Remote alarm unit Art. Nr.:

Similar documents
Automatic switch attachment Standard Installation Instructions

Presence detector Komfort attachment Installation Instructions

System 2000 System 2000 automatic control switch Safety instructions. 2 Device components

Protecting you and your home

System 2000 Automatic control switch 2 Standard. 1 Safety instructions. 2 Device components. 3 Function. Order-No. : Operating instructions

Gira nurse call system Installation, start-up, operation. Gira emergency set

KNX module for smoke alarm devices Dual/VdS and Q-Label (Order no )

Operating Instructions. Room Temperature Controller 230/10 (4) A~ with NC contact and On/Off button

System 2000 System 2000 presence detector Comfort top unit. 1 Safety instructions. 2 Device components

System 3000 Motion detector top unit 1.10 m Standard, Motion detector top unit 2.20 m Standard

Detailed operating instructions

Detailed operating instructions

Contents 1 Set Up 2 Gateway information 3 Operation of the App 4 Troubleshooting Description of sensors. 1 Set Up. 1.1 Connect the Gateway

Intruder alarm system Operating Instructions

Version 1.03 January-2002 USER S MANUAL

alerting transmitter user guide other resources online at

Model 1104 Troubleshooting Guide

IDM4 CARAVAN ALARM. Operating instructions

1 Safety instructions. 2 Device components. Light Management Universal automatic switch m. Art.-No.: AS Operating instructions

MK9 series CarePhone. Installers Mauual

Alarm System SECURE AS 302

Dohse Aquaristik GmbH & Co. KG. T-Control Pro. Item no Status: 03/2013. Dohse Aquaristik GmbH & Co. KG

Master Code Arming Auto-Bypass Option - Home-Away Arming Entry Delay Off Arming

Mounting Instructions for Genius Hx

INSTRUCTION MANUAL PC255O

Intruder alarm panel Terxon MX Operating instructions

WLS900 Wireless Security System. Table of Contents. Your installing company is, Name: Address: Phone: Your monitoring station is, Name: Phone:

INSTRUCTION MANUAL PC255O

TYDOM 315. * _Rev.2* GSM domotics transmitter. 1. Presentation

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

User manual. ABB i-bus EIB. Zone Terminal MT/S Intelligent Installation System ABB STOTZ-KONTAKT

SFC-200 SERIES LED FIRE ALARM PANEL

testo 316-EX gas leak detector Instruction manual

Supervised Security System Owner's Guide

WS-9117U-IT Wireless 915 MHz Temperature Station. Instruction Manual

Operating instructions for the radio heat detector GS412

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

TABLE OF CONTENTS TABLE OF CONTENTS 1

ADVISOR CD User Manual. Software from version: V

FA-300 Series. LED Fire Alarm Control Panel. User Guide. FA-300 SERIES Fire Alarm Control Panel. FA-300 SERIES Fire Alarm Control Panel

Instructions for Use

User Manual. Alarm system: PhoneWatch TC

8 plus and16 plus. User s Guide * # ent. esc GALAXY 16+ V2.XX TUE 30 JUN. IU ZST 962 Issue 2. A u B u

2G & 3G GSM Wireless Beam Alarm

IMR IX176 Portable Gas Detector User Manual

2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge.

9 100% Recycled Paper

LCD and 16-Zone LED Keypads. User s Manual

½ CAUTION ½ DANGER. Getting to know the smoke detector. ARGUS Smoke Detector Single. Accessories. Operating instructions. For your safety A B C D E

Clock Radio AJ100. User manual

Accenta/Optima. User Guide. UK Security Panels. Servicing Organisation (Installer) name: Telephone Number: Date of Installation: Account Number:

636 and 646 Keypads. User s Manual

Protect anything, anywhere, anytime.

MG5000 MG5050 SP5500 SP6000 SP7000. User Guide

User Guide MG5000 MG5050 SP5500 SP6000 SP7000

PX-iP Operating Manual Gateway

2G & 3G GSM Portable PIR Alarm

Emergency call system for lifts: SafeLine SLMX2 Quick-guide

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460)

AM1 alarm module. RESOL AM1 alarm module * * Mounting Connection Function. Manual

Rev C May GE Interlogix. Part No: R. CareGard. User Guide

X64 Wireless Training

HILLS Series LED Code Pad User Manual

Installation & Operating Instructions

Contents. English. French. Spanish

Understanding the Code Pad lights...4. Code Pad tones...5. Fully arming the system On MODE...6. Fully arming the system - Quick Arm MODE...

/04.14_00. De Longhi Appliances via Seitz, Treviso Italia

PX-iP Operating Manual Gateway

5000 SERIES 8 ZONE INSTRUCTION MANUAL

PLEASE READ THE USER GUIDE CAREFULLY BEFORE INSTALLATION AND RETAIN FOR FUTURE USE.

1126 Series Ceiling Mount PIR Motion Detector

Wireless Keypads LKP(E)S8M Series

PRESENCE DETECTOR. PD-C360i/8 mini KNX PD-C360i/12 mini KNX / 13 7 REMOTE CONTROL PRESENCE DETECTOR

User Manual. with LED Keypad. Alarm Control Panel CA10 plus (software version 4.7) GDAŃSK. ca10pldu_e 07/03

Radio fire warning panel SRC 3000

Alarm Controller Fire and CO

Always Armed, Never Disarmed User Guide

OPERATING GUIDE FOR YOUR RP1054D KEYPAD

Dohse Aquaristik GmbH & Co. KG

Mounting instructions Genius Radio

Solution Ultima 862 Operators Manual ISSUE 1.10

QUICK CONSUMER REFERENCE GUIDE

Datasheet CALYPSO II R. Interlinkable smoke alarm device

LED Keypads D720 Series User s Guide

THE EVOLUTION OF CONTROL APP & CLOUD PORTAL

VIESMANN. Operating instructions VITODENS 050-W. for the system user. With constant temperature or weather-compensated control unit

English. Doro CareIP Mobile. User Guide

nbn setup guide Fibre to the Curb (FTTC) Connecting to the nbn broadband access network 1

P162B Radio PIR Motion Detector

Parameterisable compact fault annunciator with permanent display

Solution Ultima Series Operators Manual ISSUE 1.00

The Challenger Version 8 User Guide

Technical Manuals Online! A B C DEF GHI JKL POWER 9 0 COMMAND YZ. User's Guide

GT-1D. Residential/Tenant Station OPERATION MANUAL

Secure WANDERING INSTALLATION AND USAGE GUIDE

User s guide Personal radio trigger Erik 9100

WS-8300U 915 MHz Wireless Weather Station Instruction Manual

Sensero-868/915 AC, Sensero-868/915 AC Plus Nr , , ,

Instructions for Use

Register the Gateway via PC. Package Content. Gateway Installation. 1 x Gateway 1 x Voice Siren 1 x IP Camera*

Transcription:

Art. Nr.: 0814.. Product features Indication and transmission of alarms, malfunctions, battery status for all programmed alarm detectors Remote alarm programming of up to 20 alarm detectors Function monitoring of the programmed alarm detectors Visual and acoustic alarm indicators Simple to program and operate functions at each plug socket, irrespective of location It is possible to run more than one remote alarm units in parallel operation mode The radio alarm unit can be operated also after programming at otherplug sockets. Programming is preserved thereby. Operating principle The main purpose of the remote alarm unit is to receive and display alarm signals, from alarm detectors, that cannot be immediately detected at the alarm location. Alarm signals are transmitted by radio from the alarm detectors to the central remote alarm unit. This ensures that incidents such as fires, gas leaks or flooding in the basement are immediately made known in the upper floors of the building affected. It is possible to operate a few remote alarm units parallel. The modular design and flexible extension possibilities make it the ideal product to match your own particular safety requirements. Operating and indicating elements 21/00 Page: 1 of 7

Choice of location The remote alarm unit should be located within sight and earshot of the main part of the house. We recommend installation in one of the rooms most frequented by the people living in the house - normally the living room or main bedroom. The location (plug socket) can be also changed at any time, without starting a new programming procedure. Please observe a minimum distance of 1.5m between the remote alarm unit and the nearest alarm detector. This applies both to operation and during programming. Programming instructions The remote alarm unit does not require any complicated programming - as it automatically detects the configuration of the alarm system. Place all the alarm detectors that you wish to program on a table in front of you. Plug the remote alarm unit in a power socker near the table. Ensure that the testing area is at least 1.5m away from the remote alarm unit. Plug in each alarm detector and program all units successively. For parallel usage of remote alarm units! It is adviced to program the remote alarm units at the same time. In this case the described programming notes are relevant for all the remote alarm units. How to program an alarm detector Press programming button (ex: pencil or toothpick) red LED A flashes Press test button on alarm detector for 4 sec. (detector sounds) red LED A lights up red LED B flashes The red LED goes out after about ten seconds to indicate that the procedure is over. The following detector can now be programmed. Are all alarm detectors programmed please begin with the set up. 21/00 Page: 2 of 7

How to interrupt programming Press programming button red alarm LED flashes Press alarm reset button red alarm LED goes out This cancels the alarm detector programming procedure and resets the remote alarm unit. Double programming warning If an attempt is made to program an alarm detector that has already been programmed, this is indicated as follows: red alarm LED lights up and yellow sensor LED lights up After five seconds, the remote alarm unit resets automatically and the LED indicators go out. How to reset an alarm detector Press programming button red LED A flashes Press test button on alarm detector red LED A lights up red LED B flashes yellow LED C lights up Press alarm reset within five seconds red LED A goes out yellow LED C goes out This clears the programming of the alarm detector and resets the remote alarm unit. 21/00 Page: 3 of 7

Resetting all alarm detectors Press programming button red alarm LED flashes Press alarm reset button for about ten seconds, until all LED indicators light up Release alarm reset button all LED indicators go out once more This deletes all programmed data and returns the remote alarm unit to delivery status. Setting up the system After programming please install the alarm detectors at their location (see also assembly and operating instruction of the respective alarm detectors). Subsequently, you have to check the radio communication of all alarm units. Depending on the local occurence the assistance of a second person is recommended. 1. Put the radio alarm unit into a plug socket at their location. 2. Press approx. 4 sec. the test button at an alarm detector. If the radio transmission is in function, the warning tone at the remote alarm unit sounds and the red light emitting diode flashes. 3. Press the yellow reset button two times to quit the alarm 4. Repeat this test procedure with each alarm detector If you operate the remote alarm unit at different plug sockets you have to check the radio transmission there as well. If all tests of radio communication are done the system is ready to work. If the remote alarm unit does not give an alarm while pressing the test-button at an alarm detector, check the programming of the respective alarm detector (see also section Troubleshooting). Alarm identications Alarm signal alarm sounds red alarm LED flashes Press alarm reset button once red alarm LED lights up yellow sensor LED flashes Determine the location of the detector that has detected the alarm situation and take appropriate steps! Press alarm reset button once more all LED indicators go out 21/00 Page: 4 of 7

If the alarm is not acknowledged, it will stop sounding after 3 minutes red alarm LED lights up yellow sensor LED flashes a brief warning signal sounds every 40 seconds press the alarm reset button to clear the alarm The alarm will begin sounding once more if further alarm situations are detected at other detectors within the system status (above). If the alarm goes off Proceed as follows whenever the remote alarm unit registers an alarm situation: Acknowledge the alarm by pressing the alarm reset button once. Do not press the alarm reset button on the remote alarm unit again. The alarm will stop sounding. The relevant alarm detector indicates an acoustic and light signal. Determine the location of the detector or detectors that have detected the alarm situation. Check to determine the cause of the alarm and take appropriate action (extinguish the fire, call the emergency services, etc.), remembering at all times that human life takes precedence over material possessions. At last, press the alarm reset button a second time to cancel the alarm. Troubleshooting If the remote alarm unit registers an incident while it is displaying a fault message, the fault warning will be cancelled and the alarm will be activated. Sensor LED indicator: The yellow sensor LED lights up to indicate a malfunction in one of the programmed alarm detectors. A search must then be carried out to determine which alarm detector is working incorrectly. In order to aid this search, the relevant alarm detector will emit a brief alarm tone approximately every 40 seconds. (Further information is given in the relevant installation and operating instructions of the alarm detector.) A sensor fault can only be rectified by replacing the alarm detector. Radio LED indicator: There are two possible causes for a radio signal fault: There is a break in transmission. This may be due to the alarm detector being at the limit of its transmission range. If this is the case, unplug the alarm detector and test it at a different location, closer to the remote alarm unit. There is a fault in the alarm detector or radio module. Start by testing the alarm detector for correct functioning (press test button, check LED flashing frequency). If one or more alarm detectors are malfunctioning, check for correct programming. In order to do so, first clear the current program and reprogram each item at the remote alarm unit. If this does not rectify the fault, clear and reprogram all the alarm detectors. If the remote alarm unit radio fault indicator remains activated, the alarm detector(s) affected must be replaced. Alarm and sensor LED indicators: Up to 20 alarm detectors can be programmed to operate with a single remote alarm unit. The red alarm LED and yellow sensor LED will begin flashing if any attempt is made to program in more than 20 alarm detectors. Battery LED indicators A weak batterie of a programmed alarm detector will be displayed at the remote alarm unit. Exchange the battery at the relevant alarm detector (the alarm detector will display a flashing LED and a short warning tone in a pulse of a minute). 21/00 Page: 5 of 7

Care and maintenance This remote alarm unit is maintenance-free. Safety instructions In order to ensure a long and trouble-free service life, protect all parts of the system from dirt, dust, damp and impact damage. Radio transmission range The transmission range depends on a few variables such as construction of the walls and ceiling. Based on usual construction the unit is designed to be sufficient for a large single-family home. Interference The modular safety system is not affected by interference proceeding from items such as cordless or mobile telephones. Each alarm detector operates with an unique alarm code, thus preventing false alarms caused by other alarm systems fitted in the vicinity. Non-liability The products are quality products, which operate reliably under normal conditions. Nevertheless manufacturers and dealers must exclude any adhesion or requirements for compensation, which could result from a failure of the system. Technical data Operating voltage range: 230V_ ±10 % Ambient service temperature: 5 C to 55 C Humidity: Rel. humidity < 80 % Acoustic alarm emission level: > 85 db/m Integrated operating indicator: 1 green LED Integrated alarm indicator: 1 red LED Integrated malfunction indicator: 3 yellow LEDs Number of alarm units connected to one system: 20 pcs. Humidity protection: IP20 Weight: 205 g Dimensions: 75 x 128 x 78 mm 21/00 Page: 6 of 7

Acceptance of guarantee We accept the guarantee in accordance with the corresponding legal provisions. Please return the unit postage paid to our central service department giving a brief description of the fault: Gira Giersiepen GmbH & Co. KG Service Center Dahlienstrasse 12 D-42477 Radevormwald The CE sign is a free trade sign addressed exclusively to the authorities and does not include any warranty of any properties. Gira Giersiepen GmbH & Co. KG Postfach 1220 D-42461 Radevormwald Telefon: +49 / 21 95 / 602-0 Telefax: +49 / 21 95 / 602-339 Internet: www.gira.de 21/00 Page: 7 of 7