Two-Step Capacity Modulation of a Single Cylinder Compressor

Similar documents
Compressor Capacity Control: A New Direction

Performance Evaluation of the Energy Efficiency of Crank-Driven Compressor and Linear Compressor for a Household Refrigerator

The Innovative Green Technology for Refrigerators Development of Innovative Linear Compressor

Higher Efficiency, Lower Sound, and Lower Cost Air Conditioning Compressors: Part 1 Efficiency

Application Considerations of Line-Break, Internal Protectors

Conceptual Design of a Better Heat Pump Compressor for Northern Climates

Development of an Open Drive Scroll Compressor for Transportation Refrigeration

Analysis of Oil Pumping in the Hermetic Reciprocating Compressor for Household Refrigerators

Performance Characteristics of Air-Conditioner Under Tropical Ambient Condition

Sub-Critical Operation of the CO2 Expander/ Compressor

Performance of R-22, R-407C and R-410A at Constant Cooling Capacity in a 10

Drop-in Testing of Next-Generation R134a Alternates in a Commercial Bottle Cooler/Freezer

Development of a Novel Structure Rotary Compressor for Separate Sensible and Latent Cooling Air-Conditioning System

The Development Of High Efficiency Air Conditioner With Two Compressors Of Different Capacities

Performance Characteristics of a Refrigerator- Freezer with Parallel Evaporators using a Linear Compressor

Heat Transfer of R-22 and Alternatives in a Plate- Type Evaporator

Comparison Of Hermetic Scroll And Reciprocating Compressors Operating Under Varying Refrigerant Charge And Load

System Using Exhaust Heat from Residential GHPs

Effect of Modification in Refrigerant Passage of an Automotive Air Conditioning Compressor

Development and Performance Measurements of a Small Compressor for Transcritical CO2 Applications

Operating Functions Temperature Parameters

Purdue e-pubs. Purdue University

Introduction of Transcritical Refrigeration Cycle Utilizing CO2 as Working Fluid

Lower GWP Refrigerants Compared to R404A for Economizer Style Compressors

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

Low GWP Refrigerants for Air Conditioning Applications

Development Of 2-Cylinder Rotary Compressor Series For Light Commercial Use With R410A

Comparison of the High Side vs

Modelling of an Integrated Supermarket Refrigeration and Heating System Using Natural Refrigerants

Experimental Investigation on Condensation Performance of Fin-and-Flat-Tube Heat Exchanger

Experimental Analysis of a Stirling Refrigerator Employing Jet-Impingement Heat Exchanger and Nanofluids

Load Sharing Strategies in Multiple Compressor Refrigeration Systems

Low Global Warming Refrigerants For Commercial Refrigeration Systems

High Efficiency R-134a Compressor for Domestic Refrigerator

Compressor Capacity Control

The Effect of the Ventilation and the Control Mode on the Performance of a VRV System in Cooling and Heating Modes

An Investigation Into The Influence Of Improved Refrigeration Cycle And Refrigerants On An Energy Efficient Domestic Refrigerator

Investigation, Analysis and Solution of Higher Noise of Heat Pump Water Heater

Development of Large Refrigerant Compressors

Effects of Frost Formation on the External Heat Transfer Coefficient of a Counter-Crossflow Display Case Air Coil

A Study on Compression Characteristic of Wet Vapor Refrigerant

Energy Savings Potential of Passive Chilled Beam System as a Retrofit Option for Commercial Buildings in Different Climates

Design and Research of the Digital VRV Multi- Connected Units With Three Pipes Type Heat Recovery System

Fifteen Years of Dehumidification Results from Heat Pump Water Heaters

Experimental Study on the Performance and Oil Return Characteristics of Multi-Split Air- Conditioning System for Medium Size Building

Geothermal ORC Systems Using Large Screw Expanders

Refrigeration Cycle And Compressor Performance For Various Low GWP Refrigerants

AHRI Low Global Warming Potential Alternative Refrigerants Evaluation Program (Low-GWP AREP) â Summary of Phase II Testing Results

Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to Achieve Optimal Closed DOAS Operation

Development of R744 Two Stage Compressor for Commercial Heat Pump Water Heater

Comparison of Energy Efficiencies of Commercial Refrigeration Direct and Indirect Systems

The Design Of A New Generation Of Twin Screw Refrigeration Compressors

AHRI Low Global Warming Potential Alternative Refrigerants Evaluation Program (Low-GWP AREP) Summary of Phase I Testing Results

Hunting Phenomena Of Automotive Air Conditioning Systems With Variable Displacement Compressor

Systematic Study of the Solution Properties of Low Global Warming Potential R-404A Replacement Refrigerant Blends with Various Polyol Ester Lubricants

Performance Investigation of Refrigerant Vapor- Injection Technique for Residential Heat Pump Systems

BASIC HEAT PUMP THEORY By: Lloyd A. Mullen By: Lloyd G. Williams Service Department, York Division, Borg-Warner Corporation

Experimental Study of Fouling Performance of Air Conditioning System with Microchannel Heat Exchanger

Noise Reduction Technology With Porous Metal for Refrigerant Two-Phase Flow Through the Expansion Valve

Performance Comparison of R32, R410A and R290 Refrigerant in Inverter Heat Pumps Application

Improving Heating Performance of a MPS Heat Pump System With Consideration of Compressor Heating Effects in Heat Exchanger Design

OPERATION INSTRUCTIONS DEMAND DEFROST CONTROL BOARD MODEL FOR USE WITH MODELS: AFFINITY, ECHELON, ACCLIMATE HEAT PUMP SERIES

Design and Research of the Commercial Digital VRV Multi-Connected Units With Sub-Cooled Ice Storage System

Some Modeling Improvements for Unitary Air Conditioners and Heat Pumps at Off-Design Conditions

Building Multi Air Conditioner with Higher Efficiency and Fault Detection Function

Study of R161 Refrigerant for Residential Airconditioning

Heat Exchanger Shelves For Better Temperature Control Of Food In Open-Type Display Cases

Efficiency of Non-Azeotropic Refrigerant Cycle

Experimental Study on the Thermal Behavior of a Domestic Refrigeration Compressor during Transient Operation in a Small Capacity Cooling System

Electrical Problems. Fuse(s) blow or circuit breaker trips. Does the unit use circuit breakers or fuses? Replace with correct fuse(s)

Diagnosing Troubles in Refrigeration Units with Screw Compressors

Twenty Years of Compressor Innovation at NTU, Singapore

Energy Transfer Based Test Method Development and Evaluation of Horizontal Air Flow Re- Circulatory Air Curtain Efficiencies

Chapter-8 Capacity Control of Refrigeration Systems

Experimental Investigation of a New High Temperature Heat Pump Using Water as Refrigerant for Industrial Heat Recovery

Numerical Evaluation of Performance Curves of a High Frequency Microcompressor

A study of high efficiency CO2 refrigerant VRF air conditioning system adopting multi-stage compression cycle

Isobutane as a Refrigerator Freezer Refrigerant

SECTION 8 AIR SOURCE HEAT PUMPS UNIT 43 AIR SOURCE HEAT PUMPS

Development of HFC-134a Compressor for Domestic Refrigerator

Performance Comparisons Of A Unitary Split System Using Microchannel and Fin-Tube Outdoor Coils, Part I: Cooling Tests

Visualization of Evaporatively Cooled Heat Exchanger Wetted Fin Area

Experimental Study About An Amount Of Oil Charge On Electric Driven Scroll Compressor For Electric Vehicle

Effects of Oil on atranscritical Carbon Dioxide Air Conditioning Systems some experiences -

Using Adaptive Defrost Control Technology to Improve Energy Savings in the Food Service Industry.

An Experimental Investigation Of Oil Retention Characteristics In CO2 Air-Conditioning Systems

Performance Characteristics and Optimization of a Dual-Loop Cycle for a Domestic Refrigerator- Freezer

A Performance-Enhancing Additive for Vapor- Compression Heat Pumps: Additional Test Results

Development of a Transient Simulation Model of a Freezer Part II: Comparison of Experimental Data with Model

An Analysis of a New Type Refrigeration Cycle (MICLOSS)

Design of Divided Condensers for Desiccant Wheel-Assisted Separate Sensible and Latent Cooling AC Systems

Experimental Research On Gas Injection High Temperature Heat Pump With An Economizer

R32 Compressor for Air conditioning and Refrigeration applications in China

Development of Performance Test Facility of Positive Displacement CO2 Refrigerant Compressor

Design of Compressors to Meet the Performance Ranges Required for Residential Air Conditioning

Effect of the Use Pattern on Performance of Heat Pump Water Heater

LOW PROFILE UNIT COOLER

APPLICATION GUIDELINES FOR COPELAND COMPLIANT SCROLL COMPRESSORS (ZR*1 Models)

The Development of the Energy-Saving Technology by the Composition Control of R407C

WIRING DIAGRAMS R410A MODELS PAC 2OAC/2OACH CAC OWC PWC

Transcription:

Purdue University Purdue e-pubs nternational Compressor Engineering Conference School of Mechanical Engineering 2000 Two-Step Capacity Modulation of a Single Cylinder Compressor T. Goodnight Bristol Compressors D. Monk Bristol Compressors J. Loprete Bristol Compressors Follow this and additional works at: http://docs.lib.purdue.edu/icec Goodnight, T.; Monk, D.; and Loprete, J., "Two-Step Capacity Modulation of a Single Cylinder Compressor" (2000). nternational Compressor Engineering Conference. Paper 1389. http://docs.lib.purdue.edu/icec/1389 This document has been made available through Purdue e-pubs, a service of the Purdue University Libraries. Please contact epubs@purdue.edu for additional information. Complete proceedings may be acquired in print and on CD-ROM directly from the Ray W. Herrick Laboratories at https://engineering.purdue.edu/ Herrick/Events/orderlit.html

TWO-STEP CAPACTY MODULATON OF A SNGLE CYLNDER COMPRESSOR Prepared for: 2000 nternational Compressor Engineering Conference at Purdue By: Tom Goodnight Dave Monk Joe Loprete Bristol Compressors, nc. 15185 ndustrial Park Road Bristol, VA 24202 Phone: (540) 645-5942 Fax: (540) 645-7561 Email: tom.goodnight@bristolcompressors.com 5 April, 2000 Fifteenth nternational Compressor Engineering Conference at Purdue University, West Lafayette, N, USA- July 25-28, 2000 221

Abstract: Energy efficiency will become an increasing concern in the next decade, and disproportionately so for small, single cylinder compressors because of their widespread use in consumer products. An effective way to dramatically improve system efficiency is through the use of capacity modulation. Through the use of a special mechanism, a single-cylinder reciprocating compressor can provide twostep capacity modulation for little added cost. Many of the benefits of fully-variable capacity can be achieved with two-step modulation: improved system efficiency, decreased cycling and improved temperature control. This can be done in a cost-effective manner and can be easily adapted to existing appliances. Fifteenth nternational Compressor Engineering Conference at Purdue University, West Lafayette, N, USA- July 25-28, 2000 222

NTRODUCTON Single cylinder compressors are used in a wide array of refrigeration equipment. They can be found in such commercial appliances as water coolers, water fountains, vending machines and ice machines as well as consumer products like refrigerators, freezers and air conditioners. There are several forces that are driving these compressors to become more efficient. The EPA regulated phase-out of ozone-depleting chemicals means that both the working fluids of refrigeration systems ( 1996) and the insulation of cabinets (2003) are changing, usually to less effective alternatives. n addition, the energy efficiency standard for refrigerators is being raised (200 1 ). Coupled with these monumental changes are the facts that many refrigeration products sell today for a price similar to that of twenty or thirty years ago, and that consumers are demanding more technology and features for a very small increase in price. There are several ways to attack this multi-faceted problem of efficiency, cost, consumer features and environmental impact. Research is underway to develop working fluids that are more efficient and less detrimental to the environment. Replacement blowing agents for phased-out chemicals are being investigated to improve cabinet insulation performance. Cabinets can incorporate more insulation resulting in thicker walls and decreased interior volume. Electronic controls can be used to better control efficiency, cooling and to provide consumer features such as faster cooling and ice making. Capacity modulation can also provide improved efficiency and consumer features for varying amounts of increased cost. Capacity modulation can be achieved by several techniques. Hot-gas bypass, compressor speed modulation, multiple compressor configurations, variable displacement compressors, variable expansion devices and fan speed modulation are commonly used techniques. Two-step capacity modulation of an individual compressor is a new technology that can be employed to great benefit for minimal applied cost. Two-step capacity modulation in a single-cylinder compressor can be achieved through the use of an additional component in a standard reciprocating compressor. This modulating compressor contains a crankshaft, an eccentric bushing (throwblock) and a connecting rod as shown in Figure 1 below. t is this throwblock that controls the capacity modulation of the compressor. Two-Step Mechanism Parts Two-Step Assembly Throw block Connecting Rod Figure 1 Fifteenth nternational Compressor Engineering Conference at Purdue University, West Lafayette, N, USA- July 25-28, 2000 223

OPERATON OF THE TWO-STEP MECHANSM The two steps of capacity modulation are achieved through control of the piston stroke, or the swept volume. n full capacity mode the piston sweeps the entire cylinder volume from Top Dead Center (TDC) to Bottom Dead Center (BDC). n partial capacity mode the piston sweeps only a portion of the cylinder volume from TDC to some preset intermediate point. The stroke of the piston is controlled by the throwblock. The throwblock controls the stroke of the piston by attaching to either the crankshaft or the connecting rod. When the throwblock is attached to the crankshaft, it rotates with the crankshaft and the piston stroke equals the eccentricity of the crankshaft plus the eccentricity of the throwblock. This is the full capacity mode. When the throwblock is fixed to the connecting rod, the piston stroke equals only the eccentricity of the crankshaft, as in a standard compressor. This is the partial capacity mode. n both modes, the throwblock is fixed such that the piston comes to Top Dead Center (TDC) of the cylinder. The motion of the throwblock in each mode is illustrated in Figures 2 and 3 below. Full Capacity Mechanism Operation Partial Capacity Mechanism Operation Figure 2 Partial Stroke Crank Circle Figure 3 Full Stroke Fifteenth nternational Compressor Engineering Conference at Purdue University, West Lafayette, N, USA- July 25-28, 2000 224

CONTROL OF THE TWO-STEP MECHANSM One way to control the attaclnnent of the throwblock to either the crankshaft (full capacity mode) or the connecting rod (partial capacity mode) is based on the direction of rotation of the mechanical. When the compressor spins in one direction, the throwblock attaches to the crankshaft for full capacity operation. When the mechanical spins in the other direction, the throwblock releases the crankshaft and attaches to the connecting rod for partial capacity operation. Thus, capacity can be controlled by reversing the direction of motor rotation. Unmodulated single cylinder compressors generally use either an induction run or a permanent split capacitor (PSC) type of motor. The main winding is matched to the operating point of the compressor to provide maximum efficiency. When the operating point, or load, of the compressor changes, the efficiency of the motor falls dramatically. Thus, if the capacity of the compressor mechanical is reduced, the efficiency of the motor decreases from point A to point B as illustrated in Figure 4 below. MOTOR EFFCENCY VS TORQUE A ~...-- "!::.... ~ 0 -> 0 z w 0 u: LL w ~ 0 1-0 ::!! FULL STROKE OPERATON PARTAL STROKE OPERATON --MAN WNDNG -AUXLARY WNDNG MOTOR TORQUE Figure 4 Fortunately, these motors have both a main winding and an auxiliary winding. By reversing these windings in the circuit, the direction of the PSC motor rotation can be reversed- that is, the main winding becomes the auxiliary winding, and vice versa. This is generally not possible with an induction run motor because the auxiliary winding is too small. By operating the compressor mechanical in full capacity in one direction of rotation, and partial capacity in the other direction, the efficiency of the windings can be optimized for two load points, shown as points A and C in Figure 4 above. Using the terms "run" and "start" windings, for the full capacity direction of rotation, the main winding is the "run" winding while the auxiliary winding is the "start" winding. For the partial capacity direction, the auxiliary winding is the "run" winding and the main winding is the "start" winding. Thus, the main winding is optimized for the full-capacity load point A and the auxiliary winding is optimized for the partial capacity load point C. The cost implications of matching a PSC motor to two load points are very small, and in some cases no changes are necessary at all. Also, PSC motors are only slightly more expensive than induction run motors. Fifteenth nternational Compressor Engineering Conference at Purdue University, West Lafayette, N, USA- July 25-28, 2000 225

MPLEMENTATON OF A TWO-STEP COMPRESSOR There are relatively few component changes necessary to implement a two-step modulation capability. The compressor mechanical requires the addition of the throwblock. The compressor electrical requires minimal changes to the motor to optimize part-load efficiency and allow the motor to reverse. This compressor can be installed as a drop-in replacement with no system changes, or improvements can be made to the system coils, expansion device and controls to optimize part-load operation. Some possible control schemes using various levels of system integration are illustrated in Figures 5, 6 and 7. The first represents a "drop-in" replacement, the second illustrates a mechanical type of control system using bimetal thermostats and the third demonstrates an electronic solution wherein the compressor is mated tightly to the system controls. Figure 5 below shows the use of a two-step compressor in the place of a standard compressor requiring no modifications to the existing system. The compressor has a timer mounted to it, and the electrical connections are the same as they would be for a non-modulating compressor. The system thermostat behaves the same way as before, and the compressor mode is based on run time. When the system thermostat first closes, the compressor starts in partial capacity mode. f the system demand has not been satisfied after a certain length of time, the timer stops the compressor, allows a time delay for pressure equalization, and restarts the compressor in full capacity mode. The compressor runs until the thermostat opens. This cycle is then repeated. TMER CONTROL SCHEME Standard adjustable t-stat (bi-metal) ------..._ r-~-=-----, L2 (R) Ll (C) Run Capacitor Compressor Terminals Figure 5 Fifteenth nternational Compressor Engineering Conference at Purdue University, West Lafayette, N, USA- July 25-28, 2000 226

Figure 6 below illustrates a control scheme using a mechanical double-throw thermostat that controls compressor capacity used in conjunction with a standard mechanical thermostat to control cabinet temperature. When the cabinet is hot, both thermostats are closed and the compressor starts in full capacity mode. As the cabinet cools, the double throw thermostat switches the start and run windings, and the compressor runs in partial capacity mode until the cabinet temperature drops below the standard thermostat level. The compressor cycles at partial capacity unless it cannot satisfy the demand, in which case the cabinet temperature rises and the double throw thermostat switches the compressor to full capacity mode. A time delay must be included to prevent the compressor from starting against a pressure differential and also to allow motor rotation to stop, and there must be some hysteresis built into the double-throw thermostat to prevent the cabinet from warming above the partial capacity point during this delay. PRESET THERMOSTAT CONTROL SCHEME Standard adjustable t-stat (bi-metal) ------, ---::.-----. Preset at cabinet maximum allowable temp double throw bi-metal t-stat (normally closed in high cap. mode) ~ L2(R) - Ll(C) Time delay (to allow motor rotation to stop, and any pressure equalization necessary) Run Capacitor Compressor Terminals Figure 6 Figure 7 below shows an electronic thermostat that controls both compressor capacity and cabinet temperature. The temperature set points for the two capacity modes, the time delay and other features such as defrost algorithms and interrupt buttons for "sleep" or "ice making" features are all integrated into one controller. ELECTRONC CONTROL SCHEME L2 (R) -----------1 activate stages, delay timer built into Thermostat with delta temp. to algorithm Ll(C) Run Capacitor Compressor Terminals Figure 7 Fifteenth nternational Compressor Engineering Conference at Purdue University, West Lafayette, N, USA- July 25-28, 2000 227

BENEFTS OF A TWO-STEP COMPRESSOR Because standard compressors are sized for the highest loads a system will see, they provide too much capacity most of the time. This results in frequent cycling which is stressful to the system components. A two-step modulating compressor will allow the system to operate for a longer period of time at a reduced power level during steady-state operation while still providing the capacity to cool the system during times of higher loading. This permits less cycling and results in better reliability, better temperature control and less perceived noise.. The benefits to the system efficiency of two-step capacity modulation depend on the initial system efficiency and the amount of modifications that are made to the system. Testing with variable speed compressors shows that improvements in system efficiency range from 0% to 15% simply by installing a variable-speed compressor in place of a standard compressor. By tailoring the system coils, fans, thermostats and algorithms to a variable capacity compressor, improvements of up to 40% may be possible. A manufacturing benefit of a two-step modulated compressor is deproliferation. By using such a modulating compressor in conjunction with various degrees of system and controls modification, a manufacturer can offer models of different efficiencies based on one chassis. For example, a low-end model might use a standard compressor, a mid-range model would use a two-step compressor with minimal system modifications, and a high-end model would use a two-step compressor with a control scheme and system components tailored to part-load operation. n this way many different models can be offered that use a similar cabinet and compenents. Two-step modulation also provides the possibility of sales tools in terms of customer features. A high efficiency refrigerator that has a "Make ce" button that changes the compressor mode to full capacity for a fast pull-down or to freeze water quickly provides tangible benefits to a homeowner. Alternatively, some commercial customers may be interested in a "Sleep" feature that keeps a vending machine in low-capacity mode during off-peak hours. Two-step modulation can add value to a product above and beyond reduced power consumption. CONCLUSONS Two-step capacity modulation of a single cylinder compressor can be used to improve system efficiency through decreased power consumption, improve system reliability through decreased cycling and improve temperature control through longer run times. t can allow a manufacturer to offer new commercial and consumer features. Two-step capacity modulation can also reduce manufacturing proliferation by allowing several products of different efficiency levels to be built using the same chassis and slightly different. control schemes. This can be done in a cost-effective manner and can be easily adapted to existing appliances. Fifteenth nternational Compressor Engineering Conference at Purdue University, West Lafayette, N, USA- July 25-28, 2000 228