Pocket Dilution Cooler

Similar documents
Concept of a Powerful Cryogen-Free Dilution Refrigerator with Separate 1K Stage

Development of a Dilution Refrigerator for Low-Temperature Microgravity Experiments

A CRYOGENIC TEST STATION FOR SUBCOOLING HELIUM HEAT EXCHANGERS FOR LHC

The dilution process. 4K flange. Still. Heat exchangers. Mixing chamber

CHASE RESEARCH CRYOGENICS Ltd. World Leaders in sub-kelvin cryogenics

Development of the Closed-Cycle Dilution Refrigerator for Space Applications

Requirements for Repair of a Miniature Liquid Helium-3 Refrigerator

Remote Helium Cooling Loops for Laboratory Applications

Available online at ScienceDirect. Physics Procedia 67 (2015 )

A Microcryostat for Refrigeration at 1.8 K

Numerical study of heat pipe application in heat recovery systems

10 K Airborne Cryocooler and

Scientific Principals and Analytical Model. Charcoal Cooler. Lisa Crofoot MECH 425, Queens University

Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to Achieve Optimal Closed DOAS Operation

S.A. Klein and G.F. Nellis Cambridge University Press, 2011

Experimental Investigation of a Multi Effect Membrane Based Regenerator for High Concentration Aqueous LiCL Solution as Desiccant

(Refer Slide Time: 00:00:40 min)

Thermal performances of a meter-scale cryogenic pulsating heat pipe.

Effect of Heat Exchanger Configuration on the Performance of Joule-Thomson Refrigerators

Performance test of a helium refrigerator for the cryogenic hydrogen system in J-PARC

AIR CONDITIONING. Carrier Corporation 2002 Cat. No

UHV Flow Cryostats. Ultra High Vacuum Flow cry stats CRYO INDUSTRIES

Thermal Performance of a Loop Thermosyphon

International Journal of Engineering Research (IJOER) [Vol-1, Issue-3, June- 2015]

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger

FS 231: Final Exam (5-6-05) Part A (Closed Book): 60 points

Performance Assessment of Water Cooled Condenser Refrigeration System

Hot Reservoir Stainless-Methanol Variable Conductance Heat Pipes for Constant Evaporator Temperature in Varying Ambient Conditions

Combination unit to support instruction in Thermodunamics, Fluid Mechanics, and Heat Transfer

Novel process for the drying of sugar cubes applying microwave technology

Oxyvap Evaporative Cooling Applications

Application Note Heat Transfer Design Team 7 Compact Inverter Jack Grundemann

PRESSURE-ENTHALPY CHARTS AND THEIR USE By: Dr. Ralph C. Downing E.I. du Pont de Nemours & Co., Inc. Freon Products Division

MECHANICAL ENGINEERING ME.2017 FUNDAMENTAL OF REFRIGERATION AND AIR CONDITIONING. Sample Questions and Answers

arxiv: v2 [astro-ph.im] 20 Mar 2013

TWO- AND THREE-STAGE CASCADE REFRIGERATION SYSTEM By: Paul B. Reed

Properties of a two stage adiabatic demagnetization refrigerator

Cryogenics for Neutral Beam Injector System

Thermodynamics: Homework A Set 7 Jennifer West (2004)

I. C O N T E N T S T A N D A R D S

NOVEL COMPACT SORPTION GENERATORS FOR HEAT PUMP APPLICATIONS

EXPLORING POSSIBILITIES WITH THE DEVELOPMENT OF THE LOOP HEAT PIPE TECHNOLOGY. Roger R. Riehl

Development of a Novel Structure Rotary Compressor for Separate Sensible and Latent Cooling Air-Conditioning System

A continuous dry 300 mk cooler for THz sensing applications

SAMPLE STUDY MATERIAL

Heat Recovery Units. Heat Recovery 1

The superconducting TF magnetic system of Tore Supra

IJIRST International Journal for Innovative Research in Science & Technology Volume 1 Issue 12 May 2015 ISSN (online):

Convection is the heat transfer by the macroscopic movement of a fluid, such as a car's engine kept cool by the water in the cooling system.

Cooling the Data Center

Appendix A. Glossary of Common Terms

COMPARING AIR COOLER RATINGS PART 1: Not All Rating Methods are Created Equal

Passive cooling of telecommunication outdoor cabinets for mobile base station

15. Heat Pipes in Electronics (1)

LEIDEN CRYOGENICS BV

Comparison Simulation between Ventilation and Recirculation of Solar Desiccant Cooling System by TRNSYS in Hot and Humid Area

Experimental Investigation of a Hybrid Evacuated Tube Solar Collector

A n hybrid liquid nitrogen system for the cooling. of the ESO O mega C A M detector

Measured Performance of Four New 18 K Helium Refrigerators for the LHC Cryogenic System

CTI Sponsored Educational Program

Development of Helium-3 Compressors and Integration Test of Closed-Cycle Dilution Refrigerator System

For an ideal gas mixture, Dalton s law states that the sum of the partial pressures of the individual components is equal to the total pressure.

Experimental Research On Gas Injection High Temperature Heat Pump With An Economizer

Heat Exchanger. The purpose may be either to remove heat from a fluid or to add heat to a fluid.

Process Simulation and Optimization of Cryogenic Operations Using Multi-Stream Brazed Aluminum Exchangers

A CEILING CONDENSING UNIT WITH PELTIER ELEMENTS FOR DRYING AND COOLING

Use this Construction/HVAC Glossary to answer the questions below.

LECTURE-18 Vapour Absorption Refrigeration System

Mechanical Engineering Department Sheet (1)

Air Liquide Advanced Technologies Division Sassenage, 38360, France

A THIN GOLD COATED HYDROGEN HEAT PIPE -CRYOGENIC TARGET FOR EXTERNAL EXPERIMENTS AT COSY

EFFECT OF PAG OIL CIRCULATION RATE ON THE HEAT TRANSFER PERFORMANCE OF AIR-COOLED HEAT EXCHANGER IN CARBON DIOXIDE HEAT PUMP SYSTEM

HOW IT RELATES TO PERFORMANCE IN REFRIGERATED COMPRESSED AIR DRYERS

A 2 K Active Magnetic Regenerative Refrigeration System for Remote Cooling

AND AIR-CONDITIONING. Dr Ali Jawarneh Department of Mechanical Engineering Hashemite University

Operation of a Two-Phase Reverse Loop Thermosyphon

LEAKAGE MONITORING OF SEAL PLUG FOR INDIAN PRESSURIZED HEAVY WATER REACTOR BY PSYCHOMETRICS ANALYSIS METHOD

2. HEAT EXCHANGERS MESA

4th IIR International Conference on Thermophysical Properties and Transfer Processes of Refrigerants 2013

ω = (1) Kirby S. Chapman Ph.D.

Low Temperature Separation Systems. Separation Process

EVALUATING LOOP HEAT PIPE PERFORMANCE IMPROVEMENT USING CIRCUMFERENTIAL GROOVES. Nadjara dos Santos, Roger R. Riehl

Design and Operation of a Cryogenic Nitrogen Pulsating Heat Pipe

L14 ENVIRONMENTAL CONTROL TECHNICAL DATA

The Innovative Green Technology for Refrigerators Development of Innovative Linear Compressor

Application of two hybrid control methods of expansion valves and vapor injected compression to heat pumps

Refrigeration Systems and Accessories

Cryopumps, Cryogenics

COOLING OF DESKTOP COMPUTER USING HEAT PIPES

0Effect of Fin on the Performance Characteristics of Close and Open Loop Pulsating Heat Pipe

Pressure drop analysis of evaporator using refrigerants R-22, R-404A and R-407C

PERFORMANCE OF A VERY LOW TEMPERATURE REFRIGERATION SYSTEM OPERATING WITH NATURAL FLUIDS

Fast Cycle Water Vapor Cryopump

EVAPORATION NEEDS ENERGY

HEAT PIPES

Chapter 2.3: Steam System

BASIC HEAT PUMP THEORY By: Lloyd A. Mullen By: Lloyd G. Williams Service Department, York Division, Borg-Warner Corporation

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

Thermal management architectures for rack based electronics systems. Sukhvinder Kang, David Miller Aavid Thermalloy, Concord NH, USA

How Ground Source Heat Pumps Work

Transcription:

Pocket Dilution Cooler T. Prouvé, N. Luchier, L. Duband CEA/DSM/INAC/SBT Grenoble, 38054 Cedex 9, France ABSTRACT We have developed a compact, self-contained dilution cooler that can be operated from a 2.5 K or lower heat sink. The system is made of a helium sorption cooler coupled to a closed loop in which the helium mixture flows. The dilution loop operates continuously and is only limited by the autonomy of the sorption unit which needs to be recycled on a regular basis. This first prototype has been designed to provide temperatures below 100 mk for a typical days work. The system can be scaled up within certain limits. Temperatures down to 57 mk and a typical cooling power of 7 µw at 100 mk have already been achieved. We expect to reach a nominal useful power of 2.5 µw at 50 mk with mixing chamber improvements. DILUTION OPERATION AND SELF CONTAINED DESIGN For a mixture of 3 He and 4 He under 850 mk and depending on the 3 He concentration, there is a phase separation between a dilute phase of superfluid 4 He with saturated 3 He, and a concentrated phase of pure 3 He. By decreasing the 3 He concentration of the dilute phase, the equilibrium between the two phases is out of balance and a 3 He dilution flow occurs from the concentrated phase to the dilute one. Due to the higher enthalpy of dilute 3 He, dilution of concentrated 3 He is an endothermic process. By using Radebaugh's 1 works on 3 He/ 4 He mixture properties, Eq. (1) gives the cooling power of the mixing chamber according to the 3 He dilution flow (mole/s), T concentrate (K), and T dilute (K): Since the 1960s, dilution refrigerators have usually been used to achieve temperatures well below 100 mk. With large devices, cooling powers of several milliwatts at 100 mk can be provided, and temperatures as low as 2 mk have been achieved. 2 Nevertheless, those coolers are quite complicated to operate because of their room temperature 3 He circulation. They are costly, energy intensive, bulky, and not very reliable over time due to 3 He injection plugging, for instance. Based on an idea by London et al. 3, we propose a dilution refrigerator whose 3 He circulation is provided by a cryopump that condenses the 3 He vapors coming out of the still. The cryopump operates from a self-contained 3 He sorption cooler. Figure 1 provides a schematic of our system. In 1972 V.S. Edel man 4 built such a dilution refrigerator that was operated from a pumped 3 He bath. In the mixing chamber, concentrated and dilute phases coexist. 3 He is driven through a pipe to the still tank by the osmotic pressure gradient. Power applied to the still causes 3 He to evaporate and also sets the dilution flow. The distillation temperature is driven by the cryopump efficiency, (1) 497

498 Sub-Kelvin, magnetic, and novel refrigerators Charcoal Pump 4 He pumped bath connection Cryopump 3 He condenser Heater Thermal link Heat switch Still Heat Exchanger 3 He evaporator Mixing Chamber Figure 1. 3 He sorption cooler and dilution refrigerator mechanism diagram. which keeps a low pressure at a given flow rate. Liquefied 3 He at the cryopump temperature goes down in the injection pipe due to gravity. According to Eq. (1), low temperatures can be achieved if the concentrated phase is precooled before entering the mixing chamber. So the injection line features a counterflow heat exchanger cooled by the dilute phase. The dilution operation is gravity driven. That involves some specificity in the design. Cryopump, still, and mixing chamber locations are not trivial. In order to have an equal pressure between the two phases in the mixing chamber, the 3 He level of the concentrated phase injection must be rather high. Densities of 3 He and 4 He are indeed on the order of ½. For a compact design, this requires one to limit as much as possible the distance (height) between the mixing surface and the still. 3 He flow in the injection line produces pressure drops. With standard dilution refrigerators, pressure drops into very long counterflow heat exchangers are not a problem because 3 He roomtemperature pumps can easily produce the input pressure necessary to provide the dilution flow rate. With a cryopump, liquefied 3 He is just at its saturated vapor pressure, and thus pressure drops are only balanced by an increase of 3 He level in the injection line (hydrostatic pressure). In a compact design, it is necessary to use a low-impedance exchanger to provide the 3 He injection. If no attention is paid to these two special points, the dilution will not operate continuously; instead, all of the 3 He will be accumulated in the cryopump dead volume, and the mixing surface will be out of the mixing chamber. In our design, the heat exchanger is a flat spiral design that enables the still and the mixing chamber to be placed at approximately the same level. DILUTION DESIGN Our goal is to provide a net cooling power of 2.5 ìw at 50 mk assuming an additional 0.5 ìw heat loss. By using Eq. (1) we have reached a solution with a 15 ìmole/s dilution flow rate. The heat exchanger has a length of 1.5 m with a concentrated side made with CuNi 1.3 1.7 mm and dilute side made with CuNi 2 2.5mm. The average cryopump consumption 1 for a 15 ìmole/s dilution flow rate is almost 500 ìw. The pressure into the cryopump is equal to the vapor pressure of liquid condensed to the cold surface. The colder the liquid is, the lower the pressure is, and the better the distillation is. So, according to the condensation power and the Kapitza resistance between cryopump copper s body and liquid 3 He, we calculated an exchange surface of about 50 cm 2 to keep the T between the cryopump and the condensed liquid below 10 mk. The picture on the left of Figure 2 shows the cryopump with its

pocket Dilution cooler 499 Figure 2. LEFT: 3He Cryopump RIGHT: mixing chamber copper heat exchanger. fins to increase its surface area. The gap between the fins has been designed to avoid liquid accumulation due to capillary forces. The bottom of the mixing chamber is made of a massive copper heat exchanger. To increase the exchange surface, numerous needlelike fins have been made using an electro-discharge machining technique (see Figure 2). The mixing chamber, with an internal diameter of 1.6 cm and a height of 2 cm, features a 30 cm2 surface area. This large surface area is enabling for cooldown, but not to achieve very low temperatures and to supply large cooling power. Figure 3 displays the mixing chamber temperature as a function of exchange surface area and dilute phase temperature. Note that for a 2.5 ìw heat-load temperature our present design leads to a mixing chamber at 75 mk when the fluid is at 50 mk. Work is in progress to develop a silversintered exchanger to increase the surface to over 1 m2 for the same mixing chamber volume. DEDICATED 3He SORPTION COOLER In order to provide the necessary cooling power at 300 mk for the dilution unit, we have developed a high cooling power 3He sorption cooler. The dilution refrigerator 3He flow efficiency depends on two parameters. First of all, there is the still efficiency. Table 1 gives the percentage of 4He/3He in the circulating vapors. The still temperature should not be over 650 or 700 mk. Circulating 4He is indeed a power waste and reduces the mixing chamber efficiency. Secondly, there is the 3He-cooled cryopump efficiency, which determines the operating time for a given dilution flow rate. This is determined by Figure 3. Kapitza boundary resistance effect calculations.

500 Sub-Kelvin, magnetic, and novel refrigerators Table 1. Comparative table of 4 He ratio circulated versus still temperature with mixing chamber at 50 mk. Table 2. Comparative table of 3 He flow between sorption cooler and dilution refrigerator with a mixing chamber at 50mK. the ratio between the 3 He vapor condensation rate in the dilution loop, and the sorption cooler 3 He evaporation rate. The colder the 3 He vapor is coming out of the still, the lower will be the energetic cost to condense it. However, to have a cold still, the 3 He sorption cooler has to be even colder. The 3 He latent heat decreases with temperature, so a lower temperature leads to a reduction in the operating time. Table 2 gives the ratio between these two 3 He flows for various temperatures. Thus, the warmer the still is, the lower the cryopump efficiency will be. Between 500 and 800 mk, about a 10% increase in operating time can be gained. So, the 3 He sorption cooler must be powerful enough at the nominal dilution flow rate to provide the lowest temperature. The left side of Figure 4 shows a diagram of 3 He and still vapor pressures with a mixing chamber at 50 mk. Note that the sorption cooler should operate below 450 mk to have a still temperature under 650 mk, the temperature required to obtain an efficient 3 He flow in the dilution refrigerator. The cooler was designed to be able to extract about 500 µw of net heat lift at a temperature below 400 mk. This power corresponds to a 15 ìmole/s dilution flow rate. 1 Large cooling-power sorption coolers have only recently been developed in our laboratory. The first large unit we designed and tested is a 16L STP unit with a 20 mm internal diameter pumping line. This cooler can be operated from a 2.5 K or lower heat sink to condense the 3 He. With a cold source at 1.5 K, the parasitic heat load is almost 80 µw, but then again, this unit has been designed to operate with very large cooling powers. With a 500 µw applied load, it operates 7 hours and fulfills our initial objective of experiments on a daily basis. The measured cooling power curve is given on the right of Figure 4. The ultimate temperature is near 240 mk, and a temperature of 346 mk is Figure 4. LEFT: 3 He and still vapor pressures RIGHT: sorption cooler power curve

pocket Dilution cooler 501 reached for a cooling power of 500 µw. It can be seen on this curve that this sorption cooler can supply temperatures lower than 450 mk for cooling powers up to 1 mw, which enables it to support large 3 He dilution flow rates. PRECOOLING AND DILUTION REFRIGERATOR EFFICIENCY The whole system (sorption cooler + dilution) has been tested on a 4 He pumped cryostat that provides a temperature of 1.5 K with an operating time of about a day. The 4 He coldplate is 30 cm in diameter and is surrounded by a first thermal shield at 1.5 K, and then by a second one at 77 K. Because the sorption cooler is charged with helium and permanently sealed, the internal pressure during most of the cooldown process from ambient temperature is fairly high. As a result convective effects occur in the pumping line and provide an efficient thermal conductance. However, the mixing chamber can not be cooled through the dilution tubing because the thermosiphon effect is not efficient at all. Thus, a thermal switch has been added between the cryopump (thermally linked to the 3 He cooler through a strong cooper link) and the mixing chamber. During dilution operation, this thermal switch is OFF and leads to a calculated parasitic head load of about 0.4 ìw. Our dilution prototype is not designed to contain the 3 He/ 4 He mixture at room temperature, and we are using a 5 L storage tank out of the cryostat. Pressure is about 1.5 bar with 25% of 3 He. The filling pipe is connected to a 1.5 K cold trap made of stacked copper meshes. Then, the line reaches the dilution on the still using a length of 0.2 mm diameter capillary that limits the superfluid flow, acting just like a diaphragm. We use Lakeshore thermometers with a RuO 2 20 mk on the mixing chamber. Heaters on the still and mixing chamber are 402 Ω glass resistors. A heater and a thermometer are placed on the 3 He injection capillary between the heat exchanger and the mixing chamber. The heater enables us to measure the gross cooling power in the liquid, and the thermometer enables us to measure the counterflow heat exchanger efficiency. Figure 5 gives the temperature cooling diagrams. During nitrogen and helium precooling, the sorption pump is kept hot to maintain some internal pressure and consequently convective effect. The Figure 5. LEFT: LN 2 and 4 He precooling RIGHT: Dilution cooling 400 mk-55 mk

502 Sub-Kelvin, magnetic, and novel refrigerators Figure 6. LEFT: mixing chamber power curve RIGHT: Kapitza calculation heat switch keeps the mixing chamber close to the dilution cryopump temperature. After 5 hours the bath can be pumped. When the cryostat flange is at 1.5 K, the charcoal pump is cooled. The large sorption pumping line enables an efficient cooling of the dilution refrigerator to 400 mk in 2 hours. At this temperature the thermal switch between the cryopump and the mixing chamber is turned OFF while 400 µw are applied 1 to the still in order to achieve a 15 µmole/s flow rate. The cryopump temperature increases to 380 mk and the still goes to 520 mk. The strong thermal link between the sorption 3 He evaporator and the cryopump limits the temperature difference to 20 mk. The 3 He evaporator at 360 mk takes a heat load of 500 µw (power curve on Figure 4) which gives 1 a flow rate of 15.6 µmole/s. Using the vapor pressures presented in Figure 6, we note that, with a still at 520 mk, the cryopump is very efficient, and the still is well supplied with 3 He. After 2 hours, the mixing chamber reaches temperatures lower than 100 mk. With a 15 µmole/s flow rate, the operating time is then 3 hours. REMARK: During the dilution cooldown phase, the mixing chamber initially warms up instead of cooling down. We explain this effect by the fact that during the precooling, the concentrate phase is above the mixture, in the top of the still. As power is applied to the still, the dilution does not start immediately because pure 3 He in the still has to be evaporated before the distillation of the dilute phase can be initiated. POWER CURVE AND EXPECTATIONS The mixing chamber power curve is given on the left of Figure 6. With 400 µw applied to the still, the mixing chamber achieves an ultimate temperature of almost 57 mk and a cooling power of 7 µw at 100 mk. We notice that the power curve slope is proportional to T 2, in good agreement with Eq. (1). We measured the temperature of the 3 He coming into the mixing chamber. This value was about 90 mk once the ultimate temperature was reached. According to Eq. (1), we should have achieved an ultimate temperature of almost 33 mk without any heat load, and a temperature of 38 mk with 0.5 µw (heat switch, tubing, and wires heat loads) and a 15 µmole/s flow rate.

pocket Dilution cooler 503 To analyze the performance, we have represented the power curve as a function of the squared temperature (see Figure 6). We have added on the same diagram a virtual power curve on which the Kapitza boundary resistance between dilute phase and mixing chamber copper body has been subtracted out. The linear fit enables one to calculate a dilution flow rate of 15.9 µmole/s with a heat load of 1.3 µw. These results are in agreement with the data that can be obtained based on the flow rate estimated through the cryopump heat load. The heat load is a bit high, but it could come from the cryostat background heat load. On this curve a power of almost 2.3 µw at 50 mk can be achieved and corresponds to our expectations. With a 10 µw heat load applied on the 3 He injection capillary we can compare our Kapitza resistance estimation. We measured 116 mk on the mixing chamber copper body and 97 mk with the power applied to the liquid through the 3 He injection capillary. These results agree with our estimation to within some mk. CONCLUSION We have developed and tested a compact dilution refrigerator using a cryogenic 3 He circulation of 15 µmole/s in order to reach a net cooling power of 2.5 ìw at 50 mk. Precooling of the dilution unit is achieved by a 3 He sorption cooler that can be operated from a 2.5 K or lower heat sink. The 15 µmole/s flow rate is obtained for a precooling temperature of only 520 mk. Higher flow rates can be generated if necessary. At the nominal flow rate, the ultimate temperature is 57 mk and a power of 7 µw at 100 mk has already been achieved. As expected, the Kapitza effect limits the ultimate temperature and cooling power. We are currently manufacturing a silver-sintered heat exchanger which will reduce significantly the temperature gap between the dilute phase and the mixing chamber copper body. In this case, as we have shown, powers around 2.3 µw at 50 mk should be achievable. With a cooling time of 2 hours, the current operating time at low temperature is 3 hours. It could be increased by using a larger 3 He sorption cooler or could even be made continuous by using two sorption coolers in parallel. Of course this autonomy is also directly linked to the net heat lift of the dilution loop; 7 µw at 100 mk is a significant performance. The system is gravity driven, and thus cannot be used for a space application. Nevertheless, such compact dilution refrigerator could be used to test detectors on ground applications or as a cooling solution on board balloon flown experiments. REFERENCES 1. Radebaugh, R., NBS technical note 362, 1967. 2. G. Frossati, et al., Proceedings of the Ultralow Temperatures Symposium, Hakone, Japan, 1977. 3. H. London & Al, Osmotic pressure of 3 He in liquide 4 He, with proposals for a refrigerator to work below 1K, Physical Review, v.128, n.5, 1962. 4. V.S. Edel man, A dilution refrigerator with condensation pump, Cryogenics, 1972.