FAAST. Fire Alarm Aspirating Sensing Technology

Similar documents
FAAST. Fire Alarm Aspirating Sensing Technology

FAAST. Fire Alarm Aspiration Sensing Technology

Notifier by Honeywell: FAAST TM Fire Alarm Aspiration Sensing Technology

Notifier by Honeywell: FAAST TM Fire Alarm Aspiration Sensing Technology

Aspir A ation spir P R O D U C T S

Aspirating Smoke Detection PRODUCTS. Accessories Piping Conventional and Intelligent Detectors

FAAST PRODUCT RANGE Aspirating Smoke Detection

Aspirating Smoke Detection PRODUCTS. Accessories Piping Conventional and Intelligent Detectors

Aspiration Detection.

and Aspirating Smoke Detection

FAAST Beyond Standard Methods of Detection

Flexible Air-sampling Smoke Detection

Aspirating Smoke Detection for Duct Monitoring

HART XL High Sensitivity Smoke Detection

HART XL High Sensitivity Smoke Detection

1.1 SCOPE 1.2 APPROVALS. A. The Aspirating Smoke Detector shall be tested, approved and/or listed by: 1.3 CODE, STANDARDS, AND REGULATION

Open-area Smoke Imaging Detection (OSID)

Open-area Smoke Imaging Detection (OSID)

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0111E FL0112E FL0122E. 367 mm.

Aspiration Systems for Smoke Detection

LaserFOCUS VLF-250 Engineering Specification

FDA241, FDA221 Siemens ASD

Why Hart XL Aspirating Smoke Detection?

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE ADDRESSABLE FAAST LT MODELS MI-FL2011EI, MI-FL2012EI AND MI-FL2022EI

Open-area Smoke Imaging Detection (OSID)

ASPIRATING SMOKE DETECTION SYSTEMS

465 ma, All relays active, all alarm levels displayed

Intelligent Earliest Warning Aspirating Fire Detector

FDA241, FDA221 Siemens ASD

Open-area Smoke Imaging Detection (OSID)

FAAST 7100X INSTALLATION AND MAINTENANCE INSTRUCTIONS. Document Colour Code Key: (refer to Page 28) SPECIFICATIONS: TABLE OF CONTENTS

Aspirated Smoke Detectors

Intelligent addressable fire alarm control panel

The Next Generation of VESDA Aspirating Smoke Detection Technology

FAAST XT 9400XA Fire Alarm Aspiration Sensing Technology

TrueAlarm Analog Sensing

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors.

RESET + Password Enter (During Auto Speed Procedure) Maintenance Timeout or after TEST + RESET + DISABLE (No Need for Device to Initialize)

I N T E L L I G E N T A S P I R A T I N G. Intelligent Aspirating Fire Detector. Intelligent Earliest Warning Aspirating Fire Detector

Installation and Operation Manual

Engineering Specification Guide VESDA-E VEP

-Industrial. W hen All Else Fails... Difficult Applications. The Only TRULY Industrial Air Sampling Detector For Hostile and Difficult Environments

SPEED, STABILITY, & RELIABILITY N EW! IntelliQuad TM PLUS Combination Smoke and Carbon Monoxide (CO) Detector

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

Buys Time. Aspirating Smoke Detection

Buys Time. Aspirating Smoke Detection

Aspirating Systems. Ducts. System Sensor Design Guide

FAAST XS 7100X Fire Alarm Aspiration Sensing Technology

Desigo Fire Safety intelligent detectors for complete safety

TX7130. Conventional Reflective Beam Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

The World s No. 1 Brand of Aspirating Smoke Detection

TrueAlarm Smoke Detectors

Security Alarm Systems

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

The World's No. 1 Brand of Aspirating Smoke Detector

(68.52) X. June 2000 supersedes February vigilon ADVANCED FIRE DETECTION & ALARM SYSTEMS

Solution F2. Fire Alarm Control Panels one step ahead.

FAAST LT SET-UP AND TROUBLESHOOTING GUIDE. CONTENTS Introduction...1 Wiring up a FAAST LT unit...1. Setting the Fan speed...7

Aspirating Smoke Detection for Large Area Coverage Applications

Cerberus PRO intelligent fire protection. A comprehensive portfolio of innovative and industry-leading technology.

AnaLASER II Detector. Protection Systems. A UTC Fire & Security Company. High-Sensitivity Smoke Detector (HSSD ) FEATURES DESCRIPTION

Quick Selection Guide Analog Addressable Fire Systems

Evolution Analogue Addressable Fire System

Product Description...3 Communication Interface...4 Client Interface...4. Accessible Registers...4 Data Format...4

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

AUTROSAFE. An interactive fire detection system for larger vessels

LASER ASPIRATED SMOKE DETECTOR

The World's No. 1 Brand of Air-sampling Smoke Detector

ACTIVE INFRARED BARRIER

Motorised Infrared Optical Beam Smoke Detector. User Guide

The World's No. 1 Brand of Aspirating Smoke Detector

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

ACP10 & ACP50 Security Systems

Motorised Infrared Optical Beam Smoke Detector. User Guide

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

PROPOINT PLUS ASPIRATING SMOKE DETECTION SYSTEM

FIRERAY 5000 range USER GUIDE

COMPANY PROFILE Technoswitch with its headquarters, manufacturing and training facilities in Johannesburg, has been supplying and providing technical

G SERIES: Security INTEGRATION as you want it. Greater expansion, communication, video integration, system resilience, and automation.

WIRELESS ALARM SYSTEM CR200 >SMART GPRS INTRUSION DETECTION PLUG & PLAY FUNCTIONS SELF-LEARNING, SMART FEATURES TEXT ZONE NAMING

Multi-Point Peripherals

SmartLine Pressure Transmitters Modular, Accurate and Robust for the Lowest Cost of Ownership

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

/ / White Paper. Focusing on user experience

AUTROSAFE 4 A new level in interactive fire detection systems

Consultant Specification AGILE Wireless Fire Detection System

SmartAlarm Annunciator

>WIRELESS> ALARM SYSTEM CR200

Integrated Security Solutions

ADPRO PRO Series by Xtralis

AutroSafe interactive fire detection system AUTROSAFE. An interactive fire detection system for complex installations

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

Metal Detection. High Performance Metal Detection Delivering Efficiency and Reliability SAFELINE

Early Warning Fire Detection Engineering

TrueAlarm Analog Sensing

LEARNING SPECIAL HAZARD DETECTION TYPES

M O T I O N DETECTORS. The Paradox series of motion detectors. combines advanced features and patented. technologies to provide a high level of

LASER ASPIRATED SMOKE DETECTOR

Fixed High Volume Water Spray System fireward.co.uk

S200Plus Triple Infra Red Flame Detector Triple Waveband Infra-Red Flame Detection

Transcription:

FAAST Fire Alarm Aspirating Sensing Technology

The FAAST range FAAST 8100e FAAST LT PipeIQ Next Generation Aspiration Detection Detection for Challenging Environments 3 in 1 Design, Confi guration and Monitoring FAAST Fire Alarm Aspiration Sensing Technology is a new Very Early Warning Fire Detection solution with ground breaking immunity to false alarms. False alarm immunity with very early warning, achieving sensitivity of 0.0015% obs/m. Multiple sensitivity levels available Dual source sensing technology (blue LED & red IR laser) to identify and eliminate nuisance particulates from the detection equation Unique three-stage filtration includes an aerospacedesigned and patented wing filter to prevent particles larger than 20 microns from entering the detection chamber, a replaceable filter to remove particles which have escaped and multi-angle and multi-wavelength optics to filter nuisance particles Internet / IP connectivity enables remote monitoring and management of the full system from anywhere in the world through internet browser, smart phone or mobile device. The detector can also e-mail status notifications to multiple addresses FAAST LT extends detection coverage into areas where standard detection methods are prone to failure or false alarm, or where maintenance is difficult. Field-proven laser smoke detection providing sensitivity up to 0.06% obs/m Achieve full management and control from the panel Ultrasonic airflow monitoring to reliably detect blocked sampling pipes in changing environmental conditions Fast and easy configuration and maintenance in areas where maintenance is costly or challenging All-in-one Pipe IQ LT software provides an integrated solution for pipe network layout, system configuration and monitoring PipeIQ the all-in-one pipe design, confi guration and monitoring software guides users through system design and provides full device confi guration and ongoing system monitoring. PipeIQ is included free of charge with FAAST devices. Create simple pipe designs in only a couple of minutes using Pipe Wizard Use the Pipe by Pipe Design tool for more complex pipe networks requiring full customization Real-time event monitoring and confi guration via device s onboard Ethernet connection Access to full current, live device status and historic logs Provides flexible trend graphs, reports and data storage options Translates device status into graphical format for analysis (model dependent) Incorporates a full built-in help guide for quick and easy troubleshooting 02 All-in-one Pipe IQ software provides an integrated solution for pipe network layout, system configuration and monitoring Using PipeIQ, a designer can complete the pipe network layout, verify hole sizes and sensitivity and obtain a Bill of Material and Layout Report. 03

FAAST Delivers When very early warning fi re detection is essential FAAST puts you in control The Information You Need To Protect Your Most Critical Business Assets FAAST has one focus. To protect people, mission critical facilities and high value assets by sensing the faintest traces of smoke, in a wide range of challenging environments. FAAST is a ground breaking aspirating solution designed to deliver highly accurate and discreet early warning fire detection. Using unique dual vision technology and intuitive features that allow access to data from anywhere in the world, the product outperforms other aspirating systems on the market. Intuitive Data FAAST provides you with the data you need to manage your environment. It includes 5 alarm levels, 10 pre-alarm particulate levels and a 10-level airflow pendulum which verifies that air is flowing effectively through the pipe network. It also includes a full range of fault indications. All of this information can be read quickly and easily on the device s intuitive integral display* or through a variety of remote devices. *Multiple language cards available. See Ordering Information. Dual Vision. One Focus. FAAST s dual vision sensing technology uses a blue LED to detect a wide variety of fi res with extremely low concentrations of smoke and an infrared laser to identify nuisances (like dust) which can cause false alarms and downtime. Advanced algorithms interpret signals from both sources to meet one single focus to protect your facility, people and assets with the earliest and most accurate smoke detection available. Dual Vision. One Focus Stay Connected If there is a situation at your facility, you need to know about it instantly. FAAST s unique onboard Ethernet interface enables you to monitor the detector from any Internet browser, smart phone or mobile device with VPN capability. You can also confi gure the detector to deliver e-mail status updates to appropriate personnel. This means you will be advised of whatever you need to know to protect your facility no matter where you are. Quick Set-Up FAAST s all-in-one system confi guration and monitoring software, PipeIQ, guides you through initial pipe layout and system confi guration. Once the system is installed, it enables ongoing confi guration and system monitoring from anywhere in the world, via the Internet, using FAAST s onboard Ethernet connection. The PipeIQ software is included with FAAST. 04 05

Key Features Detection as precise as 0.0015 %/m obs. Five alarm levels and two sensitivity modes provide application flexibility Dual flow detection including both ultrasonic and electronic sensing for pipe and chamber air flow measurement A single device protects up to 2,000 square metres Advanced detection algorithms reject common nuisance conditions Patented particle separator and fieldreplaceable filter remove contaminants from the system PipeIQ software provides intuitive system layout, confi guration and monitoring all in one package Integral Ethernet interface enables remote monitoring and e-mail status updates Fault indictors provide a broad spectrum of events Unique air flow pendulum graph verifies pipe network functionality Particulate graph displays subtle environmental changes for early problem indications FAAST LT Fire detection for the toughest applications FAAST LT delivers a flexible solution for applications where standard detection methods are prone to failure or false alarm. Designed with the installer and end user in mind, the device serves a wide variety of applications where maintenance is difficult, other smoke detection methods are inappropriate due to harsh environments, or areas where aesthetics matters. Stay Connected If there is a situation at your facility, you need to know about it instantly. FAAST s unique onboard Ethernet interface enables you to monitor the detector from anywhere. 06 07

FAAST LT Delivers Features For different detection strategies choose from single, dual channel or co-operative detectors Beyond standard methods of detection A single device protects up to 2,000 m 2 High sensitivity laser optics Microprocessor controlled laser based optics delivering highest stability FAAST Applications FAAST LT s main focus is applications where standard detection is not appropriate due to harsh environments, difficult access, tamper proofi ng or complex spaces. Great Indoors FAAST LT is a reliable and flexible solution for large public areas like shopping centres, airports, or stadia where evacuations are complex. It is also ideal for warehouses where access and maintenance is difficult and standard detection is not appropriate. The device allows access to these areas, reducing the cost of maintenance. FAAST LT also provides an alternative to beam detection where smoke stratifi cation may occur. Restricted Access For areas such as prisons and public spaces where devices can be tampered with, FAAST LT can be installed outside of the protected area while air sampling points are located discreetly within. Extreme Environments FAAST LT is suitable for areas such as cold storage facilities or spaces with high-airflow, and environmental conditions outside the tolerance of typical fire detection technologies. The device can be installed in a temperate, easy-to-access location while sampling points are in the extreme environment. Quick Set-Up PipeIQ LT the all-in-one system design and configuration software, guides you through initial pipe layout and system confi guration. Once the system is installed, it enables ongoing confi guration and system monitoring via a USB connection. Technology for the Toughest Applications FAAST LT combines proven aspirating detection technologies and technical design excellence to deliver reliable smoke detection for the toughest environments.the device includes high sensitivity laser detectors, ultrasonic flow sensors, protected electronics and fully independent chambers to enable the device to reach the highest sensitivity required for Class C applications, up to 2000m 2 and Class A applications up to 150m 2. Ease of Installation and Maintenance FAAST LT is designed for efficient installation and maintenance. You do not have to worry about additional items such as brackets or relays since all of this is provided with the unit as standard. Sensors and filters are easily accessible for routine maintenance and an intuitive fault pendulum display allows rapid problem identification and solving. Ultrasonic flow detection for pipe flow measurement PipeIQ LT software provides intuitive system layout and confi guration, all in one package Fault indictors provide a broad spectrum of events Dual channel units have two completely independent chambers with individual fans, filters, sensors and monitors Unique air flow pendulum graph verifies pipe network functionality USB interface IP65 rating Efficient maintenance filters and optics Discreet Detection When aesthetics matter, such as in museums, churches or mansions, FAAST LT provides a flexible, discreet smoke detection solution that is nearly invisible to the public. At the same time, it provides early smoke detection giving more time to protect high-value items from fi re. Mission Critical * For environments such as small server rooms, where only a couple of detection points are required and the loss of downtime is extremely important, FAAST is the ideal solution. It provides early smoke detection to help facilities stay up and running 24/7 and prevents unnecessary activation of suppression systems. Single Channel Dual Channel *For larger mission critical applications consider using our FAAST product. 08 09

Tec Specifi cation Tec Specifi cation The FAAST Solution for Aspirating Detection The FAAST LT Solution for Aspirating Detection Physical Specification Physical Specification Electrical Specification s Height Width Depth Cable Access Wire Gauge Maximum Single Pipe Length Maximum Total Branched Pipe Length Maximum Air Inlet Holes Network Outside Pipe Diameter Internal Pipe Diameter Sensitivity Range Relays Event Log Communication Network Shipping Weight Electrical Specification s External Supply Voltage 33.7 cm 33 cm 12.7 cm 2.54 cm cable entry holes on top and bottom of unit 0.5-2.0mm 2 (12-24 AWG) 120m 320m 36 holes 25 mm 15-21 mm 0.0015 %/m. obs 20.5 %/m. obscuration 8 Changeover contacts, 3 AMP, programmable latching or non-latching 18,000 events stored Ethernet monitoring, 6 E-mail address alerts 5.26kg includes packing material 18-30 VDC Height Depth Width Maximum Single Pipe Length 403mm (including inlets and outlets) 135mm 356mm 100m Maximum Total Branched Pipe Length 160m per channel Maximum Air Inlet Holes 18 per channel Coverage Area up to 2000m 2 Sensitivity Range 0.07% obs/m Sounder outputs 1 per channel Interfaces USB Filtration Fan control Terminal blocks: power supply, relays, sounder outputs, external input; USB port; buttons (test, reset, disable) Standard USB cable for Type B USB connection Replaceable filter 10 programmable speeds Smoke Sensor (s) Optical laser point type External Supply Voltage 18.5-31.5 V Remote Reset Time 2s Power Reset 0.5s Avg. Operating Current Max. Average Operating Current 1 Channel Device: 170mA @ 24 VDC (excluding sounders) 2 Channel Device: 270mA @ 24 VDC (excluding sounders) 1 Channel Device: 360mA @ 24 VDC (excluding sounders) 2 Channel Device: 570mA @ 24 VDC (excluding sounders) Relay Contact Ratings 2.0 A @ 30 VDC, 0.5 A @ 30 VAC Operating Temperature Optical laser point type Humidity Range 10% to 93% (non condensing) IP Rating 65 Product Variants FL0111E Stand Alone 1 Channel 1 Detector Remote Reset Time Power Reset External monitor must be pulled low for a minimum of 100 ms 1 sec. FL0112E Stand Alone 1 Channel 2 Detector Avg. Operating Current Alarm 500 ma @ 24 VDC 650 ma All relays active, all alarm levels displayed. Voltage @ 24 VDC FL0122E Stand Alone 2 Channel 2 Detector Maximum Current Draw 650 ma Voltage at 18 VDC Environmental Specification s Operating Temperature 0 C to 38 C Sampled Air Temperature -20 C to 60 C Humidity Range 10 to 95% (non-condensing) IP Rating IP30 Coverage Area Up to 2000sq. m Air Movement 0-1,219 m/min. (20m s-1) 010 011

Honeywell Tel: +44 (0) 116 246 2000 Fax: +44 (0) 116 246 2300 Email: hlsuksalessupport@honeywell.com 140 Waterside Road Hamilton Industrial Park Leicester LE5 1TN