IONIZER SS229 SS229. ionizer catechin

Similar documents
IONIZER SS225 SS225. ionizer anti-mite

IMPORTANT SAFETY INSTRUCTIONS

Dehumidifier/Dryer. Model: EDV Please read the instruction manual before operating. Keep in a safe place for future reference

12L Dehumidifier Model: HG00923

DESICCANT DEHUMIDIFIER

SUKI. Dehumidifier WDH-928DB -20R. User s Manual

Owner s Manual SPLIT-TYPE ROOM AIR CONDITIONER

USERS MANUAL. Desiccant Dehumidifier. Model: ECO DD122FW CLASSIC. Read This Manual

PORTABLE AIR CONDITIONER

LUCCI AIRFUSION BREEZE WALL FAN INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE

Owner s Manual CS

WALL MOUNTED AIR CONDITIONER OWNER S MANUAL

Dehumidifier. User Manual

FLOOR-STANDING SPLIT TYPE ROOM AIR CONDITIONER

IMPORTANT SAFETY INSTRUCTIONS

USERS MANUAL. Desiccant Dehumidifier. Model: ECO DD322FW CLASSIC

WALL MOUNTED AIR CONDITIONER

This dehumidifier is both compact and lightweight. The casters on the bottom of the unit make it easy to move from room to room.

Table of Contents SAFETY FIRST. Owner s Manual. Safety Precautions Unit Specifications and Features Manual Operation (Without Remote)...

AIR COOLER OPERATING INSTRUCTIONS MODEL NO: ARC-30 ARC-30. Instruction Manual

GDDEM10 DEHUMIDIFIER

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS

Inverter Split-type Room Air Conditioner

SH3020 USER INSTRUCTIONS

COMPACT PORTABLE AIR CONDITIONER USER MANUAL

Infrared Portable Space Heater

Infrared Portable Space Heater

INVERTER SPLIT-TYPE ROOM AIR CONDITIONER

Infrared Portable Space Heater

NEXXOS INVERTER USER MANUAL

PDA20DX Air Purifying Dehumdifier Manual

PORTABLE AIR CONDITIONER OWNER S MANUAL

DEHUM3 INSTRUCTION MANUAL SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

INVERTER SPLIT-TYPE ROOM AIR CONDITIONER

Dehumidifier. Instruction Manual. Model DH-320/A

SILENT 12 PORTABLE AIR CONDITIONER USER MANUAL

USER'S MANUAL INVERTER SPLIT-TYPE ROOM AIR CONDITIONER

DEHUMIDIFIER USER MANUAL 95 PINT FOR MODEL: 3PAD95. Quick Start Tips on Page 1 COMFORT...BUILT TO LAST

Attention. Please handle this product with care and inspect it regularly to ensure it is in good working order.

Owner s Manual. Fairwind Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER CS

Air Dehumidification System. Instruction Book CLI-DH8D

PORTABLE AIR CONDITIONER (LOCAL)

ROOM AIR CONDITIONER. Read This Manual. Before using your air conditioner, please read this manual carefully and keep it for future reference.

CPG*CA CPG*CD CGC*CA CGC*CD CIM*CA CIM*CD CPP*CA CPP*CD

KSD-35 DR11 KUE-35 DVN11

Limited Edition Music Heater

USER S MANUAL AQV09J Series AQV12J Series AQV18J Series AQV24J Series

PORTABLE AIR CONDITIONER OWNER S MANUAL

Room Air Conditioners

7Litre Evaporative Cooler With Remote

LOCAL AIR CONDITIONER

PORTABLE AIR CONDITIONER

PORTABLE AIR CONDITIONER (LOCAL)

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

OPERATING INSTRUCTIONS

OWNER S MANUAL VMH 09/12/18/24

10L Evaporative Cooler with Timer

USER S MANUAL AQV09V A Series AQV12V A Series AQV18V A Series AQV24V A Series

USER MANUAL. Safety Precautions. Unit Specifications and Features. Operating Instructions. Installation Instructions.

A1 A7 D1 D2 D3 E6 E7 E8

GMSG OWNER S MANUAL SPLIT-SYSTEM ROOM AIR CONDITIONER CONTENTS

Premium Low Energy Compressor Dehumidifier with Digital Humidistat CD16LE 16 litres per day USER MANUAL

DD122 CLASSIC MK5. FOR MORE LANGUAGES, PLEASE VISIT:

USERS MANUAL. Desiccant Dehumidifier. Model: ECO DD322FW SIMPLE. Read This Manual

SPLIT - TYPE ROOM AIR CONDITIONER

Portable Air Conditioner USER MANUAL

20L/D DEHUMIDIFIER Model Number: IG9800

Operating Instructions Air Conditioner

Homeowner s Installation Instructions & Operating Manual

Air always contains a certain amount of water in the form of vapour. This determines the

FLOOR-STANDING TYPE AIR CONDITIONER USER'S MANUAL

Dr. Infrared Heater Elite Series

DESICCANT TYPE DEHUMIDIFIER DESHUMIDIFICATEUR D AIR À ADSORPTION ADSORPTIONSTROCKNER ADSORPTIE LUCHTONTVOCHTIGER TD-Z80

Premium Low Energy Compressor Digital Humidistat Dehumidifier & Air Purifier with UV and Plasma Ionizer

DD12E DEHUMIDIFIER USER'S MANUAL CONTENTS. VOLTAGE: V~50Hz

Panel Heater Slim 1.5kw MODEL: NDK15-12K

USER MANUAL TPS-M5/M55/M555

Utopian Split A/C. Thank you for purchasing this quality Split A/C system!

20L Dehumidifier. Model Number: LDH V AC 50/60Hz 440W

SENA/09HF/IZ SENA/09HF/OZ SENA/12HF/IZ SENA/12HF/OZ SENA/18HF/IZ SENA/18HF/OZ SENA/24HF/IZ SENA/24HF/OZ

Portable Room Air Conditioner and Heat Pump

Portable Air-conditioner Use and Care Manual

Owner s Manual Super-Slim Four-Way Cassette

CLIM9000CE PORTABLE AIR CONDITIONER USER MANUAL

COMPRESSOR DIGITAL DEHUMIDIFIER

ULTRASONIC MIST FAN 80W A GILMAN GROUP BRAND

Dual-Hose Portable Air Conditioner User Manual

USER'S MANUAL. High Wall On/Off. R-410A 50Hz YS9FZC009/012/018BAEFAFX YTZC09/12/18

DUE-1237 DEHUMIDIFIER Owner s Manual

Split Air Conditioner

PORTABLE AIR CONDITIONER (LOCAL)

Local Air Conditioner

Reverse Cycle Split System Air Conditioner

SPLIT-TYPE ROOM AIR CONDITIONER

OWNER'S MANUAL MODEL: D-40ES. For any service needs, call


MS7 Single Zone Mini Split System Air Conditioners and Heat Pumps

EVAPORATIVE AIR COOLER SERVICE MANUAL

IG9813 USER MANUAL. 12 Litre Dehumidifier White. Batch code:

CA-707. Manual. Read these instructions carefully before you start using the dehumidifier and keep the manual for later usage.

Transcription:

IONIZER SS229 SS229 ionizer catechin

DEHUMIDIFIER SAFETY Various symbols are used throughout this manual and on the product to alert you to measures for safe use. These symbols are classified according to the seriousness of the risk of ignoring them, and are explained below. Your safety and that of others is very important We have shown a number of important safety tips in this manual and on your appliance. Always read and observe these safety tips. The appliance shall be installed in accordance with national wiring regulations. This product must be connected to the ground wire. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. This instruction shall also be found on our website https://www.whirlpool.com.hk/ 1

PROBLEM SOLVING The compressor is set to rest for at lest three minutes after the unit being switched off or just started so as to eusure a smooth start of the compressor. This action also extends the working life of the unit. 2

DEHUMIDIFIER SAFETY 220-240Vac, 50Hz. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. Do not splash or wash the unit. The may cause electric shock or fire. Otherwise water may spill and damage household effects. Make sure the louver slide cover is opened before operating. Closed air outlet may cause overheat or fire. 3

DEHUMIDIFIER SAFETY Check and replace the 3-in-1 filter every 3-6 monthes. Check and clean the nano-silver pre-filter every two weeks. Insufficientventilation may cause low dehumidification performance, frosting, dripping, overheating or fire. Do not touch the sensor lens. The sensor cannot work well if the lens is stained. Follow the instructions in P.14 to clean the lens if needed. 4

1. Automatic drying mode for more convenience The unit can automatically adjust its airflow to the wet clothes and dry them effectively. Pre-scan: a full range scan before dehumidifying. Drying: automatically blows dried air to, or swings toward, the specific directions according to the result of scan. 2. Unique air purifying function The unit contains a nano-silver pre-filter and a 3-in-1( (catachin, deodor, charcoal) filter. It operates as dehumidifier and air purifier simultaneously or simply as an air purifier. Negative ions are provided with discharged air under the dehumidifying or air purifying mode (low fan speed) to give you fresh and healthy breath. 3. High efficient drying and dehumidifying Three range selections for the vertical louver in a maximum range of 150 O. Wide or narrow horizontal airflow selections in a maximum range of 70 O. Thus, the dried air can be delivered to the desired portions. Dry clothes quickly and efficiently. 4. Four function modes, additional internal drying function, and three colors humidity display Dehumidifying, drying, auto drying and air cleanng modes. You can inhibit mildew on the cooler inside the machine by applying a one-hour internal drying mode after turning off. The humidity status display shows room humidity status in three corresponding colors. 5. Movable and compact Compact design with retractable handle makes lifting easy. Its slim shape enables storage in a laundry room or other confined space. 6. Automatic defrost Automatic defrosting ensures dehumidifying above 5 O C. SS229 FEATURES SPECIFICATIONS Dimensions in mm 20 liters per day (30 O C, 80%RH). 12.1 liters per day (26.7 C, 60%RH). 574 5 387 172

POSITIONING THE UNIT Do not insert small objects, that could cause damage and danger. SAFE OPERATION could cause dripping. The slide cover was closed for the shipment status. Open it before operating. 6

BEFORE USING Installing 3-in-1( catechin, deodor, charcoal) filter. 3-in-1 filter 3-in-1 filter and fit as illustrated When bucket is full or inserted, Full (bucket-full indicator) illuminates and stops the unit. Continuous draining is dipicted in page 12. 7

CONTROL PANEL 16 17 18 15 11 12 13 14 2 HR 4 HR 8 HR 12 HR 8 9 10 LOW AUTO HIGH 4 5 6 7 3 2 1 SS 229 F louver setting E D TIMER key FUNCTION key louver setting HUMIDITY key C B A ON/OFF key A ON/OFF key 1. Plug to the mains and the default mode is off. Press the button first time to set the unit operate in Dehumidifying mode, the indicator lights and other functions are off. 2. The unit will remember the operation settings when there is no power break. It will run the same operation settings (including louver, timer, humidity and function) for the next boot. B FUNCTION key Dehumidifier operation modes: 1st press - Laundry, 2nd press - Automatic drying, 3rd press - Air cleaning, 4th press - Dehumidifying, and so looped. 3 Internal drying: Workable after shutdown. The machine will run the fan for an hour to help drying the cooler, then shut down automatically. 4 Dehumidifying: Low fan speed dehumidifying, the humidity can be set. 5 Laundry: High fan speed dehumidifying, the humidity can not be set. 6 Automatic drying: Automatically adjust the louver to the wet clothes by infrared detector sensing. See page 10 for details. 7 Air cleaning with ionizer: In low fan speed (Ionizer is also on in Dehumidifying mode). C HUMIDITY key Press to set the humidity range as the indicator lights. When all indicators are off, it means continuous dehumidifying. This setting is applicable to Dehumidifying mode only. 8 Low 9 Auto 10 High continuous (light off ) D 11 2 12 4 8 14 12 hours, continuous (light off ) 13 TIMER key Press to set autooff timer as the indicator lights. When all indicators are off, it means continuous running. 8

E Horizontal louver setting LOUVER SETTING Press and the indicator lights, the blades swing in narrow and wide conversions. When the indicator is off, the blades stop at the time you press. 15 narrow-angle, wide-angle, stop (light off) F Vertical louver setting Press and the louver swings vertically in 3 ranges. The indicators light accordingly. When all lights are off, the louver stops at the angle when you press. 16 up, 17 front, 18 wide-angel, stop (light off) Note: When Auto dry is selected, the horizontal vertical louvers are automatically controlled, manual setting is unavailable. Note: 1.Vertical louver will go to the closed position after plugged or shut down. 2.Make sure the slide cover has been opened before turn on. 3.The vertical louver will automatically turn upwards, and the horizontal blades turn foreward when the unit is re-plugged and turned on. Make sure the slide cover has been opened 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 INDICATORS : Flashes when bucket is full or not positioned. Please empty or reposition. : Flashes when defrosting. It will return to dehumidifying when finished. : Indicates an internal dry (running for one hour), applicable only after the unit off. : Dehumidifier is on (low fan speed), ionizer is on. : High fan speed laundry drying. : Automatic detecting and drying. : Air cleaning only. Ionizer is on. Low : The unit stops dehumidifying automatically when reaches 60-70% humidity. Auto : The unit stops dehumidifying automatically when reaches 50-60% humidity. High : The unit stops dehumidifying automatically when reaches 40-50% humidity. 2 hours : The unit stops automatically after 2 hours. 4 hours : The unit stops automatically after 4 hours. 8 hours : The unit stops automatically after 8 hours. 12 hours : The unit stops automatically after 12 hours. : The horizontal blades swing between narrow and wide. : The vertical louver swings upwards about 75 o. : The vertical louver swings forwards about 75 o. : The vertical louver swings in wide range about 150 o. Status Humidity indicator: When room humidity is around above 60%: lights orange color. When room humidity is around 50~60%: lights yellow color. When room humidity is around below 50%: lights green color. 9 Humidity Status indicators

AUTOMATIC DRYING Automatic drying (without setting humidity and louver direction): It includes scanning stage and drying stage with an infrared detector. 1.Scanning stage: With the horizontal blades set at wide-angle and the detector turned to left top vertical louver swings up-down twice then moves to the top. The detector turns back and forth along with the vertical louver gradually downwards for a whole range scan, The machine determines the location of wet clothes based on the results of scan. 2.Drying stage: Adjust the louver and blades to the wet clothes area based on the result of scanning. Every 20 minutes for a cycle (rescanning and drying). If there is no wet clothes detected, the vertical louver moves up about 20 degrees, and the horizontal blades take a wide angle blowing. The detection range The detector senses the temperature of surroundings, within the range of about 150 o vertical and 70 o horizontal, to determine the position of wet clothes. The unit detects in a horizontal backand-forth and gradual move-down motion. Under 3m (150 O ) About 1m About 1.5m (70 O ) The detector may be less sensitive in following conditions: Low temperature in winter. The dehumidifier is far away from clothes (over 1 m). A small cloth.(please set in closer.) The detector is stained (see the P.14 for cleaning). Automatic louver control When clothes are less or concentrated, the horizontal blades will be set in a narrow angle, and the vertical louver will be fixed or swing in a small angle. When clothes are more or in a large area, the horizontal blades will take a wide angle, and the vertical louver will swing up and down. 10

TIPS OF CLOTHES PLACEMENT Please refer to the followings that may speed up your clothes drying. Put laundry in the range of the sensor The distance between clothes and the dehumidifier is preferable within 1 m. Put the dehumidifier closer when the clothing is less. Heavy clothes are not easy to dry, hanging closer to the dehumidifier.heavy clothes need more time to dry, so hanging them in front of of the dehumidifier, and try to even out the folds of the clothing. under 3m (150 O ) under 1m under 1.5m During the scanning stage, DO NOT step into (70 O ) the scanning zone, that will influence the scanning result. Preferably set the Automatic drying after finishing placing the clothes. When adding or re-arranging clothes, you may press the Function key to re-select the Automatic drying for a re-scanning. Proper spacing between clothes over 1m about 5cm Air circulation can speed up the drying time, so be sure to set clothing distance of about 5 cm. The space between the clothing should not be too large, or the drying efficiency of the dehumidifier will be reduced. Please fix the clothes properly to prevent them moved by the airflow. Hanging in front of the dehumidifier 1.5m Hanging on top of the dehumidifier 1.5m under 1m 0.5m Heavy clothes Handing the heavy clothes in the middle of airflow range. Light clothes such as underwear or socks are also recommended to be so. Make sure the airflow can reach the farest clothes. Make sure the air-blow can reach the farest clothes when handing above the dehumidifier. 11

NOTE Continuous draining MOVING 12

FILTER REPLACING AND CLEANING Replacing the 3-in-1 filter Do not wash 3-in-1 filter 3-in-1 (catechin, deodor, charcoal) filter. 13

2 HR 4 HR 8 HR 12 HR LOW AUTO HIGH 2 HR 4 HR 8 HR 12 HR 2 HR 4 HR 8 HR LOW AUTO HIGH LOW AUTO HIGH MAINTENANCE Cleaning the unit 1. Switch off and unplug. 2. Clean air intake and outlet with a soft cloth. Dust tends to accumulate here. 3. Do not use petrol or solvents. 4. Clean the surface with a soft damp cloth, using only water or mild detergent. 5. Wipe dry with a dry cloth. NOTE: Never use water to wash the unit. Cleaning the sensor 1. Wipe the sensor gently with soft stick. 2. Do not use water, alcohol, petrol or other solvent, that may cause malfunction. Internal drying Press the function key to start Iternal drying after shutdown of dehumidifying. It dries the machine internal moisture, inhibits mildew on the cooler. The internal dry approximately runs for an hour Preparing for restore 1. Run Internal drying (automatically for an hour) or Air cleaning at least an hour to dry the inside. 2. Switch off and unplug. 3. Clean and dry the bucket. 4. Close the slide cover or cover the unit to prevent dust accumulation. Store vertically in a cool, dry place. Do not expose to diresct sunlight. 12 HR Close the slide-cover 14