Tech Tips (December 2016) Product Information

Similar documents
Tech Tips (April 2016) Product Information

Tech Tips. Chart MVE CryoSystem 6000 Full Auto. Serving Customers around the World. (March 2016) Product Information

MVE Chart Tech Tips PRODUCT INFORMATION MVE205AF GB

MVE Chart October 2014 Tech Tips

MVE TS Controller (Touch Screen)

MVE Chart Tech Tips PRODUCT INFORMATION. MVE CryoSystem Series

MVE HEco 800 Series Freezers

Thermo Scientific Cryopreservation Storage Equipment

MVE Variō Series with MVE Variō Pro Controller

Remote Alarm Monitoring Alarm monitoring includes Global Remote Alarm Relay. Capabilities independent port can be used

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

LIBERO PDF Logger for Cryogenic Container Monitoring

The Kryos LN2 Liquid Level Control & Cryogenic Temperature Control

Multi Boiler Guide. Kit #

CommStat 4. Controller for Redundant Telecom HVAC Systems PRODUCT DATA SHEET. Features and Benefits

UHV Flow Cryostats. Ultra High Vacuum Flow cry stats CRYO INDUSTRIES

NEW Cold Storage Offers that deliver the right cold storage solutions at the right time. That s smart

CommStat 4 Controller

INSTALLATION MANUAL. Need Help? This manual covers the following models: T915. Power Type. Thermostat Applications Guide. Page.

Chart Cryogenic Freezers. with MVE TEC3000 Controllers Operating and Maintenance Manual

CONVENTION 192 PATIENTS 384 PATIENTS BREAKTHROUGH CONCEPT

INSTALLATION MANUAL. This manual covers TopTech models: TT-N-851. Need Help? Power Type. Thermostat Applications Guide. Page.

York 25-Ton VAV Rooftop Unit

B-40/B-41 Modulating Temperature Controller

EFT-3002 PORTABLE EMBRYO FREEZER INSTRUCTION MANUAL MANUFACTURED BY. BELTRON Instruments

SC-9 Controller INSTALLATION AND OPERATING INSTRUCTIONS. SC-9 Applications CONTENTS

MVE CRYOGENIC FREEZER with MVE TEC 3000 TECHNICAL MANUAL

SpaceWise Rack Our SpaceWise Rack creates more room so you can cook multiple dishes at once.

Chart MVE TS Controller (Touch Screen) TECHNICAL MANUAL

Rev This manual covers the following models: T771. Mounting and Battery Installation

FOR MORE INFORMATION AND PRODUCTS, VISIT: USER MANUAL TO REMAIN IN VEHICLE

QD-ENG-68 Controller for Thermoelectric Thermal Management

MVE TEC 3000 TECHNICAL FREEZER MANUAL

ISO-9001:2008 FURNACES CATALOG. Phone: Fax: Web:

200i/KN2, KN4 Firmware Revision Sheet

DCIF Training Guide Variable Temperature Bruker B400 and B401 (last update )

quick start guide RFG237AA RFG238AA

INSTRUCTION MANUAL FOR Freeze Dry Systems PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

Owner s Manual. Part Number 33CSCPACHP-01

INSTALLATION MANUAL. * If using remote sensors the thermostat must be hardwired. Need Help?

Type M505CE Liquid Nitrogen Level Control System Installation and operating Instructions. Revision Status

Fits-More Capacity. Extra-large microwave provides 1.6 Cu. Ft. of cooking space and will hold almost any dish even a 13" x 9" baking dish.

Thermo Scientific Cryopreservation Equipment

Featuring Bake & Brown Convection Product Dimensions. Bake & Microwave Option

INSTALLATION MANUAL. Need Help? This manual covers the following models: T755. Power Type. Thermostat Applications Guide. Page.

CryoPod Carrier. Quick Start Guide. English Quick Start Guide, 2 Français Guide de démarrage rapide, 8 Deutsch Schnellstartanleitung, 14

Installation and Operation Manual

INSTALLATION MANUAL. Need Help? This manual covers TopTech models: TT-N-721 and T721. Power Type. Thermostat Applications Guide.

Undercounter Refrigerator Operation Manual i.series and Horizon Series

Model Universal Oil Primary Control

TWLC - Tempered Water Logic Controller. The Intelligent Control

Vacuum Insulated Pipe

SOP SF SOP for LN2 Freezers

Autofire Express Ramp/Hold Controller Instruction Guide

TR/TS40, TR/TS16, TR/TS60 Thermostat

i.c³ User Guide For Helmer i.series Ultra-Low Freezers A/A

TrilliumSeries Condenser 1 TRILLIUMSERIES CONDENSER 10 ECOFLEX CONTROLS 11 SELECTION AND PAYBACK ANALYSIS SOFTWARE 3 BENEFITS 8 MODES OF OPERATION

INSTALLATION MANUAL. Need Help? This manual covers the following models: T725. Power Type. Thermostat Applications Guide. Page.

VT8300 Series Installation Guide 24 Vac Low Voltage

REVCO MECHANICAL CRYOGENIC FREEZER

PRODUCT BULLETIN. Rev. A Monitoring Station offering PN Rev. B as a direct replacement. OVERVIEW / DESCRIPTION

PR-L2466W- PA. Operating Instructions. High Performance Refrigerator PR-L2466W-PA

Power Locking Installation Manual

T6865 Series Large LCD Digital Thermostat 24 VAC 2-pipe fan coil control

INSTALLATION INSTRUCTIONS

Impact of Manual Defrost vs. Auto Defrost Freezers on Sample Temperature

SC-3 Controller INSTALLATION AND OPERATING INSTRUCTIONS FOR GAS-FIRED, OIL FIRED AND DUAL FUEL HOT WATER HEATING PLANTS. SC-3 Applications CONTENTS

918TS Manual 1/26/09-1 -

Thermo Scientific Cryopreservation Equipment

VT8000 Series Replacement Procedure to Replace VT8000 Series Room Controller and Pair with ZigBee Pro Sensors

Liquid Nitrogen Storage Solution

ONX908MTW-0/24V MULTI STAGE THERMOSTAT

INSTALLATION MANUAL. This manual covers TopTech models: TT-S-755H. Need Help? Thermostat Applications Guide. Power Type. Table of Contents.

INSTALLATION, OPERATION & QUICK START GUIDE

High-Efficiency Front-Load Washer

The Vitro-i. Radiant / Convector Combination Heater. Instructions for Operation and Installation

Dryer Troubleshooting Guide

AVANT DGi. Thermal Electric Radiator. Operating and Installation Instructions. (Read these instructions carefully and retain for future reference)

Featuring Bake & Brown Convection Product Dimensions. Bake & Microwave Option

SAS6000UTK-7-WIFI OPERATING INSTRUCTION

WeatherLink for Alarm Output Addendum

Over-the-Range Microwave professional series

Quick-Start Guide Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input Models and

Dryer Controller M720

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

endless advances for your customers WATER HEATING SOLUTIONS FOR BUILDERS

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS...

Chemistry diaphragm pumps

Spa Touch Control Panel with BP2100, BP6013 spa controllers. (Spa Owner s Manual insert)


T-32-TS Touchscreen Thermostat. Installation Manual

Fits-More Capacity. Extra-large microwave provides 1.6 Cu. Ft. of cooking space and will hold almost any dish even a 13" x 9" baking dish.

Bio System Installation

7400 Series. CRYO Plus Liquid Nitrogen Storage System

Spa Touch Control Panel with 2000, 2100 controllers. (Spa Owner s Manual insert)

HEAT HEAT HEAT COOL COOL

Vacuum Pumping process for Large Camera Dewars supplied by PixelVision of Oregon

Igloo. Ultra low temperature freezers -45 o C & -86 o C Upright & Chest 370 to 830 liter

TEC2620 Series Non-Programmable Fan Coil Network Thermostat Controller and Remote I/O Relay Packs

HP50HA ABG Heat Pump

Transcription:

Tech Tips (December 2016) Product Information Variō Pro Controller Firmware Update Chart MVE has released a new firmware version for the Variō Pro controller. Version 0.23 will now replace 0.20 as the current release firmware. In order to upgrade to version 0.23 firmware, it is required to have a laptop, a TEC COM kit (PN 13376947), and the associated Firmware Installer program. Please contact the Technical Service department if you have any questions. The new features include: One-Cool-All-Cool functionality for simultaneous and sequential cooling; based on One- Fill-All-Fill Required setup screens (OCAC mode in Com1 Type, OCAC menu, OCAC ID, OCAC units and simultaneous/sequential selection) All Chart MVE Full Auto Freezers As part of Chart s continuous improvements we have transitioned to a more robust 2.0A power supply as of July 1, 2016. The new part number is PN 20965617. The previous power supply (PN 11795030) was rated at 1.2A. To help maintain our traditional backward compatibilities, the new power supply can be used on the TEC2000 s, TEC3000 s, and Variō Pros. Its dimensions/appearance will be exactly the same as the previous power supply. The new power supply will be a direct replacement and will not require any adaptors. All upgrade kits/service parts will transition to the new power supply.

Stainless Steel Basket Pictured left is previous power supply (PN 11795030). Pictured right is new power supply (PN 20965617). Chart MVE offers a basket assembly that is used in conjunction with the SS transfer Dewars. The basket is not designed for long term storage inside the Dewars, but rather for shrink fitting or the cryo-treating of metal parts. MVE CryoCube PN 11066283 The new MVE CryoCube is a secure cryogenic shipping option for your biological samples. The CryoCube incorporates creative engineering and simplistic design to allow shipping in any orientation without sacrificing temperature or hold time. Improved welded construction

provides the CryoCube with consistent, high quality design with every unit. The CryoCube allows for savings on dry ice, packaging, shipping cost, and disposal.

Helpful Hints/FAQ s Function Testing the Hot Gas Bypass System 1. Press the Fill Start button to initiate a fill cycle. The gas bypass valve should open, and nitrogen vapor should exit the exhaust muffler. 2. After the plumbing is cooled to the preset temperature (default is -70 C), the bypass valve should close, and the freezer should begin filling. 3. If liquid nitrogen begins to exit the muffler before the freezer begins filling, the Hot Gas Bypass Setpoint should be increased. The factory default value is -70 C. Increase the temperature setting in 10 C increments (-60 C, then -50 C, etc) until desired operation is achieved. 4. If the filling process begins before the plumbing is sufficiently cool, the Hot Gas Bypass Setpoint should be decreased. The factory default value is -70 C. Decrease the temperature setting in 10 C increments (-80 C, then -90 C, etc) until desired operation is achieved. 5. In applications where the piping is very long and/or uninsulated, a Hot Gas Bypass Alarm may occur. In this case, increase the Bypass Time Delay in 5 minute increments until the freezer is able to complete the bypass cycle without initiating an alarm. The factory setting for the Hot Gas Bypass Alarm Time Delay is 5 minutes.

CryoShipper, CT-50, and CT-250 Fuzzy Cork Q: What is the difference between the fuzzy cork/cover assemblies compared to a standard cork/cover? A: The fuzzy cork assembly used with the Cryoshipper, CT- 50, and CT-250 vapor-shippers incorporates a polyester fleece-like material that is adhered to the cork. The fleece material is an extremely durable fabric that attempts to resist moisture, dries quickly, and will also help to prevent cork particles from falling down into the storage chamber. CT-250 Fuzzy Cork/Cover - 21003472 CT-50 Fuzzy Cork/Cover - 21007703 CT-250 Fuzzy Cork/Cover CryoShipper Cork/Cover PN 20552547 (standard) CryoShipper Fuzzy Cork/Cover PN 20553315 Cabinet Series Freezer Key Replacement Q: I have lost the key to unlock our cabinet style freezer. How can I obtain a replacement key? A: A replacement key may be ordered by contacting our customer service department and referencing part number 11929675 along with the specific key code for your freezer. The key code is located on the freezer shell. To access the key code, simply remove the back panel and the key code will be displayed on the vent chamber (shown below in red):

Accessories MVE Series Optional Vapor Platforms Chart offers optional vapor platforms for the MVE Open-Top Series. When ordering, please keep in mind that vapor platforms occupy approximately 4 to 5 inches of the freezer's usable space, which may affect the necessary rack size. Freezer Model Vapor Platform PN MVE 205 10544837 MVE 510 10544853 MVE 616 and MVE 616 Cabinet 11509726 MVE 1426 and MVE 1416 Cabinet 10544888 MVE 1839 10544909 *Note: Utilizing the optional vapor platform with open top freezers will increase nitrogen consumption. Temperature Reduction Hanging Sleeves for the MVE Series Chart has designed temperature reduction sleeves to provide a lower temperature difference when storing in vapor. Chart manufactures these sleeves specific to Chart MVE series freezers only. The estimated temperature reduction is approximately 10ºC (18ºF) for the MVE 200, MVE 500, and the MVE 600 Series. The estimated temperature reduction is approximately 20ºC

(36ºF) for the MVE 1400 and MVE 1800 Series. Please note, the use of these sleeves will lead to a higher use of LN2. Part numbers are listed below for the specific MVE Series: Freezer Model Hanging Sleeve PN MVE 205 11900477 MVE 510 11905227 MVE 616 and MVE 616 Cabinet 11937317 MVE 1426 and MVE 1416 Cabinet 11934044 MVE 1839 11941105