maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement.

Similar documents
AllStyle Coil Company, LP 7037 Brittmore Houston, TX Phone Fax

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES - FIELD INSTALLED. K5EU090 and K4EU Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ)

INSTALLATION INSTRUCTIONS

CROWN. Boiler Co. Santa-Fe Series. Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

Your safety and the safety of others are very important.

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

INSTALLATION INSTRUCTION

IMPORTANT CB26UH CBX26UH. Service Literature. CB26UH and CBX26UH Series Table of Contents. Model Number Information... 2

INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER

DVPVC. Multi-Position, Variable-Speed Air Handler. Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV

AHG**-0B Series Hydronic Air Handling Units

ARPT Series. Multi-Position. 2 to 5 Tons. Internal TXV, Multi-Speed PSC Motor

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

Technical Guide DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS. 7-1/2 and 10 NOMINAL TONS LA090 & LA120 SUPPLY AIR PLENUMS

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

ARPT Series. Multi-Position. 1½ to 5 Tons. Internal TXV, Multi-Speed PSC Motor

ARPT Series. Multi-Position, Multi-speed Air Handler with Internal TXV and PSC Motor 2 to 5 Tons. Contents. Product Features

INSTALLATION INSTRUCTIONS

DVPEC. Multi-Position, Variable-Speed air handler. Comfortnet Compatible ECM-based Internal EEV, Inverter-tuned 2 to 5 Tons

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

B Series Multi-Position & Hydronic Air Handlers Electric or Hot Water Heat, with available Variable-Speed High Efficiency ECM Motor

BCE4 PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS WARRANTY

COMFORT PACK INSTALLATION AND MAINTENANCE INSTRUCTIONS

Installer s Guide 4FWCA, 4FWCF 18-GF01D1-2. Air Handlers Upflow / Horizontal Left or Right 2 5 Ton

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH

INSTALLATION INSTRUCTIONS

ACNF Series. Ceiling-Mount Air Handlers 1½ to 2½ Tons

AVPTC Multi-Position, Internal Txv

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

ACNF Series. Ceiling-Mounted Air Handlers 1½ to 2½ Tons

MERIT SERIES Up Flow / Horizontal

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

ASPT Series. Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV 1½ to 5 Tons. Contents. Product Features

AIR HANDLERS RBHA- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT

AVPTC Multi-Position, Internal Txv

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

ASPT Series. Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV 1½ to 5 Tons. Contents. Product Features

AVPTC. Multi-Position, Variable-Speed ECM Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents.

AVPTC Multi-Position, Internal Txv

SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H A American Standard Heating & Air Conditioning

VERTICAL MOUNT AIR HANDLERS

HIGH EFFICIENCY AIR HANDLER

AR SERIES COMMERCIAL AIR HANDLERS INSTALLATION & OPERATING INSTRUCTIONS

F, P Series Multi-Position Air Handler Electric or No Heat, with available 5-Speed High Efficiency ECM Motor

INSTALLATION & OPERATING INSTRUCTIONS FOR CEILING MOUNT AIR HANDLERS AC SERIES

Ruud Standard Efficiency Air Handler

Product Data. Features/Benefits. 40QKB024,036 40QKE024,036,048 Cooling Only and Heat Pump In-Ceiling Cassettes. 2to4NominalTons

MERIT Series R-410A - Upflow / Horizontal

MX Series Indoor Modular Blowers Electric Heat, Hot Water Heat, or No Heat

INSTALLATION MANUAL WARNING WARNING MODULAR NON-VARIABLE SPEED AIR HANDLERS MODELS: MA LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES

INSTALLATION & OPERATING INSTRUCTIONS AEM SERIES VARIABLE SPEED MULTI-POSITION ELECTRIC HEAT AIR HANDLER

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

TECHNICAL SPECIFICATIONS

Ruud Standard Efficiency Air Handler

Commercial High-Efficiency Condensing Units

MODELS B1PA024, 030 AND 036

ASUF Series. Multi-Position. Air Handler 1½ to 5 Tons

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

MERIT Series R-410A - Upflow / Horizontal

CATALOG. SKYPAK Self-Contained Heating/Cooling Units

Installation Instructions

HIGH EFFICIENCY AIR HANDLER

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS WA121

HIGH EFFICIENCY TWO-STAGE ECONET ENABLED AIR HANDLER

INSTALLATION AND MAINTENANCE INSTRUCTIONS. MCE4 Series. Electric Cooling Package Unit. Save these instructions for future reference

Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler

INSTALLATION INSTRUCTION

AIR HANDLERS AIR HANDLERS

B Series Multi-Position & Hydronic Air Handlers Electric or Hot Water Heat, with available Variable-Speed High Efficiency ECM Motor

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

TECHNICAL SPECIFICATIONS

CWA4 Chilled & Hot Water Fan Coil

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

The Premium Quality Fan Coil Units for Vertical, Horizontal (Left or Right) Application with Direct Expansion, Hydronic or Electric Heat

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

WH1T SERIES Constant Torque Motor (ECM) Efficiencies up to 14 SEER. FORM NO. H REV. 1 Supersedes Form No. G Rev. 3

GREEN REFRIGERANT R-410A

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Rheem High Efficiency Modulating EcoNet Enabled Air Handler

Bosch BVA Series Air Handler

Installation Instructions

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N

Rheem Air Handlers. RHML- Series X-13 (ECM) Motor

RHGN-H: COMMERCIAL AIR HANDLER WITH VARIABLE FREQUENCY DRIVE (VFD) NOMINAL 10 TONS R-410A REFRIGERANT 2-STAGE AIR-FLOW

INSTALLATION MANUAL SINGLE PIECE, 4 POSITION AIR HANDLERS MODELS: AHR SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

INSTALLATION INSTRUCTIONS HIGH EFFICIENCY PACKAGED AIR CONDITIONER

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

TECHNICAL GUIDE DESCRIPTION EA090/FA090 SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNIT INDOOR UNIT

CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH

SPLIT SYSTEM COOLING 1½ 5 TON ALLEGIANCE 14 MODELS 4A7A C/30-060B American Standard Heating & Air Conditioning

Installation Instructions

Transcription:

AHF / AHK SERIES AIR HANDLING UNITS INSTALLATION GUIDE GENERAL The AHF / AHK series is designed for horizontal recessed installations in a furred down area, above a suspended ceiling or recessed in the ceiling. AHF / AHK models are for electric heat, DX cooling, and for heat pump applications. The unit can be configured for return air flow through the integral access panel or at the end of the unit. Installation tabs are built into the cabinet to facilitate mounting the unit. Optional panels are available that allow a wide range of installation options. Electric resistance heaters are available along with optional air conditioning and heat pump indoor coils. Full service of all components is easily accomplished through the access panel. WARNING: Due to possible damage to equipment or personal injury, installation, service and maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement. Installation of this unit shall be made in accordance with the National Electric Code, NFPA No. 90A and 90B, and any other local codes or utilities requirements. WARNING: HAZARDOUS VOLTAGE Ensure all power is disconnected before installing or servicing this unit. More than one disconnect device may be required to de-energize the equipment. Hazardous voltage can cause severe personal injury. Make certain all panels are in place before operating this unit. UNPACKING Carefully unpack the unit and inspect the contents for damage. If any damage is found at the time of delivery, proper notification and claims should be made with the carrier who delivered the unit. Check the rating plate to assure model number and voltage, plus any kits agree with what you ordered. The manufacturer should be notified within 5 days of any discrepancy or parts shortage. LOCATION The blower coil unit should be centrally located and may be installed above a suspended ceiling with integral return panel, in a furred down area with remote or integral return, or recessed in the ceiling. This unit is approved for 0 clearance from any side, front, rear or duct work. The unit must be installed in a level position to ensure proper condensation drainage. Make sure the unit is level in both directions within 1/8. The unit incorporates installation tabs that mount to the framing and provide a ½ inch flange to trim to the finished edge of a sheetrock ceiling. The access panel mounts to the cabinet and trims the installation. LM20020

All service entrances and exits on the cabinet are recessed to allow for 2 x 4 framing of the opening the cabinet will be centrally located within. Any modifications to existing framing should be accomplished by the general contractor to ensure structural strength is maintained in the structure. The structural opening in the framing for the AHK series should be 51 ¼ long and 23 ¼ wide. The structural opening in the framing for the AHF series should be 47 ¼ long and 23 ¼ wide. The unit should be positioned where the bottom edge of the cabinet is ½ below the framing member. DUCT WORK The duct work should be installed in accordance with the NFPA No. 90A Installation of Air Conditioning and Ventilating systems and No. 90B Residential Type Warm Air Heating and Air Conditioning Installation. The duct work should be insulated in accordance with the applicable requirements for the particular type installation as required by HUD, FHA, VA the applicable building code, local utility or other governing body. CONDENSATE DRAIN The AHF / AHK / and AHL series furred down air handlers are now shipped standard with our integral drain trap built into the drain pan. This unique design eliminates the need for exterior condensate traps in the primary drain line. Do not reduce the drain line size less than the connection size on the drain pan. Condensate should be piped to an open drain or to the outside. All drains must pitch downward away from the unit a minimum of 1/8 per foot of line to ensure proper drainage. REFRIGERANT PIPING Refrigerant pipe connections are located within the unit cabinet. Holes are provided to route refrigerant pipes from either side of the cabinet. Refrigerant piping external to the unit shall be sized in accordance with the instructions of the manufacturer of the outdoor equipment. When units are recessed mounted in the wall, make certain that piping connections are pressure tested prior to the wall being closed. Manufacturer dose not insulate the expansion valve distributor tubes or liquid lines coming from manifold. It is the sole responsibility of the contractor to properly insolate from condensation. (YOU MUST INSULATE THE REFRIGERANT LINES AND TXV UP TO WERE THE PAN CATCHES ALL CONDENSATE DRIPS.) METERING DEVICE All units are shipped with a check-flow piston installed which is designed for air conditioning or heat pump operation. If your application requires a thermal expansion valve or check expansion valve then it is necessary to remove the piston from the distributor assembly and install the proper metering device. Be sure to follow the instructions in the kit to ensure proper installation. WIRING Consult all schematic and pictorial wiring diagrams of this unit and the outdoor equipment to determine compatibility of the wiring connections and to determine specific requirements. All field wiring to the blower coil should be installed in accordance with the latest edition of the National Electric Code NFPA No. 70 and any local codes. Check rating plates on unit for rated volts, minimum circuit ampacity and maximum over current protection. Supply circuit power wiring must be 75 degree C. (167 degree F) minimum copper conductors only. Copper supply wires shall be sized to the National Electric Code or local code requirements, whichever is more stringent. The unit is shipped wired for 230/240 Volt AC 60 HZ 1 Phase Operation. If the unit is to be operated at 208 VAC 60HZ, then follow the instructions on the indoor unit wiring diagram to change the low voltage transformer to 208 VAC operation. Be sure the unit is properly grounded. Class 2 low voltage control wiring should not be run in conduit with power wiring and must be separated from power wiring, unless class 1 wire of proper voltage rating is used. Low voltage control wiring should be 18 awg, color coded (105 degree C minimum). For lengths longer than 100ft., 16 awg wire should be used. Make certain that separation of control wiring and power wiring has been maintained. THERMOSTAT Select a thermostat that is commonly referred to as a single stage cooling with electric heat subbase. This stat will energize the fan on a demand for heat or cool. Install the thermostat on an inside wall, away from drafts, lights or other heat sources in a location that has good air circulation from the other rooms being controlled by the thermostat. The thermostat should be mounted 4 to 5 feet above the floor. AHF / AHK Series AHU Installation Guide Page 2

INSTALLATION GUIDE SEQUENCE OF OPERATION Cooling (cooling only or heat pump with reversing valve energized in heat mode). When the thermostat calls for cooling, the blower relay is energized. The N.O. contacts will close, after a time delay, the indoor blower will operate. The circuit between R and Y is completed: causing the contactor on the outdoor equipment to close and start the compressor and the outdoor fan motor. Cooling (heat pump with reversing valve energized in cooling mode). When the thermostat calls for cooling the circuit between R and G and R and O is completed. Circuit R and O energizes the reversing valve to the cooling position. Circuit R and G energizes blower relay. The N.O. contacts will close, after a time delay, the indoor blower will operate. The circuit between R and Y is completed: causing the contactor on the outdoor equipment to close and start the compressor and the outdoor fan motor. Heating (electric heat only). When the thermostat calls for heat, the circuit between R and W is completed, the heat sequencer is energized. A time delay will occur: Then the heating element(s) and the indoor blower motor will come on. Heating (heat pump reversing valve energized in heat mode). When the thermostat calls for heat, the circuits between R and B, R and Y and R and G are completed. Circuit R and B energize the reversing valve switching it to the heat position. Circuit R and Y energized the outdoor unit contactor starting the compressor and outdoor fan. Circuit R and G energizes the blower relay starting the blower motor. If the indoor room temperature should continue to fall, circuit R and W2 is by the second-stage heat bulb on the thermostat. Circuit R-W2 energizes the heat sequencer. The completed circuit will energize the supplemental electric heat. Blower Time Delay. This unit is equipped with timed on and off relay. This relay delays the start and stopping of the indoor fan motor to maximize efficiency of the unit. Defrost. Supplemental heat during defrost can be provided by connecting B on the blower coil to the defrost relay on the heat pump. This will complete the circuit between R and B (in the blower coil) through a set of contacts in the defrost relay in the outdoor unit when the unit starts the defrost cycle. This circuit, when it is connected, will help prevent cold air from being discharged from the indoor unit during the defrost cycle. BLOWER Units through three tons are supplied with a multi-speed (high, medium & low) motor with direct drive blower wheel which can obtain various air flows. One and one half ton units are factory wired on low speed, two ton units are factory wired on medium speed and two and one half ton units are factory wired on high speed. If a different motor speed is required, disconnect all power to the unit, remove the factory wired indoor fan motor lead from the fan relay and place an insulated cap on the removed motor lead. Remove the insulated cap from the desired indoor fan motor lead, place a spade connector on the lead and connect it to the fan relay where the original lead was connected. The black motor lead is high speed, the red motor lead is low speed, and the blue motor lead (if available) is medium speed. Be sure to check the air flow and temperature drop across the evaporator coil to ensure that you have sufficient airflow. START UP Once all connections are completed, the unit should be started up and a check out of the completed system should be performed. Before performing any system test, make sure that all grilles, registers and dampers are open and set to the correct position. Also make certain that an air filter is installed in the return air prior to running the air handler. A performance test should be completed in accordance with the outdoor equipment manufacturer s instructions. Airflow tests should be conducted in the heating and cooling modes to ensure satisfactory operation. MAINTENANCE The system air filter(s) should be inspected, cleaned or replaced at least monthly. If the filter is mounted internal to the unit, make sure that electrical power is disconnected before removing the access panels. Make certain that the access panels are replaced and secured properly before placing the unit back in operation. This product is designed for dependable service; however, periodic maintenance should be scheduled to be conducted by trained professional service personnel. This service should be conducted at least annually, and should include testing and inspection of electrical and refrigerant components. The heat transfer surface should be cleaned. The blower motor is permanently lubricated for normal operating conditions. AHF / AHK Series AHU Installation Guide Page 3

WIRING DIAGRAM DISCONNECT POWER BEFORE INSTALLATION OR SERVICING. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH. White THERMOSTAT W G R C Green Red Purple Air Handler with 10kW Heating Elements or less ALLSTYLE COIL COMPANY, LP 7037 BRITTMOORE RD. HOUSTON, TX 77041 (713) 466-6333 AW1201-55318 Brown White ELEMENT HEAT RELAY ELEMENT M2 M4 M1 M3 Orange SEE NOTE 1 230V 208V Com 24V TRANSFORMER Orange Purple or White CIRCUIT NO.1 208-230/60/1 L2 L1 GND USE COPPER CONNECTORS ONLY. Use Conductors Suitable for 167 Deg F. 208-230VAC / 60Hz / 1Ph EQUIPMENT GROUND USE COPPER OR ALUMINUM WIRE. COM NC NO G C R INDOOR MOTOR Green Red FAN TIMER WIRING TABLE FACTORY WIRING FIELD WIRING HIGH VOLTAGE WIRING LOW VOLTAGE WIRING NOTE 1) Wiring change is required to convert transformer to 208 Volts. Disconnect power. Disconnect orange high voltage lead and place on terminal labeled as "208V" for 208 Volts power. Red TERMINAL BLOCK/ DISCONNECT NOT ALL MODELS USE FUSE LINKS Single Speed Fan Control Connect Only One Fan Lead Not all models have 3 speeds - High Speed - Medium Speed Red - Low Speed CONSULT NATIONAL CODE FOR PROPER WIRE SIZE. Red LIMIT FUSE LINK LIMIT FUSE LINK Brown Brown/White Purple AHF / AHK Series AHU Installation Guide Page 4

NOTES WARNING: Do not store or use any corrosives or combustibles in the vicinity of this unit. All panels must be in place and properly secured before operating this equipment. All electrical power servicing this unit must be disconnected prior to removal of any panels. Service of this unit must be accomplished by qualified trained professional personnel only. NOTE: The condensate drain pan, shown in Figure 1, has an adjustment strap to ensure proper condensate removal. The strap is identified by the arrow in the figures. If it is found to be necessary, the strap may be easily loosened and refastened to change the pitch in the drain pan toward the drain outlets. The drain pan pitch should not exceed 1/2 of an inch. For proper drain line connections, follow instructions from CONDENSATE DRAIN section above. Figure 1. Drain Pan Adjustment Strap AHF / AHK Series AHU Installation Instructions Page 5

AHF / AHK SERIES FURRED DOWN AHUs PRODUCT FEATURES Designed for installation in a furred down area or dropped ceiling area. Optional DX Coil installed for Cooling only, cooling & electric heating, or heat pump with electric back up. Optional factory installed electric heat of either 3, 5, 6, 8, or 10 KW. Cooling capacities of 1, 1.5, 2.0, 2.5, or 3.0 nominal tons. Standard internal filter rack. Factory installed time delay relay. Pre-punched side mounting tabs for easier installations. Powder coated hinged access panels must be ordered separately. Full insulated embossed galvanized steel cabinets PHYSICAL DIMENSIONS (Inches) Nominal Model Cabinet Cabinet Cabinet Plenum Plenum Optional Access Access Filter Capacity Height A Length B Width C Height D Width E Return Grill Grill Size In Tons Opening Width Length 1.0,1.5, 2.0, 2.5 AHF 12" 47" 22.5" 8" 21.5" 21 X 7.5" 27.25" 51.25" 20 X 20" 2.0, 2.5, 3.0 AHK 12" 51" 22.5" 8" 21.5" 21 X 7.5" 27.25" 55.25" 20 X 20" Refrigerant Connections: Suction Lines are 3/4" and Liquid Lines are 3/8" on all models. Unit may be ordered for either rear return or for return through louvered access panel. AllStyle Coil Co., L.P.

AHF & AHK SERIES FURRED DOWN AHUs ELECTRICAL SPECIFICATIONS MODEL Electric Total MCA MOP BTUH Heat KW Amps AHF 0 1.5 2 15 0 12 3 14 18 20 10,257 5 22 27 30 16,411 6 27 34 40 20,512 8 35 44 50 27,304 10 42 52 60 32,764 AHF/K 0 1.5 2 15 0 18 3 14 18 20 10,257 & 5 22 27 30 16,411 24 6 27 34 40 20,512 8 35 44 50 27,304 10 42 52 60 32,764 AHF 0 1.5 2 15 0 & 3 14 18 20 10,257 AHK 5 22 27 30 16,411 30 6 27 34 40 20,512 8 35 44 50 27,304 10 42 52 60 32,764 AHK 0 4.0 5 15 0 36 3 14 21 30 10,257 5 22 30 40 16,411 6 27 37 40 20,512 8 35 47 50 27,304 10 42 55 60 32,764 Derate BTUH heating capacity 25% for 208 volt installations. Specifications may change without notice. BLOWER PERFORMANCE Model Speed Static Pressure 0.1 0.2 0.3 AHF 12 Low 535 460 400 Medium 700 630 540 High 800 730 620 AHF Low 740 670 610 AHK Medium 970 850 760 18 High 1020 950 840 AHF Low 740 670 610 AHK Medium 970 850 760 24 High 1020 950 840 AHF Low 740 670 610 AHK Medium 970 850 760 30 High 1020 950 840 AHK Low 1020 950 870 36 Medium 1140 1100 1040 High 1250 1200 1150 AllStyle Coil Co., L.P.

AHF / AHK / AHL SERIES FURRED DOWN AHUs NEW INTEGRAL DRAIN TRAP The AHF / AHK/ and AHL series furred down air handlers are now standard with our integral drain trap. This unique design eliminates the need for exterior condensate traps in the primary drain line. No more hassles trying to find room above a dropped ceiling for a condensate trap. This feature will save you time,.and money ACCESS PANEL OPTIONS Pick from two options, either solid for ducted return, or louvered for return directly into the air handler. Both are constructed of heavy galvanized steel with a glossy powder paint finish. The doors are hinged with the frame mounting to the wall. Access Panel Dimensional Data Model Used on Part No. Description Frame Opening Access Air Handler O.D. Dimensions Panel Models Dimensions Dimensions ACP-51S AHF RP21038 Solid 27.25 W x 23.5 W x 25.0 W x AHL18-30 Panel 51.25 L 47.5 L 49.0 L ACP-51L** AHF RP21039 Louvered 27.25 W x 23.5 W x 25.0 W x AHL18-30 Panel 51.25 L 47.5 L 49.0 L ACP-55S AHK RP21040 Solid 27.25 W x 23.5 W x 25.0 W x AHL30-36 Panel 55.25 L 51.5 L 53.0 L ACP-55L** AHK RP21041 Louvered 27.25 W x 23.5 W x 25.0 W x AHL30-36 Panel 55.25 L 51.5 L 53.0 L ** Louvered panel includes a filter rack. AllStyle Coil Co., L.P.

AllStyle Coil Company, L.P. 7037 Brittmoore Rd. Houston, TX 77041 Since the manufacturer has a policy of continuous product and product data improvement, it reserves the right to change design and specification without notice. AHF / AHK Series AHU Installation Instructions Rev. 09/2012