Fire Safety Products Conventional Detection Audible/Visible Notification HVAC Systems Monitoring Sprinkler Systems Monitoring

Similar documents
advancedsolutions Advanced Design. We have engineered all SpectrAlert products to meet or exceed code today and tomorrow. We ve worked to standardize

Fire Safety Products. Conventional Detection Audible/Visible Notification HVAC Systems Monitoring Sprinkler Systems Monitoring

Full Line Catalog and Product Brochures

Manual Call Point-Installation efficiency, Flexibility and full compliance with latest standards are at the heart of new Indoor Call Point range.

Fire Safety Product Catalog

Fire & Life Safety Products CATALOG

Bid Specifications. Fire Alarm Equipment and Parts. USA Bid No

Reshaping Duct Smoke Detection

Fire Sprinkler Monitoring Products. Solutions and Service for Sprinkler System Integrity

Reshaping Duct Smoke Detection

MEA. SpectrAlert Series Horns, Strobes, and Horn/Strobes GENERAL

The Advance You ve Been Looking For

SpectrAlert Advance. Field-Selectable Mass Notification Devices. Description. An ISO Company SIGNALING. MEA Approved E

Agent Release Control Panel

Selectable Output Chimes and Chime/Strobes

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information)

ELECTRONIC SOUNDER STROBE Model : AVD-C407

SECTION FIRE ALARM SYSTEMS

Vista-20SEUL System Design Sheet

L-Series, Emergency Communication Devices

good things in small packages

Vista-50P/-50PUL System Design Sheet

Addressable Detectors & Bases

Vista-128FB System Design Sheet

AL600ULX Series. Power Supply/Charger. Installation Guide

Carbon Monoxide (CO) Detection PRODUCTS. Accessories Conventional Detectors

AL1002ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

- Four (4) Fused Outputs - Four (4) PTC Outputs. - Eight (8) Fused Outputs - Eight (8) PTC Outputs

L-Series, Indoor Strobes and Horn Strobes

DH100ACDCI Ionization Air Duct Smoke Detector

L-Series, Indoor Strobes and Horn Strobes

AL1042ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

- Four (4) Fused Outputs - Four (4) PTC Outputs. - Eight (8) Fused Outputs - Eight (8) PTC Outputs

WFDE Series Waterflow Detector

Analog fire panels FPA-1000 Family

AL1042ULADA. NAC Power Extender. Installation Guide (See Application Guide for additional information) Rev

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

TrueAlert Notification Appliances

TRN100BPT, TRN100BP, and TRN100BPC Air Duct Smoke Detector with Extended Air Speed Range

TrueAlarm Analog Sensing

DH100ACDCI Ionization Air Duct Smoke Detector

AND ARCHITECT SPECIFICATIONS

TrueAlarm ES Analog Sensing

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Addressable Fire Alarm Control Panel

SIRENS PROGRAMMABLE MULTI-SOUND SIGNAL by Tomar Electronics

DH100ACDCLP Air Duct Smoke Detector with Extended Air Speed Range

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

TECHNICAL DATA OBSOLETE

Control / Communicator

LifeAlarm Fire Alarm Controls

- 4 12VDC or 24VDC VDC or 24VDC - Eight (8) Fused Outputs - Eight (8) PTC Outputs. Installing Company: Service Rep.

Genesis Low Frequency (520 Hz) Horn-Strobe Installation Sheet

Signature Series Auto-Sync Output Module (CC1S)

Vista-10SE System Design Sheet

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

SELECT-A-HORN/STROBE SERIES

LifeAlarm Fire Alarm Control Panels

Multi-Point Peripherals

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

INSTALLATION AND MAINTENANCE

July 14, 1999 DF C-100.

Potter Wall Mount Select-A-Strobe

XP6-C. Six Circuit Supervised Control Module and SYNC-1 Accessory Card

TrueAlert Addressable Notification Appliances

TrueAlarm Analog Sensing

D350RPL INTELLIGENT PHOTOELECTRONIC DUCT SMOKE DETECTOR WITH EXTENDED AIR SPEED RANGE INSTALLATION AND MAINTENANCE INSTRUCTIONS

Multi-Point Peripherals

TrueAlert Non-Addressable, Multi-Candela Notification Appliances Installation Instructions

CSH24CH. Colored Light Strobe/Horn Series High Candela. Description. Features. Ceiling/Wall Mount Patent Pending. Ordering Information

Xenex Conventional Fire Detection & Alarm System

M O D E L S F I R E G A R D M C V ADVANCE FIRE CONTROL RELEASE DEVICE

CO/Smoke Detection PRODUCTS. Accessories Conventional Detectors and Modules

Multiple Input and Output Modules

Specification/ Data Sheet

Firelite CONVENTIONAL FIRE ALARM CONTROL PANELS CONVENTIONAL PANEL W/ BUILT-IN DIGITAL ALARM COMMUNICATOR

Life safety notification

Conventional Fire Detection

SAFEPATH Mass Notification System (SPMNS)

The complete conventional fire warning system

Addressable and Conventional Fire Protection

Intelligent addressable fire alarm control panel

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5

DH500ACDC Intelligent Air Duct Smoke Detector Housing

SP40S-D. Kingfisher Company, inc. Features: Description:

WORLD CLASS SOLUTIONS TO A UNIVERSAL CHALLENGE EST LIFE SAFETY PRODUCTS DETECTORS AND MODULES ... EDWARDS SYSTEMS TECHNOLOGY

16721 FIRE ALARM AND DETECTION SYSTEMS

DH100ACDCLPX Air Duct Smoke Detector with Extended Air Speed Range

!+ NCA-2-TC Network Control Annunciator-2, 640-characters-Traditional Chinese Network Control Annunciator-2, Traditional Chinese $1,587.

16721 FIRE ALARM AND DETECTION SYSTEMS

AND ARCHITECT SPECIFICATIONS

WINDOW & HVAC REPLACEMENT PEMBERTON TOWNSHIP BOE REGAN YOUNG ENGLAND BUTERA, PC PROJECT #5450E

SAFEPATH SAFEPATH. Emergency communications system

SECTION FIRE ALARM, DETECTION AND NOTIFICATION SYSTEM

Unified Fire Authority - Fire Prevention Bureau

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

DETECTOR TEST LOG. Detector Identification Information DHX-501 INTELLIGENT AIR DUCT SMOKE DETECTOR HOUSING INSTALLATION AND MAINTENANCE INSTRUCTIONS

Inspector: PROPERTY INFORMATION Photo Smoke Detector Notification Control Panel Stand Alone Smoke Detector Dialer SUMMARY ONLY

USAutomatic Sprinkler Corporation

Transcription:

F U L L - L I N E P R O D U C T G U I D E Fire Safety Products Conventional Detection Audible/Visible Notification HVAC Systems Monitoring Sprinkler Systems Monitoring

At System Sensor, innovation is more than an ideal; innovation is our way of life. Every day we design new products that are convenient to install and efficient to operate, providing our customers with the highest level of reliability. In other words, we make it our business to develop advanced ideas that deliver advanced solutions. This product guide is divided into four areas: Conventional Detection a complete line of smoke detectors led by the innovative i 3 Series. Audible/Visible Notification the SpectrAlert line, featuring the Selectable Output Series of multiple-candela units. HVAC Systems Monitoring the Innovair line and other specialty detectors designed to detect smoke in the air duct network. Sprinkler Systems Monitoring products designed to sense the flow of water through pipes, switches and valves. C o n v e n t i o n a l D e t e c t i o n i 3 Series Photoelectric Smoke Detectors Installation ease, intelligence and instant inspection are the guiding principles of System Sensor s i 3 Series photoelectric smoke detectors. The i 3 Series is a complete line Standard, Sounder, Auxiliary Form C Relay and Isolated Thermal models featuring plug-in bases, removable covers, remote maintenance signaling, drift compensation and smoothing algorithms, green and red LEDs, and simplified sensitivity measurement. Loop Type Thermal Sounder Form C Relay Avg. Standby Current Max. Alarm Current 2W-B 2-wire No No No 8.5-35 VDC 50 µa 130 ma limited by control panel 2WT-B 2-wire Yes No No 8.5-35 VDC 50 µa 130 ma limited by control panel 4W-B 4-wire No No No 8.5-35 VDC 50 µa 23 ma 4WT-B 4-wire Yes No No 8.5-35 VDC 50 µa 23 ma 2WTA-B 2-wire Yes Yes No 8.5-35 VDC 50 µa 130 ma* 2WTR-B 2-wire Yes No Yes 8.5-35 VDC 50 µa 130 ma limited by control panel 4WTA-B 4-wire Yes Yes No 10-35 VDC 50 µa 35 ma 4WTR-B 4-wire Yes No Yes 10-35 VDC 50 µa 35 ma 4WTAR-B 4-wire Yes Yes Yes 10-35 VDC 50 µa 50 ma 4WITAR-B 4-wire Isolated Yes Yes 10-35 VDC 50 µa 50 ma * In direct power (non-reverse polarity), the maximum alarm current is 130 ma limited by the panel. In reverse polarity power, the maximum current is 30 ma for the 2WTA-B in alarm; 12 ma for all other 2WTA-B units on the loop. Add 25 ma for the RRS-MOD reversing relay alarm current. 100 Series Plug-in Smoke Detectors The 100 Series low profile plug-in smoke detectors are ideal for light commercial applications. Offered with a photoelectric sensor, the 100 Series may be installed with a range of plug-in bases to accommodate a variety of wiring configurations and voltages. Detection Type Wiring Thermal Avg. Standby Current Max. Alarm Current 2151 Photoelectric Mounting base dependent No See bases 85 µa Mounting base dependent 1

400 Series Direct-Wire and Plug-in Smoke Detectors The 400 Series represents a family of conventional smoke and electronic heat detectors in a variety of configurations. Direct-wire models, used with two- or four-wire loops, are available with an ionization sensor. A plug-in ionization model is also available. Detection Type Wiring Thermal Max. Standby Current Max. Alarm Current 1400 Ionization 2-wire No 12/24 VDC 120 µa Limited by the control panel 1412B Ionization 4-wire No 12 VDC 120 µa 77 ma 1424 Ionization 4-wire No 24 VDC 120 µa 41 ma 1451 Ionization Mounting base dependent No See bases 120 µa Mounting base dependent 400 Series Plug-in Electronic Heat Detectors The 400 Series plug-in electronic heat detectors offer thermal detection in both 190 F fixed temperature and 135 F combination fixed/rate-of-rise configurations. Both models may be installed with a range of 400 Series plug-in bases. Temperature Rating Activation Method Max. Standby Current 5451 135 Fixed/Rate-of-rise 100 µa 4451HT 190 Fixed temperature 100 µa 100 Series Plug-in Smoke Detector Bases Designed for use with System Sensor s 100 Series plug-in smoke detectors, the 100 Series bases accommodate 2- or 4-wire loops and 12, 24 or 120 operating voltages to address a broad range of applications. Loop Type Alarm Current B110LP 2-wire 12/24 VDC 10-100 ma limited by the control panel B110RLP 2-wire 24 VDC 22-62 ma B112LP 4-wire 24 VDC 14-39 ma B114LP 4-wire 120 VAC 75 ma (AC) maximum B116LP 2-wire 24 VDC 12-100 ma limited by the control panel 400 Series Plug-in Smoke Detector Bases Designed for use with System Sensor s 400 Series plug-in smoke detectors, the 400 Series bases are offered in a variety of models for 2- or 4-wire loops and 12, 24 or 120 operating voltages. Loop Type Alarm Contact Type Max. Alarm Current B401 2-wire 12/24 VDC 10-100 ma limited by the control panel B401B 2-wire 12/24 VDC 10-100 ma limited by the control panel B401BR 2-wire 24 VDC 10-62 ma B402B 4-wire Form A & C 24 VDC 14-39 ma B404B 4-wire Form A & C + A supervisory 120 VAC 75 ma (AC) maximum B406B 2-wire Form C 24 VDC 12-100 ma limited by the control panel 2

5600 Series Mechanical Heat Detectors The 5600 Series mechanical heat detectors offer a low cost means for property protection against fire and for non life-safety installations where smoke detectors are inappropriate. To accommodate a broad range of applications, the 5600 Series is available in a full line of configurations. Single- and dual-circuit models are available with low or high temperature ratings and with fixed temperature or combination fixed temperature/rate-of-rise (ROR) activation. Circuit Identification Method on Exterior Temperature Rating Activation Method Protected Spacing** 5601P Single Non-lettered 135 Fixed/Rate-of-rise 50 feet by 50 feet 5602 Single Lettering 194 Fixed/Rate-of-rise 50 feet by 50 feet 5603 Single Lettering 135 Fixed temperature 25 feet by 25 feet 5604 Single Lettering 194 Fixed temperature 25 feet by 25 feet 5621 Dual Lettering 135 Fixed/Rate-of-rise 50 feet by 50 feet 5622 Dual Lettering 194 Fixed/Rate-of-rise 50 feet by 50 feet 5623 Dual Lettering 135 Fixed temperature 25 feet by 25 feet 5624 Dual Lettering 194 Fixed temperature 25 feet by 25 feet **Refer to NFPA72 guidelines for spacing reductions when ceiling heights exceed 10 feet. Reflected Beam Smoke Detector The reflected beam smoke detectors incorporate an eight inch reflector for simple installation and alignment. The BEAM 1224S includes an integral sensitivity test feature. Wiring Avg. Standby Current Avg. Alarm Current Range BEAM1224 4-wire 10.2-32 VDC 17 ma max. @ 24 VDC 38.5 ma max. @ 24 VDC 16-328 ft. (5m to 100m) BEAM1224S 4-wire 15-32 VDC 17 ma max. @ 24 VDC 38.5 ma max. @ 24 VDC 16-328 ft. (5m to 100m) Conventional Detection Accessories Complementing System Sensor s detection products are a host of accessories sories designed to enhance installation, test, operation, and maintenance. SENS-RDR RRS-MOD 2W-MOD2 RT A77-AB2 XR2B A77-AB RMK400 SMB600 MOD400R A77-716B APA451 BEAMLRK BEAMMMK BEAMSMK BEAMHK BEAMHKR RA400Z RTS451 RTS451KEY Description i 3 series infrared sensitivity reader i 3 series reversing relay / synchronization module i 3 series loop test and maintenance module i 3 series removal/replacement tool i 3 series retrofit adapter bracket 100 series installation/removal tool 100 series retrofit adapter bracket 100/400 series recessed mounting kit 100/400 series surface mount kit 100/400 series field sensitivity test module End of line power supervision relay Remote annunciator with piezo alarm Long-range kit for BEAM1224/BEAM1224S Multi-mount kit for BEAM1224/BEAM1224S Surface-mount kit for BEAM1224/BEAM1224S Heater kit for transmitter/receiver unit Heater kit for reflector Remote annunciator for spot and duct smoke detectors Remote test station accessory Remote test station accessory with key 3

A u d i b l e / V i s i b l e N o t i f i c a t i o n Selectable Output Horn/Strobes The Selectable Output Horn/Strobes offer a unique combination of unsurpassed performance with low-profile aesthetics, dual voltage in one unit, candela settings of 15, 15/75, 30, 75, and 110cd, and eight separate horn settings. P1224MC P1224MCW Candela FWR DC FWR Current Horn DC Current Horn 12V 24V 12V 24V 12V 24V 12V 24V 15 112 64 127 59 46 58 44 57 15/75 135 74 127 69 46 58 44 57 30 N/A 93 N/A 90 46 58 44 57 75 N/A 158 N/A 160 46 58 44 57 110 N/A 208 N/A 209 46 58 44 57 Selectable Output Strobes The Selectable Output Strobes operate at 12 and 24 volts and offer a full complement of candela settings. S1224MC Candela FWR S1224MCW DC 12V 24V 12V 24V 15 112 64 127 59 15/75 135 74 127 69 30 N/A 93 N/A 90 75 N/A 158 N/A 160 110 N/A 208 N/A 209 Selectable Output Speaker/Strobes The Selectable Output Speaker/Strobes offer the same strobe features as the Strobes and Horn/ Strobes and the same highly intelligible sound quality as the voice evacuation products. The SP2R1224MCK is rated from 40 F to +151 F for outdoor operation. SP2R1224MC, SP2R1224MCK (outdoor) Candela FWR DC SP2W1224MC 12V 24V 12V 24V 15 112 64 127 59 15/75 135 74 127 69 30 N/A 93 N/A 90 75 N/A 158 N/A 160 110 N/A 208 N/A 209 Horns The Horns provide eight field-selectable and reversible settings, including high or low volume, temporal or non temporal, and electromechanical or 3000HZ. FWR Current DC Current 12V 24V 12V 24V 4 H12/24 H12/24W 46 58 44 57

Selectable Output Outdoor Horns and Strobes The Selectable Output Outdoor Horns and Strobes contain the same features as the indoor horns and strobes and are UL listed and NEMA 3 approved. Candela FWR DC FWR Current Horn DC Current Horn 12V 24V 12V 24V 12V 24V 12V 24V P1224MCK 15 112 64 127 59 46 58 44 57 15/75 135 74 127 69 46 58 44 57 30 N/A 93 N/A 90 46 58 44 57 75 N/A 158 N/A 160 46 58 44 57 110 N/A 208 N/A 209 46 58 44 57 S1224MCK 15 112 64 127 59 15/75 135 74 127 69 30 N/A 93 N/A 90 75 N/A 158 N/A 160 110 N/A 208 N/A 209 H12/24K N/A N/A N/A N/A N/A 46 58 44 57 * For outdoor applications, mount devices to weatherproof back box, model WBB. Selectable Output Chimes and Chime/Strobes The Selectable Output Chimes and Chime/Strobes (wall-mounted and electronic) have sixteen field-selectable chime tones and three volume settings. Intended for private mode applications, the chime meets UL 464 and the chime/strobe meets UL1971. CH24MC Candela CH24MCW CH1224 CH1224W 12/24 Electronic Chime Current Draw (ma): Tone FWR 24 15 64 59 24 15/75 74 69 24 30 93 90 24 75 158 160 24 110 208 209 DC Current Draw at 8-33 VDC: 18-61 ma (Average current draw varies with tones selected. See table below.) Current ratings per System Sensor testing at 12VDC and 24VDC. 8 Volts 12 Volts 24 Volts 33 Volts Low Med. High Low Med. High Low Med. High Low Med. High 1.2K Repeating 1-Second Chime 51 52 55 53 54 56 57 61 52 59 61 64 1.0K Repeating 1-Second Chime 48 50 54 51 52 54 54 57 60 57 60 62 0.8K Repeating 1-Second Chime 47 47 53 49 51 52 53 55 58 55 58 60 1.2K Repeating 1 /4-Second Chime 53 54 58 55 57 59 59 61 64 61 63 66 1.0K Repeating 1 /4-Second Chime 49 50 54 51 53 54 55 57 60 57 59 62 0.8K Repeating 1 /4-Second Chime 48 50 53 50 52 53 54 56 59 56 58 61 1.2K Temporal 3 Chime 51 52 56 52 54 55 55 57 61 58 60 63 1.0K Temporal 3 Chime 48 49 54 49 51 51 53 55 58 55 57 60 0.8K Temporal 3 Chime 46 47 51 48 50 51 52 54 57 54 56 59 1.2K Single Stroke Chime 52 53 58 52 54 56 56 58 62 58 60 64 1.0K Single Stroke Chime 47 48 53 50 51 59 53 55 58 56 58 62 0.8K Single Stroke Chime 47 48 53 49 50 52 54 56 60 56 59 61 3.0K Continuous Electromechanical 56 57 61 59 60 67 65 68 70 68 70 74 3.0K Temporal Electromechanical 51 52 56 53 54 61 56 59 62 58 60 64 0.5K Continuous Electromechanical 48 49 53 51 52 56 54 57 60 56 55 61 0.5K Temporal Electromechanical 45 47 51 47 49 53 51 52 58 52 54 60 5

Ceiling Mount Horn/Strobes Since their introduction, the SpectrAlert series of ceiling-mounted notification devices has become widely regarded as the most complete and innovative in the industry. Candela FWR Max. DC Max. FWR Max. Current Horn PC2415 PC2415W 24 15 68 64 57.5 57 PC241575 PC241575W 24 15/75 77 78 57.5 57 PC2430 PC2430W 24 30 107 113 57.5 57 PC2475 PC2475W 24 75 197 205 57.5 57 PC2495 PC2495W 24 95 239 274 57.5 57 PC24115 PC24115W 24 115 298 325 57.5 57 PC24177 PC24177W 24 177 399 489 57.5 57 DC Max. Current Horn Ceiling Mount Strobes The circular Ceiling Mount Strobes are modeled specifically for ceiling use. The strobes offer a full complement of candela settings. Candela FWR Max. Current SC2415 SC2415W 24 15 68 64 SC241575 SC241575W 24 15/75 77 78 SC2430 SC2430W 24 30 107 113 SC2475 SC2475W 24 75 197 205 SC2495 SC2495W 24 95 239 274 SC24115 SC24115W 24 115 298 325 SC24177 SC24177W 24 177 399 489 DC Max. Current Ceiling Mount Speaker/Strobes The Ceiling Mount Speaker/Strobes offer the same clarity and intelligibility as the speaker products and the full complement of candela settings available throughout the ceiling product family. Candela FWR Max. Current SP2C2415 24 15 68 64 SP2C241575 24 15/75 77 78 SP2C2430 24 30 107 113 SP2C2475 24 75 197 205 SP2C2495 24 95 239 274 SP2C24115 24 115 298 325 SP2C24177 24 177 399 489 DC Max. Current 6

Dual Evacuation Speakers The Dual Evacuation Speakers provide the highly intelligible sound quality essential to voice evacuation. These products are low in harmonic distortion and feature a frequency range that exceeds most codes. The SP201K is rated from 40 F to +151 F for outdoor operation. Description Speaker N/A SP200W Round 7 3 /8 grille, 1 /4-2 watt power tap 25.0/70.7 Vrms SP201R SP201W Square 5 grille, 1 /4-2 watt power tap 25.0/70.7 Vrms SP201K Outdoor listed, square 5 grille, 1 /4-2 watt power tap 25.0/70.7 Vrms Sync Circuit Module The SpectrAlert Sync Circuit Module is designed to simplify installations requiring signal synchronization. Average Current (ma) Peak Current (ma) In-rush Current (ma) DC FWR DC FWR DC FWR MDL MDLW 12 10 12 30 31 87 122 24 11 15 35 37 198 262 Accessory Mounting Plates The Accessory Mounting Plates can be used with wall- or ceiling-mount horns, strobes and horn/strobes. Description S-MP S-MPW Small footprint mounting plate for single gang only BBS BBSW Surface-mount back box skirt D-MP D-MPW Universal mounting plate (replacement) WBB NA Weatherproof back box BBSC BBSCW Surface-mount back box skirt for ceiling mount products BBS-SP2R BBS-SP2RW Surface-mount back box skirt for wall mount speaker/strobe BBS-CHSR BBS-CHSW Surface-mount back box skirt for wall mount chime/strobe BBS-SP201R BBS-SP201W Surface-mount back box skirt for SP201 speakers 7

H V A C S y s t e m s M o n i t o r i n g During a fire, an HVAC system can deliver toxic gasses and smoke throughout a building unless that building is equipped with Innovair duct smoke detectors. The Innovair line features: Connectivity Up to 10 Innovair 4-wire devices can be interconnected so when one alarm is activated, auxiliary relays in others will initiate control over fans, dampers, doors, etc. Easy Installation Innovair duct detectors with duct widths from 12-18 inches are equipped with built-in sampling tubes. Accessory sampling tubes are also available for duct widths up to 12 feet. Captured cover screws and exterior mounting tabs simplify installation. Easy Maintenance and green LEDs assure quick and convenient status checks; the missing signal assures system integrity; the reset button on the front cover simplifies system covertesting. Model Description Wiring DH100LP DH100ACDCLP DH100ACDCLWP DH100ACDCI DH400ACDCIHT Photoelectronic low-flow duct smoke detector Photoelectronic low-flow duct smoke detector Watertight photoelectronic low-flow duct smoke detector Ionization duct smoke detector High-temperature ionization duct smoke detector 2151 Photoelectric no-flow/ low-fl ow smoke detector Air Velocity Range Temp. Range 2-wire 100-4000 ft/min 32-131 4-wire 100-4000 ft/min 32-131 4-wire 100-4000 ft/min 32-131 4-wire 500-4000 ft/min 32-131 4-wire 500-4000 ft/min 32-158 4-wire 0-3000 ft/min 32-120 Rating Alarm Current 12/24 VDC 4.2 VDC min at 10 ma, 6.6 VDC max at 130 ma Auxiliary Contact 24 VAC/DC or 120/240 VAC 70 ma max 2 Form C Auxiliary Relay NEMA 4 24 VAC/DC or 120/240 VAC 70 ma max 2 Form C Auxiliary Relay 24 VAC/DC or 120/240 VAC 70 ma max 2 Form C Auxiliary Relay 24 VAC/VDC or 120/220 VAC 95 ma max 2 Form C Auxiliary Relay 24 VAC/DC w/b114lpbt base; 120 VAC w/b114lp base 75 ma max 1 Form A & 1 Form C Auxiliary Relay Model Description SSK451 Multi-signaling accessory, remote test station with horn, allows local testing of a remote duct detector, for use with System Sensor DH100ACDC and DH400ACDC 15-35 VDC APA451 Remote annunciator with piezo alert 16-33 VDC RA400Z Remote annunciator for spot and duct smoke detectors 3.1-32 VDC RTS451 Remote test station accessory 2.8-32 VDC (Alarm LED) RTS451KEY Remote test station accessory with key reset 14-35 VDC (Power LED); 2.8-32 VDC (Alarm LED) RTC100 Remote test coil kit with low-profile ring (includes RTS451 remote test station) PS24LO(W) Mini-Alert add-on strobe for use with SSK451 or PA400W 16-33 VDC S p r i n k l e r Sy s t e m s M o n i t o r i n g WFD Series Waterflow Detector The WFD Series waterflow detectors are available in a range of sizes to accommodate fire sprinkler risers from two to eight inches. All units feature vane-type paddles and an adjustable mechanical relay. 8 Model Pipe Size Hole Size Pressure Rating Contact Ratings Triggering Threshold WFD20 2 1 1 /4 450 PSI 2 Form C: 10 A, 1 /2 HP @ 125/250 VAC; 2.5 A @ 6/12/24 VDC 4-10 GPM WFD25 2 1 /2 1 1 /4 450 PSI 2 Form C: 10 A, 1 /2 HP @ 125/250 VAC; 2.5 A @ 6/12/24 VDC 4-10 GPM WFD30-2 3 2 450 PSI 2 Form C: 10 A, 1 /2 HP @ 125/250 VAC; 2.5 A @ 6/12/24 VDC 4-10 GPM WFD35 3 1 /2 1 1 /4 450 PSI 2 Form C: 10 A, 1 /2 HP @ 125/250 VAC; 2.5 A @ 6/12/24 VDC 4-10 GPM WFD40 4 2 450 PSI 2 Form C: 10 A, 1 /2 HP @ 125/250 VAC; 2.5 A @ 6/12/24 VDC 4-10 GPM WFD50 5 2 450 PSI 2 Form C: 10 A, 1 /2 HP @ 125/250 VAC; 2.5 A @ 6/12/24 VDC 4-10 GPM WFD60 6 2 450 PSI 2 Form C: 10 A, 1 /2 HP @ 125/250 VAC; 2.5 A @ 6/12/24 VDC 4-10 GPM WFD80 8 2 450 PSI 2 Form C: 10 A, 1 /2 HP @ 125/250 VAC; 2.5 A @ 6/12/24 VDC 4-10 GPM

T-Tap Series Waterflow Detector The T-Tap waterflow detectors are compatible with one-inch NPT style connections, making them ideal for residential or branch line signaling applications. Model WFDT WFDTH WFDTNR Compatible Tee Fittings 1 to 1 1 /2 NPT threaded ferrous and brass, 1 to 2 sweat brass, 1 1 /2 polybutylene plastic, 1 PVC plastic tees having a 1 threaded NPT branch, and 2 cast and malleable threaded tees. 1 to 1 1 /2 NPT threaded ferrous and brass, 1 to 2 sweat brass, 1 1 /2 polybutylene plastic, 1 PVC plastic tees having a 1 threaded NPT branch, and 2 cast and malleable threaded tees. 1 to 1 1 /2 NPT threaded ferrous and brass, 1 to 2 sweat brass, 1 1 /2 polybutylene plastic, 1 PVC plastic tees having a 1 threaded NPT branch, and 2 cast and malleable threaded tees. Pressure Rating Contact Ratings 250 PSI 2 Form C: 10A @ 125/250 VAC, 2.5 A 24 VDC 250 PSI 2 Form C: 10A @ 125/250 VAC, 2.5 A 24 VDC 250 PSI 2 Form C: 10A @ 125/250 VAC, 2.5 A 24 VDC Triggeringing Threshold 4-10 GPM 4-10 GPM 4-10 GPM Supervisory Switches System Sensor manufactures devices for supervising a variety of control valves, including outside screw and yoke, post indicator, butterfly, and rising and non-rising stem gate. Model Description Valve Size Contact Rating OSY2 PIBV2 PSP1 Used to monitor the open position of an Outside Screw and Yoke type gate valve Used to monitor the open position of post indicator and butterfl y control valves A plug-in special application supervisory switch designed for applications where no other type of listed valve supervisory switch can be used 1 to 12 10 AMP @ 125/250 VAC; 2.5 AMP @ 6/12/24 VDC 10 AMP @ 125/250 VAC; 2.5 AMP @ 6/12/24 VDC Plug Contacts: 250mA @ 6/12/24 VAC/DC, normally open Cover Tamper: 5A @ 125/250 VAC, 2.5A @ 6/12/24 VAC Maximum Current 250mA EPS Series Pressure Switches The EPS Series Pressure Switches are offered in three varieties and with one or two SPDT contacts. The EPS10 alarm pressure switches are ideal for dry pipe systems while the EPS40 and EPS120 supervisory pressure switches are intended for supervising air pressure in pipes or pressure tanks. Model EPS10-1 EPS10-2 EPS40-1 EPS40-2 EPS120-1 EPS120-2 Maximum Pressure Maximum Adjustment Range Differential Contact Rating 250 psi 4 to 20 psi 3 psi 10 A, 1 /2 HP @ 125/250 VAC; 2.5 A @ 6/12/24 VDC 250 psi 10 to 100 psi 3 psi @ 10 psi and 6 psi at 100 psi 250 psi 10 to 200 psi 3 psi @ 10 psi and 9 psi at 200 psi 10 A, 1 /2 HP @ 125/250 VAC; 2.5 A @ 6/12/24 VDC 10 A, 1 /2 HP @ 125/250 VAC; 2.5 A @ 6/12/24 VDC Threaded Connection 1 /2 NPT male reinforced nylon 1 /2 NPT male reinforced nylon 1 /2 NPT male reinforced nylon Alarm Bells The Alarm Bells offer high output notification in security and fire alarm systems. Six, eight and ten inch models are available for 24 VDC and 120 VAC systems. Model Gong Size Nominal Sound Output Maximum Current SSM24-6 6 24 VDC 16-33 VDC 82 db DC - 31.1 ma / FWR - 53.5 ma SSM24-8 8 24 VDC 16-33 VDC 80 db DC - 31.1 ma / FWR - 53.5 ma SSM24-10 10 24 VDC 16-33 VDC 81 db DC - 31.1 ma / FWR - 53.5 ma SSV120-6 6 120 VAC 96-132 VAC 85 db 53 ma SSV120-8 8 120 VAC 96-132 VAC 82 db 53 ma SSV120-10 10 120 VAC 96-132 VAC 82 db 53 ma 9

System Sensor is a global manufacturer of fire detection and notification devices, specializing in smoke detection and notification technology. System Sensor places a premium on research and development, resulting in products that are reliable, sophisticated and designed for real-world applications. With sales, service and manufacturing facilities throughout the Americas, Europe and Asia, System Sensor s high quality, innovative products are the most comprehensive in the industry. 2005 System Sensor. The company reserves the right to change specifications at any time. A05-0363-002 07/05 #1445