MANUAL SPEED SENSOR MSPEED

Similar documents
MANUAL. FLOWMETER MFlow EX

Getting Started with

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

Getting Started with

Movement Detector GJD 300

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

Alarm Control Panel WIC-16Z4P WIC-5Z2P. Installation & Operation User Manual

Connections, displays and operating elements C D E G H. Installing the control unit

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual

Section - III SYSTEMS DESCRIPTION

LeakSafe. solutions. WaterSwitch2. Installation Instructions

Understanding the Code Pad lights...4. Code Pad tones...5. Fully arming the system On MODE...6. Fully arming the system - Quick Arm MODE...

WATER HEATER ELECTRONIC CONTROLLER USER MANUAL

2G & 3G GSM Wireless Beam Alarm

Mobeye CM2410 GSM fire alarm communicator

Autoclave Operations Manual

LeakSafe. solutions. WaterSwitch2. Installation Instructions

Diplomat Inverter/Diplomat Duo Inverter

Zerio Plus EDA-D6000 Radio Combined Heat Detector and Sounder Installation Instructions

Operation manual. Rooftop Packaged Unit

PowerWizard. Level 1.0 & Level 2.0 Control Systems Training

DSC PowerSeries NEO Quick Start Guide

Pioneer-R16 Gas Monitor Operator s Manual

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

Quick start guide. English

status AW1 WiFi Alarm System Printed in China PA : AW1-UM-EN-V1.0 User Manual 2016 Chuango. All Rights Reserved.

Control/Communicator Installation Manual

Electro-Sentry. Users Manual

USER MANUAL Mobeye ThermoGuard CM2200

DEIF A/S. Description of options. Option M17, Configurable inputs and RPM supervision Engine Controller EC-1/EC-1M. Description of option

Watchguard WGAP864 User Manual

Water Tank Level Monitor

Wireless Alarm system s manual

Digiplex LED Keypads User s Manual

Fire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63

Dornier 328Jet - Lights

3D_ISS. Integrated Software System. User Guide Manual

GJD OPAL RFX WIRELESS 35 METRE EXTERNAL PIR INSTALLATION MANUAL

WHA 3000P Hot Air Station

WiFi Hints & Tips. Contents. WiFi Hints and Tips 1. Page No. Section No. Title

"Pegaso" wireless alarm system D.I.Y. wireless kit

IDM4 CARAVAN ALARM. Operating instructions

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual

CC408. Quick Reference Guide Solution 880

Installation & Operating Instructions

VISY-X. Technical Documentation. VISY-SoftView V 1.7 User Guide for VISY-Command GUI and VISY-View Touch. Edition: Version: 6 Art.

Intruder alarm panel Terxon MX Operating instructions

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

Dohse Aquaristik GmbH & Co. KG. T-Control Pro. Item no Status: 03/2013. Dohse Aquaristik GmbH & Co. KG

Interactive Fire Control Panel IFS7002 one signal loop Instruction Manual

2G & 3G GSM Portable PIR Alarm

GSM RFID VOICE Alarm System

Comfort Thermostat Function

Wireless Keypad GKP-S8M

C2 Compact Range Installation & Programming Manual

SPT & PRO PROVIDER MATERIALS

Elite. GJD022 /GJD023 35m External PIR. Multi Beam Lens Data

User manual. CTS 602 by Nilan VPL 15 VPL 15 TOP. Version: 9.02, Software-version: 2.21

Safewatch Pro 3000 System Manual

Summary of Keypad Main User Commands

ANEMOMETER 4403-RF-BAT

Alarm Control Panel WIC-16Z4P WIC-5Z2P. User Instructions

Measuring Recording Online Monitoring Regulation Alarming

GasScanner 4C. Four Channel Monitor. Operator s Manual. MINT-0280-XX Rev. A 02/25/08

Tebis application software

User Manual. Dryer Controller M720

Combustible Gas and Hydrogen Sulfide Beacon 200 Rig Monitor Operator s Manual

MANUAL FOR MJK LIQUID SAMPLER 780

G34 AU1B (External Ultrasonic Sensor) Version 3

Owners Manual Operating Instructions Patent # 7,081,811

Digiplex LED Keypads. User s Manual

PROGRAMMABLE 7-DAY RF THERMOSTAT

1. User features of the GSM dialer

Ion Gateway Cellular Gateway and Wireless Sensors

No part of this publication may be reproduced, stored in an automated data file or made public in any form or by any means, whether electronic,

WS3650IT-MG-SIL. Technical sheet

"Pegaso" wireless alarm system

Control of the system, MLP RO pump station

TPOne-B. Electronic Programmable Room Thermostat. Installation Guide. Danfoss Heating

SCAN200E USER S MANUAL

HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER

745i 3 OPERATION MANUAL TABLE OF CONTENTS

TAC-09CHSA/*** TAC-12CHSA/*** TAC-18CHSA/*** TAC-24CHSA/*** SERVICE MANUAL WALL MOUNTED SPLIT-TYPEAIR CONDITIONERS. No.TE1307.

NetworX NX-8V2. LED Keypad User Manual

AD-1272 Advanced Thermal Dispersion Probe Airflow Measuring System

4L & PRO PROVIDER MATERIALS

LS800S Intruder Alarm System. Engineering Manual

Dec Wirsbo CoSy Radio. Installation and Operating Instructions

PROGRAMMING GUIDE SPECTRA CONTROL PANELS V , 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX

For silent arm / disarm use BUTTON 2.

Controls Surface mounted pushbuttons Suitable for gloved use. Buttons Side - On/Off Front Menu Scroll Pin Hole Setup access

Table of Contents. Appendix A Special Characters 31

Beacon 800 Gas Monitor Operator s Manual

INTRODUCTION Thank you for purchasing your new Comfort-Set 90 Series thermostat. Your new White-Rodgers Thermostat uses solid state microcomputer

QUICK CONSUMER REFERENCE GUIDE

8 plus and16 plus. User s Guide * # ent. esc GALAXY 16+ V2.XX TUE 30 JUN. IU ZST 962 Issue 2. A u B u

Transcription:

MANUAL SPEED SENSOR MSPEED 1. INTRODUCTION... 2 2. DESCRIPTION... 2 3. CONNECTING MSPEED... 2 3.1 CONNECTING MSPEED TO THE JETI BOX... 3 3.1 CONNECTING MSPEED TO THE DUPLEX RECEIVER... 3 3.2 CONNECTING MSPEED TO THE DUPLEX RECEIVER VIA THE EXPANDER... 3 4. MSPEED MENU... 4 4.1 ACTUAL VALUE... 4 4.2 MIN / MAX... 4 4.3 SETTING... 4 4.4 ALARMS... 7 5. INSTALLATION... 7 6. TECHNICAL DATA FOR MSPEED... 8 7. WARRANTY... 8 Publisher JETI model s.r.o 11.6.2010

1. Introduction MSPEED is a sensor which measures the speed of a flying model through the air, to provide the indicated airspeed (IAS). The reporting of airspeed can be very instructive with regard to the control of a flying model, for example allowing the pilot to determine the models stall speed and set an alarm to indicate when the model falls below this speed. Another function of the sensor is to allow the pilot to set a desired speed and a step above or below this speed at which an acoustic signal should be sounded by the transmitter module. To facilitate easier reading of the indicated airspeed, a bar graph is displayed marking the appropriate configured steps. The measurement of airspeed is based on the principle of change in dynamic pressure, measured by a pitot tube, which is connected by silicon tubing. With the help of the wireless Duplex system, this sensor information can be reported to the pilot in realtime, allowing immediate feedback in airspeed changes and a deviations from the configured steps. 2. Description MSPEED consists of a base unit and a pitot tube with static pressure measurement, connected by silicone hoses. The base unit includes the sensor for measuring the relative pressure with two entrances. One entrance is marked red and other is clear. The pitot tube has two corresponding exists, one marked red, the other not. To ensure correct operation, the red tube should be connected between the base unit and the pitot using the marked input/output. The clear tube should be connected between the unmarked input/outputs. 3. Connecting MSPEED The base unit features two three-wire cables. The cable with the red JR plug, marked INPUT provides control signals to the unit. The other cable marked EXT (black plug) allows data transfer between the sensor and the Duplex system or the Jeti Box. -2-

3.1 Connecting MSPEED to the Jeti Box In this case, the Jeti Box requires a power-supply of between 5-8.4V, such as a receiver battery, which should be connected to the socket marked +, - of the Jeti Box. The three-wire cable from the MSPEED, with the black plug, should be connected to the appropriate socket of the Jeti Box (The socket marked pulse, +, -). The red plug of the MSPEED base unit, is not required. Please note in this configuration, alarms cannot be generated, but will be displayed on the Jeti Box screen. 3.1 Connecting MSPEED to the Duplex Receiver In this case, MSPEED is connected directly to the Duplex receiver, using the socket marked EXT. The sensor takes its power from the receiver. The black plug from MSPEED should be inserted into the EXT. Socket of the receiver (Observe correct orientation) and the red plug from MSPEED can optionally be connected to a spare channel, in order to control the alarm signals. 3.2 Connecting MSPEED to the Duplex Receiver via the Expander In this case, additional sensors can be connected to the receiver, if required, via the Expander. The three-cable wire from the MSPEED with the black plug, should be connected to the Expander, observing the correct orientation. The Expander should be connected to the Receiver via the Expanders black JR plug, into the socket marked EXT. on the Receiver. The optional red plug of the MSPEED can be connected to a spare receiver channel, if desired. -3-

4. MSPEED Menu For parameter setting and data read-outs, the Jeti Box terminal is used. After connecting MSPEED as per section 3 and assuming that if required, the Jeti Box is connected to your Duplex transmitter module; then the MSPEED sensor can be chosen on the Jeti Box. The initial screen shows the sensor identification and the actual measured speed. The second line shows the bar chart and the current speed. The bar chart has eight positions and the > character indicates a speed step, which is equal to the Step of graph value within the BAR GRAPH settings. MSPEED km/h 0.0 *MSPEED MENU* ACTUAL VALUE *MSPEED MENU* MIN/MAX *MSPEED MENU* SETTING *MSPEED MENU* ALARMS 4.1 ACTUAL VALUE MSPEED MENU: Actual Value By pressing the D (Down) key of the Jeti Box, we can see the actual measured values. Actual speed Shows the actual measured speed. Can be reset by simultaneously holding L and R keys (Left and Right), which should be performed if the model is at rest. Temperature Shows the current temperature measured by MSPEED. 4.2 MIN / MAX MSPEED MENU: MIN / MAX - By pressing the D (Down) key of the Jeti Box again, we can see the recorded extremes of speed and temperature, which have occured. Recorded extremes are automatically deleted after power-up only when the current actual speed exceeds that specified by the Setting Bar Graph Minimal Value setting. If this value is not exceeded, then the recorded extremes from the previous use of the sensor are shown. MIN/MAX Speed Shows the minimum and maximum speed recorded during the last operation. MIN/MAX Temp. Shows the minimum and maximum temperature recorded during the last operation. 4.3 SETTING MSPEED MENU: SETTING By pressing the D (Down) key of the Jeti Box again, we access the settings menu of the sensor. -4-

Erase Data By pressing the Down key, the minimum and maximum values are erased. BAR GRAPH - by pressing the Down key, the options for the bar graph are displayed Minimal value The minimum value of the graph. When this value is exceeded, the first portion of the graph is filled and any minimum and maximum values are erased. Step of graph Step of the bar graph. For example: If the Minimal value is 20 km/h and Step of graph is 10 km/h and the current speed is 51 km/h, then the bar graph will appear as follows: SPEED MONITOR By pressing the down key, we access the setttings menu for the speed indicator, which serves to aid in keeping your model at an optimum speed and aid awareness of changes in that speed. Beep of speed Set the independent audible speed indicator. This does not affect the alarm. ON Sound is switched on permanently. ON OVER Sound is only given when speed is above Setpoint speed. ON BELLOW - Sound is only given when speed is above Setpoint speed, OFF - Sound is off (Does not affect the alarm). Setpoint speed Expected average speed. Level of speed The step in speed with which the sound changes Period of beep The length of the sound Actual speed [km/h] 20 30 40 50 60 70 80 90 > > > > The graphic below shows the speed curve in relation to time. Setting the desired speed value ( Setpoint speed ) and speed levels ( Level of speed ) determines how the acoustic signal will change. If the current speed is higher than the desired speed, this is signalled by beeps and the appropriate number of tones proportional to the difference in speed. Speed below the desired -5-

level is indicated with long notes and the number of tones in this case determines the shortfall of speed. These sounds can be disabled in the Settings Control signal option menu. CONTROL SIGNAL By pressing the Down key, we can modify options relating to the input control signal. This allows simple switching on/off of the audible alarms generated by MSPEED. Trigger level Set the trigger speed for recording of data. For example if the trigger level is 1.50ms and Reverse is OFF, as soon as a speed of 1.50ms is exceeded, then data recording begins and any previously recorded maximum/minimum values are deleted. If the speed is less than the trigger level, no data is recorded and previously recorded data remains unaffected. No acoustic signalling will be given in this case. If the option SETTING SPEED MONITOR BEEP OF SPEED is set to ON and the control wire is not connected, then the acoustic signal will be switched on permanently. Revese Reverse the control signal input. MAIN By pressing the down arrow of the Jeti Box, the main menu for MSPEED is displayed, where the units of speed and alarm signal can be programmed. Speed unit Specify the unit of measurement for speed, as one of: km/h Kilometres per hour m/s Metres per second mph Miles per hour Beep speed Alarm - Set the more code letter to be represented by the Duplex transmitter module, should the speed sensor signal an alarm condition. -6-

4.4 Alarms MSPEED MENU: ALARMS By pressing the Down arrow, we can access the alarm settings menu for the speed sensor. Should an alarm condition be reached, the 2nd line of the Jeti Box (If connected) will indicate the condition and the transmitter module will emit an audible alarm according to the morse code character specified in the main settings. High speed Al. The speed which if exceeded, will raise an alarm condition. Low speed Al. The speed below which an alarm condition should be raised. 5. Installation The main MSPEED sensor unit can be placed directly in the fuselage or installed in the wings. Please avoid direct contact of heat sources, such as batteries, controllers and regulators. The pitot tube must be installed outside zones of airflow directly behind propellers. As an example, the pitot tube may be installed on the wing of a single-engined model aeroplane, or on the fuselage of a twin-engined model. In single engined models, it is advantageous to install the pitot tube at the leading edge of the wing at the chord. In twin or multi-engined models, it is best to install the pitot tube in the nose of the model or at a minimum distance of 2cm from the fuselage side. -7-

6. Technical data for MSPEED Technical Data MSPEED Sensor unit dimensions (mm) 22x25x13mm Pitot tube dimensions (mm) 54x3 mm Weight (complete) 21g Precision 5 km/h Limit 20-350km/h Operating temperature 0-85 C Operating Voltage 3,5-8,4V Current 10mA 7. Warranty A 24-month warranty is provided by the manufacturer from the date of sale on the condition that the unit has been operated within the required voltage limits and there is no physical damage. All servicing during and after the warranty period, is provided by the manufacturer. Wishing you pleasant flights: JETI model s.r.o. Příbor, www.jetimodel.cz -8-