Remote Alarm Panels Features

Similar documents
EATON DFDAP-M / FDAP-M Remote Alarm Panels

DIESEL Engine Fire Pump Controllers Features

DIESEL Engine Fire Pump Controllers Features

Transfer Switch Features

FDF Foam Pump Controllers Features

DIESEL Engine Fire Pump Controllers Features. FD120 Diesel Engine Controllers

Transfer Switch Features

Fire Pump Controllers Foam (Additive) Controllers

FT60 Reduced Voltage - Autotransformer

LMR Electric Fire Pump Controllers Features

LMR Electric Fire Pump Controllers Features

Model APD. Remote alarm panel for diesel motor driven fire pump. Drawing Submittal Package

FD30 Full Voltage - Across the Line July 2011

Variable Frequency Drive SERIES MP800 VFD

Across-the-Line SERIES MP300 Combined Manual and Automatic

Customer Connection Terminals Connection terminals for external customer connections, are located at the top of the Power I/O board.

Soft Start Series MP700 Solid State, Reduced Voltage

Fire Pump Controllers Medium Voltage Controllers

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

Model VPS Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass

PROJECT: CUSTOMER: ENGINEER: DRAWING CONTENTS: WIRING

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

FTA200-A REMOTE ALARM PANEL

WARNING. Installation Tip: Try out this unit before installing onto a fire door system. Test and learn the release INTRODUCTION

Commercial and Light Industrial Fire Alarm Control Panel

1.1 REFERENCES.1 American National Standards Institute/National Fire Protection Association (ANSI/NFPA).1 ANSI/NFPA 20, Centrifugal Fire Pumps.

FT40 Reduced Voltage - Part Winding. Electrically and Mechanically

FT20 Full Voltage - Limited Service. Electrically and Mechanically

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

Project: Customer: Engineer: Pump Manufacturer: Model GPY + GPU. with Automatic Power Transfer Switch

Specification/ Data Sheet

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

Conventional Releasing Control Panel

CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

Drawing Submittal Package

ACSI Series 1550K-MD and 1550-MD Motor Drive Electric Latch Retraction

AL600ULADA. NAC Power Extender. Installation Guide

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

Model VPS + VPU Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass with Automatic Power Transfer Switch

AUTO RESET ALARM RELEASE BOX MODEL AR-C INSTRUCTION MANUAL

TECHNICAL DATA OBSOLETE

Power Supplies. Overview

Drawing Submittal Package

Fax (724) Main St.; P. O. Box 248 West Middlesex, PA IMPORTANT NOTICE

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

FDJ SERIES Jockey Pump Controllers Features

CONVENTIONAL FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels MEA. Features. Description

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

Technical Data Submittal Document

MANUAL RESET ALARM RELEASE

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs

AL800ULADA. NAC Power Extender. Installation Guide

Installation Guide for models:

AEGIS FEATURES DESCRIPTION. Conventional Fire Alarm-Suppression Control Unit. Effective: March Programmable Relays

Check It Panel. 1 Phase Simplex Demand Dose Operation, Maintenance & Installation Manual. Introduction. Safety Guidelines

INSTRUCTION MANUAL. AlarmGard Chain Operator (Model FCA) AlarmGard Crank Operator (Model FKA)

6 Zone 120/60/1vac 3A 24 VAC class 2 2 x 40 VA 2 x 5 amp fuses 1/6 hp, 120 VAC

MODEL ZA-8N EIGHT ZONE ANNUNCIATOR FOR ALL MONITORING APPLICATIONS OUTSTANDING FEATURES

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

- Four (4) Fused Outputs - Four (4) PTC Outputs. - Eight (8) Fused Outputs - Eight (8) PTC Outputs

MODEL B2 INSTALLATION MANUAL

Series. Access Power Controllers. Installation Guide

MR-2602 Two Zone Fire Alarm Control Panel

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

For a red enclosure add an R suffix to the part # e.g. eflow4na8dr. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

Installation Guide for models:

SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES

DTA. Motor thermistor relay. Benefits. Description

SECTION AUTOMATIC TRANSFER SWITCHES

Leak Detection System Leak Minder Model: LDA-1 Instruction Manual

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section CHLORINE GAS LEAK DETECTOR

MANUAL RESET ALARM RELEASE BOX

INTRODUCTION / TABLE OF CONTENTS

RELEASE DEVICE CONTROLS

AL600ULX Series. Power Supply/Charger. Installation Guide

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

SP40S-D. Kingfisher Company, inc. Features: Description:

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

Control Relay Modules

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

Model A1600 Series Annunciator

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

For a red enclosure add an R suffix to the part # e.g. eflow4na8r. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

FTA550 JOCKEY PUMP CONTROLLERS

INTELLIGENT FIRE ALARM CONTROL PANEL

Installation Manual CFP-105. Fire Alarm Control Panel. Version 1.0

10-175UL INSTALLATION. Power Supply UL. Access Control Power Supply/Charger. Installation and Specifications Manual

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

Oxygen (O2) Single-Point Gas Detection System

Booster Power Supply Manual

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

WFDE Series Waterflow Detector

Transcription:

Features 1-1 DFDAP-M / FDAP-M Remote Product Description Eaton s Remote s are designed to provide audible and visual alarms for Electric and Diesel Fire Pump Controllers. These remote panels are located at a point of constant attendance when the pump room is not constantly supervised. Product Features Microprocessor Control All DFDAP-M and FDAP-M Remote Alarm Panels are microprocessor based. The same microprocessor board is used for both Electric and Diesel units. Power Supply Voltages Both Normal and Supervisory (backup) power supply voltages can be supplied from 110 to 240Vac, 50-60 Hz. Both Normal and Supervisory power is supplied by customer. Normal / Supervisory (backup) Power Source If the Normal power source is not available, the controller will automatically switch to the Supervisory (backup) source. When normal power is restored, the controller will switch back to the normal source. Audible Alarm An audible buzzer will sound when any alarm condition occurs. It will continue to sound until either the Silence Alarm button is pressed, or the alarm condition is satisfied. Lamp Test Button The lamp test button on the membrane will simultaneously test all LED s. Silence Alarm Button The Silence Alarm button on the membrane will silence all active alarms when pressed, but has no effect on the associated alarm LED(s). If another alarm condition occurs after the silence button has been pressed, the alarm buzzer will re-sound until the button is pressed again, or the alarm condition is satisfied. User Selectable Alarm Inputs Each panel accepts up to eight (8) inputs. Each input can be selected as either normally open or normally closed by use of jumpers on the microprocessor board. Normal Power On Indication The Normal Power On LED will turn ON when the normal power is available and will turn OFF when the controller switches to the Supervisory (backup) power source. The alarm buzzer will sound when the normal power is not available and will remain ON until the normal power is restored, or the Silence Alarm button is pressed. Output Relays Output relays are PCB style - rated for 8A/250VAC. NEMA 1 Enclosures All remote alarm panels come standard with NEMA 1 enclosures. Membrane Indication Inputs five (5) and six (6) are directly connected to two LED s on the bottom left on the membrane. A space is provided beside each LED for labeling purposes. Inputs seven (7) and eight (8) are directly connected to two LED s on the bottom right on the membrane. As well as LED indication and labeling area on the membrane, they will each provide an output signal from a corresponding SPDT, 8Amp relay. Electric Normal Power On Supervisory Power On Pump Running Phase Failure Phase Reversal Common Alarm Custom - (2) Custom with SPDT, 8Amp relay Output - (2) Diesel PUMP RUNNING PHASE REVERSAL ENGINE RUNNING LOW FUEL PHASE FAILURE NOT IN AUTO MODE Electric Remote 99-5814-01 Diesel Remote 99-5815-01 Normal Power On Supervisory Power On Engine Running Not In Auto Mode Low Fuel Common Alarm Custom - (2) Custom with SPDT, 8 Amp relay Output - (2) Technical Data and Specifications Line Terminals (Incoming Cables) Recommended Wire Size Stranded # 16 Stranded # 14 Stranded # 12 Distance Number of feet (meters) from the controller to the remote alarm panel. 3000 (914.4) 4500 (1371.6) 7000 (2133.6) Standards & Certification The DFDAP-M / FDAP-M Remote s meet or exceed the requirements of Underwriters Laboratories, Underwriters Laboratories Canada, the Canadian Standards Association, the New York City building code, and are built to NFPA 20 standards. BR05805024K/G

Main Display Main Display - DFDAP-M Diesel Engine Remote Main Display Diesel Remote ENGINE RUNNING LOW FUEL NOT IN AUTO MODE MD05805158K/B

Dimensions DFDAP-M Diesel Remote Dimensions Standard Enclosure - Type NEMA 1 - Diesel Remote 15.49 [393] 11.56 [294] 9.75 [248] 9.55 [243] 8.00 [203] 0.27 [ 7]x4 WALL MTG. HOLES 4.74 [120] Approx. Weight Lbs. (Kg) 10 (4.5) NOTES: 1. All enclosures finished in FirePump red. 2. Cable Entrance either top or bottom. 3. Standard Enclosure type NEMA 1. MD05805055K/C

Electrical Wiring Schematic DFDAP-M Diesel Remote Electrical Wiring Schematic : ES05805133K/E

Features DFDAP-M / FDAP-M Remote s Typical Specifications 1. Approvals A. The Remote shall meet the requirements of the latest edition of NFPA 20 and shall be listed by [Underwriters Laboratories (UL)] [Underwriters Laboratories of Canada (ULC)] approved by [Canadian Standards Association (CSA)] and have MEA approval for New York City. 2. Construction A. The remote alarm panel shall be equipped with a Lamp Test button which, when operated, fully tests all LED s. The Lamp Test Button shall not change the state of internal relays. B. The panel shall automatically detect input voltages between 120Vac and 240Vac 50/60Hz on either of the primary and backup source inputs. The panel shall operate such that if the primary source of supply is lost, the panel will automatically switch to the backup source. Both the primary and backup sources shall be independent of each other. C. An audible buzzer shall sound when any alarm conditions are present. It shall continue to sound until either the silence button is pressed, or the alarm condition is satisfied. D. A silence alarm button shall be provided to silence all active alarms when pressed. It shall have no effect on the associated alarm LED s. Should a second alarm condition occur after the silence button has been pressed, the audible alarm shall re-sound until the silence button is pressed again, or the alarm condition has been satisfied. E. A Normal Power On LED shall indicate when normal power is available and shall turn off when the controller switches to the Supervisory (backup) power source. An audible alarm shall sound when normal power is not available and shall remain ON until normal power is restored, or the silence button is pressed. 3. Enclosure A. The panel shall be housed in a NEMA Type-1 enclosure provided with means for wall mounting. 4. Input Contacts A. Contact inputs shall be dry contact (non powered). Each input shall be capable of being selected as either normally open (N.O.) or normally closed (N.C.). 5. LED Visual Indication A. Electric alarm panels shall be provided with six (6) LED visual indicators to indicate Normal Power ON, Supervisory Power ON, Pump Running, Phase Reversal, Phase Failure and Common Alarm. Diesel alarm panels shall be provided with six (6) LED visual indicators to indicate Normal Power ON, Supervisory Power ON, Engine Running, Not in Auto Mode, Low Fuel, and Common Alarm. 6. Output Contacts Electric and Diesel alarm panels shall provide two (2) programmable alarm outputs that correspond to user programmed inputs. B. All outputs shall be printed circuit board relay style rated for 8amps / 250VAC. The relays shall be de-energized under normal conditions regardless of input status selected. 7. Manufacturer A. The panel manufacturer shall manufacture the enclosure and provide completely assembled units. B. The remote alarm panel shall be manufactured by Eaton Corporation. PS05805007K/D