CEM CEM DT-175CV1. AC Current & Voltage Datalogger (P136)

Similar documents
DT-123/125/127/129 P107. Moisture meters DT-8851/8852 P109. Sound Level Meter DT-8894 P113. Thermo-Anemometer with IR temperature DT-8890/8890A P119

1. INTRODUCTION FEATURES SPECIFICATIONS PANEL DESCRIPTION OPERATING INSTRUCTION MAINTENANCE...6

Specifications Minimum Typical Maximum Unit

MicroTool. Not just a simple Measuring Instrument A complete Tool to support your daily activities FLUE GAS ANALYSERS

EasyLog Data Logger Series

ORDERING INFORMATION FEATURES EL-WIN-USB (CONTROL SOFTWARE) Maximum Speci cations Typical Minimum Unit

EasyLog Data Logger Series

EL-USB-TC Thermocouple Data Logger with USB Interface

EL-USB-1-LCD Temperature Data Logger with LCD

EL-USB-2-LCD+ High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD

EL-USB-CO300 Carbon Monoxide (CO) Data Logger with USB Interface

ELMTEC. Kattreppeln Königslutter / /

EL-USB-1-LCD Temperature Data Logger with LCD

onlinecomponents.com

Hygrometer / Air Quality Meter

EL-OEM-3 OEM Packaged Voltage Data Logger

Instruction Sheet THERMOCOUPLE DATA LOGGER WITH LCD DISPLAY AND USB INTERFACE

portable gas analyser

The product can be worked together with our wireless controller to control a ventilator, air cleaning device, or

ECOLOG-NET LA8 and WA8 (wireless), 8 x 4..20mA signals

Multifunction IAQ Monitor


User Guide InfraRed (IR) Thermometer with Wireless Datalogger, Type K input & Laser Pointer MODEL 42560

IRT2 Dual Laser IR Thermometer - User Guide

OPERATION MANUAL TEMPERATURE. HUMIDITY MONITOR / ON-LINE LOGGER. Monitor. On-line Logger AMT208 AMT207

AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER

FIRST CHOICE CATERING SPARES LTD DIGITAL TECHNOLOGY APRIL 2015 FS

R9900. Model. Instruction Manual. Indoor Air Quality Meter. reedinstruments. www. com

Infrared Temperature Sensor

IRtech. E instruments. IRtech Radiamatic IR20 LS series. Infrared Technology

Miniature Infrared Temperature Sensors with Optional Touch Screen Display. PSC-SSS-PM with touch screen display (-CRT version)

THERMOMETERS Dataloggers/Refrigerator

Digital, not analog: One manifold for all refrigeration systems.

VALTRONICS IAQ Monitor

Data Logging Solutions

FLX380-30x FlexTester OTDR

AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER

A bright alpha numeric display and the simplified keypad (three buttons) allow the operation even under harsh conditions.

AE2200 FTTx Multi-Function Meter

WS3650IT-MG-SIL. Technical sheet

Nardalert S3 TM Non-Ionizing Radiation Monitor

TES-1339 INSTRUCTION MANUAL

FS-200. Model. Instruction Manual. Infrared Food Thermometer. reedinstruments. www. com

Users Manual. Visit us at

WS3650IT. Pro Family weather station with T/H sensor, pluviometer, anemometer & PC connection.

Indoor Air Quality Meter Rev. 2.x Meters. The Value Leader TM

VIBRA-series: VIBRA, VIBRA +

GasAlertMicroClip X3 Specifications

BST-MG08/09 Multi-gas Detecting Alarm. Manual Instruction

ALTAIR 5X Multigas Detector Product Specification

M700-Series Multifunction OTDR

CDL 210. Operating manual. CO2 Logger. Best.-Nr

THL2. Temperature/Humidity USB Datalogger INSTRUCTION MANUAL

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL THL1

GL100 series (vol 1, rev 1.0)

Beam-A-Temp Portable Infrared Thermometer Measures up to 1832 F/1000 C with 50:1 distance to target ratio. Specifications

DGC-1000 DIGITAL GENSET CONTROLLER

Advanced Autoclave Controller with Recording + 4 Channel Mapping + Pressure Indication with PC Software & Printer Module

SoundEar 3. Measure, monitor and manage noise in hospitals.

MicroRay IR-100 NEW. Inspection MicroRay IR-100

portable gas analyser

Dräger Pac 6000 Single-Gas Detector

Carbon Monoxide Transmitter

User's Guide. CO 2 Monitor. Model CO200

More Precision. thicknesssensor // The sensor for precise thickness measurements

Mini InfraRed (IR) Thermometer with Type K Input and Laser Pointer

Your competent partner for measuring and services.

Infrared Thermometer with 12:1 Distance-to-Sight Ratio and Temperature Alarm

Instruments. for hydroponics & horticulture 2016

Our photo detectors are offered for both power or energy measurements. Measure as low as a few femtojoules in energy or a few picowatts in power.

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

Temperature/Humidity Monitor. User s Manual

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012

Dräger Pac 8500 Single-Gas Detector

PSE-805A. AL4000 SERIES 100mm chart PEN HYBRID MEMORY RECORDER

Our photo detectors are offered for both power or energy measurements. Measure as low as a few femtojoules in energy or a few picowatts in power.

MLTXD16 Temperature Datalogger with Internal and External Sensor. Accuracy & Resolution ±0.3 C avg res. 0.5 C Storage Temperature -40/85 C

INSTRUCTION MANUAL. Model: 8918 THERMO HYGRO-ANEMOMETER KNT BF FPM MPH MS CKMH

Precision Temperature Humidity Meter DTH184DL User s Manual

Process & TeMPerATUre UniversAl input DigiTAl MeTers


CO warning instruments and gas spillage detectors

Temperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping. Touch Panel PPI

ECOLOG TN2, TN3-P, TN4, TN4-L, TP2, TP4-L,TH1, TH2

THX-DL Data Logger USER & INSTALLATION MANUAL V

CMT MANUAL 6. NMC SENSORS

THA2 TEMPERATURE/ HUMIDITY/ DEWPOINT ALARM WITH LOGGING CAPABILITY. 99 Washington Street Melrose, MA Phone Toll Free

USB Multi Function Dataloggers. RHT30 Humidity/Temperature Datalogger. TH30 Dual Temperature Datalogger

Dual Laser InfraRed (IR) Thermometer

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460)

Model 1062 Environment Monitor

XSD Dry Cabinet

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

Compact Ultra Low Temperature Chamber

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

D3 Wireless temperature alarm & monitoring system family. tek-troniks

User Manual R1.0 CO2Meter, Inc. Personal CO2 Monitor SAN-10

Sirius Technologies, Inc.

Dual Laser InfraRed (IR) Thermometer

Transcription:

Dataloggers Selection Guide Dataloggers Selection Guide DT-175CV1 DT-179 DT-185 DT-186 Carbon Monoxide Datalogger (P164) Light Datalogger (P165) Anemometer Datalogger (P165) AC Current & Voltage Datalogger (P136) DT-171 Humidity & Temperature Datalogger (P161) DT-171T Type-K temperature Datalogger (P161) DT-171V DC Voltage Datalogger (P162) DT-172 Temperature & Humidity Datalogger (P162) DT-178A 3-Axis Vibration Datalogger (P166) DT-173 Sound Level Datalogger (P163) DT-174B Humidity/Temperature & Air Pressure Datalogger (P164) TP - 01 TCP/IP Transmitter 159 160

DT-170/171/171T Temperature and Humidity Datalogger DT-171V/171A DC Voltage / DC Current DataLoggers DATA PC-Link LOGGER 0~100% RH Temperature PC interface Model 171 Model 171V DATA LOGGER PC-Link PC interface You can monitor temperature and humidity values efficiently and conveniently for long time periods by using the Datalogger. The readings are saved in the logger and simply read out by your PC with USB interface. Memory for 16000 (171) readings Temperature datalogger (170) Freely selectable measurement cycle from 2sec. to 24h Battery life: more than 3 years Display all status information through two LEDs Download collected data through USB interface Alarm display if user-defined maximum/minimum values exceed Analysis software used to view graph for logging data 170 171 171T Temp range -40 to 70ºC -40 to 158 F -40 to 70ºC -40 to 158 F Temp ±1ºC ±1ºC Humidity range 0 to 100%RH Humidity ±2%RH Temp K range -200 to 1370 C(-328 to 2498 F) Temp K ±1ºC Memory 32000(16000 each for temperature and humidity) Measuring rate 2sec. to 24h Battery life typically 3 years DT-172/172TK Temperature and Humidity Datalogger 171V 171A DC Voltage range 0 to 30V DC Voltage accuracy ±0.5%+1 ±0.5%+1 DC Current range 4 to 20mA DC Current accuracy ±1%±1Count Reading Memories 32000 readings 32000 readings Measuring rate 400Hz. to 24h 1sec. to 24h 0~100% RH Temperature 3.6V Lithium battery,software and clamshell. Size(HxWxD): 130mm x 30mm x 25mm Weight: 20g DATA LOGGER PC-Link PC interface 3.6V Lithium battery, K-Temp probe(171t), software and clamshell. Size(HxWxD): 130mm x 30mm x 25mm Weight: 20g Model 171T 172 172TK Temp range -40 to 70ºC -40 to 70ºC -40 to 158 F -40 to 158 F Temp ±1ºC ±0.5ºC Humidity range 0 to 100%RH 0 to 100%RH Hunidity ±2%RH ±2%RH Temp K range -200 to 1370 C(-328 to 2498 F) Temp K Above -100 C (-148 F): 0.15%rgd+1.0 C(1.8 F) Blow -100 C (-148 F): 0.5%rgd+2.0 C(3.6 F) Memory 32000(16000 each for temperature and humidity) Measuring rate 1sec. to 24h Battery life typically 3 years 3.6V Lithium battery, K-Temp probe(172tk), software and clamshell. Size(HxWxD):94mm x 50mm x 32mm Weight: 91g 161 162

DT-173 Sound Level Datalogger DT-174B Temperature/Humidity & Air Pressure Datalogger IEC61672-1 CLASS2 MAX & MIN measurements Alarm value setup A & C Weighting NORM(Normal) & PEAK mode 25ms sample interval FAST & SLOW response Manual and Automatic mode Standard applied IEC61672-1 CLASS2 ±1.4dB Frequency range 31.5HZ ~ 8kHZ Dynamic range 50dB Level ranges Auto: 30dB~130dB Frequency weighting A/C Time weighting FAST ( 125ms ), SLOW ( 1s ) Memory Readings 129920 points for dba or dbc Sample rate 1 Sec. to 24h Microphone 1/2 inch electret condenser microphone Data output USB data traffic Model 173 Size(HxWxD): 106mm x 56mm x 33.5mm Weight: 34g 3.6V Lithium battery, stand, software and clamshell. Alarm setup and indication Recording and low battery indication Manual and automatic start mode USB port for data traffic and power supply Status indication via Red/Yellow LED and Green LED Data Memory 10000 Sampling rate 1 min to 18 hours Data output USB Temperature Range -40~70ºC/-40~158ºF Resolution 0.1ºC/0.1ºF 40 to 70ºC/104 to 158ºF ±2ºC/3.6ºF 0 to 40ºC/32 to 104ºF ±1ºC/1.8ºF -40 to 0ºC/-40 to 32ºF ±2ºC/3.6ºF Humidity Range 0~100%RH Resolution 0.1%RH 0 to 20 and 80 to 100% ±5% 20 to 40 and 60 to 80% ±3.5% 40 to 60% ±3.5% Air Pressure Range 950~1050hPa Resolution 0.1hPa ±0.25%FSO(25 ºC) Repeatability ±0.2%(Max ±0.3%FSO) Linearity/Hysteresis ±0.24%FSO Temperature coefficient ±0.1%FSO DT-174 Temperature/Humidity & Pressure Datalogger Size(HxWxD): 145mm x 35mm x 30mm Weight: 49g 3.6V Lithium battery, software and clamshell. DT-174 provides much faster, accurate and stable readings with temperature, humidity & air pressure which is in better precision. The windtight design of the meter proof against damp and water. The datalogger provides accurate readings with temperature, humidity & air pressure. For the three group data of Temperature, Humidity and Air Pressure, about 10900 readings of each can be recorded. For one group, about 32,700 data can be recorded. Freely selectable measurement cycle from 1 sec. to 24h. Sound & light alarm indication if user-defined maximum/minimum values exceed. Larger LCD display date, time, temperature, humidity, air pressure and upper/lower limit value. Built-in USB PC interface. Function Range Basic Resolution Relative Humidity 0 to 100%RH ±3.0% 0.1%RH Temperature -40 to 70ºC (-40 to 158ºF) ±1ºC/1.8ºF ±0.1ºC/0.1ºF Dew Point Temperature -40 to 70ºC (-40 to 158ºF) ±2ºC/4ºF ±0.1ºC/0.1ºF Air Pressure 0-30PSI/0-2000hPa 0.01PSI/1hPa ±0.2% Logging rate Selectable sampling interval: From 1 Sec. to 24h Operating temperature -35 to 80ºC (-31 to 176ºF) Battery type 3.6V lithum (SAFTL14250, Tadiran TL-5101 or equivalent) Size(HxWxD): 132mm x 66mm x 37mm Weight: 180g 3.6V Lithium battery, software and clamshell. DT-179 Carbon Monoxide Datalogger Alarm setup and indication Recording and low battery indication Manual and automatic start mode USB port for data traffic and power supply Status indication via Red/Yellow LED and Green LED Memory Measuring rate Measurement Range Measurement Resolution Warm up period Sensor type Typical sensor life Size(HxWxD): 145mm x 35mm x 30mm 32000 readings 2sec. to 24h 0 to 1000PPM 1PPM ±5% or ±10PPM Less than 2 seconds Stabilized electrochemical Gas-specific (CO) 3 years Weight: 49g 3.6V Lithium battery, software and clamshell. 163 164

DT-186 Anemometer Datalogger DT-178A/178B 3-Axis Vibration Datalogger/ Temperature and Humidity Datalogger Alarm setup and indication Recording and low battery indication Manual and automatic start mode USB port for data traffic and power supply Status indication via Red/Yellow LED and Green LED Memory Measuring rate Measurement Range Measurement Resolution Warm up period 32000 readings 2sec. to 24h 0.40 to 30.0m/s 0.1m/s ±3.5% ± 0.2m/s Less than 2 seconds Size(HxWxD): 145mm x 35mm x 30mm Weight: 49g 3.6V Lithium battery, software and clamshell. DT-178A DT-178B Records 3-axis shock Build-in accelerometers Measures dynamic and static acceleration Real-time operation Freefall detection mode User settable trigger levels Real-Time FFT High speed download(usb2.0) Vibration, humidity and temperature Datalogger * DT-178A DT-178B Acceleration Sensor:MEMS Semiconductor Acceleration Sensor sampling Rate:256Hz Acceleration Range:±18g Acceleration Resolution:0.00625g Acceleration :±0.5g Non-Linearity:±1% Bandwidth:Approx. 0 ~ 60Hz Trigger Range: 0 to 18g (XYZ magnitude) Temp & Humidity Range:-40 to 70ºC/-40 to 158ºF * 0 to 100%RH Temp & Humidity Resolution:0.1%RH/0.1ºC/ºF * Temp & Humidity :±2%RH/1ºC/ºF * Sampling Rate:1sec. to 24hours Memory:8Mbit FLASH (Memory for 504126 samples, about 168042 samples/.axis for x, y and z axis seperately) Size(HxWxD): 130mm x 30mm x 25mm 3.6V Lithium battery, software and clamshell. Weight: 20g DT-178A is engineered to record acceleration data of vibration, it will record and time 3-axis vibrations and peaks to provide a history of shock/vibration conditions. and it will record the time when freefall happens. It measures and computes real-time spectral data using an FFT(Fast Fourier Transform) from 0 to 60 Hertz. The DT-178B is Vibration, humidity and temperature Datalogger Model 178A DT-185 Light Datalogger Recording the effection for buildings under construction Recording the effect ion for equipments under the natural disaster Alarm setup and indication Recording and low battery indication Manual and automatic start mode USB port for data traffic and power supply Status indication via Red/Yellow LED and Green LED Recording the safety transporting for expensive items Memory 32000 readings Measuring rate 2sec. to 24h Measurement Range 0 to 40 klux/0 to 37kFc. Measurement Max. Resolution 0.1Lux/0.1Fc. ±5% Warm up period Less than 2 seconds Size(HxWxD): 145mm x 35mm x 30mm Weight: 49g 3.6V Lithium battery, software and clamshell. Recording the examing level of the sportsmen Recording the safety transportation 165 166

IT-1800A Humidity & Temperature Datalogger with TCP/IP transmitter (TP-01) IT-1800A Humidity & Temperature Datalogger with TCP/IP transmitter (TP-01) Humidity & Temperature Datalogger with TCP/IP transmitter (TP-01) Humidity & Temperature sensor with wireless transmitter 1800A Humidity & Temperature Datalogger with TCP/IP transmitter provides the TCP/IP connection between the LAN and the internet of the world. TCP/IP (TP-01) shares the LAN with other users and further transmit the packet of data to the global clients and server system. Capacity 180,000 Data memory LCD to show some logging information easily Alarm display if user-defined maximum/minimum values are exceeded Analysis software used to view graph for logging data LEEE 802.3 is compatible with internet Combination of Mac, 10 Base-T and TCP/IP Model: 1800A Specification Meas. range 0 to 100%RH, -40 to 70ºC ±2%RH, ±0.5ºC Resolution 0.1%RH,0.1ºC Capacity 180,000 Data memory Analysis software windows 98/2000/XP/Vista TCP/IP transmitter %RH & Temperature Datalogger Size(HxWxD): 196mm x 174mm x 71.5mm Weight: 495g AC adaptor, Software, USB cable, Gift box with carrying case. Model: TP-01 TCP/IP Internet transceiver LAN COM 167 168

DT-21/22/2232 Multifunction Environment Meters DT-8820 4 in 1 Multifunction Environment Meter Temperature 0~100% RH LUX db FC 35~100 db Light (LUX/FC) Model 21 21/22/2232 digital Multifunction Environment Meter have been designed to combine the functions of Sound Level Meter, Light Meter, Humidity Meter, and Temperature Meter. They are ideal Multifunction Environment Instruments with scores of practical applications for professional and home use. The 4 in 1 digital Multifunction Environment Meter has been designed to combine the functions of Sound Level Meter, Light Meter, Humidity Meter, and Temperature Meter. It is an ideal Multifunction Environment Meter Instrument with scores of practical applications for professional and home use. The Sound Level function can be used to measure noise in factories, schools, offices, home, etc, checking acoustics of studios, auditoriums and hi-fi installations. The Light function is used to measure illuminance in the field. It is fully cosine corrected for the angular incidence of light. The light sensitive component used in the meter is a very stable, long life silicon ciode. The Humidity/Temperature uses a humidity/semiconductor sensor and K type thermocouple. Temperature 0~100% RH db 35~100 db LUX FC Light (LUX/FC) & LVD EN: 61010-1, EN: 61010-02-031 EN 61010-1 CATII 600V 21:5 in 1 higher performance multi tester. 22: 4 in 1 environment meter. It is mini size with high technology for professional use. 2232: 4 in 1 multifunction environment meter with PC Interface. 4 in 1 for Light meter, Sound level meter, Humidity/Temperature meter 3 1 /2 large LCD display Data Hold and Max Hold Auto Power Off "OL" Over-range indication "BAT" Low battery indication Total accuracy: for C.I.E standard illuminate A(2856K) 21 22 2232 Digital display counts 2000 2000 4000 PC Interface * Auto power Off Low battery indication * Multimeter Function * Function Range Resolution (%rdg+digits) Temperature -20ºC~200ºC 0.1ºC ±(3.0%+2ºC) -20ºC~750ºC 1ºC ±(3.0%+2ºC) 150ºC; ±3.0% 150ºC -4ºF~200ºF 0.1ºF ±(3.0%+2ºF) -4ºF~1400ºF 1ºF ±(3.0%+2ºF) 302ºF; ±3.0% 302ºF Light 20,200,2000,20000 0.01,0.1,1 ±(5.0%+10d) (2000 x 10 Lux) Humidity 35%~95%RH 0.1%RH ±5.0%RH at 25ºC Model 8820 Model 22 Function Max Range Resolution Basic 21 22 2232 Light 20,000Lux 0.1Lux ±0.5%±10d 40,000Lux * Sound 100dB 0.1dB ±3.5dB 130dB * Humidity 95%RH 0.1%RH ±5%RH * Temperature 1300 C 0.1 C ±3%±1d 750 C/1400 F 0.1 C/ F ±3%±2d * Voltage DC 600V 0.1mV ±0.5%±2d * Voltage AC 600V 100mV ±1.2%±10d * Current DC 10A 0.1uA ±1.0%±2d * Resistance 2MΩ 0.1Ω ±0.8%±2d 40MΩ Sound Level 35dB~100dB 0.1dB ±3.5dB at 94dB sound level, 1KHz sine wave Size(HxWxD): 251mm x 63.8mm x 40mm Weight: 250g Size(HxWxD): 121mm x 60.6mm x 40mm Weight: 280g Model 2232 22: Rubber holster, 9V battery, Test leads and K-Type temperature probe. 2232: Rubber holster, Test leads, K-Type temperature probe, 9V battery, RS-232 PC cable & Software diskette. 9V battery and K-type temperature probe, humidity probe, light probe, gift box with carrying case. 221 222

DT-8898/8899 Professional Multifunction Environment Meters DT-8898/8899 Professional Multifunction Environment Meters Professional Multifunction Environment Meters The digital Multifunction Environment Meter has been designed to combine the functions of Sound Level Meter, Light Meter, Humidity Meter, Type K Thermometer and Infrared Thermometer. It is an ideal Multifunction Environment Meter Instrument with scores of practical applications for professional and home use. db 30~130 db Type K TEMP. 0~100 %RH IR IR Temperature Backlight The Sound Level function can be used to measure noise in factories, schools, offices, home, etc, checking acoustics of studios, auditoriums and hi-fi installations. The Light function is used to measure illuminance in the field. It is fully cosine corrected for the angular incidence of light. The light sensitive component used in the meter is a very stable, long life silicon ciode. The Humidity/Temperature use a humidity/semiconductor sensor and type K thermocouple. 4 in 1 db, %RH, Type K & IR Temperature 8898 8899 4 in 1 for db, %RH, Type K and InfraRed Temperature(ºC/ºF). * 5 in 1 for Anemo, %RH, Lux(Fc), Type K and InfraRed Temperature(ºC/ºF). * Large dot-matrix LCD (Resolution 160 160) with backlight. Relative time clock on MAX MIN and AVG provides a time reference for major events. Difference functions simultaneous display. USB interface, USB to UART Bridge Controller. 5,000 records data logger per channel. Low battery indication, and Auto Power Off mode (Sleep mode) increases battery life. Function Range: Resolution 8898 8899 TYPE K Temp -200 C to 1372 C (-328 F to 2501 F) IR Temp -30 C to 550 C (-22 F to 1022 F) 0.1 C/ F/ K <1000, 1 C/ F/K 1000 0.1 C/ F/ K Above -100 C (-148 F) ±[0.15%rgd+1 C(1.8 F)] Blow -100 C (-148 F) ±[0.5%rgd+2 C(3.6 F)] Above -10 C(14 F) ±[2.0%rgd+20C(3.6 F)] Blow -10 C(14 F) ±5 C( 9.0 F) TYPE K-IR Temp 0.1 C/ F/ K Above -10 C(14 F) ±[2.0%rgd+3 C(5.4 F)] Blow -10 C(14 F) ±6 C(11 F) Air Temp -30 C~100 C (-22 F~199 F) 0.1 ±0.5 C/0.9 F IR IR Temperature Backlight Model 8898 Type K TEMP. 0~100 %RH Air Flow LUX FC Light (LUX/FC) Humidity 0~100%RH 0.01 ±2%RH Sound Level 30dB~130dB 0.1dB ±1.5dB * Light 20,200,2000, 20000, 200000Lux 0.01,0.1,1 ±5% ±10d * 5 in 1 Anemo 0.40-30.00 m/s 0.01 ±3% ±0.20 m/s * 80-5900 ft/min 1 ±3% ±40 ft/min * 1.4-108.0 km/h 0.1 ±3% ±0.8 km/h * 0.9-67.0 MPH 0.1 ±3% ±0.4 MPH * 0.8-58.0 Knots 0.1 ±3% ±0.4 knots * Anemo, Light, %RH, Type K & IR Temperature Air Flow 0-999,900ft 3 /min 0.001 to 100 0.000-999.9ft 2 0-999,900m 3 /min 0.001 to 100 0.000-999.9m 2 Size(HxWxD): 255mm x 75mm x 50mm Weight: 355g 9V battery, K-type temperature probe, IR temperature probe, %RH probe, db probe, Anemo probe and gift box with carrying case. Model 8899 223 224

DT-9880 4 in 1 Particle Counter with TFT color LCD display & Camera function Particle Counter DT-9880 4 in 1 Particle Counter with TFT color LCD display & Camera function 9880 is 4 in 1 Particle Counter with 2.8 color TFT LCD display & a microsd memory card for capturing images(jpeg) or video(3gp) for viewing on your PC, providing fast, easy and accurate readings for particle counter, GAS (HCHO,CO) detectors, air temperature & relative humidity, most surface temperature measurements. It is the first combination of these measurements in global, would be the best instrument for environment protection and energy save. The dewpoint temperature measurement will be very visiable for wet and dry proof. It is a good hand for industrial measurements and data analyzing, the real scene and time can be displayed on color TFT LCD. Any memory readings can be recorded in SD card The user can be back in office to analyze the measured air quality under the support of software. Model 9880 2.8" TFT 320x240 pixels Color LCD display Images(JPEG) & Video(3GP) Simultaneously measure and display 6 channel of particle sizes, measure particle size down to 0.3 µm IR temperature measure & Laser targeting GAS (HCHO,CO) detectors Air temperature and humidity, Dewpoint & Wet bulb temperature Max, Min, DIF, AVG record, Date/time setup controls, High and low alarm Adjustable emissivity & Trigger lock MicroSD (MAX. use 8GB) memory card, Bluetooth /USB interface Auto Power Off Selectable sample time, count data, programmable delay Store 5000 records of date, time, counts, relative humidity, temperature, sample volumes, alarms and location label Language selection English, Chinese, French, German, Spaish Specifications Particle Counter Channel Flow Rate Count Modes Coincidence Loss IR Temperature Measure IR Temp. Range Optical Resolution Emissivity Adjustable Response Time Air Temperature Measure Air Temp Range Humidity Range Dew Point Temp. Range Wet Bulb Temp. Range GAS Detectors HCHO (methanal) Range CO (carbon monoxide) Range 0.3, 0.5, 1.0,2.5, 5.0, 10μm 0.1ft3(2.83L/min) controlled by internal pump Totalize, Concentration, Audio 5%, 2000000 particles per ft3-20.0ºc to 500.0ºC/-4.0ºF to 916ºF ;Basic : ±1.5% of reading 8:1 Distance to Spot size 0.10~1.0 Adjustable 500mS 0 to 50ºC/32 to 122ºF; Basic :±0.5ºC/1ºF 0 to 100%RH; Basic :±2.5%RH(20%~80%RH) -30~100ºC/ -22~199ºF 0~80ºC/ 32~176ºF Temp./%RH Sensor Particle Sensor 0.01~5.00ppm; Basic : ±5%± 0.01ppm 0~1000ppm; Basic :±5% ± 10ppm IR Temperature Sensor Camera Sensor GAS (CO,HCHO) Sensor Size(HxWxD): 240mm x 75mm x 57mm Weight: 570g USB Interface NiMH battery, gift box with carrying case. DT-9880 2.8 2.8 TFT color LCD display Support Video(3GP) capture capabilities Particle Counter Particle Support Images(JPEG) capture capabilities Support Particle measurement Laser targeting Date/Time setup controls CO HCHO IR AIR AIR Dewpoint %RH Wet bulb Support Harmful Gases measurement Support IR, Air, Dewpoint, Wet bulb Temp. & Air Humidity measurement www.cem-meter.com.cn USB interface Data Logger Support MicroSD memory card extention 225 226 www.cem-meter.com.cn

DT-8502/8503 Complete Air Quality Meter DT-8502/8503 Complete Air Quality Meter Complete Air Quality Meter The complete air quality meter offers an unparalleled featureset for HVAC and facilities technicians, helping them work more quickly and accurately, with the ease of use and durability customers expect meter. Model 8502 Simultaneously measures, logs, and displays temperature, humidity, CO 2, and CO on a bright, backlit LCD display Maintenance free NDIR (non-dispersive infrared) CO 2 sensor One-touch air flow and velocity with available probe Wet bulb and dew point temperature % of outside air calculation CO 2 and CO field calibration feature Min/Max/Average on all measured and calculated readings Audible and visual threshold alarms Extensive discrete or continuous data logging capacity, downloadable to PC via USB interface Model 8503 Function Range Resolution 8502 8503 CO 2 0-8000ppm 1ppm ±75ppm(0-2000ppm) ±10%(2000-8000ppm) CO 0-1000ppm 1ppm ±5% or ±10ppm * Temperature -20 to 60 C -4 to 140 F 0.1 C/0.1 F ±0.9 C/1.62 F(40 to 60 C/74 to 140 F) ±0.5 C/1 F(5 to 40 C/41 to 74 F) ±1.1 C/1.98 F(-20 to 5 C/-4 F to 41 F) Humidity 10 to 90%RH 1%RH ±2.5%RH Dew Point Temp -44 to 57 C -47 to 135 F 0.1 C/ F ±1 C(-20 to 60 C/40 to 90%RH) ±2 C(-20 to 60 C/20 to 60%RH) ±4 C(10 to 20%RH) Wet Bulb Temp -16 to 57 C 3 to 135 F 0.1 C/ F ±1.2 C(-20 to 60 C/20 to 90%RH) ±2.1 C(10 to 20%RH) Size(HxWxD): 307mm x 78mm x 57mm Weight: 355g NiMH battery, gift box with carrying case. DT-802 Desktop Indoor Air Quality CO 2 Monitor Model 802 Checks for Carbon Dioxide (CO 2 ) concentrations with Max/Min value recall function Maintenance free NDIR (non-dispersive infrared) CO 2 sensor Indoor Air Quality displayed in ppm with Good (380 to 420ppm), Normal (<1000ppm), Poor (>1000ppm) indication Visible and Audible CO 2 warning alarm Displays Year, Month, Date, and Time Automatic Baseline Calibration (minimum CO 2 level over 7.5 days) or manual calibration in fresh air Function Range Resolution CO 2 0-9999ppm 1ppm ±75ppm(0-2000ppm)/±8%(2000-9999ppm) Temperature -10 to 60 C/14 to 140 F 0.1 C/ F ±1 C/1.8 F Humidity 0.1 to 99.9%RH 0.1%RH ±3%RH(25 C/30 to 99%RH) ±4%RH(25 C/0 to 30%RH) Size(HxWxD): 110mm x 105mm x 61mm Weight: 230g NiMH battery, gift box with carrying case. 227 228

CO 2-5000 Green-House Series Green-House Series CO2-5000 Green-House Series CT-01 Conductivity Tester DT-176 Waterproof ph Meter Accurate Nutnient Meter Auto power On/Off Waterproof No calibration Required Size(HxWxD): 395mm x 30mm x 26mm Weight: 130g Batteries and Gift box. Flat surface electrode design provides fast and easy on-the-spot ph measurements Range 0.00 to 14.00pH Temperature -5 to 90 C (23 to 194 F) Resolution 0.01pH, 0.1 ±0.01pH, ±1 C/±1.8 F Size(HxWxD): 160mm x 38mm x 30mm Weight: 83g Four 3V CR3032 button batteries, clamshell. HT-24 Wireless Humidity/Temperature Switch with Timer function T-12/T-12B/T-12S Timers Series Temperature/Humidity Sensor Terminals for RF system (DT-180) Measure Temp. range: -40~70ºC(-40~158ºF) Measure Humidity range: 0~100%RH Model HT-24 Model T-12B Temp./Humidity Wireless Receiving & Time system (HT-24) Input power Amps requirments Min/Max operating temperature Min/Max operating Humidity Storage temperature Temperature measurement range Humidity measurement range Temperature CO 2 Measurement range CO 2 110V-240V 15Amps -10ºC to 50ºC (14ºF to 122ºF) 0 to 95%RH -10ºC to 50ºC (14ºF to 122ºF) -10ºC to 50ºC (14ºF to 122ºF) 0 to 99%RH ±1ºC (± 1.8ºF) 0-5000PPM ±50 PPM or ±5% of measured value CO 2 sensor warn-up time <120s Baud Rate 9600bps Possess 12Vdc signal control CO 2 disable function Life expectancy >10years Larger LCD display year, month, day, hour, minute with green backlight PC interface Optional USB CO2 sensor type NDIR Size(HxWxD): 208mm x 170mm x 110mm Weight: 1310g Battery and USB cable, CD software, AC adaptor, Gift box with carrying case (HT24/T-12/T-12S/T-12B) Operation: 24 hours and 7 days & 24 ON and 24 OFF Minimum Setting Interval: 1 minute Count-down programme: MAX, 59hrs, 59mins, 59secs Alarm: MAX, 24 times daily, 1-59 secs alarm time setting Reset and Recall functions & LED power-on indicator Large LCD display with time, temp, %RH function indication Group Settings: MO. TU. WE. TH. FR. SA. SU(any day) MO. TU. WE. TH. FR. SA. SU(every day) Power Input: 100-250V, AC 50/60Hz Output Capacity(resistive): 16A, 20A, 30A, 70A (option) Working Temperature: ±5 C~±55 C DT- 25 Home Energy Check Size(HxWxD): 140mm x 72mm x 43mm Weight: 280g Battery and clamshell. Model 180 Size(HxWxD): HT-24/T-12S: 140mm x 72mm x 43mm Weight: 214g (HT-24/T-12S) Size(HxWxD): 180: 94mm x 50mm x 32mm Weight: 91g (180) Battery and clamshell. Model T-12 Battery and clamshell. Model T-12S The Home Energy Check which you acquired is a power-measuring device which complies with the latest state of the art. It will enable you to determine the costs you will incur for the energy of your "current eaters" in a simplest way. Operating voltage 230 V A.C., 50 Hz Tolerance ± 1% ± 1 W (max. ± 2 % and ± 2W) Measurements range 2,500 W; max. ± 4 % for measurements exceeding 2,500 W Input/Output Earthing protective contact plug and socket Maximum amperage Approx. 13 A Max. power 3,000 W (= 3 kw = abt. 13 A x 230 V) Overflow indication Flashing signal from abt. 3,070 W Working temperature From +10 C to +40 C, rel. humidity of air < 75 %, noncondensing 229 230