TOKISTAR LIGHTING INSTRUCTION MANUAL. Advantage Series. Xenon Lamp. Socket. Side View. 2.4 O.C. (60 mm) 3 O.C. (75 mm) 4 O.C. (100 mm) 6 O.C.

Similar documents
AGORA PALM UNIT TYPE A2, A2A, A2B, A2C, A2D, A2F, A2G, A2H, A2J UNIT TYPE A1 & A1-A UNIT TYPE A3-A, A3B, A3C, A3E, A3F, A3H UNIT TYPE A4, A4A

EFFICIENT LONG LIFE & ENERGY SERIES

Steam Trap. Assist Trap Radiator Trap Radiator Valve

GEZE DOOR TECHNOLOGY GEZE TS 1500 / TS 2000 / SYSTEM TS 4000 OVERHEAD DOOR CLOSERS WITH LINK ARM BEWEGUNG MIT SYSTEM

GEZE DOOR TECHNOLOGY GEZE TS 1500 / TS 2000 / SYSTEM TS 4000 OVERHEAD DOOR CLOSERS WITH LINK ARM BEWEGUNG MIT SYSTEM

HEAT EXCHANGERS. Heat Exchangers are available in 2 basics designs: 1. Conventional Coil Type Condensers. 2. Shell & Tube Type.

SYSTEM FIELD CUTTABLE SERIES

SERIES. LINE OF LIGHT (No Pixelation) FLEXIBLE DIRECT VIEW LINE VOLTAGE 150 MAXIMUM RUN LOW VOLTAGE 32 MAXIMUM RUN OUTDOOR RATED

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws

INSTALLATION INSTRUCTIONS - PS1055LCP & PS1555LCP LED EMERGENCY DRIVER PS1055LCP & PS1555LCP

LIGHT CHANNEL TRIM 1.6

Immersion Heat Exchanger. Thermosyphon Reboiler. Coil Condenser. Boiler

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS

Condensing Boiler It s a comfortable decision to make

Installation Instructions

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

INSTALLATION INSTRUCTIONS ELECTRIC DRYER

Basic DBE. Easy installation in less than two hours

Installation Instructions

THINLINE TL2 SERIES INSTALLATION AND OPERATING INSTRUCTIONS

1 x4 Dimmable LED RetroFits

Innes. Instruction Manual A Kichler Decor ceiling fan. Includes our new TM

CCS-100. Installation Manual

INSTALLATION INSTRUCTION

I-320 SERIES AC EMERGENCY LIGHTING EQUIPMENT

Mineral Insulated Band Heater

Read these instructions carefully and completely. NOTE This appliance must be properly grounded.

Installation Instructions

PRELIMINARY PRODUCT CODE TYPE LOCATION DRIVER OPTICS LENGTH WATTAGE COLOR TEMP CABLE 3 + MOUNTING. Wall Grazer. Flood 32ºx85º K E End

1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.

HPNLS-LO. Installation Manual

5DI52XXD/5DI52XXD-L Series Fan UL Model No. : 5DI52. Owner s Guide and Installation Manual

luxcontrol lighting control system SWITCH sensors smartswitch HF 5DP f Automatic switching based on motion and light level

HPNLS-RT. Installation Manual

REFLECTOR PANS FOR HINGED ELEMENTS CONNECTOR BLOCK KIT TRIM RINGS FOR ABOVE PANS CONNECTOR BLOCK RANGE CORD REFLECTOR PANS FOR PLUG-IN ELEMENTS

Installation Instructions

JLLP DESIGN AND CONSULTING

LIGHT CHANNEL.3 SURFACE MOUNT COMPLETE FIXTURE

JEDI. Powerful recessed linear LED projector. Views

ecolor Graze Powercore Linear LED surface light for wall washing and grazing

60" Lyndon Patio. Instruction Manual Customer Service :30 AM to 5:00 PM EST, Monday - Friday A Kichler Decor ceiling fan

SEE SEPARATE PARTS LIST

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

MINIATURE RECESSED LIGHTING 3 & 4 APERTURE

1. SAFETY RULES. 1. To reduce the risk of electric shock, insure electricity has been turned off at the circuit breaker or fuse box before beginning.

54" Skye. Instruction Manual Customer Service :30 AM to 5:00 PM EST, Monday - Friday A Kichler Decor ceiling fan

LIGHT CHANNEL 45 COMPLETE FIXTURE

PERIOD ARTS FAN CO. Customer Service M-F 8am - 4pm (PST)

LIGHT CHANNEL.6 MILLWORK COMPLETE FIXTURE

RAZOR RZR SERIES DIE CAST ALUMINUM LED EXIT SIGNS INSTALLATION AND OPERATING INSTRUCTIONS IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS. For Reliance Controls Emergency Power Transfer Switch Kit Model Number 30216BRK

Select. Sutter PlaceTM. Instruction Manual. A Kichler Select ceiling fan

CEILING FAN OWNER'S MANUAL

STAND ALONE DRYER BASE. Parts Manual

1094 N Main Street Ashland City, TN

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:

Claude Indirect Wall WALL

INSTALLATION INSTRUCTIONS - POWER SENTRY CONTROL POWER SENTRY CONTROL UNIT PSBCEB2 INSTALLATION INSTRUCTIONS

B C D. Strip Heaters. Channel Strip Heaters Ceramic Insulated. To order, call or shop online at omega.com SM

B C D. Strip Heaters. Channel Strip Heaters Ceramic Insulated. To order, call or shop online at omega.com SM

Easy installation in both new construction and retrofit RN80L RN110L READ AND SAVE THESE INSTRUCTIONS INSTALLATION GUIDE

Installation Instructions

Plugs & sockets. Industrial plugs and sockets Scame I-1 5. Industrial switched sockets. Scame I-4 6. Distribution boards.

Ergoline Open Sun 1050

High Performance Heater with More Efficient Heat

INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP

Orrin. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

52 Lacey LED. Instruction Manual. 6 Speed DC Wall Control System

INSTALLATION INSTRUCTIONS FOR 6636 SERIES PACKAGE AIR CONDITIONER

60" Hatteras BayTM. Patio. Instruction Manual. Includes our new Wall Control System. A Kichler Décor ceiling fan

INSTALLATION INSTRUCTIONS FOR 6536 SERIES TWO TON PACKAGED HEAT PUMP

Soltron Sea Shell XXS-35

52 DorsetTM. Instruction Manual. Basic Function Wall Control System Included. A Kichler Decor ceiling fan

1. SAFETY RULES WARNING WARNING. 8. Avoid placing objects in the path of the blades.

Installation Instructions 30 French Door Built-in Wall Ovens

RICCAR VIBRANCE VIBC.2

ATEX. Wolf Safety Lamp Company. The widest range of portable ATEX lighting approved for use in explosive atmospheres

INDICATOR LAMPS & LED REPLACEMENT LAMPS

SERIES 500. Installation & Maintenance Instructions. Ceiling Mounted Fan Forced Heater WARNING SAVE THESE INSTRUCTIONS. Recessed Mount.

SYSTEM. field cuttable LLED8000

3MAVR60XX Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3MAVR60XX

VEGETABLE CULTIVAR AND CULTURAL TRIALS 2000

JUMBO ISLAND FROZEN FOOD/ICE CREAM/MEDIUM TEMP MERCHANDISERS Low, Medium and Dual Temperature Self Serve Display Cases

CEILING FAN OWNER'S MANUAL

Ceiling Fan Installation Instructions

LED Emergency Battery Backup Installation Instructions Ordering Code: EB23UQ

Warnings 2. Installation Instructions 3. Wiring Instructions 3. Mounting Instructions 4. Replacement Element Installation 5. Replacement Parts 5

4 DEDICATED MR16 LED NON-IC SERIES SHALLOW HOUSING

6 Oz. Twin Pop. Popcorn Machine Instruction Manual Model #2666EX. Cincinnati, OH USA. Part No EX Revised June 1996

ProStar Ceiling Fan PS52. Installation Instructions Instrucciones de instalación Instructions d installation

E3Z-F. Compact Photoelectric Sensor with Built-in Amplifier. A Visible Spot That Simplifies the Usage of Photoelectric Sensors. Features.

FitchTM. Instruction Manual. Includes our Basic Function CoolTouch TM Control System Looks permanent, but goes wherever you go!

Helically wound resistance wire coil made

Running Magnet 2.0 Suspension Down High-tech LED lighting system for interior architecture

Fillmore Small Pendant Assembly and Installation Instructions

Electrical cable Water supply tube Fittings for tube Coupler Teflon tape. Hole saw min. 2½" bit

Kold Locker Walk in Standard walk in stocked for IMMEDIATE SHIPMENT

IMPORTANT SAFETY INSTRUCTIONS:

52 StarkkTM. Instruction Manual. A Kichler Select ceiling fan

CEILING FAN OWNER'S MANUAL

Transcription:

TOKISTAR LIGHTING INSTRUCTION MANUAL Avantage Series General escription Tokistar s Avantage Series is a 24 VAC lighting system using LE moules or rigi-loop xenon lamps. LEs are 0.72 watts. Xenon lamps are available at watt, watt, or watt. Xenon lamps have the voltage an rating stampe on the glass at one en. Each Avantage fixture is labele with wattage an operating voltage. The voltage an lamp rating are stampe on one en of the xenon lamps. 24/ Socket Sie View LE Moule Socket Sie View Xenon Lamp escription Light Source Watt Xenon Watt Xenon Watt Xenon 0.72 Watt LE 0.72 Watt LE Watt Cool White Xenon Watt Cool White Xenon Part No. XB-F XB-F XB-8F AVLE-WW AVLE-IW XB-FB XB-8FB Seconary Circuit Limitation The maximum loa of each fixture must not excee 480 Watts (20 amps @ 24 Volts). In aition to this limitation, consieration must be given to the effects of voltage rop. Fixtures with lower wattage lamps (such as LEs) an more istant socket spacing have recommene maximum lengths less than 480 Watts. T Seconary Circuit Limitation Each seconary circuit MUST NOT excee 20 amps (480 watts @ 24VAC) This chart gives recommene maximum lengths which take into account these two limitations. Conforming to these lengths will ensure no fixture excees 480 Watts, an will not be subjecte to excessive voltage rop. Watt/X Watt/X Watt/X8 0.72 Watt/LWW 0.72 Watt/LIW Maximum Lamps/Circuit 160 Lamps 96 Lamps 6 Lamps 400 LEs 400 LEs Lamp Spacing 2.4 O.C. (60 mm) O.C. (7 mm) 4 O.C. (100 mm) 6 O.C. (10 mm) 2 (9.6 M) 40 (12 M) 48 (14.4 M) 60 (18 M) 19 (.76 M) 24 (7.2 M) 2 (9.6 M) 48 (14.4 M) Maximum Run Lengths 11 (.6 M) 14 (4.2 M) 18 (.6 M) 28 (8.4 M) 80 (24 M) 100 (0 M) 1 (40 M) 200 (60 M) 80 (24 M) 100 (0 M) 1 (40 M) 200 (60 M) 1. Rea all instructions completely before beginning installation. 2. Turn off electricity before beginning installation.. All wiring is to be performe by a qualifie electrician. 4. Installation must comply with the National Electrical Coe, an all applicable coes.. Turn main supply to transformer on only after all connections are mae an teste. 6. Use only transformers provie by Tokistar with the system. TOKISTAR LIGHTING 101 E. iscovery Lane Anaheim, CA 92801 TEL: 714 772 700 FAX: 714 772 7014 email: info@tokistar.com Website: tokistar.com

Avantage Instructions Page 2 Step 1: Mounting Fixtures Option 1 - irect Screw Mounting (Part# AV-MS) Each LE or lamp socket, has four mounting holes esigne to accept screws. For secure mounting, use two screws in opposing holes. Sockets must be firmly attache to support the weight of the fixture., 4 an 6 socket spacing Seamless Light Avantage fixtures are flexible enough to turn corners without the use of special harware, eliminating ark spots at corner locations. 2.4 socket spacing Option 2 - Mounting Channel (Part# AV-MC) An optional mounting channel may have been provie with your materials. Screw the channel securely in place, then snap each socket into the channel. Attach screws every 8. Option 2A - Channel Clamps (Part# AV-CL) These clamps are for use with our AV-MC Mounting Channel. Screw the clamps securely in place, then snap in the channel. Attach clamps every 8. Attach screws every 8 Mounting Channel conforms to a 24 insie or outsie raius. Channel Clamp En Caps - Part# EC-WH (White) / Part# EC-BK (Black) Ens caps are attache to the en of each Avantage lighting fixture. If the fixture nees to be trimme, a new en cap nees to be attache to the en of the fixture after trimming. En Cap / Heat Consieration Xenon lamps prouce heat an will cause amage if they come in irect contact with persons or combustible materials. In accorance with NEC/NFPA 70 Article 410.11, combustible materials next to fixtures must not be subjecte to temperatures in excess of 90º C (194º F). In orer to conform to this stanar, fixtures nee to be installe accoring to the minimum space requirements shown below. 1 1 2 2 With Reflector 2.4 O.C. Watts Watts 4 Watts 1 2 1 2.. Watts 1 2 1.2 2

Avantage Instructions Page Step 2: Installing Reflectors/LEs/Lamps Installing Reflectors - Part # AVWH-REF-S (White) / Part #: AVBK-REF-S (Black) Part# AVWH-REF-A (White) / Part# AVBK-REF-A (Black) Your fixture may have been provie with optional reflectors. Symmetrical reflectors (#AVWH/BK-REF-S) must be attache before lamps are installe. Push the plastic reflector base irectly over the socket until it is firmly seate in place. Asymmetrical reflectors (#AVWH/BK-REF-A) may be attache after lamps or LEs have been installe. Silver Reflector Plastic Reflector Base Avantage Socket Installing LEs or Lamps 24/ LAMP 24/ LAMP SOCKET SOCKET 1. Push LE or Lamp into one sie of socket at an angle. 2. Push other sie of LE or Lamp straight own. o Not Twist. Lamp Replacement 1. Remove lamps from socket by pulling irectly out (o Not Twist). 2. Replace lamps only with the same or lower wattage lamp. Installing Clear Lens - Part# AV-LNS Your fixture may have been provie with clear lens covers. Push the lens irectly over the top of the socket. When properly seate between the two catches on the sie of the socket, the lens will be securely fastene an not move from sie to sie. Clear Lens En View EN VIEW FOR SHIEL Catches secure Clear Lens in place. SIE VIEW o not use the Watt lamp (part# XB-8F), or cool white xenon lamps (part# s XB-FB & XB-8FB) with the Lens Cover.

Avantage Instructions Page 4 Step : Seconary Wiring Mini Junction Box Connectors - Part# AV-JBOX If installation involves running wire through a builing structure, conuit may be require to fee the fixture. A miniature junction box is available with a 1/Ø knockout for use with conuit fittings. The terminal block insie the junction box accepts 14-8 AWG wire. All seconary circuit wiring must conform to the National Electrical Coe an all applicable coes. Remove AV-JBOX Cover Screw AV-JBOX firmly in place Install Strain-Relief Maximum 480 Watts (20 Amps) per connection AV-CONN insie AV-JBOX Terminal Block Connectors - Part# AV-CONN Avantage Series fixtures may have been provie with terminal block connectors. One en of this connector screws irectly to the Avantage fixture, an the other en accepts 14-8 AWG wire. A screw hole is provie in the center of the connector for secure mounting. AV-CONN Terminal Block T-Connection System - Part# AV-TCON Our T-Connection system can fee multiple fixtures from a single wiring harness. Female connectors are attache to the main harness at any interval an the mating male connectors attach to each en of the fixture. T-Connector When attaching wire to terminals, make certain the insulation is strippe an the connection is mae so no live conuctors are expose. Live conuctor must be within connector housing

Avantage Instructions Page Step 4: Instructions Location The maximum recommene istance between the fixture an the transformer varies, base upon the loa of each fixture an the size of seconary wire feeing the fixture. It is impossible to give a efinitive istance without consiering all the variables. Electrical engineers an contractors can calculate these istances. Shoul you nee guiance, consult the factory. Larger capacity transformers with multiple outputs can be centrally locate an fee fixtures in either irection. Input Voltage o not excee maximum fixture length o not excee transformer output rating Seconary Circuit Protection s are provie with circuit breakers to protect seconary circuits. The maximum size circuit breaker on a transformer is 2 amps, but the circuit wire to the breaker MUST NOT EXCEE 20 AMPS. There are several transformer sizes available, an ifferent size breakers installe in them. Below is a selection of transformers with their respective circuit limitations. 1000 Watt 960 Watts Max. 00 Watt 1 A Max. Loa 12. Amps 00 Watts @ 24 VAC 70 Watt 70 Watts Max. 20 Watt 1 A Max. Loa 10.4 Amps 20 Watts @ 24 VAC 00 Watt 480 Watts Max. 100 Watt 7 A Max. Loa 4.1 Amps 100 Watts @ 24 VAC s shoul be installe in an accessible location. Magnetic transformers generate heat an must be installe in locations where there is free-air circulation. Electronic transformers require less space to issipate heat, but they too shoul be installe in accessible locations with free-air circulation. For aitional information, please refer to the instruction manual provie with your transformer. Version 1.0