NEW GENERATION. Efficient use of valuable space INCUBATORS

Similar documents
www

HettCube INCUBATORS SUSTAINABLE. ERGONOMIC. HIGH QUALITY. INCUBATOR. Find out more by visiting:

HettCube 200 / 200 R HettCube 400 / 400 R HettCube 600 / 600 R

Constant climate chambers

Thermo Scientific Heratherm Microbiological Incubators. safe. Part of Thermo Fisher Scientific

Constant climate chamber with ICH-compliant illumination

Constant climate chamber with humidity

Ultra low temperature freezers for long-term storage at -86 C UF V 500, UF V 700

Thermo Scientific Heratherm Microbiological Incubators. safe easy efficient

creating the right atmosphere NEW SERIES Galaxy Plus 170 litre CO 2 Incubators Advanced design for optimum results

Constant climate chambers

Climate chambers with illumination and humidity The BINDER KBWF series shines with its

ULTRA.GUARD ultra low temperature freezer

Vacuum drying oven for non-flammable solvents

Drying and heating chambers

Constant climate chambers

Refrigerators and freezers Research and laboratory 2018

Environmental simulation chamber for complex alternating climate profiles

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

Ultra low temperature freezers -45 o C & -86 o C Upright & Chest 370 to 830 liter

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

CLIMATRON GROWTH CABINETS

Standard-Incubators. Avantgarde.Line BD BF series. Classic.Line B BD BF series. Solid.Line BD-S series

Igloo. Ultra low temperature freezers -45 o C & -86 o C Upright & Chest 370 to 830 liter

Constant climate chambers. KBF 240 (E5.2) - Constant climate chamber. Performance features and equipment:

MICRO CLIMA-SERIES TM (COOLED) INCUBATORS AND WALLS

Plasma Freezer with air circulation TC 516 acc. to DIN 58375

VWR symphony CO 2 INCUBATORS

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

Model KBF 240 Constant climate chambers with large temperature / humidity range

Drying and heating chambers. Series ED FD FED FP M

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Thermo Scientific Heratherm Microbiological Incubators

Internet. Climate rating definitions. Customer service.

Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40

Thermo Scientific Heratherm Microbiological Incubators. Safe, easy and efficient

VACUUM HEATING AND DRYING OVENS Gentle and safe

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

EC 160 CO 2. Incubator

Thermo Scientific Heratherm Heating and Drying Ovens. efficient

Constant climate chambers

External Dimensions: B = 750 mm D = 700 mm H = 2100 mm. Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm. Temperaturerange: 2 C to 20 C

Model KMF 115 Constant climate chambers with expanded temperature / humidity range

Model KBF 1020 Constant climate chambers with large temperature / humidity range

Model KMF 720 Constant climate chambers with expanded temperature / humidity range

Thermo Scientific Heraeus microbiological incubators An optimal environment for your samples

Thermo Scientific Heratherm Heating and Drying Ovens. Efficient, safe and easy

Chromatographic Air circulated Refrigerator, two-door TC 603

Safety vacuum drying oven for flammable solvents

Plant growth chambers

Biological Incubators Biotech Ovens

ICP450. Compressor-cooled incubator. Product specification

incubator, the best in its class

Digital incubating/ refrigerating benchtop shakers

Protect your research

Pharmaceutical Refrigerators* and Freezers. *according to DIN 58345

Thermo Scientific Heratherm Heating and Drying Ovens. efficient safe easy. Part of Thermo Fisher Scientific

Model KBWF 240 Growth chambers with light and humidity

Thermo Scientific HERAfreeze Top and Basic Freezers Solutions for safe sample storage

TwinGuard ULTRA LOW TEMPERATURE FREEZERS SERIES

Constant climate chambers

Efficient, safe and easy

Refrigerators and freezers Pharmacy and laboratory 2016

Model CB 220 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

shak er LT-X (Lab-Therm) Space saving stackable incubator shaker

ISF1-X (Climo-Shaker)

BUSINESS SOLUTIONS. Biomedical REFRIGERATORS & FREEZERS FOR BIOMEDICAL NEEDS

-86 C ULTRA-LOW TEMPERATURE FREEZERS SERIES

Laboratory refrigerators and freezers

KMF Environmental test chamber for constant climate

shaker LT-X (Lab-Therm) Space saving stackable incubator shaker

Thermo Scientific Heratherm Heating and Drying Ovens

86 C freezers. New Benchmark. New Brunswick sets the standard for extraordinary freezer quality, support, and energy savings

CO₂ incubators. C CB series

Best Freeze Drying Solutions

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

Epsilon 1-4 LSCplus Epsilon 2-4 LSCplus

PR / MP I Laboratory / Medicine

CO₂ incubators. C CB series

Constant climate chambers

ENVAIR lab CO2 Tri-Gas Incubator

Liebherr commercial appliances can be found at specialist retailers where providing fi rst-class service and expert advice is their top priority.

CO 2. Incubators. Incubator, the first microprocessor-based system, and the first menu-driven control system, but we offer the

Ultra low temperature freezers. -40 C and -86 C. Green Line

Medical Refrigerators

Environmental Chambers. 2-Door & 3-Door Extra Large Capacity

Model C 170 CO 2 incubators with hot air sterilization


ICH110. Climate Chamber. Product specification

Environmental Chambers Series: reach-in & benchtop capacities

ICH260C. Climate Chamber. Product specification

smallest detail Laboratory refrigerators with analogue controls and spark-free interior

The right temperature worldwide NEW. LAUDA Integral XT. Professional thermostating for pilot plant and mini-plant purposes. Product information

Thermo Scientific Heraeus Heating and Drying Ovens

ICH750L. Climate Chamber. Product specification

Constant climate chambers

NEW! Thermo Scientific Revco PLUS -86 C Freezers. Protecting Your Life s Work

A Safe, Stable Environment for Culturing Cells. Easy Set-Up Control and Monitoring. Sophisticated Alarm, Security and Back-Up Systems

Pharmaceutical Refrigerators* and Freezers. *according to DIN 58345

Multi-Lab REFRIGERATORS Frigidere medicale

Transcription:

NEW GENERATION Efficient use of valuable space INCUBATORS

THE NEW HETTCUBE GENERATION Now with touchscreen and more options HettCube 600 600 R HettCube 400 400 R HettCube 200 200 R 2

EVERYTHING UNDER CONTROL Intuitive operation with the new touchscreen Get clear and concise information on your incubation process at a glance! With the new 4.3 inch touchscreen and intuitive menu dashboard, you can easily view the status of the device, as well as any alarms and events in the past 4 weeks. Any event or irregularity (such as door openings, tolerance band violations or power failures) are electronically documented in the logbook. Easy weekly programming The user-friendly touchscreen allows for uncomplicated adjustment of weekly programming without additional software directly on the device. The holiday function allows you to define additional temperature drops for your days off already months in advance. Easily determine the start time or the time period as well as the frequency of your Temperature reduction in a real-time calendar. 3

SAFETY FOR YOUR SAMPLES Flexible settings Various events and alarm functions are individually adjustable. For example: Deviations from the interior temperature can be limited individually over tolerance range limits or fixed via independent temperature safety device of Classes 3.1 and 3.2. Class 3.2 is already included in the standard version of all refrigerated HettCubes. Process reliability even in the event of a power failure With the new HettCube generation, you can keep controll over your samples even in the event of a power failure. Define by yourself two different settings options how your HettCube s should behave in the event of a power failure. Setting the period By default, the device automatically restarts at the point where the power failed. But Users can also define the acceptable length of time in the event of a power failure. Once power is restored, the HettCube will verify whether this pre-set period has been exceeded. Should this be the case, the settings will be paused and the incubator will automatically move to a Standstill (Safe) Mode. Otherwise, the unit will continue with normal operation and user settings. Setting the tolerance band Tolerance band limits and holding temperature are individually configurable. After a power failure, the HettCube checks whether there is a tolerance band violation. The HettCube then automatically adjusts to the previous configured holding temperature. If there is no violation of the tolerance band the HettCube resumes its work. Perfect conditions HettCube incubators combine the advantages of natural and forced convection to provide a stable and uniform environment for cultures. The fan is housed outside of usable space, providing higher throughputs and limiting airflow inside the incubator. Temperature is primarily maintained by radiated heat to ensure even temperature distribution and to prevent hotspots. This yields optimum growth conditions and considerably reduces the potential of samples drying out. 4

MAXIMUM USABLE SPACE SMALLEST FOOTPRINT 30 % more validated usable space Due to their gentle air flow and edge-to-edge temperature uniformity, HettCube incubators provide up to 30 % more validated usable space* than a traditional incubator with the same internal volume. *in accordance with DIN 12880:2007-05 50 % smaller footprint The HettCube s upright design requires up to 50 % less floor space than a traditional incubator with similar capacity. The spacesaving footprint allows you to nearly double your capacity by accommodating two HettCube incubators within the same footprint as one conventional incubator. Conventional incubators 360 litres of validated usable space HettCube 702 litres of validated usable space with the same footprint HettCube Gentle air flow + High-performance insulation + Small footprint = Maximum loading capacity + cost savings per m 2 laboratory space Conventional incubators Strong air flow + Bulky insulation + Large footprint = Low loading capacity + higher costs per m 2 laboratory space 5

USER COMFORT Easy cleaning The internal lining, drawers and shelves are made of stainless steel and can be readily removed for thorough cleaning and autoclaving. Maximum use of space Get higher loading capacities in less space by using the special inserts. Our rack for Petri dishes and the Loewenstein shelf, allows large numbers of cultures to be processed quickly and economically. They provide more space, clear order and a comfortable handling. Unimpeded access 1 HTS shelf with telescopic rails included! The stable telescopic rails of the Hettich Tray System (HTS) can be extended up to 70% horizontally. This allows you to reach easily the samples in every corner. Stay mobile The HettCube 400 and 600 models have castors for moving them to the desired position. Once in position they can be fixed with adjustable feet. 6

Quiet operation Our incubators are quieter than normal conversation when running, and will not increase the noise levels within your lab. A HettCube incubator has a remarkably low noise output of 44 db(a). Optimum safety The practical door-locking mechanism locks both the door and the control panel at the same time. This prevents inadvertent changes to parameters and harmful effects on samples. External connection One bushing on the rear panel (42 mm opening) for independent measurements and external devices. Fast and easy access HettCubes need only one door and do not require an inner door. This allows a true one-hand operation. A HettCube incubator will close automatically at an opening angle below 90. A magnetic mechanism assists this automatic closing. Save space The door does not require space at the side to open. This means that the incubator can be positioned in a corner or close to other lab equipment. The door hinges can easily be moved from one side of the incubator to the other. 7

HEAT COMPENSATION Reliable compensation of temperature differences between the inside and outside HettCube models react to changes in ambient conditions. Temperature fluctuations outside the incubator and energy introduced into the usable space by external equipment are compensated for immediately and actively. Heat compensation of the HettCube 200 R / 400 R / 600 R Lowest attainable temperature values upon introduction of equipment with different heat outputs. Temperature in C 45 40 35 30 25 Temperature HettCube 200 R (0 C to +65 C) Temperature HettCube 400 R (0 C to +65 C) Temperature HettCube 600 R (0 C to +65 C) The data apply for equipment with standard features. 20 15 10 5 0-5 80 120 160 200 240 280 320 360 400 Heat introduced in watts HettCubes with glass door The optional glass door enables users to check on their cultures without opening the door. 100 80 Condensation diagram for the HettCube 600 with glass door at an ambient temperature of +22 C Condensation on the outside of the glass panel Condensation on the inside of the glass panel 100 80 Relative humidity, ambient [%] 60 40 20 Condensation-free zone* Temperature inside < ambient Ambient temperature T=22 C Condensation-free zone* Temperature inside > ambient 0 0 10 20 30 40 50 60 60 40 20 0 Relative humidity, inside [%] Internal temperature [ C] *Condensation possible in the boundary areas 8

LOW ENVIRONMENTAL IMPACT Minimal operating costs Our HettCubes heat or cool only when needed. At an operating temperature of 37 C a HettCube incubator consumes less than 0.05 kwh. This brings average savings of up to 450 Euros annually*. Therefore, investment costs are recouped within shorter time. The use of a HettCube incubator saves on average up to 940 kg of CO 2 emissions annually*. Additionally: The insulation of the HettCubes consists of water-driven foam, which contains no fluorinated hydrocarbons. Their GWP value (Global Warming Potential) is a thousand times lower than that of conventional insulating foams. *Assuming 24h operation 365 days a year. The basis for calculation is 0.29 per kwh the average price of electricity in Germany in 2018 and 0.6 kg CO 2 per kwh. First-class isolation The advanced control system and insulation mean that the incubator will maintain a set temperature even if there is only a difference of 1 K ( C) from the ambient temperature. This allows an uncooled HettCube incubator to be used in situations in which a comparable incubator would require cooling. PROVEN QUALITY Certifications Hettich products comply with all applicable safety regulations, carry the TÜV seal and are compliant with IvD. Hettich manufactures according to the applicable quality and environmental management systems, including ISO 9001, ISO 13485 and ISO 14001. CERTIFIED ISO 13485 Each HettCube is temperature validated before delivery by means of the 9 point measurement and recieves a HettCert factory certificate, included free of charge. All temperature data are determined according to DIN 12880: 2007-5. 9

TECHNICAL DATA Temperature range for incubators cooled incubators HettCube 200 200 R HettCube 400 400 R HettCube 600 600 R 1 K above ambient temperature up to +65 C 0 C up to +65 C 1 K above ambient temperature up to +65 C 0 C up to +65 C 1 K above ambient temperature up to +65 C 0 C up to +65 C Exterior dimensions (without bushing and door handle) W x D x H in mm 710 x 825 x 970 710 x 825 x 1425 710 x 825 x 1990 Interior dimensions W x D x H in mm 535 x 690 x 420 535 x 690 x 850 535 x 690 x 1415 Internal volume in litres 150 310 520 Validated usable volume in litres 82 199 351 Percentage validated usable volume / internal volume 54 % 64 % 67 % Footprint in m² 0,6 0,6 0,6 Weight in kg 92 103 117 128 164 175 Number of trays provided as standard 2 (1 standard + 1 HTS) 3 (2 standard + 1 HTS) 4 (3 standard + 1 HTS) Temperature fluctuation at +37 C ± 0,1 K ± 0,1 K ± 0,1 K Temperature uniformity at +37 C ± 0,2 K ± 0,2 K ± 0,2 K Temperature uniformity at +25 C ± 0,1 K ± 0,1 K ± 0,1 K Recovery time after door has been opened for 30 s at +37 C 3 min 4,5 min 5,5 min Energy consumption at +37 C 0,045 kwh 0,046 kwh 0,056 kwh Noise level 41 db(a) 44 db(a) 41 db(a) 44 db(a) 41 db(a) 44 db(a) Power supply 220 240 V 1 ~ / 50 60 Hz 220 240 V 1 ~ / 50 60 Hz 220 240 V 1 ~ / 50 60 Hz Catalog No. 62000 62005 64000 64005 66000 66005 120 V 1 ~ / 50 60 Hz 62000-01 62005-01 64000-01 64005-01 66000-01 66005-01 Weight in kg* 97 108 122 133 169 180 Energy consumption at +37 C* 0,04 kwh 0,05 kwh 0,06 kwh Noise level* 42 db(a) 44 db(a) 42 db(a) 44 db(a) 42 db(a) 44 db(a) Other voltages on request. *All other data are the same as for the product versions with standard voltage (220 240 V 1~ / 50 60 Hz). All temperature values were ascertained at an ambient temperature of + 22 C in accordance with DIN 12880:2007-5. The data apply for incubators with standard features. 10

MORE OPTIONS AND ACCESSORIES NEW NEW NEW Switchboard Rack for petri dishes Rack for Loewenstein application Cat. No. Shelf (Set) Made of stainless steel, with standard rails, max. load (kg): 50 60001 Shelf (HTS-Set) Made of stainless steel, with telescopic rails, pull out up to 70 %, max. load (kg): 40 60031 Drawer (HTS-Set), High 30 mm Made of stainless steel, with telescopic rails, pull out up to 70 %, tightly welded, max. load (kg): 40 60024 Drawer (HTS-Set), High 65 mm Made of stainless steel, with telescopic rails, pull out up to 70 %, tightly welded, max. load (kg): 40 60025 Drawer (HTS-Set), High 105 mm Made of stainless steel, with telescopic rails, pull out up to 70 %, tightly welded, max. load (kg): 40 60026 Rack (HTS-Set) For Petri dishes, stainless steel, with telescopic rails, pull out up to 70 %, Petri dishes Ø (mm): 90, max. load (pcs): 90 60038 Rack (Set) For Petri dishes, stainless steel, with standard rails, Petri dishes Ø (mm): 90, max. load (pcs): 90 60039 Rack For Petri dishes, stainless steel, Petri dishes Ø (mm): 90, max. load (pcs): 90 60040 Rack (HTS-Set) For inclined storage of cultures (Loewenstein), stainless steel, with telescopic rails, pull out up to 70 %, inclination angle: 5, tube Ø (mm): 15-20, max. load (pcs): 81tube 60036 Rack (Set) For inclined storage of cultures (Loewenstein), stainless steel, with standard rails, inclination angle: 5, tube Ø (mm): 15-20, max. load (pcs): 81 tubes 60037 Rack For inclined storage of cultures (Loewenstein), stainless steel, inclination angle: 5, tube Ø (mm): 15-20, max. load (pcs): 81 tubes 60041 Frame L, 16-place Made of stainless steel, for inclined storage of cultures, tube Ø (mm): 15-20, Tube length (mm): 100-125, inclination angle 5 or 20 60027 Frame XL, 16-place Made of stainless steel, for inclined storage of cultures, tube Ø (mm): 15-20, Tube length (mm): 126-170, inclination angle 5 or 20 60028 Switchboard 4-fold socket strip, as a unit controllable via display, on the back of the device 60521 Independent PT 100 sensor For independent temperature measurement, four-wire system, temperature values output with 4 pole connection on the back of the device 60504 Independent PT 100 sensor For independent temperature measurement, four-wire system, temperature values output with analogue output 4-20 ma on the back of the device 60503 Glass door All-glass outer door, for HettCube 200 200 R 60030 Glass door All-glass outer door, for HettCube 400 400 R 60029 Glass door All-glass outer door, for HettCube 600 600 R 60013 Access port Ø (mm): 22, Foam stoppers 60006 Access port Ø (mm): 42, Foam stoppers 60007 Access port Ø (mm): 67, Foam stoppers 60008 Stacking kit For safe stacking of two HettCubes 200 200 R 60009 Rolling cabinet Lockable, with one drawer, incl. lockable castors, WxDxH (mm): 770x500x550, for HettCube 200 200 R 60010 11

EXTENSIVE STANDARD EQUIPMENT 4.3 inch touchscreen: - Target / actual display - Real-time calendar - Timer - 12/24 hour clock? - Language options (English, German, French and Spanish) - Week programming with holiday function - Log (door openings, alarms and operating hours) - Temperature diagram in 3 zoom levels (up to 4 weeks) - Setting accuracy 0.1 C - PIN lock - Door alarm individually adjustable - Temperature selection monitor class 3.1 for all models - Temperature selection monitor class 3.2 for all refrigerated models - Power failure scenarios - Programming external devices via switchboard (option) - Up to 99 program functions (Start/Stop, Period, Timer at start, Timer at temperature,...) Control panel and door lockable simultaneously USB service interface Bushing on rear panel Ø 42 mm Potential-free alarm output Interior of high-quality stainless steel (W-St 1.4301 (ASTM 304)) In addition you get for free... Up to 3 Shelf standard shelves of stainless steel (depending on model size) HTS shelf of stainless steel with telescopic rails Factory certificate (HettCert) - 9 points measurement analog to DIN 12880: 2007-05 Compensation for unneeded standard shelves* * Choose other shelves / drawers as standard, we credit you the price of unused standard inserts. P66000GB.0618 by Andreas Hettich GmbH & Co. KG, 78532 Tuttlingen Printed in Germany Design, form and colour modifications reserved. Andreas Hettich GmbH & Co. KG Föhrenstr. 12 78532 Tuttlingen Germany info@hettichlab.com Phone 07461 705-0 www.hettichlab.com