LZR -WIDESCAN. Motion, Presence, and Safety Sensor for Industrial Doors (US version) DESCRIPTION ENGLISH

Similar documents
LZR -WIDESCAN OPENING, PRESENCE & SAFETY SENSOR FOR INDUSTRIAL DOORS

LZR -FLATSCAN SW SAFETY SENSOR FOR FULL- AND LOW-ENERGY AUTOMATIC SWING DOORS. Visit website for available languages of this document.

LZR -FLATSCAN SW SAFETY SENSOR FOR FULL- AND LOW-ENERGY AUTOMATIC SWING DOORS

LZR -H110. LASER SCANNER FOR BARRIERS & GATES with max. detection range of 5.0 m x 6.5 m (16.5 ft x21 ft) User s Guide

LZR -I30. max. detection range of 30 ft x 30 ft LASER SCANNERS FOR INDUSTRIAL DOORS LZR-I Page 1 of 12

LZR -I100/ -I110. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

XGUARD-10/-5. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

Download the BEA DECODER app for a quick overview of settings

Download the BEA DECODER app for a quick overview of settings

1. LCD 2. radar antenna (narrow field) 3. radar antenna (wide field) 4. AIR-curtain width adjustment 5. AIR-lenses

active infrared 875 nm < 250 mw/m² motion & presence 157 in x 157 in (emitting spots**) 2 in/s to activate detection 250 ms 15-45

ACTIV8 ONE OFF. 1 Tips USER S GUIDE COMBINED RADAR OPENING AND ACTIVE INFRARED SAFETY SENSOR. 1 Description. 2 Symbols.

DDS-SSENSOR - INSTALLATION MANUAL. Installation Manual DDS-S SENSOR

BODYGUARD-T USER S GUIDE

Motorised Infrared Optical Beam Smoke Detector. User Guide

Motorised Infrared Optical Beam Smoke Detector. User Guide

FIRERAY 5000 range USER GUIDE

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

DDS-A / DDS-B HYBRID SENSOR

HR-Robus. Included INSTALLATION INSTRUCTIONS. Industrial Door Microwave Motion Sensor

Laser Distance Sensor Type M Analog-Output

EasyTronic III MANUAL SERVICE

Dimensions. Model Number 123. Electrical connection. Features. Indicators/operating means. Product information RMS-G-RC-NA.

RS Pro Infrared Temperature Sensor

DH400. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer.

Dimensions. Model Number. Electrical connection. Features. Product information. Indicators/operating means RMS-G-RC. Radar sensor

Apollo Intelligent Auto Aligning Beam Detector. User Guide

/ / 2018

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0111E FL0112E FL0122E. 367 mm.

E3M-V. Mark Sensor. Applications

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

Dimensions. Electrical connection. Model Number. Features. Indicators/operating means. Product information RAVE-D. Radar sensor

Section 1 General Description

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

Instruction manual. Digital Radar Motion Detector with Infrared Remote Control MWD BF. FEIG ELECTRONIC GmbH Lange Straße Weilburg/Lahn

End To End Optical Beam Smoke Detector. Additional Information

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

OWNERS MANUAL OPERATION GUIDE

SP-1000X. Panic Device Power Controller Installation Guide. Rev

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

DHR3. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer. INSTALLATION INSTRUCTIONS

POL-200-TS User Manual

Static Pressure Control

User Manual. Dryer Controller M720

Oxygen (O2) Single-Point Gas Detection System

Dimensions. Electrical connection. Model Number. Features. Indicators/operating means. Product information RAVE-D-NA. Radar sensor

Dryer Controller M720

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Control box FSTronic DES-FS

INDEX. Installation recommendation

BURGLAR ALARM PANEL BS-468

CommStat 4. Controller for Redundant Telecom HVAC Systems PRODUCT DATA SHEET. Features and Benefits

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

B-40/B-41 Modulating Temperature Controller

USER'S MANUAL PU SENS 01 (A11) PU SENS 01 (A19) Sensor Control Panel

Original operating instructions Safety switch with guard locking AC901S AC902S

BSR Addressable Fire Detection control panel. Installation operation manual

DUAL OPTIC. Installation manual

LaserGuard2. Laser Collision Avoidance System. Part Number: R1 April 2015 Copyright 2015 Magnetek Material Handling

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

Detector switch - Dual Tech SCS

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual

General Purpose IO Technical Manual

DE5300 Delayed Egress System. General Information

Watchguard WGAP864 User Manual

Remote Chexit Module (RCM) System. General Information

RCS Residential Control Systems Inc.

ABLOY DA460 SWING DOOR OPERATOR. Installation and commissioning manual

FEC400 Series. Installation Manual

Laser Series. Highly Visible Alignment Lasers For Visually Demanding Surfaces

Touch Screen Thermostat. MTSC/SUPER/CO2, MTSC24/SUPER/CO2 Series. MTS/SUPER/CO2, MTS24/SUPER/CO2 Series. Owner s manual and technician settings

Carbon Monoxide Transmitter

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

PD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual

2 Ensure that all personnel in the area are wearing the appropriate protective eyewear.

User Manual 120/240/300 Outdoor Motion Detector

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

English. Italiano. Português. Françias. Español

INDICE. Installation recommendation

Ethernet General Purpose

D8024, D9024, D10024 Analog Fire Alarm Control Panels Programming Guide

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

THX-DL Data Logger USER & INSTALLATION MANUAL V

SCS motion sensors Surface/wall mounting - PIR

Danfoss gas detection units

This is to certify that the optical output of the: SENSORNET LR-DTS Temperature Sensing System: (Variants Mark 1, Mark 2a and Mark 2b)

Scanning Laser Range Finder Smart-URG mini UST-10LN Specification

UV - Monitor UVT 16. Use. Description

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No , &

XUBLAPCNL2 photo-electric sensor - XUB - thru beam - laser - Sn 100m VDC - cable 2m

Leuze electronic. Dimensioned drawing. Electrical connection. Accessories: 150m ISO 9001

OPTICAL TURNSTILE SYSTEM

M2500 Engine Controller Installation Manual

CommStat 4 Controller

All- IN- ONE PROXIMTY STAND ALONE CONTROLLER OPERATION MANUAL MODEL: HA3021 VERSION: 3.60

Original operating instructions Photoelectric safety sensors (safety light curtain / safety light grid) Protected area width (range) 0...

IQ-Sense. 2/2 Introduction. 2/3 IQ-Sense photoelectric sensors. 2/5 IQ-Sense ultrasonic sensors. 2/6 4 IQ-Sense sensor module for ET 200S

PRODUCT BULLETIN. Rev. A Monitoring Station offering PN Rev. B as a direct replacement. OVERVIEW / DESCRIPTION

Transcription:

LZR -WIDESCAN Motion, Presence, and Safety Sensor for Industrial Doors (US version) ENGLISH DESCRIPTION 6 7 8 9 0 2 3 2 3 4 5 4. main connector 2. protection film 3. laser window 4. USB cap 5. LED display 6. cover 7. cover lock 8. cable passage 9. LCD screen 0. keypad. tilt angle adjustment screw () 2. parallel angle adjustment screw (2) 3. lateral angle lock screw () 4. mounting bracket 75.596.02 LZR-WIDESCAN 20802 Page of 5

INSTALLATION & MAINTENANCE TIPS Avoid extreme vibrations. Do not cover the sensor. Avoid moving objects and light sources in the detection field. Avoid exposure to sudden and extreme temperature changes. Keep the protection film during the mounting of the sensor. Remove it before launching a teach-in. It is recommended to clean the optical parts at least once a year or more if required due to environmental conditions. Do not use aggressive products to clean the optical parts. Avoid direct exposure to high-pressure cleaning. SAFETY The device contains IR and visible laser diodes. IR laser: wavelength 905nm; max. output pulse power 75W (Class according to IEC 60825-) Visible laser: wavelength 650nm; max. output CW power 3mW (Class 3R according to IEC 60825-) The visible laser beams are inactive during normal functioning. The installer can activate the visible lasers if needed. CAUTION! Use of controls, adjustments, or performance of procedures other than those specified herein may result in hazardous radiation exposure. Do not look directly into the laser emitter or the visible red laser beams. The door control t and the header cover profile must be correctly grounded. Only trained and qualified personnel are recommended to install and set up the sensor. Following installation, always test for proper operation before leaving the premises. The warranty is invalid if unauthorized repairs are made or attempted by unauthorized personnel. Page 2 of 5 75.596.02 LZR-WIDESCAN 20802

BASIC PRINCIPLES: FUNCTIONS & OBJECT There are 3 main functions that create 3 overlapping detection fields, each with certain detection characteristics: DOOR OPENS IF: MOTION - in field - certain object type - certain direction DOOR DOES NOT CLOSE IF: PRESENCE - presence in presence field - certain object type DOOR DOES NOT CLOSE IF: - presence in safety field SAFETY There are 4 additional opening functions. All detection functions can be combined to trigger a specific output (see output functions on page 2). Motion +: detection of other moving object type in field Pullcord: detection of object in learned, zone Speed: detection of object with a minimum speed Height: detection of object with a minimum height The sensor carries out a 3D object analysis and detects depending on height, width, and depth. H H D W D W 75.596.02 LZR-WIDESCAN 20802 Page 3 of 5

LED SIGNALS & SYMBOLS LED is on LED is off LED flashes LED flashes quickly LED flashes slowly x LED flashes x times LED flashes red-green Remote control Motion detection Presence detection Troubleshooting Pull cord detection Safety detection Factory value (User s Guide) Factory value (LCD) + Additional feature Important! Good to know Main functions: Motion Additional opening functions: Motion + Presence Safety Pullcord Speed Height OPENING THE SENSOR 2 3 Before opening the sensor, make sure the cover is not locked (red cover lock). Pull the two legs on top in order to open the cover. Remove the cover completely before installing the sensor. CLOSING THE SENSOR 2 3 Lock the sensor position by firmly fastening the angle lock screw. Reclip the sensor cover horizontally and close it as indicated. Lock the cover by turning the lock screw clockwise. Page 4 of 5 75.596.02 LZR-WIDESCAN 20802

MOUNTING & WIRING Mounting height: as high as possible (max. 9 6"). The size of the detection field depends on the mounting height. Mounting position: center of door or left corner. Mounting on the right side of the door should be avoided. H D W H D W 2 Verify that the angle lock screw is positioned as indicated. Unscrew slightly if necessary. Remove the mounting bracket from the sensor and secure it to the wall. You can also install the sensor directly without using the mounting bracket. 3 4 Position the sensor horizontally as shown and secure the sensor to the mounting bracket. Plug in the connector and pass the cable (PN 20.5399) through the cable passage without making a loop. 5 POWER * * OUTPUT OUTPUT 2 5 Teach-in reminder INSTALL * COM NO NC RELAY TEST Push OK to return to detection display. *output status powered during non-detection with factory values Connect the wires accordingly. The output functions can be configured if necessary (see page 9 or 2). 75.596.02 LZR-WIDESCAN 20802 Page 5 of 5

2 POSITIONING OF DETECTION FIELD Remove the blue protection film from the laser window. Activate the 2 visible laser spots by pressing twice or pressing on the remote control. PARALLEL ANGLE Make sure the curtain is parallel to the door by adjusting one or both screws on the side. TILT ANGLE AWAY CLOSER When the safety function is required, the red spots should be as close to the door as possible. Negative angles reduce the depth of the detection fields. Position the curtain closer to or farther away from the door by turning the screw at the top. LATERAL ANGLE Launch the POSITION WIZARD to position the detection field correctly in front of the door. LONG OK. Push and hold OK to launch the POSITION WIZARD. 2. Rotate the sensor in order to align the center of the red spots with the center of the door. Push OK. 3. Rotate the sensor until the LCD screen validates the position. Push OK to exit. Lock the sensor position by tightening the angle lock screw (see page 4). Page 6 of 5 75.596.02 LZR-WIDESCAN 20802

HOW TO ADJUST THE SENSOR BY REMOTE CONTROL 2 3 A After unlocking, the red LED flashes and the sensor can be adjusted by remote control. If the red LED flashes quickly after unlocking, enter an access code from to 4 digits. If you do not know the access code, cut and restore the power supply. Within minute, you can access the sensor without any code. To end an adjustment session, always lock the sensor......... If necessary, select the corresponding detection field before selecting the parameter and changing the value. The second LED indicates the detection field......... MOTION PRESENCE SAFETY Activate red spots on floor Teach-in: install Teach-in: Presettings Restoring... HOW TO ADJUST THE SENSOR BY LCD SHORT PRESS Enter the LCD menu. Select a folder, parameter, or value. Confirm a value and exit edit mode. Return to previous menu or display. PRESS 2 Activate red spots on floor. Scroll up or down. LONG PRESS Launch POSITION WIZARD. Select your Language before entering the first LCD menu. Within the first 30 seconds of power-on of the sensor or later in the diagnostics menu. Password Enter a Password if necessary. More Access advanced adjustments. >Diagnostics Go to the Diagnostics menu. Parameter Value Displayed value = Factory value Parameter Value Displayed value = Saved value 75.596.02 LZR-WIDESCAN 20802 Page 7 of 5

2 3 A 2 3 A 2 3 A 2 3 A 3 PROGRAMMING THE SENSOR TEACH-IN: INSTALL -- The teach-in zone (i.e. square in front of the 2 visible spots) must be completely clear. -- This teach-in must be launched each time a sensor angle has been changed. -- Make sure the blue protection film is removed! 5 s 0 s H W 5 D. Launch a teach-in by remote control. It starts after 5 seconds. 2. Wait while the position, angle, and height are learned and the background is analyzed. 3. The teach-in ends successfully. If not, refer to Troubleshooting on page 4. PRESETTINGS Choose one of the following presettings. They adjust parameters automatically according to your application. If necessary, you can also adjust a parameter independently via remote control (see page 9). STANDARD CORRIDOR CORNER - next to pedestrian door - exterior, large space - traffic from and to all directions - storage right and/or left - interior, confined space - traffic from and to all directions - no storage near door - interior or exterior - no parallel traffic - storage on one side of door SETTINGS SETTINGS SETTINGS - width: max, depth: max - object type: vehicle - direction: 00% - width: max, depth: max - object type: vehicle - direction: 00% - width: max, depth: max - object type: vehicle - direction: - width: max, depth: 6 6" - object type: vehicle - max presence time: 30 min - width: max, depth: 6 6" - object type: vehicle - max presence time: infinite - width: max, depth: 6 6" - object type: vehicle - max presence time: 30 min - width: max, depth: 3" - max presence time: infinite - uncovered zone: 5 3 4" - width: max, depth: 3" - max presence time: 0 min - uncovered zone: 5 3 4" - width: max, depth: 3" - max presence time: 0 min - uncovered zone: 5 3 4" OUT - Motion / Pull-Cord OUT - Motion / Pull-Cord / Safety OUT - Motion / Pull-Cord / Presence OUT2 - Safety OUT2 - Safety OUT2 - Safety REL - Motion+ and Height Trigger REL - Motion+ and Speed Trigger REL - Motion+ and Height Trigger Page 8 of 5 75.596.02 LZR-WIDESCAN 20802

OPTIONAL REMOTE CONTROL SETTINGS 2 3 A FACTORY VALUES 0 2 3 4 5 6 7 8 9 Teach-in Presettings Service Mode Factory Reset install standard corridor corner The service mode deactivates the presence and safety detection during 5 minutes and can be useful during an installation, a mechanical teach-in of the door or maintenance work. Exit the service mode by using the same sequence. full: complete reset of all values partial: reset of all values except IN/OUT full partial Red Spots Out Function* no change Out 2 Function* no change Relay Function* no change Pressing "magic wand" twice activates the 2 laser spots, enabling angle adjustments and sensor positioning. or or or presence safety presence safety presence safety + speed + speed + speed + height + height + height safety safety safety presence presence presence Always enter 3 digits for the F-parameter: st digit refers to output, 2nd to output 2, 3rd to the relay function (see p. 3 for detailed info) MOTION........ PRESENCE SAFETY Width Depth Object type Direction (see next pg for details) Immty Door zone OFF InvertField Width Depth Object type Max. presence time Immty Door zone OFF InvertField Width Depth Max presence (for objects < 6") Immty Uncovered Zone no no bi yes 30 s yes 30 s 2" 000 (min) 240 (max) factory default: 240 000 (min) 287 (max) factory default: 287 00% 2 3 4 vehicle: only vehicles are detected (all types) any: vehicles and pedestrians are detected 000 (min) 287 (max) factory default: 000 000 (min) 240 (max) factory default: 240 000 (min) 287 (max) factory default: 080 000 (min) 287 (max) factory default: 000 000 (min) 240 (max) factory default: 240 000 (min) 287 (max) factory default: 06 rev 00%+ vehicle By activating the filed inversion, the field learned during the walk teach-in will be inverted. min 2 vehicle: only vehicles are detected (all types) any: vehicles and pedestrians are detected vehicle By activating the filed inversion, the field learned during the walk teach-in will be inverted. min 2 4" 2 min 3 2 min 3 6" 5 min 4 5 min 4 8" 0 min 0 min 30 min 30 min 60 min 60 min 20 min 20 min any any infinite infinite Depending on mounting height, angles, and other installation factors, some immties might exclude conformity with EN 2445. An object < 6" is not detected. An object > 6" is detected during0 min (adjustable). An object > 6" is detected infinitely (not adjustable). InvertField no yes By activating the filed inversion, the field learned during the walk teach-in will be inverted. 75.596.02 LZR-WIDESCAN 20802 Page 9 of 5

OPTIONAL REMOTE CONTROL SETTINGS (cont.) 2 3 A... MOTION Direction (see next pg for details) 0 2 3 4 5 6 7 8 9 bi 00% rev 00%+ BIDIRECTIONAL UNI 00% UNI REV bidirectional detection approaching and going away directional detection approaching within the width of the max. field directional detection reverse going away UNI 00% + UNIDIRECTIONAL directional detection approaching within the width of max. field + m of bidirectional detection in front of door directional detection approaching in any direction (distance between object and sensor decreases) OPTIONAL LCD CONTROL SETTINGS Additional parameters are also available via LCD menus. These cannot be accessed/programmed via remote control. Such functions are listed as follows (but not limited to): LCD PATH PARAMETER OPTIONS (default = bold/underlined) MAIN IN OUT > MORE [parameter] MAIN QUICK START > MORE [parameter] OUTPUT LOGIC OUTPUT HOLDTIME OUTPUT TEST OUTPUT2 LOGIC OUTPUT2 HOLDTIME OUTPUT2 TEST RELAY LOGIC RELAY HOLDTIME RELAY TEST HEATING NC, NO 00 ms, s, 3 s, 5 s, 0 s, 30 s, 60 s, 5 min, 0 min, 20 min OFF, ON NC, NO 00 ms, s, 3 s, 5 s, 0 s, 30 s, 60 s, 5 min, 0 min, 20 min OFF, ON PASSIVE NC/NO, ACTIVE NO/NC 00 ms, s, 3 s, 5 s, 0 s, 30 s, 60 s, 5 min, 0 min, 20 min OFF, ON OFF, ECO, AUTO Page 0 of 5 75.596.02 LZR-WIDESCAN 20802

2 3 A TEACH-IN: PULL CORD When an object is detected in the virtual "Pull-Cord" zone for at least 3 seconds, the door will open. In order to use this function: -- make sure the corresponding wires are connected to the door activation input (out by default) -- make sure the output or relay function is set to Motion or Pull-Cord (factory value) or Pull-Cord... 5 s x 5. Launch a "Pull-Cord" teach-in by remote control. 2. Go to the position where you want to activate the door by a virtual pull-cord. 3. The learning process starts. The sensor confirms that a person has been seen. Do not move untill the LED stops flashing! If nobody is seen after minute, the sensor flashes orange 5x (see TROUBLESHOOTING). If is detected, the sensor starts a new learning process. 4. The teach-in ends successfully. If not, refer to the TROUBLESHOOTING section on page 4. To delete the virtual "Pull-Cord" zone, simply relaunch a "Pull-Cord" teach-in (step ) without standing in the scanning zone. After minute, the sensor flashes 5x orange. Push unlock + lock ( )to exit the adjustment mode: HEIGHT TRIGGER By default, all objects higher than 7 6" will activate the Height Trigger. This function can also be used to partially open the door depending on the height of the object. The Height Trigger function can be used for a door control which has a partial-open input. a. Assign Output, Output 2, or Relay to Motion + Height. b. Connect to the Full-Open input on the door control. c. Set the field to any object and assign the to an output. d. Connect to the Partial-Open input of the door control. lower than 7 6" higher than 7 6" The door opens partially. The door opens completely. The factory default for this parameter is 7 6", but additional parameters are available by accessing the "Height Limit" parameter in the "OTHERS" menu, via LCD only customization of this parameter is unavailable via remote control. Follow the LCD menu path to make changes: MAIN OTHERS HEIGHT LIMIT 68.9, 78.7, 88.6, 98.4, 08.4, 8., 27.9, 33.3, 57.5 (factory default is bold/underlined) NOTE: Each of these available parameters is higher than inches. I.e. If the parameter 08.4 is chosen, the sensor will detect objects with a MINIMUM height of 08.4 inches. 75.596.02 LZR-WIDESCAN 20802 Page of 5

SPEED TRIGGER By default, all objects that move slower than 3 mph will activate the output. This function helps to trigger the door open in the case of late / slow-moving objects in close proximity to the door. The factory default for this parameter is less than 3 mph, but additional parameters are available by accessing the "Speed Limit" parameter in the "OTHERS" menu, via LCD only customization of this parameter is unavailable via remote control. Follow the LCD menu path to make changes: MAIN OTHERS SPEED LIMIT 3., 6.2, 9.3, 2.4, 5.5, 8.6, 2.7, 24.8, 28, 3, (factory default is bold/underlined) NOTE: Each of these available parameters is slower than mph. I.e. If the parameter 5.5 is chosen, the sensor will detect objects moving at speeds SLOWER than 5.5 mph. OUTPUT FUNCTIONS There are 7 detection functions (3 main functions and 4 additional opening functions): MAIN ADDITIONAL Motion detection of moving object in field = door opens Motion + detection of other type of moving object in field = door opens Presence detection of object in presence field = door does not close Pull-Cord detection of object in learned zone = door opens Safety detection of everything in safety field - door does not close Speed Trigger detection of object with max. speed (< 3 mph) = door opens Height Trigger detection of object with min. height (> 7 6") = door opens Two additional detection functions are also available: Motion, Pull Cord, or Safety Motion, Pull Cord, or Presence Any of these functions are available to be assigned to all of the three outputs. Always enter 3 digits, for each output: st digit refers to output 2 nd digit refers to output 2 3 rd digit refers to the relay function Examples: output : output 2: relay: output : output 2: relay: If you do not want to change the setting of an output, select 0. Motion or Pull-Cord or Safety no change (Presence) Motion + and Speed Motion or Pull-Cord or Presence no change (Presence) Pull-Cord 0 2 3 4 5 6 7 8 9 Out Function Out 2 Function Relay Function no change no change no change + presence safety + presence safety + presence safety + speed + speed + speed + height + height + height safety safety safety presence presence presence Page 2 of 5 75.596.02 LZR-WIDESCAN 20802

TEACH-IN: WALK You can also reshape one or more detection fields by walking around the requested field. It is possible to cut into the existing field from the border or to extract a field within the detection field. Make sure the field is larger than desired. The existing field size can be reduced and adapted, but cannot exceed the configured size. LAUNCH A WALK TEACH-IN Choose the desired field(s) by LCD or remote control: Quick Start > TeachIn > Walk All: Motion, Presence, and Safety field LEFT LED Quick Start > TeachIn > Walk Motion: Motion field only... Quick Start > TeachIn > Walk Presence: Presence field only... Quick Start > TeachIn > Walk Safety: Safety field only.. Ex.: Quick Start In-Out QS TeachIn Presettings TeachIn Walk Motion 2 GO TO STARTING POINT Step away from the detection field and remove any objects (ladder, tools etc). Go to the starting position of your detection field (see st picture below). The delay after which the teach-in is launched is 60 seconds by LCD (adjustable to 30 or 20 sec via Quick Start > More > TeachInDelay). The delay by remote control is 5 seconds. 60 SEC / 5 SEC 3 DO NOT MOVE The sensor learns its background as long as the LED flashes red-green. 4 START WALKING When LED flashes green, hold one arm in the air and slowly start walking the trace of the desired field shape. Then, stop and wait until LED stops flashing. START outside of the max. detection field. CUT-OUT STOP outside the max. detection field. Max field Walk field START anywhere in the max. detection field. ETRACT STOP close to the starting point. Max field Walk field The teach-in was either successful or not (see TROUBLESHOOTING). OR OR Using the remote control, you can add a trace of the field shape to all fields or one in particular. You can invert each detection field via LCD (Motion, Presence, Safety > More > Field inversion). Always verify the field dimensions via the Field Display option on the LCD screen (Diagnostics > FieldDisplay). To delete a trace, simply relaunch a walk teach-in without walking in the respective detection zone during 5 seconds. 75.596.02 LZR-WIDESCAN 20802 Page 3 of 5 5........

2 3 A TROUBLESHOOTING E E2 2 E: CPU- The sensor encounters an internal problem Replace sensor. E2: PWR The internal power supply is faulty Replace sensor E2: IN SUPPLY The power supply is too low or too high Verify power supply (Diagnostics > LCD). E2: TEMP The internal temperature is too low or too high Verify the sensor temperature (Diagnostics >LCD). Protect the sensor from direct exposure to heat or cold. E5 5 INSTALL The sensor requests a teach-in Launch teach-in after angle adjustment. All presence/safety outputs are activated. E5: FLATNESS Faulty teach-in Make sure that the teach-in zone is clear of objects and then launch install teach-in. E5: TILT Faulty teach-in due to tilt angle Adjust tilt angle (max. 5 > Diagnostics > LCD). Launch install teach-in. E5: AZIMUTH Faulty teach-in due to lateral angle Adjust lateral angle (max. 45 > Diagnostics > LCD). Launch install teach-in. E5: HEIGHT Faulty teach-in due to mounting height Adjust mounting height (max. 9 6, min. 6 6 ). Launch install teach-in. E6 E8 6 8 E5: TIME-OUT Faulty teach-in Relaunch install teach-in. Make sure that there is no detection during at least 5 seconds when LED starts flashing red/green. E6: FQ OUT Faulty sensor output Replace sensor. Slightly change your position and relaunch an install teach-in. E8:... Faulty detection engine If temperature is lower than -4 F, wait until the heating process is completed. If temperature is higher than -4 F, replace the sensor. ORANGLE LED is on LED and LCD display are off The sensor encounters a memory problem Incorrect wiring Replace sensor. Check wiring. Door does not react Service mode is activated Exit service mode (see page 9). Product does not react to remote control Sensor is password-protected Enter correct password. If you forgot the code, cut and restore power supply in order to access the sensor without entering a password during minute. Motion detection starts too late Negative angle is too large Reduce angle of the sensor. Page 4 of 5 75.596.02 LZR-WIDESCAN 20802

TECHNICAL SPECIFICATIONS PLEASE KEEP FOR FURTHER USE DESIGNED FOR COLOR PRINTING Original Instructions BEA 75.596.02 LZR-WIDESCAN 20802 Technology Detection mode Max. detection field Thickness of first curtain LASER scanner, time-of-flight measurement (7 laser curtains) Motion and presence Typ. mounting height 6 6 9 6 Min. reflectivity factor Typ. min. object size Width:.2 x mounting height Depth:.2 x mounting height 3 4 inch per 3 feet of mounting height Testbody 27 2 3 4 7 3 4 Emission characteristics > 2 % (of floor and object) (measured at max. 9 6 in safety field) 6 @ 9 6 (in proportion to object distance) adjustable, depending on user settings IR LASER: Wavelength 905 nm, max. output pulse power 25 W, Class Visible LASER: Wavelength 650 nm, max. output CW power 3 mw, Class 3R Supply voltage 2 24 VAC ±0% 2 30 VDC ±0% @ sensor terminal Power consumption < 2.5 W (heating: off) < 5 W (heating: eco or auto) Response time Output Input LED signals Dimensions Material / Color Typ. 00 ms (max. 500 ms) 2 solid-state relays ( galvanic isolation, polarity free ) 30 VDC (max. switching voltage) 00 ma (max. switching current) - in switching mode: NO/NC - in frequency mode: pulsed signal (f= 00 Hz ±0%) electro-mechanic relay (galvanic isolation, polarity free) 42 VAC (max. switching voltage) 500 ma (max. switching current) 30 VDC (max. switching voltage) low < V high > 0 V (voltage threshold) 2 tri-colored LED: Output status / remote control response / error signals 7 3 4 (H) x 6 (W) x 4 (D) (approx.) PC/ASA / Black Rotation angles on bracket 45 to the right, 5 to the left ( lockable ) Tilt angles on bracket -0 5 Protection degree NEMA 4 / IP65 Temperature range -30 60 C Vibrations < 2 G Norm conformity EN 6000-6-2 EN 6000-6-3 EN 60950- EN 60825- EN ISO 3849- Pl d / CAT2 EN 6206 SIL 2 Specifications are subject to change without prior notice. All values measured in specific conditions. BEA INSTALLATION/SERVICE COMPLIANCE EPECTATIONS EN 6496- ESPE Type 2 EN 2978 EN 5058 BEA, the sensor manufacturer, cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor/device; therefore, BEA does not guarantee any use of the sensor outside of its intended purpose. BEA strongly recommends that installation and service technicians be AAADM-certified for pedestrian doors, IDA-certified for doors/gates, and factorytrained for the type of door/gate system. Installers and service personnel are responsible for executing a risk assessment following each installation/service performed, ensuring that the sensor system installation is compliant with local, national, and international regulations, codes, and standards. Once installation or service work is complete, a safety inspection of the door/gate shall be performed per the door/gate manufacturer recommendations and/or per AAADM/ANSI/DASMA guidelines (where applicable) for best industry practices. Safety inspections must be performed during each service call examples of these safety inspections can be found on an AAADM safety information label (e.g. ANSI/DASMA 02, ANSI/DASMA 07, UL 325). Verify that all appropriate industry signage and warning labels are in place. Tech Support: -800-407-4545 Customer Service: -800-523-2462 General Tech Questions: Tech_Services@beainc.com Tech Docs: www.beainc.com 75.596.02 LZR-WIDESCAN 20802 Page 5 of 5