EMEX 110 and EMEL. EMEX 110 and EMEL. 110, 50 and 24 volt AC/DC Central Battery Systems. EMEX 110 and EMEL

Similar documents
Loadstar AC/DC Systems

Since 1998, the Emergi-Lite brand has been included in the product portfolio of the Thomas & Betts Corporation.

» EN50171» Lighting» Reliable

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

Spectron LSN (Life Safety Network) Suggested Specifications

Power Supply / Battery Charger Units, incorporating load switching relays for Smoke Dispersal, Bell Booster or other uses

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

1 INCA INCA MODEL FPC FIRE PUMP CONTROL PANEL. (Star Delta/D.O.L) USER MANUAL Inca Reference FPC Revision 1.0

Fire and Smoke Control Systems

Dale Power Solutions Ltd

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts

ILLUMINATOR E & IE CENTRAL INVERTER FOR EMERGENCY LIGHTING

ILLUMINATOR E & IE CENTRAL INVERTER FOR EMERGENCY LIGHTING

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

La Marche Manufacturing Company Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual

An introduction to... Sigma

Item/clause/Page no. Description as per tender. To be read as

PowerWizard Range. Digital Control Systems & Remote Communication Options. PowerWizard Providing Safe Control of Your.

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. HZM-Series-Class I, Div 2 Battery Unit. Instalation instructions

Features. Omni2 Door Warning Sign Alarm Annunciator DATASHEET. Model C1190B Door Warning Sign

ELECTRIC FIRE PUMP CONTROLLER

Advanced Air. Hard Wired Damper Control Panels. Systems 10, 11, & 12. Hard-Wired Systems. Bespoke Systems Available. Value Engineered Solutions

Installation, Operating and Maintenance Manual

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

Digital Control Systems & Remote Communications Options

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 3LERHZ Series Class I, Div 2 Combo Unit. Installation instructions

SCR/SCRF SERIES. Industry s First Choice for Time-Tested Proven Reliability FLOAT BATTERY CHARGERS. Single-Phase Input

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

Excel-EN Conventional Fire Control Panel

RE-PR3-E-27 3-Phase Panel Mount 27kW

Gas ventilation monitoring and control system

New Silent Alert Fire Safe System

Installation and user manual for the BiWire / Conventional Repeater Panel

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

APC BC300 Series 40kW 208/450/480V User Guide

Vocia VACIE. Reference Guide

R E C T I F I E R I N V E R T E R C O N V E R T E R SB7

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

MODEL KP-200 VANDAL RESISTANT & WEATHERPROOF FLUSH MOUNT DIGITAL KEYPAD DESIGNED FOR ACCESS CONTROL APPLICATIONS

La Marche Manufacturing Company Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual

SECTION POWER SUPPLIES AND DISTRIBUTION

VACIE REFERENCE GUIDE REVISION 1.2.6

ILLUMINATOR EM. CENTRAL LIGHTING INVERTER 1000 VA/W through 2800 VA/W 98% Efficiency!

Catalogue. ActionpacEMSStandard. Electro Mechanical Control & Monitoring System.

Ozone Generator and Ozone PCB Tests and Fault Troubleshooting

NERC PRC Compliance Guide

CPA6. Installation & User Guide. Intelligent Security & Fire Ltd. Compatible Equipment

FLOAT BATTERY CHARGERS

LiteMinder. LM Series Inverter Pure Sine Wave Modular Inverter Technology. Fast Transfer System 1.0 to 18.75KVA LED Compatible

Guide Specification Model CTG Automatic Transfer Switch

Dublin airport - Dublin, Ireland

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs

Central Emergency Lighting Inverter Systems

SMARTELEC 2 ENERGY SAVING CONTROL INSTALLATION AND OPERATING MANUAL

SCR/SCRF SERIES. Industry s First Choice for Time-Tested Proven Reliability FLOAT BATTERY CHARGERS. Single-Phase Input

21-light Remote Annunciator. Owner s Manual

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

Float Battery Chargers Unfiltered SCR and Filtered SCRF Series Single Phase Input / Three Phase Input

1.1 RELATED DOCUMENTS: 1.2 DESCRIPTION OF WORK: 1.3 QUALITY ASSURANCE: 1.4 Warranty SECTION BATTERY EMERGENCY POWER SUPPLY PART 1 - GENERAL

Networked Access Control Panel. Installation Guide

Constant voltage charger. Type UP 610. »We store the world's energy« Network

Eagle Eye Battery Monitoring Solutions BMS-Series

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

July 14, 1999 DF C-100.

0$; Installation Instructions. Computerized Control Panel '(6&5,37,21 63(&,),&$7,216 DE5011 1

Item Number Description Price. Accessories " Diesel/Water/Waste tank sender $ Battery temperature sensor $2.22

The CAB & DAB Air Curtains

THERMODYNAMICS STEAM P7690 AND STEAM BENCHES CUSSONS TECHNOLOGY LABORATORY RECOMMENDATION

highline SVCS-1 INSTALLATION & USER MANUAL SMOKE VENT CONTROL SYSTEM * enclosure design may vary software version: SVCS1r6 SVCS1r7 SVCS1r10

PowerWizard. Level 1.0 & Level 2.0 Control Systems Training

PAT E N T System 88. COMPLIES WITH Singapore Standard : SS CP10 : 2005 British Standard : BS EN54-2 : 1998 BS EN54-4 : 1998 REV.00

PowerWizard Range. Digital Control Systems & Remote Communication Options.

FDF Foam Pump Controllers Features

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel


Application, Installation, Operation & Maintenance Manual

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

NXM2G Installation and Operating Manual

MINERVA MX. 800 Series Ancillary Equipment

SBS-H2. Hydrogen Gas Detector Kit. For battery charging rooms and other areas where hydrogen gas may be present

VoCALL - CFVCC5. Compact 5 Line Exchange Unit. Installation & Commissioning Manual

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. NXM Series - Survive-All. Emergency Light Unit

Silent Alert Fire Safe System

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

MANUAL. OEM (Unit) OZONE GENERATOR (100VA, 200VA and 300VA) INDEX

Prem1er EVACS16. Installation Manual VOICE ALARM CONTROL PANEL 4 16 ZONES

ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual

Multiple Battery Cabinets Dual-Lite TRN. External Maintenance Switch Configuration Options. External Maintenance Switch Options

AS950 REFRIGERATED SAMPLERS

NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL

FEC400 Series. Installation Manual

BX444-Mc Gas Detector

Access Control (card access)

SETION EMERGENCY LIGHTING NATIONAL FIRE PROTECTION ASSOCIATION (NEPA) (2006) Life Safety Code, 2006 Edition

Constant voltage 3-phase rectifier.

AS950 PORTABLE SAMPLERS

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

Transcription:

and EMEL and EMEL 110, 50 and 24 volt AC/DC Central Battery Systems and EMEL

System design units provide 110V AC/DC to provide power to 110V slave fittings or converted mains luminaires. Systems provide 110V AC continuously under mains healthy conditions, and battery back-up at 110V DC upon mains failure. units benefit from the same modular construction as the EMEX Power static inverter range. Charger modules utilise solid state electronics of the highest reliability. Units feature BS 5424 contactors and MCB protection throughtout, to provide a rugged easy to maintain system with exceptional performance for emergency lighting use. Each charger has input and output protection, and measures and limits its own current, making it a self-contained unit. Alarms and status indicators are provided on the front panel display, which provides clear and concise information, rather than a long list of parameters, which may be confusing. EMEX Power is designed and manufactured in the UK. 1

Standard features: system overview EMEX Power offers a host standard features & benefits, as listed below. Note that some items will be optional, extra cost items on other systems, or may not be available at all if the system is not designed specifically and solely for emergency lighting use. Performance 110V AC/DC output Excellent recharge capability 80% after 12 14 hours following rated discharge MCB protection throughout; no fuses EMEX Power true modular construction with common spares (charger, control PCB, and system interface common across the full system range) Individual MCB protection for each module - AC and DC circuits Individual cooling fans for each charger with on-demand operation (not continuously running) Split parallel charger above 10 amps enhanced integrity with the ability to operate with one or more charger modules isolated (subject to increased recharge time) Integral maintenance bypass facility (ability to support output load in bypass mode whilst maintenance is performed) Temperature compensated charger Alarms and instrumentation Comprehensive display Charger alarm pack Momentary push to test button Fire alarm interface Final exit interlock Internal and external MCB monitoring Local/remote maintained circuit control Sub-circuit monitor connection Two sets of volt free alarm relay contacts System-inhibit engineers switch Remote Alarm Unit option Mechanical IP21 rated cabinet as standard Easy front panel access Inter-cabinet trunking for battery cables Fork-lift plinth Lifting eyes for crane lift as standard Installation pack with all tools required Detailed instruction manual Batteries Standard systems are supplied with Valve Regulated Lead Acid (VRLA) batteries, also known as 'Sealed Lead Acid'. These batteries are sealed for their design life of 10 years. Lead Acid Plante and Nickel Cadmium batteries are available upon request, however, these batteries require a much larger physical area, and emit potentially explosive gasses, meaning the battery room must be adequately ventilated. These reasons, along with the additional capital cost, generally outweigh the additional life obtained, as demonstrated below. Battery Initial cost Design life Maintenance VRLA YY Ni-CAD YYYYY Planté YYYY 2

Order codes 1 hour 110V AC/DC systems Rating KVA Watts Cabinet Part No. 2.0 1,900 S ELD9100.120 3.0 2,700 L ELD9100.121 4.0 4,000 L ELD9100.122 5.5 5,500 L ELD9100.123 Other system sizes and ratings are available please contact us if your requirements are not shown here. 3 hour 110V AC/DC systems Rating KVA Watts Cabinet Part No. 2.0 1,000 S ELD9100.130 2.0 1,600 S ELD9100.131 2.0 2,000 L ELD9100.132 3.0 2,700 L ELD9100.133 4.0 3,600 L ELD9100.134 5.5 4,860 S + L ELD9100.135 5.5 5,400 S + L ELD9100.136 Remote alarm British Standard BS 5266 Part 8 (BS EN 50172) section 7.2.2 requires that a visual daily check of the central battery alarms is made. It is also a requirement that the CBS should be located in a secure area, which is typically a locked switch room in the basement. We offer an optional Remote Alarm Unit (RAU), which will enable the user to perform the required daily check without the need to physically access the equipment. Remote Alarm Unit RAU/240 ELD0075.003 Remote alarm unit providing both audible and visual fault indication with mute facility. The RAU requires a local 240VAC supply and should be linked to the static inverter unit by a two core cable. Cabinet sizes Cabinets are available in two standard sizes small (denoted below by S) and large (denoted below by L). Small is 400mm wide, large is 750mm wide. Both cabinet sizes are the same height (1,800mm) and depth (650mm). Overall depth of 725mm is required to allow a ventilation gap of 75mm (rubber back-stop provided ensures this distance is maintained). Cabinets may be mounted side-by-side since no side ventilation is required. 3

EMEL EMEL mid-range 110V, 50V and 24V AC/DC central battery systems in 1, 2 or 3 hour durations Compatible with a range of AC/DC slave luminaires, converted mains fittings Suitable for small and medium sized installations, EMEL Light Duty provides an effective solution where self-contained fittings may not be appropriate, eg where ongoing maintenance may be disruptive Ideal for refurbishment of an existing installation, and is suitable for local authority specification work EMEL Economy systems are supplied with 5 year design life valve regulated lead acid batteries. They include a mains on indicator and charge fail alarm as standard. EMEL 24V AC/DC Economy EMEL Standard systems are supplied with 10 year design life valve regulated lead acid batteries and include mains on indicator and charge fail alarm, together with a moving coil ammeter and voltmeter as standard. EMEL 24V AC/DC Standard 100W to 700W 400W to 800W Option list (EMEL Standard only) Remote Alarm Unit (/RAU) Phase Failure Relay (/PFR) Fire Alarm Relay (/FAR) Sub-Circuit Control Relay(s) (/SCR) Maintained Control Relay (/MCR) Digital Ammeter/Voltmeter (/DM) Time Switch (/TS) High/Low Volts Monitor (/HL) Earth Fault Monitor (/EFA) Common Alarm Relay (/CAR) EMEL 50V AC/DC Standard 200W to 2,000W EMEL 110V AC/DC Standard 600W to 3,500W For larger 110V systems, please refer to our range 4 EMEL