Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 100,000 BTUH S9V2C100U4PSBA TAG:

Similar documents
Submittal. Downflow Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080D3PSBA TAG:

Submittal. Downflow Two Stage Condensing Gas Fired Furnace 60,000 BTUH S9V2B060D3PSBA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U4-SUB-1-EN. February 2016 S9V2B080U4PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 40,000 BTUH S9V2B040U3-SUB-1-EN. February 2016 S9V2B040U3PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U3-SUB-1-EN. February 2016 S9V2B080U3PSAA TAG:

Submittal. Downflow Two Stage Condensing Gas Fired Furnace 100,000 BTUH S9V2C100D4-SUB-1-EN. March 2016 S9V2C100D4PSAA TAG:

Upflow/ Horizontal Left/Right, Downflow Two Stage Condensing Gas Fired Furnace

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

Upflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

XV80i. Upflow/Horizontal 80% 2-Stage, Variable Speed Gas-Fired Furnace with Whole House Air Cleaner PUB. NO

Downflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

Upflow/Horizontal Left, Downflow/Horizontal Right Two Stage Condensing Gas-Fired Furnace

XC80 TUD2B060ACV32A TUD2B080ACV32A TUD2C080ACV42A TUD2B100ACV32A TUD2C100ACV52A TUD2D120ACV52A TUD2D140ACV52A

Downflow/Horizontal Right Induced Draft Gas Furnace

Upflow/Downflow Horizontal Right or Left Gas-Fired Furnace

Upflow/Horizontal Condensing, Gas-Fired Furnace

Downflow/Horizontal Right or Downflow/Horizontal Left Induced Draft Gas Furnace

Upflow/Horizontal 2-Stage, Communicating Variable Speed Gas Furnace Platinum SV

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80

Upflow/ Horizontal Left, Downflow/ Horizontal Right Two Stage Condensing Gas-Fired Furnace XL 90

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XB 80 TDD-D-1 PUB. NO

Upflow/Horizontal Left Downflow/Horizontal Right Condensing, Direct Vent Gas-Fired Furnace FREEDOM 90 SINGLE STAGE

Upflow/ Horizontal Left/Right, Downflow Single and 2 Stage Non-Condensing Gas Fired Furnace

Upflow/ Downflow Horizontal Right or Left Gas-Fired Furnace

Submittal. Split System Cooling 5.0 Ton 4A7A3060D1000P TAG:

Submittal. Split System Cooling 4A7A6024J-SUB-1B-EN. January A7A6024J1000B TAG:

Product Data. Convertible Air Handlers 1 1/2 5Ton

80% and 95% furnace models feature aluminized steel heat exchangers to conduct heat quickly and increase durability.

X341119P10 Gas Furnace Var. Speed Blower Var. Speed Inducer Two Stage Heat Direct Vent Models:

Product Data. Convertible Air Handlers 1 1/2 5Ton

Variable Speed Convertible Air Handler 5 Ton

Submittal. 1 1/2 Ton Convertible Air Handler TEM3A0B18S21SA TEM3A0B18-SUB-1C-EN. July 2014 TAG:

Submittal. 2 Ton Convertible Air Handler TEM3A0B24S21SA TEM3A0B24-SUB-1C-EN. July 2014 TAG:

SERVICE FACTS WARNING M801-SF-1C. Gas Furnaces Upflow & Downflow Induced Draft 1 Stage Heat Models: DISCONNECT POWER BEFORE SERVICING M801P040AU24AA

GME8 80% AFUE. Multi-Position, TwinComfort. Heating Input: 60, ,000 BTU/h

FG7T (C and L Series)

Submittal. 5 Ton Convertible Air Handler TEM3A0C60S51SA TEM3A0C60-SUB-1C-EN. July 2014 TAG:

Variable Speed Convertible Air Handler 4 Ton

2 Ton Convertible Air Handler TAM7A0A24H21SD Standard Coil TAM7A0A24H21EA Black Epoxy Coil

*DD2B060A9V3VA *DD2B080A9V3VA *DD2C100A9V5VA *DD2D120A9V5VA

MERIT SERIES Downflow

Variable Speed Convertible Air Handler 2 1/2 Ton

TECHNICAL SPECIFICATIONS

DM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

PRODUCT SPECIFICATIONS 1 *UH2B080A942VA

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL

Cooling Capacity CFM in. w.c. (125 Pa)

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

Cooling Capacity CFM range

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

ELITE SERIES Downflow - High Efficiency Blower Motor

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

Cooling Capacity CFM in. w.c. (125 Pa)

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

ADSH8. Two-Stage Convertible. Heating Input: 40, ,000 BTU/h

Comfort, Quality and Efficiency.

RG7D 1-Stage Heat Series

13 GEP A L P - 1 A

Wt. Lbs Model Number (BTUH) Hz

TECHNICAL SPECIFICATIONS

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

GMS95 GAS $AVER PRODUCT SPECIFICATIONS 95% AFUE. Multi-Position, Single-Stage/Multi-Speed Gas Furnace. Heating Capacity: 46, ,000 BTUH

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

Cooling Capacity CFM in. w.c. (125 Pa)

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

G6RC Series TECHNICAL SPECIFICATIONS

H9MPV. 2- Stage Variable Speed 90. Flexibility. Quality. Comfort. Efficiency. Service (7/2004)

Submittal. Single Packaged Heat Pump 15 SEER Convertible 4WCY5024A-SUB-1A-EN. March WCY5024A1000A TAG:

FORM NO. G REV. 2 Supersedes Form No. G Rev. 1 GAS FURNACES

FORM NO. G REV. 4 Supersedes Form No. G Rev. 3

TSTAT0101SC Recommended. Cooling Capacity CFM in. w.c. (125 Pa)

Product Catalog Gas Heating Products: Indoor and Outdoor Units

36,000-62,000 BTUH Nominal Capacity

RGE 13 A T - 1 A

COMFORT CONTROL 90 PLUS WITH DUAL TWO-STAGE UPFLOW GAS FURNACES

TZ96MDV SERIES Model with Input Rates from 60 to 100 kbtu [17.58 to kw] (All Models 95% A.F.U.E. )

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

80% AFUE. Multi-Position, Dual$aver. Heating Input: 70, ,000 BTU/h

Ruud Achiever Plus Series Multi-position Gas Furnaces

GAS FURNACES SUPER QUIET 80 TWO STAGE 80% A.F.U.E. DOWNFLOW GAS FURNACES

MULTI POSITION GAS FURNACE

MULTI POSITION GAS FURNACE

TSTAT0201CW Recommended (sold separately)

GMS9/GCS9 SERIES 93% AFUE

TZ96MDP SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 96% A.F.U.E. )

G60UHV(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

Multi-Position Gas Furnaces

W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to kw] (92% A.F.U.E. )

GAS FURNACES SILHOUETTE II PLUS 2 LXE TWO STAGE 80% A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES

G I E TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S DESCRIPTION FEATURES WARRANTY SUMMARY

Energy Saving. Space Saving.

Series Two- Stage Multi-position Gas Furnaces. Ruud Achiever Plus. R96T- Series 96% A.F.U.E. * Input Rates from 40 to 115 kbtu [11.72 to 33.

SLP98UHV WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

Transcription:

Submittal Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 100,000 BTUH Upflow, Convertible to HorizontalRight or HorizontalLeft S9V2C100U4PSBA Note:Graphics in this document are for representation only. Actual model may differ in appearance. SAFETYWARNING TAG: Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. March 2017 S9V2C100U4-SUB-1A-EN

Outline Drawings 2 S9V2C100U4-SUB-1A-EN

Product Specification MODEL S9V2C100U4PSBA MODEL S9V2C100U4PSBA TYPE Upflow/Horizontal Type Fired 409 Stainless Steel RATINGS (a) 1st Stage Input BTUH (ICS) 65,000 1st Stage Capacity BTUH 63,050 2nd Stage Input BTUH 100,000 2nd Stage Capacity BTUH (ICS) (b) (c) 97,000 Unfired 29 4C Stainless Steel Gauge (Fired) 20 ORIFICES Main Nat. Gas Qty. Drill Size 5-45 LP Gas Qty. Drill Size 5-56 1st Stage Temp. Rise (Min.-Max.) 25-55 GAS VALVE Redundant - Two Stage 2nd Stage Temp. Rise (Min.-Max.) 35-65 AFUE (%) 96.0 BLOWER DRIVE DIRECT Diameter Width (In.) 11 X 10 No. Used 1 Speeds (No.) Variable CFM vs. in. w.g. See Fan Performance Table Motor HP 3/4 RPM Variable Volts/Ph/Hz 120 / 1 / 60 FLA 8.0 COMBUSTION FAN Type Centrifugal Drive No. Speeds Direct - 2 Motor HP RPM 3300/2600 Volts/Ph/Hz 120 / 1 / 60 FLA 0.66 FILTER Furnished? Type recommended Hi Vel. (No.-Size-Thk.) VENT PIPE DIAMETER Min (in.) (d) (e) No High Velocity 1 20x25 1 in. 2 Round PILOT SAFETY DEVICE Type BURNERS Type 120 V SiNi Igniter Multiport Inshot Number 5 POWER CONN. V/Ph/Hz (f) 120 / 1 / 60 Ampacity (In Amps) 10.8 Max. Overcurrent Protection (Amps) 15 PIPE CONN. SIZE (in.) 1/2 DIMENSIONS H x W x D Uncrated (In.) 34 x 21 x 28 3/4 Crated (In.) 35-1/2 x 23 x 30-7/8 WEIGHT Shipping (Lbs.)/Net (Lbs.) 154/144 (a) For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applications, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level. (b) Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.3 latest edition. (c) Based on U.S. government standard tests. (d) Refer to the Vent Length Table in the Installer's Guide. (e) All S9V2 furnace models have a vent outlet diameter that equals 2 in. (f) The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. HEAT EXCHANGER S9V2C100U4-SUB-1A-EN 3

Heating and Airflow Tables S9V2C100U4PSBA Table 1. S9V2C100U4PSBA Heating Airflow S9V2C100U4PSBA Furnace Heating Airflow (CFM) and Power (Watts) vs. External Static Pressure with Filter 1st Stage Capacity = 63,050 2nd Stage Capacity = 97,000 Heating Airflow Setting Target Airflow External Static Pressure 0.1 0.3 0.5 0.7 0.9 CFM 1191 1199 1208 1216 1224 Low 1146 Temp. Rise 50 49 49 49 49 Watts 133 192 251 310 369 CFM 1314 1304 1294 1284 1274 Medium Low 1280 Temp. Rise 45 45 45 46 46 Heating 1st Stage Watts 173 235 297 359 421 CFM 1478 1466 1453 1441 1428 Medium (a) 1446 Temp. Rise 40 40 40 40 40 Watts 243 304 364 425 485 CFM 1498 1511 1524 1537 1550 High 1493 Temp. Rise 39 39 39 39 38 Watts 264 330 397 464 531 CFM 1480 1488 1496 1503 1511 Low 1450 Temp. Rise 60 60 60 60 60 Watts 244 312 380 449 517 CFM 1658 1656 1654 1652 1650 Medium Low 1620 Temp. Rise 54 54 54 54 55 Heating 2nd Stage Watts 330 408 486 564 642 CFM 1869 1857 1846 1811 1714 Medium (a) 1830 Temp. Rise 48 48 49 49 52 Watts 471 549 628 677 695 CFM 1959 1919 1879 1811 1714 High 1890 Temp. Rise 46 47 48 49 52 Watts 540 600 660 677 695 (a) Factory Setting. 4 S9V2C100U4-SUB-1A-EN

Heating and Airflow Tables S9V2C100U4PSBA /S9V2C100D4PSBA Table 2. S9V2C100U4PSBA/ S9V2C100D4PSBA Airflow S9V2C100U4PSBA / S9V2C100D4PSBA Furnace Airflow (CFM) and Power (Watts) vs. External Static Pressure with Filter Unit Outdoor Airflow Setting (CFM/ ton) External Static Pressure 0.1 0.3 0.5 0.7 0.9 450 CFM 1125 1125 1125 1125 1125 Watts 123 178 236 296 360 420 CFM 1050 1050 1050 1050 1050 Watts 104 156 210 268 329 400 CFM 1000 1000 1000 1000 1000 Watts 93 142 195 251 309 2.5 Ton 370 350 CFM 925 925 925 925 925 Watts 77 123 173 226 282 CFM 875 875 875 875 875 Watts 68 112 160 211 265 330 CFM 825 825 825 825 825 Watts 60 102 147 196 249 310 CFM 775 775 775 775 775 Watts 52 92 135 183 234 290 CFM 725 725 725 725 725 Watts 45 83 125 170 220 450 CFM 1350 1350 1350 1350 1350 Watts 194 259 326 396 468 420 CFM 1260 1260 1260 1260 1260 Watts 163 224 287 353 422 400 CFM 1200 1200 1200 1200 1200 Watts 144 202 263 327 393 3.0 Ton 370 350 CFM 1110 1110 1110 1110 1110 Watts 119 173 231 291 354 CFM 1050 1050 1050 1050 1050 Watts 104 156 210 268 329 330 CFM 990 990 990 990 990 Watts 91 140 192 247 306 310 CFM 930 930 930 930 930 Watts 78 125 174 228 284 290 CFM 870 870 870 870 870 Watts 67 111 158 209 264 3.5 Ton 450 420 CFM 1575 1575 1575 1575 1575 Watts 289 363 440 519 600 CFM 1470 1470 1470 1470 1470 S9V2C100U4-SUB-1A-EN 5

Heatingand AirflowTables Table 2. S9V2C100U4PSBA/ S9V2C100D4PSBA Airflow(continued) S9V2C100U4PSBA / S9V2C100D4PSBA Furnace Airflow (CFM) and Power (Watts) vs. External Static Pressure with Filter Unit Outdoor Airflow Setting (CFM/ ton) External Static Pressure 0.1 0.3 0.5 0.7 0.9 Watts 241 311 383 458 535 400 CFM 1400 1400 1400 1400 1400 Watts 213 280 349 421 495 370 CFM 1295 1295 1295 1295 1295 Watts 175 237 302 369 439 350 CFM 1225 1225 1225 1225 1225 Watts 152 211 273 338 405 330 CFM 1155 1155 1155 1155 1155 Watts 131 187 247 308 373 310 CFM 1085 1085 1085 1085 1085 Watts 113 166 222 281 343 290 CFM 1015 1015 1015 1015 1015 Watts 96 146 199 256 315 450 CFM 1800 1800 1800 1800 1714 Watts 410 494 580 669 695 420 CFM 1680 1680 1680 1680 1680 Watts 342 420 502 585 671 400 CFM 1600 1600 1600 1600 1600 Watts 301 376 454 534 617 4.0 Ton (a) 370 CFM 1480 1480 1480 1480 1480 Watts 246 316 388 464 541 350 CFM 1400 1400 1400 1400 1400 (a) Watts 213 280 349 421 495 330 310 290 CFM 1320 1320 1320 1320 1320 Watts 183 247 313 381 452 CFM 1240 1240 1240 1240 1240 Watts 157 216 279 344 412 CFM 1160 1160 1160 1160 1160 Watts 133 189 248 310 375 (a) Factory Setting 6 S9V2C100U4-SUB-1A-EN

General Features NATURALGAS MODELS Central Heating furnace designs are certified by the American Gas Association for both natural and L.P. gas. Limit setting and rating data were established and approved under standard rating conditions using American National Standards Institute standards. SAFE OPERATION The Integrated System Control is a solid state device which continuously monitors for presence of flame whenthe systemis inthe heating modeof operation. Dual solenoid combination gas valve and regulator provide additional safety. QUICKHEATING Durable, cycle tested, heavy gauge tubular stainless steel primary heat exchangerquickly transfers heat to provide warm conditioned air to the structure. Low energy power vent blower,to increase efficiency and provideapositivedischarge of gasfumesto the outside. BURNERS Multiport Inshot burners will give years of quiet and efficient service. All models can be converted to L.P. gas with LP conversion kit. INTEGRATEDSYSTEMCONTROL Exclusively designed operational program provides total control of furnace limit sensors, blowers, gas valve, flame control and includes self diagnostics for ease of service. Also contains dry contacts for EAC and HUM. ENERGY EFFICIENT OPERATION Furnaceis certified bythe manufacturer toleak 1%or less of nominal air conditioning CFM delivered when pressurized to.5" water column with all inlets, outlets, and drains sealed. AIR DELIVERY The variable speed blower motor has sufficient airflow for most heating and cooling requirements and will switch from heating to cooling speeds on demand from room thermostat. SECONDARY HEAT EXCHANGER The S-Seriesfurnace hasaspecialtype 29-4C stainless steel secondary heat exchanger to reclaim heat from flue gases which would normally be lost. STYLING Heavygaugesteeland "wrap-around"cabinet constructionis used inthe cabinetwith baked-on enamel finish for strength and beauty. Every orientation has at least two venting options. There are no knockouts on cabinet. FEATURES ANDGENERALOPERATION The S-Series furnace utilizes a Silicon Nitride Hot Surface Ignition system, which eliminates the waste of a constant burning pilot. The integrated system control lightsthe main burnersuponademandfor heatfrom the room thermostat. Complete front service access. a. Low energy power venter b. Vent proving pressure switches. S9V2C100U4-SUB-1A-EN 7

Features and Benefits 96.0% AFUE ACROSS ALLMODELS Meets utility rebates Lowers utility bills ELECTRICALLY EFFICIENT Efficient airflow design reduces electrical energy use 34INCHTALL Lighter,easier to moveand fit intotightspaces like short basements or tight closets Works great with larger, high-efficiency coils No knockouts 3 WAY MULTI-POISE /DEDICATEDDOWNFLOW 9SKU s Upflow/Horizontal Left /Horizontal Right 7SKU s Downflow Added application flexibility and reduction in specification errors AIRFLOW Atleast400CFM/ton at0.5in.h 2 0 externalstatic pressure; setup airflow options down to 290 CFM/ton REGULATORY Allmodelsare air tight;1%or less airleakage as per ASHRAE 193 Open vestibule design provides a full 34 high open vestibule DIMENSIONS Widths are industry standard: 17.5, 21, and 24.5 Depth remains approximately 28 Cabinet will be compatible with industry standard coils, as well as, other accessories INTEGRATEDFURNACE CONTROL Setup/ Status / Diagnostics / Digital Display No dip switches Last six errors stored Dry contact EAC and HUM connections All Molex connections; no spade terminals Low voltage labeled above and below Rain shield over IFC keeps condensate off the control TUBULAR STAINLESS STEELPRIMARY HEAT EXCHANGER 29 4C STAINLESS STEEL SECONDARY HEAT EXCHANGER Stainless steel is a more durable, corrosive-resistant material than aluminumized steel Integrated rail system for easy access if required Reduces or eliminates need for baffles VORTICA II BLOWER,DESIGNEDEXCLUSIVELY FOR THE S-SERIES FURNACE Improved airflow efficiency Durable, easy to clean, two piece housing Single piece belly band/ motor arm assembly Blower deck has full-length rails for easy removal and replacement, regardless of poise THREE WAY MULTI-POISE (UPFLOW, HORIZONTAL LEFT ANDRIGHT) PLUS DEDICATED DOWNFLOW Easier to specify Shipped ready to install (no kits required) Every model has at least two venting options When in horizontal, trap extends only about 2 Barbed fittingon trap athoseconnection and on cabinet transition for hose has barbed fitting and clamps at both ends for leak resistance. Vent table improvements including longer vent lengths;2 pipe canbeused up to 100K 8 S9V2C100U4-SUB-1A-EN

Ingersoll Rand (NYSE: IR) advances the quality of life by creating comfortable, sustainable and efficient environments. Our people and our family of brands including Club Car, Ingersoll Rand, Thermo King and Trane work together to enhance the quality and comfort of air in homes and buildings; transport and protect food and perishables; and increase industrial productivity and efficiency. We are a global business committed to a world of sustainable progress and enduring results. ingersollrand.com Ingersoll Rand has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices. S9V2C100U4-SUB-1A EN 29 Mar 2017 Supersedes S9V2C100U4-SUB-1-EN (February 2016) 2016 Ingersoll Rand all rights reserved