FTA200-A REMOTE ALARM PANEL

Similar documents
FTA550 JOCKEY PUMP CONTROLLERS

FTA550F JOCKEY PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

WITH POWER TRANSFER SWITCH STANDARD SUBMITTAL PACKAGE

Remote Alarm Panels Features

Variable Frequency Drive SERIES MP800 VFD

Across-the-Line SERIES MP300 Combined Manual and Automatic

Liebert. Liqui-tect Leak Detection and Reporting Comprehensive Detection of Water Based Leaks in Critical Spaces

SECTION FIRE PUMP AND CONTROLS

Soft Start Series MP700 Solid State, Reduced Voltage

University of Houston Master Construction Specifications Insert Project Name SECTION FIRE PROTECTION PUMPS PART 1 - GENERAL

Model APD. Remote alarm panel for diesel motor driven fire pump. Drawing Submittal Package

CALL FOR TENDER - MUNICIPALITY OF THE DISTRICT OF CLARE LITTLE BROOK, N.S.

1.1 REFERENCES.1 American National Standards Institute/National Fire Protection Association (ANSI/NFPA).1 ANSI/NFPA 20, Centrifugal Fire Pumps.

Liebert PPC Second Generation Power Distribution Cabinet

DIESEL Engine Fire Pump Controllers Features

PROJECT: CUSTOMER: ENGINEER: DRAWING CONTENTS: WIRING

EG Controls. SLIMVIEW 120 VOLT FLOAT SERIES DUPLEX PUMP CONTROL PANEL SPECIFICATION for CITY OF E G

EATON DFDAP-M / FDAP-M Remote Alarm Panels

ACHIEVING ENERGY-EFFICIENT DATA CENTER COOLING: DOES REDUCING FAN SPEED ALWAYS RESULT IN ENERGY SAVINGS?

LIEBERT LIQUI-TECT 460 KIT ZONE LEAK-DETECTION SENSOR WITH CABLE

Linear Heat Detection Engineering Specifications

Model VPS Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass

Project: Customer: Engineer: Pump Manufacturer: Model GPY + GPU. with Automatic Power Transfer Switch

Model VPS + VPU Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass with Automatic Power Transfer Switch

Specification/ Data Sheet

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 21 Fire Suppression 3000 Fire Pumps

SECTION Fire Pumps

Liebert CW kW. Chilled Water Cooled Precision Air Conditioning For Data Centers. Precision Cooling For Business-Critical Continuity

Drawing Submittal Package

DONALD H. BERG, ARCHITECT

Drawing Submittal Package

Liebert Mini-Mate2 1 To 8 Tons

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

FDF Foam Pump Controllers Features

SECTION WET-PIPE SPRINKLER SYSTEMS EASY RISER CHECK VALVE

DIESEL Engine Fire Pump Controllers Features

Gas Safety Products. Installation, operating and maintenance. Merlin CO2 Monitor 2800PPM. Merlin CO2 Monitor 2800ppm. American Gas Safety LLC 1

OTFAMU Fresh Air Make Up System For Chilled Water OPERATOR S MANUAL. Technicold Marine Systems

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS

Booster Power Supply Manual

GLOW WIRE TESTING FOR THE APPLIANCE INDUSTRY

GLOW WIRE TESTING FOR THE APPLIANCE INDUSTRY

Model A1600 Series Annunciator

P.C. Simonton & Associates, Inc. Consulting Engineers. Paul C. Simonton

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

LD1000 ARCHITECT AND ENGINEER SPECIFICATIONS. RLE TECHNOLOGIES Rev

Liebert Mini-Mate2 1 To 8 Tons

IEC Lighting Contactor Specifications

Conventional Releasing Control Panel

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

SECTION COMMERCIAL DOOR OPERATORS OVERHEAD RSX FIRE DOOR OPERATOR

BULLETIN 600 SINGLE PHASE

Commercial and Light Industrial Fire Alarm Control Panel

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL G SERIES DRY VALVE

Liebert. Universal Monitor Monitoring, Control And Remote Communications For Critical Applications

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL F SERIES DRY VALVE

T125-E. Electric Fan Coil Thermostat. Product Bulletin. Operation. Appearance. Installation, Service and Maintenance

A. American National Standards Institute (ANSI): Establishes requirements applicable to certifying direct gas-fired heaters.

- Four (4) Fused Outputs - Four (4) PTC Outputs. - Eight (8) Fused Outputs - Eight (8) PTC Outputs

TECHNICAL BROCHURE BCALARM R4. Indoor and Outdoor Panels and Accessories

SETION EMERGENCY LIGHTING NATIONAL FIRE PROTECTION ASSOCIATION (NEPA) (2006) Life Safety Code, 2006 Edition

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

15900 HVAC INSTRUMENTATION AND CONTROLS

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

Liebert Mini-Mate2 1 To 8 Tons

University of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL

Technical Data. Approvals The 1-1/2 in. to 8 in. (DN40 to DN200) DV-5 Red-E Cabinets are UL Listed and C-UL Listed with the following system types:

Applying Performance-based Fire Alarm System Design Part 4

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

Liebert. CW kW Chilled Water Cooled Precision Air Conditioning For Data Centers

Gas Safety Products. Installation, operating and maintenance 11/26/2015. Merlin Gas Detectors. Merlin Gas Detectors. American Gas Safety LLC 1

B. Section Transfer Switches: Automatic transfer switch.

Technical Data. Approvals The 1-1/2 thru 8 inch (DN40 thru DN200) DV-5 Red-E Cabinets are UL Listed and C-UL Listed with the following system types:

I P. Tough Starters for Tough Environments. Explosion Proof Starter. Ready to Install, Completely Wired and Assembled

CONTENTS AUTOMATIC TRANSFER SWITCHES

Worldwide Contacts.

Technical Data Submittal Document

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

FULL RANGE EXPERTISE FIRE PUMPS FOR EVERY STANDARD

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

Moreno Valley Fire Department Fire Prevention Bureau. New and Existing Fire Alarm & Signaling Systems Guideline

AL600ULX Series. Power Supply/Charger. Installation Guide

Liebert. Mini-Mate2 1 To 8 Tons Overhead Precision Cooling And Humidity Control

AND ARCHITECT SPECIFICATIONS

Specifications. STEALTH Simplex, Wall Mount For SGV, OGP & OGV Grinder Pumps Control Panels & Accessories.

CM800 Emergency Call System

Cable Actuated Sensor Industrial User Scalable VDC Output

SECTION DOMESTIC WATER PRESSURE BOOSTING SYSTEMS (VFD) PART 1 - GENERAL 1.1 SUMMARY

Domestic. Pump Series CB and CBE Condensate Units SINGLE OR DUPLEX 1,000 THRU 140,000 SQ. FT. EDR-250 THRU 34,748 LB./HR.

- Four (4) Fused Outputs - Four (4) PTC Outputs. - Eight (8) Fused Outputs - Eight (8) PTC Outputs

DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL G1000 AND H1000 SERIES ANNUNCIATORS

VACUUM BREAKER MEDIUM VOLTAGE AUTOMATIC TRANSFER SWITCHES

SECTION ENCLOSED CONTROLLERS

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

PT9150 (Extended Range)

NEMA Manual. Starters. NEMA Manual Starters Contents

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs

Gas Safety Products. Installation, operating and maintenance 10/12/2017. Merlin Gas Detectors. Merlin Gas Detectors. American Gas Safety LLC 1

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH SHP-PRO CONTROL PANEL

Transcription:

FTA200-A REMOTE ALARM PANEL (FOR USE WITH ELECTRIC FIRE PUMP CONTROLLERS) STANDARD SUBMITTAL PACKAGE SBP200A

FTA200-A Remote Alarm Panels for Electric Fire Pump Controllers Product Description Type A - Type A panels provide audible and visible alarm indication for the following conditions: Supervisory Voltage Normal Pump Operating Pump Phase Failure Pump Phase Reversal Description Firetrol FTA200 alarm panels are designed to meet the NPFA 20 specifications requiring a remote alarm panel when the pump house or pump room is not constantly attended. The alarm panel must be installed in a location that is under supervision at all times. Approvals These alarm panels are listed by Underwriter s Laboratories, Inc., in accordance with UL508, Standard for Industrial Controls, certified by CSA, Standard for Industrial Control Equipment (cul) and approved by Factory Mutual. They are designed to meet or exceed the requirements of the approving authorities listed above as well as NFPA 20, Installation of Centrifugal Fire Pumps. Standard Features The following are included as standard with each controller: Construction - FTA200 alarm panels make use of printed circuit boards which provide reliable and trouble free service. The enclosures are NEMA Type 2 (IEC IP11) drip-proof for indoor wall mounting. The standard enclosure color is red. Mounted on the enclosure door are the pilot lights for visible alarm indication, the audible device for audible alarm indication, the SILENCE ALARM pushbutton and the PUSH-TO-TEST pushbutton. Each pilot light will illuminate to indicate its alarm condition and will remain lighted until the abnormal condition has been corrected. The audible alarm will sound when the alarm conditions occur and will continue to sound until the abnormal condition has been corrected or the SILENCE ALARM pushbutton has been pressed. Pressing the SILENCE ALARM pushbutton will silence the audible alarm but will not extinguish the pilot light. If another alarm condition occurs the audible alarm will again sound until silenced by the SILENCE ALARM pushbutton or until the abnormal condition has been corrected. The PUSH-TO-TEST pushbutton is supplied for manually testing the pilot lights, audible alarm and output circuits.

Modifications The following are available as modifications to the controllers: Special Enclosures -F NEMA Type 4X, 304 stainless (IEC IP66) -Y NEMA Type 1 (IEC IP10) Flush Mount, Painted Steel Consult Factory for other style enclosures. Additional Alarm Functions Each additional alarm function ordered will include a control relay and pilot light and will provide audible and visible alarm. There is no limit as to the number of additional alarm functions that can be supplied, however, enclosure size and weight may be affected. Consult the Factory for dimensions and shipping weights when ordering more than 2 additional alarms. Standard remote alarms may be ordered by using the Suffix Letters indicated for the corresponding alarm function on the Electric Fire Pump Controller. Alarm functions must exist in the controller to be ordered as remote alarms. Standard Remote Alarms -AM Pump Fail To Start -BY Pump Overload -EG Relief Valve Discharge -EJ Flow Meter On Non-Standard Remote Alarms -BT When ordering, specify the number of alarms required, the function of each and the nameplate marking of each. Substitute Amber for Red Pilot Lights -LA To meet local code requirements. Operation on 220-240 Volts -BA Panel is supplied as standard for operation on 110-120 volts. Pump Start Pushbutton -BS Mounted on enclosure door. Emerson Network Power - Global Headquarters 1050 Dearborn Drive Columbus, OH 43085 Tel +1 614 888 0246 EmersonNetworkPower.com ASCO Power Technologies - Firetrol Brand Products 111 Corning Road, Suite 120 Cary, NC 27518 Tel +1 1 460 5200 Fa +1 1 460 5250 Firetrol.com While every precaution has been taken to ensure accuracy and completeness herein, ASCO assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Information and specifications are subject to change without notice. Emerson, Consider It Solved., Emerson Network Power, the Emerson Network Power Logo, ASCO, Firetrol and the Firetrol Logo are trademarks or registered trademarks of Emerson Electric Co. All other names and logos referred to are trade names, trademarks, or registered trademarks of their respective owners. 2013 Emerson Electric Co. PD200-50 (A)