Parameterisable compact fault annunciator with permanent display

Similar documents
Universal fault annunciator for panel mounting

Panel Mounted Fault Annunciator Series

MSM - Expansion modules

THE SOLUTION. MSM-Product family OPERATING MANUAL. A fault annunciator of the. BSM Basic fault annunciator for panel mounting. INFOwww.ees-online.

Window facia fault annunciators

Panel Mounted Fault Annunciator Series

Panel Mounted Fault Annunciator Series

Panel Mounted Fault Annunciator Series

Panel Mounted Fault Annunciator Series

Remote alarm indicator and test combination MK2430

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

M1000 Alarm Annunciator

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

1.7. Insulation fault evaluators EDS460/490 EDS461/491

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage

AO Annunciator Module

Universal fault annunciator for panel mounting

Annunciator Unit SACO 16 D1. Product Guide

LINETRAXX VMD420. Multi-functional voltage relay for 3(N)AC systems, frequency/overvoltage/undervoltage, phase, phase failure, asymmetry

Operating Manual VMD420

Insulation fault evaluator EDS460-DG

Annunciator unit. Application

System 9000TS Sequence of Events Recorder

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

ME 3011C / Alarm Indication / Quick Reference Guide

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

1.7. Insulation fault evaluators EDS460/490 EDS461/491

Analog Annunciator Unit SACO 16 A3. Product Guide

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

TCM-2 Thyristor Control Module DATA SHEET

www. ElectricalPartManuals. com Annunciator unit Features Self-contained microprocessor-based annunciator unit with 64 alarm channels Application

Connections, displays and operating elements C D E G H. Installing the control unit

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

Monitoring Devices 11/1

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

On the job around the clock 24/7: Fire detection systems

SUPREMATouch. Modular Fire & Gas Detection System

ME 3011 compact. Electronic Alarm Indication Systems. Power Station Control Systems. Automation Equipment. Power Distribution Control Systems

ISOMETER IR1575. Insulation monitoring device for unearthed AC/3(N)AC systems up to 480 V and DC systems up to 480 V

Interface and EOL Modules 8

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems)

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

RTK 9000TS system. MTL sequence of events recorder. Technical data MTL process alarm equipment

ISOMETER isomed427p. Application Medical IT system in accordance with IEC , IEC , IEC and DIN VDE

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances

The EN54 Part 2 & 4 Fire System

SUPREMATouch. Modular Fire & Gas Detection System

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

Multi-Gas-Controller MGC2

System 9000TS Sequence of Events Recorder

Product Information. PipeMonitor District Heating Monitoring with Leak Localisation

RCMA423-DM RCMA423-DM1C RCMA423-DM2C RCMA423-DM3C. Operating Manual

DEIF A/S. Technical Manual. Type EC-2 Engine Control Unit D. Technical Manual

DRAFT 20 October 2014

Type 8001 PRIME MOVER CONTROLS INC. ALARM ANNUNCIATOR TYPE8001 FEATURES SB 8001B

TM800. Remote alarm indicator and operator panels

PolyGard 2-channel Gas Controller MGC-03

Refrigeration and Air Conditioning Technical leaflet. Electronic controller EKC 201 and EKC 301

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

Process Alarm Solutions

System 9000TS Event Recorder

QA16 Addressable System

Engineering Guideline. pac- Carriers Type Universal

Speed and Frequency Seite 1 von 7

DATAssure. Laboratory wireless alarm & monitoring system

Product overview. Alarm indicator, operator and display panels

HRX Technical Manual. Version 1.2

KNX module for smoke alarm devices Dual/VdS and Q-Label (Order no )

Interface Modules for SENTRI

Installation / Monitoring Technique

GMA200-MT. Operation Manual. Gas detection controller for mounting rail assembly

IT system floor-standing distribution

GMA200-MW16. Operation Manual. Gas detection controller for wall mounting

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

General Specifications

Local Control Network - building controls in perfection

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Radio fire warning panel SRC 3000

Automation System TROVIS 5400 Boiler Controller TROVIS 5474

Instruction manual MTL process alarm equipment. October 2016 CSM 725B rev 2 MTL RTK 725B. Configuration Software Manual

Entwicklung + Fertigung + Service: Heerweg 15 D, Denkendorf Tel.: / Fax.: /

isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

XC10 Extinguishing control panels

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS

Operating Manual RCM420

Signal Processing System ME30 infobox

M2000 Engine Controller

1 measurement signal input 4-20 ma for connection to an external gas sensor 5 freely programmable alarm switching points per measuring point

M2500 Engine Controller Installation Manual

Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01

AE-CU Adaptive Escape Routing for Emergency Lighting. From static to adaptive escape routing

CMD420 / CMD421 Series

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

Call stations and extensions

Standard Devices. Electronic Alarm Indication Systems. ME 3011b

Products no longer available

Transcription:

Parameterisable compact fault annunciator with permanent display FSM 10 Drop-flap fault annunciator 31.08.2010 Permanent display even on power failure Compact module for 10 alarms Supply and alarm signal voltage 12 V...250 V AC/DC Indication with 10 green indicating discs with green LED Live contact and nonvolatile history- / eventmemory ( time resolution 5 ms ) 4 output relays and 4 programmable buttons, 6 functional inputs 2 parameterisable collective reports and internal horn Parameterisation via DIP switches or PC programm Pluggable connection terminals ( Screw- or spring cage terminals ) Marker strips pocketable into transparent window Data sheet MSM-FSM-DB-UK-004

FSm 10 drop-flap fault annunciator Functional description The compact FSM 10 drop-flap fault annunciator is installed in a housing for panel-mounting according to DIN 43781. It has 10 green indicating discs, each featuring a LED for displaying the signals. With very compact design, the fault annunciator offers energy-independent long-term storage of active signals via bi-stable mechanical indicating elements. No battery backup is required. The messages are clearly visible at any time irrespective of lighting conditions. The integrated event memory, which can be read via the serial interface, enables simple archiving of events. Via the optional printer, the events can be documented immediately or at the push of a button. The drop-flap fault annunciator comprises the following functional components: 10 indicator elements with integrated LED 10 galvanically separated reporting inputs (E1... E10) 6 galvanically separated, freely parameterisable function inputs (F1... F6), e.g. acknowledgement, printer control etc. Alive LED 4 programmable output relays with change-over contacts (R1... R4) 4 programmable buttons (e.g. acknowledgement, printer control, lamp test etc.) 10 DIP switches for basic parameterisation 2 CAN bus connection sockets for parallel connection up to 4 fault annunciators (flashing synchronisation, joint acknowledgement, lamp test etc.) and the connection of expansion modules RS 232 interface for connecting a laptop (parameterisation, reading the event memory) or for connecting a serial printer real-time clock with battery backup and connection socket for external DCF 77 aerial various Status LEDs (RS 232, DCF77, CAN BUS) A maximum of 4 FSM 10 can be networked via the CAN bus and thus consolidated to form a group. This leads to a system, in which all 40 reporting inputs, 16 keys and 24 function inputs can be processed in each individual component. The fault annunciator can realise different reporting procedures. The options range from simple standards, such as first or new-value messaging, to complicated application-specific procedures. The indicating disks, associated LEDs and output relays are controlled and the effect of the keys and function inputs determined depending on the alarm sequence. In the basic fault annunciator parameterisation, the device can be set to the most common reporting procedures via DIP switch. Additional setting options are available through software parameterisation, enabling very flexible adaptation of the fault annunciator to almost any task. For example, two reporting groups may be formed that can even realise different reporting procedures. Application examples Climate control supervision in railroad vehicles Food supervision Monitoring of transformer and stationary or mobile emergency power generators Industry and chemical plants Replacement of conventional drop flap relays Configuring via DIP switch In the delivery state, the fault annunciator is pre-parameterised and in most cases can therefore easily be adapted to a particular application via the DIP switches provided at the rear. The following basic settings apply: reporting sequence ( first-up value / new value ) triggering of the inputs 1 5 with NO or NC contacts triggering of the inputs 6 10 with NO or NC contacts collective report 1 standard or inverted collective report 2 standard or inverted automatic horn acknowledgement on or off horn suppression with follow-up message on or off unit No. (1 4) Page 2 of 8

an annunciator from the MSM product family Parameterising via PC In order to adapt the fault annunciator to a wide range of different applications, the following parameter can be modified additionally: delay times for each individual alarm input NC or NO processing for each individual alarm input assignment of the inputs to the two reporting groups definition of the reporting procedure for the reporting groups definition of the key functions and function inputs assignment of relay function to the outputs (e.g. 1..2, horn 1, horn 2, alive message) horn sounding duration with automatic acknowledgement Logging Appearing events will be logged with a time stamp in the non-volatile event memory. Thereby parameters can be assigned which events are to be logged. incoming message receding message button or function input activated incoming first value incoming supply voltage receding supply voltage The data sets of the history file can be distributed over keystroke or activation through one of the function inputs over the RS 232 interface. A version in the ASCII format and the drive of a printer are possible. Different printer drivers are available. On request we supply you with your custom predefined parameter settings for your application. Alarm sequence new-value sequence with 1-frequency flashlight and single acknowledgement first-up-value sequence with 1-frequency flashlight and single acknowledgement new-value sequence with 2-frequency flashlight and single/double acknowledgement first-up-value sequence with 2-frequency flashlight and single/double acknowledgement The indicating discs are always green when the corresponding LED flashes or shines steadily. Further information to the integrated alarm sequences can be found in the seperate document Alarm sequences of the EES fault annunciators ( Filename SM-MA-ZI-UK ). Page 3 of 8

FSm 10 drop-flap fault annunciator Collective report Collective report Function Meaning Horn triggering 1 static / parallel to input The collective report is set by the first upcoming alarm and is still active as long as there is an alarm lining up. It is reset automatically without acknowledgement when all alarms have gone. 2 static / parallel to output The collective report is set when an alarm is upcoming and only resets if all alarms have been gone and been acknowledged. Function Description Meaning Horn triggering (adjustable per DIP-switch) Horn acknowledgement retriggerable not retriggerable manual ( continous tone ) automatic ( pulse tone ) Horn will be retriggered, even if there are messages already lining up. Horn will only be retriggered, if no messages are longer present Horn will be acknowledged manually via button or on functional input. Horn will be acknowledged according to the preset time Horn locking none Horn can always be acknowledged Message acknowledgement Horn acknowledgement is only possible after acknowledging the message Technical data Type FSM 10-0/12AD/12AD/12AD/0 FSM 10-0/24AD/24AD/24AD/0 FSM 10-0/60AD/60AD/60AD/0 Article no. 58FSM1000000 58FSM1001110 58FSM100E330 Supply voltage Rated voltage Range 12 V AC/DC 10 19 V DC 8 13 V AC 24 V AC/DC 19 37 V DC 14 26 V AC 48 V AC/DC + 60 V DC 37... 73 V DC 26... 51 V AC Insulation of the supply voltage against all other voltages 500 V RMS 500 V RMS 500 V RMS Voltage of the reporting and function inputs Rated voltage Range 12 V AC/DC 9 35 V AC/DC 24 V AC/DC 18 50 V AC/DC 48 and 60 V AC/DC 28... 75 V AC/DC Input resistance approx. 5 kω approx. 10 kω approx. 22 kω Page 4 of 8

an annunciator from the MSM product family Type FSM 10-0/110AD/110AD/110AD/0 FSM 10-0/220AD/220AD/220AD/0 Article no. 58FSM1004440 58FSM1005550 Supply voltage Rated voltage Range Insulation of the supply voltage against all other voltages Voltage of the reporting and function inputs Rated voltage Range 110 V AC/DC 100... 370 V DC 85... 264 V DC 220 V AC/DC 100... 370 V DC 85... 264 V DC 3 kv RMS 3 kv RMS 110 V AC/DC 55... 130 V AC/DC 220 V AC/DC 150... 260 V AC/DC Input resistance approx. 70 kω approx. 200 kω Other voltages can also be supplied on demand. Power consumption Response delay Horn sounding duration with automatic acknowledgement Load capacity of relay contacts minimum maximum LED flashing frequency Flashing Slow flashing Insulation voltage Reporting and function inputs against all other voltages Functional inputs 1... 3 against 4.. 6 Relay contacts against all other voltages against each other typically 1 2 W; short-time max. 4 W 5 ms... approx. 1 min; standard setting 100 ms* 1... 255 s; standard setting 10 s 1.2 V or 1 ma ( > 50 mw) 250 V AC / 1 A (2 A with pure ohmic load) 30 V DC / 2 A 110 V DC / 0.2 A 220 V DC / 0.1 A 1 Hz 0,5 Hz 4 kv RMS 2.5 kv RMS 4 kv RMS 500 V Potential difference between the neutral conductor of the reporting groups Signal input 1... 5 and 6... 10 50 V Mechanical data Front frame Front panel aperture Mounting position Weight 96 x 96 mm; maximum installation depth 125 mm 91 x 91 +0,5 mm arbitrary approx. 0.52 kg Environmental conditions Operating and ambient temperature -20 C +60 C without condensation (supply voltage < 110 V) -10 C +60 C without condensation (supply voltage >= 110 V) Storage temperature -20 C... +70 C without condensation * With alternating current (AC) the response delay in the lower signal voltage range can be increased in dependency of the signal form. Page 5 of 8

FSm 10 drop-flap fault annunciator Protection class at the front IP 54; IP 65 with transparent protective cover Protection class at the rear IP 20 Connection terminals pluggable Cross-section rigid or flexible without wire sleeves 0,2... 2,5 mm 2 with wire sleeves 0,25... 2,5 mm 2 Permissible relative humidity = 75% on average over the year (group F DIN 40040) Noise immunity EMC tested according to EN 61000-4-2,4,5 The information given for alternating voltages are refering to a sinusoidal alternating voltage with a frequency of 50/60 Hz and all information on an ambient temperature of 25 C, otherwise noted. Terminal assignments Page 6 of 8

an annunciator from the MSM product family Dimensional drawing Dimensions in mm Subject to technical changes without prior notice Ordering codes Standard devices Article No Type Supply and signalling voltage 58FSM1000000 FSM 10-0/12AD/12AD/12AD/0 12 V AC/DC 58FSM1001110 FSM 10-0/24AD/24AD/24AD/0 24 V AC/DC 58FSM100E330 FSM 10-0/60DC/60AD/60AD/0 48 V AC/DC and 60 V DC 58FSM1004440 FSM 10-0/110AD/110AD/110AD/0 110 V AC/DC 58FSM1005550 FSM 10-0/220AD/220AD/220AD/0 220 V AC/DC Accessories Article No Type Specification 58ZPK2P/PC Parameterisation cable for MSM-family Cable length 1.5 m KSH1 Transparent protection cover IP 65 AN64 DCF77-Active antenna Cable length 2.5 m K104-1 CAN-Bus connecting cable (FSM 10 - FSM 10), length 20 cm K104-3 CAN-Bus connecting cable (FSM 10 - FSM 10), length 50 cm Page of 8

FSm 10 drop-flap fault annunciator Do you need alternative fault annunciators or operation indicators? LED - indication modules Compact module in a 96 x 96 mm housing for panel mounting 8 or 16 channels with exchangeable LED s Several alarm voltages in a range from 24 V up to 230 V Integrated lamp test push button Collective report optional Front panel marking: transparent window for slide-in labels Low built-in depth BSM - Panel mounting basic fault annunciators Devices with 8, 16, 32 and 48 Signal inputs Sealed front, protection class IP 54 Integrated buttons, functional inputs and relay outputs Self monitoring Optional DIN rail modules for PCS contacts Optional Software-Parameterisation via PC Realisation of all common alarm sequences Extremly bright LED with great reading angle and in many colours U7 - series 19"- signalling system Alarm processing in larger intercommunication systems Modular 19 system can be extended to over 1000 alarms Supply voltage and alarm voltage 24 220 V Potential separation of all circuits LED-display per alarm Marker strip connectable to transparent window Integrated test and acknowledgement push-button Subrack with prewired, ready-to-connect rear PC-board All international alarm sequences optional Contact Elektra Elektronik GmbH & Co Störcontroller KG Hummelbühl 7-9 71522 Backnang Germany Tel. +49 (0) 7191.182-0 Fax. +49 (0) 7191.182-200 info@ees-online.de www.ees-online.de