IMPERIAL FIRES CAST 1 / 2 INSTRUCTIONS IMPERIAL FIRES LTD. SAXON BUSINESS PARK HANBURY ROAD STOKE PRIOR BROMSGROVE B60 4AD

Similar documents
Imperial Electric Fires

Imperial Electric Fires

Installation and Maintenance Instructions XPG144/145/146 Electric Fires

Installation and Maintenance Instructions XPG170 Electric Fires

Model 1174 Electric Heater User instructions for LED effect 2kw Inset Heater

INSTALLATION & USER INSTRUCTIONS

INSTALLATION & USER INSTRUCTIONS

Installation & Operating Instructions. Models: York Midi & Serrano Electric Stoves

INSTALLATION & USER INSTRUCTIONS

Use & Care Manual Inset Electric Fires

INSTALLATION AND USER INSTRUCTION GUIDE. Model (s) Electric Heater Model No s FRER**ME2 / FSER**ME2 / FMER**ME2. ** Denotes case colour / finish

ELECTRIC WALL HANGING FIREPLACE SUITE FUI0005_V2_ USE & CARE MANUAL

Emberglow COAL EFFECT BALANCED FLUE GAS FIRE

INSTALLATION & USER INSTRUCTIONS

Conception Wall Fire. Instruction Manual THE SCIENCE BEHIND CLEAN.

Installation & Operating Instructions. Models: Desire, Ignite & Hereford Electric Stoves

IMPORTANT- RETAIN FOR FUTURE REFERENCE CALL:

INSTALLER AND OWNER GUIDE

USE & CARE MANUAL INSET ELECTRIC FIRE WITH DOWNLIGHTS. CO9145 V1_140812

INSTALLATION & USER INSTRUCTIONS

Contact Details. Please note that some of the contact details on this PDF document may not be current.

WALL HUNG FIRE Model: LDBL2000A-DD4BR Ref:22217

Mini Tower Fan NSMTF-18

User Instructions for Remote Controlled 2kW Rotisserie Effect Fan Heater Model 1276

USE & CARE MANUAL COMPACT ELECTRIC FIREPLACE SUITE. CO9158 V1_301012

INSTALLATION & USER INSTRUCTIONS

IMPORTANT- RETAIN FOR FUTURE REFERENCE CALL:

Kalahari DECORATIVE FUEL EFFECT GAS FIRE

AMBION FLAME. INSTALLATION AND USER INSTRUCTIONS

Contact Details. Please note that some of the contact details on this PDF document may not be current.

SP1 Wallfire. SP2 Wallfire. SP3 Wallfire. SP8 Wallfire AUS/NZ. 08/19282/2 (AUS & NZ) Issue 2

DEVIL CERAMIC SPACE HEATERS

OWNER S GUIDE ETERNITY. MODEL 540C (GC No ) INSET BALANCED FLUE GAS FIRE

USE & CARE MANUAL CONTEMPORARY ELECTRIC FIREPLACE SUITE. CO9144 V3_080714

INSTALLATION & USER INSTRUCTIONS

Installation and Maintenance Instructions XPG170e Electric Fires

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Installation Instructions & Operating Manual IMPORTANT

Mesina Fires GLASS FRONT VENTED Model No. M 70

(SP4) SP420 (SP5) SP520 (SP9) SP920 AUS/NZ. 08/50019/5 Issue 5

Installation & User Instructions:

Use & Care Manual Contemporary Electric Fires

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Kalahari RC & Camber RC

HARTFORD SLIM ASSEMBLY INSTRUCTIONS. IMPORTANT - RETAIN FOR FUTURE REFERENCE - READ CAREFULLY.

INSTRUCTION MANUAL. This product is only suitable for well insulated spaces or occasional use.

Use & Care Manual Electric Portrait with remote control DBL-2000-DD5

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS

CORELLI Micro Fireplace Assembly Instructions Model: MCFP15CRO

Model 801 With Adorn, Icon, Visage, Elegant or Ultimate Fireslide fronts & Model 802 Ultimate, Cosyflame, Fyrside, Nebula & Pizzazz versions

YOUR SAFETY & INSTRUCTION MANUAL PLEASE READ CAREFULLY HAIR DRYER MODEL C80004

INSTALLER AND OWNER GUIDE

Contact Details. Please note that some of the contact details on this PDF document may not be current.

YOUR SAFETY & INSTRUCTION MANUAL PLEASE READ CAREFULLY HAIR DRYER MODEL C80002

Refresh & Clean Carpet Washer

Glass Chimney Hood. Installation & User Instructions Please keep for future reference

Installation & User Instructions: Model: e600s e600gf e700s e1000s e1000gf e1030gf/2/3 e1500gf/2/3

INSTALLER AND OWNER GUIDE. Model 807. Electric Heater. Fitted with one of the following fascia

Pie Warmer. Instruction manual. Model: GF454-A/GF455-A

CORDLESS KETTLE KBX3016/KBX3016.C/KBA3014-2/KBE3014-2

50L/D DEHUMIDIFIER. Model Number: IG9805 INSTRUCTIONS FOR USE

Saletto. Operating Instructions. Low Profile Panel Heaters Models: LPP050 LPP075 LPP100 LPP150. A world of expertise

Your Blast Vac Pro. Your Blast Vac Pro

SP16. 08/50740/1 (UK) - Issue 1

2 IN 1 JUICER AND BLENDER

IMPORTANT SAFEGUARDS Ensure that your mains supply voltage is the same as that marked on the underside of your kettle.

OPERATING & MAINTENANCE INSTRUCTIONS

Installation & User Instructions: Model: Arizona/Broadway/Corsano/Compton/Compton1000/Corbiere/Empire /Newark/Newark1000/Qube/Tribeca

Safety Warnings & Advice 3 Your Blast Vac Pro 4 Care & Cleaning 13 Using Your Vacuum 8 Troubleshooting 14 Guarantee 14 Technical Information 15

Electric Riva Flame-Effect Cassette Fire

"Let's provide you with a superior User Experience delivering Ease-of-Mind."

2kW UPRIGHT FAN HEATER INSTRUCTIONS FOR USE

INSTRUCTIONS AND WARRANTY

CERAMIC HEATER MODEL NO: DEVIL 350B 230V/110V OPERATING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS GC ISS 1

USE & CARE MANUAL. ELECTRIC FIREPLACE SUITE (remote control operated) ADI0010 V

26 FIREBOX EN RU UA FR

MODEL 466 Radiant / Convector Gas Fire Black Beauty

PTC Tower Heater. Instruction Manual THE SCIENCE BEHIND HEAT.

BWT6.3GL Cooker Hood 60 cm Glass chimney hood

INSTALLATION & USER INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS

Contact Details. Please note that some of the contact details on this PDF document may not be current.

OIL FILLED RADIATOR Instruction manual

Vacuum Cleaner MC-E3003 MC-E3001. Operating Instructions. Model No.

EZT90BL Extractor. Installation, Use and Maintenance.

Compact Cyclonic Bagless Upright Vacuum Cleaner

Apex Lux Arcus Inset Electric Fire

Polti S.p.A. reserves the right to change equipment or accessory specification without prior notice.

JUNEAU JUN. 08/51193/0 Issue 0

Safety and Instruction Manual

INSTALLATION & USER INSTRUCTIONS

Fly Killer Instruction Manual

BT16.4SS-HK BT19.4SS-HK Cooker Hood

/04.14_00. De Longhi Appliances via Seitz, Treviso Italia

ULTRASONIC HUMIDIFIER MODEL# BU6000 INSTRUCTION MANUAL

PERFORMANCE SLIMMING BELT

INSTALLATION & USER INSTRUCTIONS

A4 Laminator. Installation & User Instructions Please keep for future reference 908/6197

Operating Instructions

ELECTRIC FIREPLACE with Remote Control

Transcription:

IMPERIAL FIRES CAST 1 / 2 INSTRUCTIONS IMPERIAL FIRES LTD. SAXON BUSINESS PARK HANBURY ROAD STOKE PRIOR BROMSGROVE B60 4AD TELEPHONE : +44(0)1527 556700 FAX : +44(0)1527 577900 E-mail : sales@imperial-fires.co.uk 100949 Rev C

IMPERIAL FIRES LTD. BROMSGROVE, ENGLAND. B60 4AD. TELEPHONE: 01527 556700 PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN FOR FUTURE USE Your IMPERIAL electric fire has been made with great care. Here are some instructions for cleaning and maintenance, which will help you to keep your fire in good condition for many years. If you experience any parts or service problems, contact either your retailer or IMPERIAL FIRES LTD. WARNING: THIS APPLIANCE MUST BE EARTHED DO NOT COVER OR HANG CLOTHES, TOWELS Etc. OVER OR NEAR THE HEATER AS THIS COULD CAUSE OVER HEATING AND POSSIBLE DAMAGE! THE GUARD USED ON THIS APPLIANCE CONFORMS TO BS1495: 1991 AND SATISFIES THE HEATING APPLIANCES (FIREGUARDS) (SAFETY) REGULATIONS 1991. THE GUARD IS TO PREVENT RISK OF FIRE OR INJURY FROM BURNS AND SHOULD NOT BE PERMANENTLY REMOVED. IT DOES NOT GIVE FULL PROTECTION FOR YOUNG CHILDREN OR THE INFIRM. THIS APPLIANCE MUST NOT BE LOCATED BELOW A SOCKET OUTLET DO NOT USE THIS HEATER WITH A THERMAL CONTROL, PROGRAMME CONTROLLER, TIMER OR ANY OTHER DEVICE WHICH SWITCHES THE HEATER ON AUTOMATICALLY, SINCE A FIRE RISK EXISTS IF THE HEATER IS COVERED OR DISPLACED. DO NOT USE THIS HEATER IN THE IMMEDIATE SURROUNDINGS OF A BATH, SHOWER OR A SWIMMING POOL. THIS APPLIANCE IS NOT INTENDED FOR USE BY YOUNG CHILDREN OR INFIRM PERSONS UNLESS THEY ARE ADEQUATELY SUPERVISED BY A RESPONSIBLE PERSON TO ENSURE THAT THEY CAN USE THE APPLIANCE SAFELY. THE APPLIANCE SHOULD NOT BE TAMPERED WITH. YOUNG CHILDREN SHOULD BE SUPERVISED TO ENSURE THAT THEY DO NOT PLAY WITH THE APPLIANCE. 1

GUARANTEE ITEM NO. DESCRIPTION QUANTITY A LH Infill Plate 1 A1 LH Infill Plate Angle 1 B RH Infill Plate 1 B1 RH Infill Plate Angle 1 C Canopy Fixing Plate 1 Screws 10 The product is guaranteed against faulty parts or workmanship for 12 months from the date of purchase please retain you proof of purchase slip. Elements and bulbs are considered to be consumable items. USER'S INSTRUCTIONS Before connecting the fire check that the supply voltage is the same as that stated on the fire. This appliance must only be used on AC supply. Fuse rating 13 amps. This appliance must be positioned so that the plug is accessible. If the supply cord of the appliance is damaged it must be replaced by a competent electrician or similarly qualified person. The appliance must be connected to a fused isolating switch if it is to be installed as a fixed appliance. ELECTRICAL CONNECTIONS - UNITED KINGDOM ONLY This appliance must only be connected to 230 / 240 V. a.c. 50Hz Supply. WARNING THIS APPLIANCE MUST BE EARTHED Green & Yellow - Earth Blue - Neutral Brown - Live As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows: The wire that is coloured green & yellow must be connected to the terminal in the plug which is marked with the letter E or by the earth symbol or coloured green & yellow. The wire that is coloured blue must be connected to the terminal that is marked with the letter N, or coloured black. The wire that is coloured brown must be connected to the terminal that is marked with the letter L, or coloured red. If the terminals of the plug are unmarked, consult a qualified electrician. Two pin plugs must not be used. FOR FUSED PLUGS USE A 13 AMP FUSE. 2

POSITION This appliance should be positioned on a firm level surface. We do not recommend its use on rugs or carpets. If the fire is to be positioned in a fire surround, the customer should establish the suitability of the surround for use with an electric fire. CLEANING & MAINTENANCE BEFORE ANYTHING, DISCONNECT THE PLUG FROM THE WALL SOCKET. SCREEN CLEANING The nature of the screen material can cause static, it is very important that any cleaning preparation used on the front screen (in front of the flame effect) contains anti - static properties. BRASS & OTHER DECORATIVE PARTS Under no circumstances use an abrasive cleaner on brass, "silver" (polished aluminium) and gold finishes. Such use will cause permanent damage to the appearance of your fire. FITTING THE FIRE TO THE FIREPLACE 1. Position the fire in the fireplace by tilting the fire backwards (to fit under the canopy) then sliding the base backwards until the infill plates are level with the side of the fireplace (See Fig. 4.) (It may not be possible to position the Fire Fret directly against the fireplace with some installations please contact you dealer for advice) 2. Adjust the infill plates to the sides of the fireplace. (See Fig. 4) 3. Tighten all screws 4. Refit the Fuel Effect PLEASE NOTE When using the fan heater you MUST remove the ashpan and any other objects that may interfere with the heater. Failure to do this will result in the fire cutting out. Fig 3 Fig 4 All brass (and polished aluminium) has been lacquered to prevent tarnishing and maintain a lustre appearance. It is important to use care in cleaning. Dusting or wiping with a damp cloth is recommended in order to preserve the lacquered finish. If a lacquered surface does eventually wear thin (possibly due to vigorous cleaning over a long period), then tarnished surfaces may occur. In such cases, the lacquer can be completely removed using a cellulose lacquer remover. The brass can then be cleaned in the normal manner and, if desired, re lacquered using either a "brush on" or aerosol cellulose lacquer. The manufacturer will be pleased to quote for re-polishing and lacquering. 3 6

ASSEMBLY OF INSTALLATION KIT 1. Check that all components shown in Fig. 1 are present 2. Remove the Fuel Effect from the front of the fire by releasing the two screws towards the rear of the fuel effect (see Fig. 2.) 3. Attach item C to the fire using two of the fixing screws provided (See Fig. 2.) 4. To ensure optimum fitting into the fireplace decide which side plates are the most suitable for the installation. PLATE A & B are suitable for standard width fireplaces PLATE A1 & B1 are suitable for wider fire places 5. Attach side plates A & B (or A1 & B1) to the fire by inserting two screws through the side flanges into the fixing holes at the bottom of the fire. (See Fig. 3.) 6. Attach the Canopy D to plate C and with the remaining screws fix RH and LH Infill Plates to the canopy. (See Fig. 2.) Fig 1 Fig 2 FUEL EFFECTS Coal and log effects can be vacuumed to remove dust, they may also be washed from time to time in warm soapy water. DO NOT replace on the fire until they are completely dry. All inset fires are supplied with a bag of real coal which should be placed on the moulded coal effect to provide a realistic open fire look. OPERATION FIREFLAME FIRES HEAT FLAME CONTROL The 3 pole switch on the fan heater provides 1000 and 2000 W of fan heat. To run the flame effect only, depress the first switch on the left. The fret and ashpan cover can be left in place during flame effect use only. Depress the left and middle switches for 1000W of heat, depress all 3 switches for 2000W of heat The ashpan cover at the bottom of the fret MUST be removed when the fan is used for heating. CHANGING BULBS Remove the ashpan cover and grate. Remove any loose coal from fuel effect. Remove the two screws from the rear coal effect. Lift the fuel effect clear of the fire this will then give access to the two 40w (MAX) 230/240v clear candle lamps. INSTALLATION INSTRUCTIONS ENSURE THAT THE POWER SUPPLY TO THE FIRE IS SWITCHED OFF. Do not tighten any fixing screws until the fire is installed in the fireplace. The fire is adjustable to two height settings, in order to reduce any gaps that may be seen at the top of the fire when installed. Before fitting any components decide which height setting is required and fit components accordingly. 5 4