cursor keys to move across the entry field and the UP/DOWN cursor keys to modify the individual numbers. 3. Press ENTER to accept the new entry or ESC to revert to the previous setting. Password This field is used to define a system password. The default setting is 000, which provides no password protection. 1. Press the ENTER key to adjust the password. 2. Use the LEFT/RIGHT cursor keys to move across the entry field and the UP/DOWN cursor keys to modify the individual alphanumeric characters. 3. Press ENTER to accept the new password or ESC to revert to the previous setting. Instruction 3015-5074 Bacharach, Inc. 29