User Manual R1.0 CO2Meter, Inc. Personal CO2 Monitor SAN-10

Similar documents
Pocket CO2 Monitor & Data Logger SAN-0001

CO2 & Oxygen Monitor Operating Instructions Model: RAD

User's Guide. CO 2 Monitor. Model CO200

IMR IX176 Portable Gas Detector User Manual

Model R9400. Instruction Manual. CO Meter with Temperature. wwwreedinstruments. com

E1000 Portable gas detector

MicroTool. Not just a simple Measuring Instrument A complete Tool to support your daily activities FLUE GAS ANALYSERS

IMR EX610. Portable Gas Detector. Operation Manual

Oxygen Monitor Operating Manual

USER GUIDE. Formaldehyde (HCHO or CH 2 0) and Total Volatile Organic Compounds (TVOC) Tester. Model VFM200

For the Safety of Your

CO2 Monitor Operating Instructions

Macurco Single-Gas XL Series Monitor, CM-1XL Carbon Monoxide (CO), HS-1XL Hydrogen Sulfide (H2S) User Instructions

Portable type of Carbon Dioxide Detector Model: GT220

Falcon-II Next Generation, Air Quality Monitor CO2 & Temperature

Remote Storage Safety 3 Alarm Installation Guide

KANE-ALERT-CO 2 Monitor with Temperature

! WARNING! User Manual LogiCO2 -Scout. Important Safety Information! CO2 Concentration Levels (%) and Effects ENGLISH

USER MANUAL Digital CO Monitor Model CO30

ALTAIR 5X Multigas Detector Product Specification

Carbon Monoxide Meter Model CO15. User Manual. Additional User Manual Translations available at

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

MiniCO, MiniH 2 S, MiniOX, MiniOX Remote, MiniCl 2. , and MiniClO 2. Responder Detectors Instruction Manual "! WARNING

VALTRONICS IAQ Monitor

Safe Operation Manual. Honeywell IQ Force Gas Detector

MicroRay IR-100 NEW. Inspection MicroRay IR-100

Single Gas Monitor 777

Indoor/Outdoor Temperature Alert

MODEL: SP12C7. (Portable 4 gas detector) Operating Manual

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012

Indoor Air Quality Meter Rev. 2.x Meters. The Value Leader TM

Model VFM200. User Manual. Formaldehyde (HCHO or CH 2 0) and Total Volatile Organic Compounds (TVOC) Tester

Monitores Personales. Personal Monitor

Carbon Monoxide Transmitter

EST User Manual. (Please read this manual carefully before using)

ALTAIR 5X Multigas Detector

EL-USB-2-LCD+ High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD

Introduction. OM-THA2


ENMET Corporation. PO Box 979 Ann Arbor, MI RECON. Manual. Manual Part Number MCN-410, 12/03/08

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

esense CO2 Transmitter and Alarm

IT S WHAT S INSIDE THAT

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

Operate the Mutli-Gas Monitor PID

MODEL: SP12C7. (Portable 4 gas detector) Operating Manual

USER MANUAL MINITRACER PORTABLE SNIFFER

BST-MG08/09 Multi-gas Detecting Alarm. Manual Instruction

Hygrometer / Air Quality Meter

O3TH. Ozone Detector c/w Indicator for Temperature/Humidity. Automatikprodukter. Features. Technical Data. Description. Ordering Codes. Dec.

Using the QRAE Plus personal multigas monitor

RAE Systems Systems. User Presentation. October Protection Through Detection

Analog Room Pressure Monitor RPC Series

THA2 TEMPERATURE/ HUMIDITY/ DEWPOINT ALARM WITH LOGGING CAPABILITY. 99 Washington Street Melrose, MA Phone Toll Free

User's Guide. Pinless Moisture Meter. Model MO257

BST-MG07 Multi-gas Detecting Alarm Manual Instruction

Pinless Moisture/Humidity Meter with Memory + IR Thermometer

Dual Laser InfraRed (IR) Thermometer

Model:AS8900 MULTI-GAS MONITOR O 2 %VOL H 2S PPM LEL%VOL CO PPM. Version number:as

EasyLog Data Logger Series

CO2 RESPONDER Portable Carbon Dioxide Detector QUICK REFERENCE GUIDE

MultiRAE Lite. Wireless Portable Multi-Gas Monitor

MULTI-GAS MONITOR. Eastern Energy Co., Ltd. 40/4 Vitoondumri Rd., Banbueng Banbueng, Chonburi, Thailand

UniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser

actoolsupply.com User Guide Extech RD300 Air Conditioning AC Refrigerant Leak Detector Refrigerant Leakage Detector Model RD300 actoolsupply.

GasAlertMicroClip X3 Specifications

Aspida. User Manual. Commercial in Confidence

testo 316-EX gas leak detector Instruction manual

IPhone: 219/

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

II 2 G. SENSIT HXG-2d. Ex ib IIB T3 IP20. Suitable for combustible gases such as Methane, Butane, Propane and Natural Gas MADE IN USA

aspida User Manual T: +44 (0) F: +44 (0) W: E:

aura-t TP536/GBR ventilation systems

HOBO U14 Data Logger User Manual

Model C-380. Instruction Manual. Refrigerant Leak Detector. reedinstruments

CO2 Monitoring Frequently Asked Questions for the

Pinless Moisture/Humidity Meter with Memory + IR Thermometer

LD-5000 REFRIGERANT LEAK DETECTOR

1.1 Definitions of alert icons. For your safety

Dual Laser InfraRed (IR) Thermometer

Multifunction IAQ Monitor

Event Monitoring Device (EMD)

ALTAIR 5X Multigas Detector

TM-802 Formaldehyde Meter User s Manual

Operations Manual GMA 313 CO 2. Gas Monitor for one detection point

EVac II Programmable Digital Vacuum Gauge

NH 3 RESPONDER Portable Ammonia Leak Detector QUICK REFERENCE GUIDE

multi-gas detector Go the distance, and save Wear yellow. Work safe.

RECON/4a Portable Multi-Gas Detector Operation and Maintenance Manual

User's Guide. Pinless Moisture/Humidity Meter with Memory + IR Thermometer. Model MO295

Using the MiniRAE 2000 & ppbrae PID

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

The product can be worked together with our wireless controller to control a ventilator, air cleaning device, or

OPERATING MANUAL TORREY PINES SCIENTIFIC, INC. DIGITAL HPLC COLUMN HEATER MODEL CO20 DOCUMENT NUMBER CO20-00

Carbon Monoxide (CO) Gas Detector March 15 GCO 300

TDU Series LCD Thermostat For EFCB and EVCB Controllers. Models. Features. Functions. Onboard Sensors. Model # Temp RH CO2 Color.

Using the GammaRAE II Responder Personal Radiation Detector and Dosimeter in One. Firmware Version 3.00 D August 2006

NATURAL GAS DETECTOR. Confined Space Monitor. Leak Investigation. Line Purge Testing. Bar Hole Sampling

Micro III (Models G203, G203S, and G213) Operation Manual

Transcription:

User Manual R1.0 CO2Meter, Inc. Personal CO2 Monitor SAN-10 Last Revised October 24, 2018 Copyright 2018 CO2Meter Inc., all rights reserved.

Contents INTRODUCTION... 3 FEATURES... 3 MONITOR... 3 LCD DISPLAY... 4 OPERATION...4 MENU/CONFIGURATION... 5 Calibration...6 Alarm Threshold... 6 MAN DOWN FEATURE... 7 MAINTENANCE... 7 SPECIFICATIONS... 8 TROUBLESHOOTING... 9 WARRANTY... 9 CONTACT US... 9 2

INTRODUCTION Congratulations on your purchase of this CO2Meter SAN-10 Personal CO2 Monitor. CO2Meter SAN-10 is a smart carbon dioxide (CO2) monitor using NDIR technology to provide long term stability. The SAN-10 Personal Safety CO2 Monitor is designed for employees who work in enclosed areas where carbon dioxide buildup may cause personal harm. It is designed to alert people in the area with excessive carbon dioxide gas. SAN-10 is shipped fully tested and calibrated and, with proper use, will provide years of reliable service. FEATURES Audible, visual strobe and vibrating alarms Large LCD display Man down alarm leveraging accelerometer technology Rugged design with protective rubber enclosure Heavy duty metal clip Front facing sensor unit Rechargeable Li-ion Battery 4.2v, 1500mAh 18+ hours per charge Black Micro USB cable and Wall USB charger Dual calibration methods: Ambient Air (300-600ppm) and Nitrogen (0-200ppm) Automatic atmospheric pressure compensation for CO2 concentrations No over-exposure or negative memory effects IP54 housing Stable NDIR sensor for CO2 detection MONITOR 1. Visual alarm/strobe 2. Front facing sensor 3. Charging indicator 4. LCD display 5. Power button 6. Temperature unit button 7. USB charging inlet (bottom side) 8. Heavy duty metal clip 9. Factory reset button 3

LCD DISPLAY 1. Low alarm indicator 2. High alarm indicator 3. Battery indicator 4. CO2 concentration 5. CO2 concentration units (ppm or % when >9,999 ppm) 6. Calibration icon 7. Man down alarm 8. Air Temperature 9. Temperature unit (Fahrenheit or centigrade degrees) 10. % Relative Humidity OPERATION Note: LCD backlight will turn off automatically after 5 seconds of inactivity. When LCD backlight is off, press either button to turn on the backlight. It will notturn the monitor off or change the C/ F setting. 1. Power button 1.1 When the Monitor is turned off, press to turn on the unit. 1.2 When the Monitor is turned on, press for 3 seconds to turn off the unit. When the unit is first turned on, it performs 5 seconds countdown for Monitor warm up, then enters normal display with current CO2, temperature, and humidity readings displayed. The monitor starts taking measurements when power on and updates readings every 2 seconds. The device can t shut off alarm, if power off will come back in alarm mode and must delay. 2. Temperature Units Button 2.1 Temperature Unit Press shortly to switch two temperature units: F and C. 4

2.2 Menu and Configuration Settings By pressing the temperature button for 11 seconds, the unit enters into Menu status. There are six menu items by pressing the temperature button shortly to loop switching between AIR, N2, LX.X, HX.X, A ON/AOFF and E (exit). To change the Low and High Alarm Thresholds, switch to L0.5 or H1.0 and press the button shortly to alter between defaults, press to select, E to exit. The menu items are described in the following table: Menu Items Functional Description AIR AIR means Ambient Air Calibration. User presses the power button to implement Ambient Air Calibration (300~600ppm). N2 N2 means Nitrogen Calibration. User presses the power button to implement Nitrogen Calibration (0~200ppm). H0.5/H0.5T/H1.0/ H1.5/H3.0 Current Defaults are L.0.5 H1.0 L0.5/L0.5A/L1.0/L1.5/L3.0 A ON/ AOFF E High Alarm Threshold setup. User presses the power button to switch the high alarm threshold: H0.5 (5000 ppm), H0.5A (5000 ppm), H1.0 (10000 ppm), H1.5 (15000 ppm), and H3.0 (30000 ppm). Low Alarm Threshold setup. User presses the power button to switch the low alarm threshold: L0.5 (5000 ppm), L0.5T (5000 ppm TWA), L1.0 (10000 ppm), L1.5 (15000 ppm), and L3.0 (30000 ppm). Setting Man down alarm function on/off. User presses the power button to switch A ON (allowing Man down alarm) or AOFF (prohibiting Man down alarm). User presses the power button to exit the menu. 5

3. Calibration There are two calibration methods: Ambient Air (300-600ppm) and Nitrogen (0-200ppm). By pressing the temperature unit button for 5 seconds, the monitor will enter CO2 calibration mode. While in calibration mode, press the temperature button quickly to switch between AIR (Ambient Air Calibration) or N2 (Nitrogen Calibration). Press the power button to confirm. Zero calibration requires 100% nitrogen (0% CO2) calibration gas, a flow regulator and flexible tubing. These can easily be obtained online: https://www.co2meter.com/collections/accessories/products/demand-flow-regulator The Atmospheric calibration will not require additional materials but must be performed in outdoor (300-600ppm fresh air) during the entire procedure. See Section 2.2 Menu and Configuration Settings, to change settings. 4. Alarm Threshold There are default thresholds: 5,000 ppm CO2 (low alarm) and 1% CO2 (Short Term Exposure Limit) (high alarm). The alarm thresholds can be changed dependent on the user, to L0.5 (5000 ppm), L0.5T (5000 ppm TWA), L1.0 (10000 ppm), L1.5 (15000 ppm), or L3.0 (30000 ppm). If the measured CO2 value exceeds the define Low Alarm threshold, the alarm LED will flash red at 2Hz and the audio alarm de de de de will sound. If the CO2 level exceeds the High Alarm threshold, the LED will flash faster and the audio alarm will increase. To alert users in a noisy environment, the monitor will also vibrate. See Section 2.2 Menu and Configuration Settings, to change settings. 5. Automatic Atmospheric Pressure Compensation The displayed CO2 level is affected by atmospheric pressure or change in altitude. To insure maximum accuracy, this monitor has automatic atmospheric pressure compensation for CO2 concentrations by means of a digital atmospheric pressure sensor integrated in the unit. No calculations or maintenance is required. See Section 2.2 Menu and Configuration Settings, to change settings. 6

6. Man down alarm Falling by breathing dangerous gases can cause serious injury and even fatality to workers. If the Man down alarm function in SAN-10 is set on, SAN-10 can detect falls and send a man down alert which will activate the audible and visual alarms and alert other people in the area. The man-down detection uses a three-axis accelerometer to automatically monitor the user s movements. If a sudden fall/impact is followed by a lack of movement for 6 seconds, the alarm will sound. Turn off the alarm by pressing either of the two buttons. See Section 2.2 Menu and Configuration Settings, to change settings. 7. Reset Button Users can reset the unit by pushing a reset button through a hole on back of shell. MAINTENANCE Calibration The SAN-10 comes pre-calibrated from the factory. However, the CO2 sensor should be calibrated at least once a year, or as described in your company s safety procedures. You can perform the calibration yourself, or you can return it to CO2Meter for factory calibration at a nominal fee. The temperature and humidity sensors do not require calibration and should remain accurate for the life of your unit. Cleaning and Storage Attention: Do NOT use soap, alcohol, aromatic hydrocarbons, or chlorinated solvents for SAN-10 cleaning purposes. The front cover and case can be cleaned with a mild solution of detergent and water. Apply sparingly with a soft cloth and allow to dry completely prior to using. 7

SPECIFICATIONS Device Specifications Operating Environment Storage Power Supply Dimensions Weight 32~122 F (0~50 C), <95% RH non-condensing 14~140 F (-10~60 C), <99% RH non-condensing Li-ion battery (4.2V, 1500mAh), Micro USB cable w. Wall USB charger 3.9 x 2.0 x 1.7 in. (98x50x42mm) 4.76 oz. (135 grams) CO2 Sensor Specifications CO2 Sensor Single-beam NDIR diffusion sampling Measurement Range 5% Vol (0~50,000ppm) display Display Resolution 1ppm / 0.01% Accuracy ±200ppm or ±10% of reading Repeatability ±20ppm @ 400ppm Temperature Dependence Typ. ±0.3% of reading per C or ±4ppm per C, whichever is greater, referenced to 25 C Pressure Dependence 0.13% of reading per mmhg Response Time About 2 min for 90% of step change Warm-up Time < 5 seconds at 22 F IAQ LED Display Green: <800ppm Yellow: 800~1200ppm Red: >1200ppm Measurement interval 2 seconds Temperature Sensor Specifications Temperature Range 50~140 F (10~60 C) display Display Resolution 0.1 F (0.1 C) Display Options F/ C switchable Accuracy ±0.9 F (±0.5 C) Response Time 5~30 seconds (device must equilibrate with environment) Relative Humidity Sensor Specifications Measurement Range Display Resolution Accuracy Response Time 0~99.9%RH 1%RH ±4.5%RH <8 seconds for 63% of step change Out of range of operating conditions will impact the accuracy of the CO2 measurement. A warning will display when humidity or temperature is above the rated thresholds (>95% RH condensing, > 122 F or < 32 F). 8

TROUBLESHOOTING Cannot power on Press the Power Button for more than 0.5 seconds. Check that the Li-ion battery is charged. If monitor is charged but will not turn on, contact support. Slow response Power cycle Verify Unit Readings do not change Confirm the monitor has sufficient charge. WARRANTY The monitor comes with a one (1) year warranty starting from the date the monitor was shipped to the buyer. For more information visit our website: www.co2meter.com/pages/terms-conditions CONTACT US Support@CO2Meter.com (386) 256-4910 Technical Support CO2Meter, Inc. 131 Business Center Drive Ormond Beach, FL 32174 USA US OSHA RECOMMENDATIONS: 5000ppm TWA 1.5% (15,000PPM) 3.0% (30,000PPM) 9