IN-LINE CENTRIFUGAL FAN VENTS VKP PS 125. User`s manual.

Similar documents
USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

READ AND SAVE THESE INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS

Bathroom Exhaust Fan/Fluorescent Light Combination

ULTRA SILENT VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS WARNING CLEANING & MAINTENANCE OPERATION CAUTION!

Bathroom Exhaust Fan/Fluorescent Light Combination

USER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES

e Bath Fan with Light User s Guide

e Bath Fan with Light User s Guide

e Bath Fan with Light User s Guide

USER MANUAL. Frigate HRV 120 SR Frigate ERV 120 SR. Heat (energy) recovery ventilation unit

e Heater/Exhaust Fan/Light User s Guide

Easy installation in both new construction and retrofit. ZB90C ZB110C X2 Multi-Speed Ventilation Fan INSTALLATION GUIDE

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

DBF 4XL Dryer Booster Fans

breeze easytm model # F100-1W

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

Bathroom Exhaust Fan

Easy installation in both new construction and retrofit

Easy installation in both new construction and retrofit

Please Read and Save These Instructions Safety Information

FE1 Series Ventilation Fans 2007 Soleus Air International. Soleus Air Ultra Quiet Ventilation Fan

DR-180 Through the Wall Exhaust Fan PRODUCT MANUAL & INSTALLATION GUIDE

PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650

VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS. MODEL Pro200/Pro300 TABLE OF CONTENTS. Package Contents. General Safety Information

BX600. CLASSIC ColleCtion. Specifications. Model Colour Venting Size. Air Flow Volume: Electrical Consumption:

HUMIDITY SENSING BATH FAN

VENTILATION FAN / LED LIGHT

BATH FAN / LED LIGHT READ AND SAVE THESE INSTRUCTIONS MODEL GBR100LED-DECOR TABLE OF CONTENTS. Package Contents 2. General Safety Information 3

READ AND SAVE THESE INSTRUCTIONS

DEDPV-705, DEDPV-705 Hi Alt Dryer Exhaust Duct Power Ventilator (DEDPV)

VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS MODEL 50F / 70F / 70HS TABLE OF CONTENTS. Package Contents 2. General Safety Information 3

VENTILATION FAN. MFG Model : VFB80HLED2/VFB080C4L2 /VFB080C4LED2/ VFB100HLED2/VFB100C4LED1 READ AND SAVE THESE INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS WARNING! TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS OBSERVE THE FOLLOWING:

VENTILATION FAN WITH LED LIGHT AND HEATER MODEL RAD110LED

RL Series Commercial/Residential Ventilation Fan Installation Instructions Please Read And Save These Instructions.

VENTILATION FAN / LED LIGHT / LED NIGHT LIGHT

Outdoor/Commercial Refrigerator USER S MANUAL

Outdoor Refrigerator USER S MANUAL

- Oscillating Table Model Fan

READ MANUAL BEFORE OPERATING SYSTEM Read the owner s manual thoroughly before operating to ensure the most efficient use of the system.

PRO VENTILATION HOOD USE AND CARE GUIDE CLEANING, MAINTENANCE, AND MORE

Self-Cleaning Range Hoods


CVS Model Inline Multi-Port Ventilators

PLAN THE INSTALLATION Planning the installation first requires selecting the most appropriate installation approach. The chart below offers suggestion

VENTILATION FAN WITH LIGHT AND HEATER

INSTALLATION INSTRUCTIONS Trade-Wind In-Line Blower / Ventilators

INSTALLATION & OPERATING INSTRUCTIONS MODEL #17900 KEGERATOR MANUAL

INSTALLATION INSTRUCTIONS FOR DUCTED WHOLE HOUSE FANS

MULTI-FUNCTION HAND VACUUM INSTRUCTION MANUAL. For Authentic Monster Replacement Parts Call Model #: H056

HANDY/STICK 2-WAY VACUUM INSTRUCTION MANUAL. For Authentic Monster Replacement Parts Call Model #: H055

SUNCOURT RADON FAN MODEL: RDN04 & RDN04-3, RDK04 & RDK04-3 INSTALLATION INSTRUCTIONS

BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

READ AND SAVE THESE INSTRUCTIONS COOKING ONLY.! WARNING

September 2016 Humidex GVS-H Rev. 2.2En. Owner s Manual. Manufactured by: Clairitech Innovations Inc Ohio Rd. Boudreau-West, NB Canada E4P 6N4

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE 06E Series Model 06E Series Model RANGE HOOD LOCATION 1. The range hood must be installed just above the

36 IN. ELECTIC FIREPLACE FMI MODEL # LEF36 Mounting Base Feet and Wall Mounting Bracket Included

October 2016 Humidex GVS-SD Rev. 1.2En. Owner s Manual. Manufactured by: Clairitech Innovations Inc Ohio Rd. Boudreau-West, NB Canada E4P 6N4

USER'S MANUAL. Micra 150 HEAT RECOVERY UNIT

SUNCOURT INSTALLATION INSTRUCTIONS RADON FAN MODEL: RDKO4, RDK04-3, RDN04 & RDN04-3

MH70230AS MH70236AS MH70248AS

60In. Ceiling Fan. Owner s Manual

WET/DRY VACUUM. QUEST for Continuous Improvement Windsor s Quality Management System is Certified ISO MODEL: T1. Operating Instructions (ENG)

RANGE HOOD. Model SEH5636G. FELIX STORCH, INC. 770 Garrison Avenue Bronx, New York

HAZEL OWNER S MANUAL INSTALLATION GUIDE WARRANTY

READ AND SAVE THESE INSTRUCTIONS

INSTALLATION MANUAL AND USER GUIDE

READ AND SAVE THESE INSTRUCTIONS

RP, GP, XP Pro Series Installation Instructions

SOLO OWNERS MANUAL, OPERATING INSTRUCTIONS & INSTALLATION INSTRUCTIONS

! INTENDED FOR DOMESTIC COOKING ONLY!

OPERATION MANUAL Dated: 04/09/2018 Document Name: SHV _OM Page 1 of 8. Ion Technologies SHV40, 75 & 100 Sewage Ejector Pump SAFETY WARNINGS

MODEL CDB8 INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Euro-style Range Hood ESH5200

DELUXE ELECTRIC POWER BRUSH

FLCH4R Garage and Utility Electric Heater

Model 8140 & 8141 Fresh Air Ventilator Installation and Operations Manual

R Series B & T2 Model

Operating Instructions & Parts Manual. Silent Low-Profile Ceiling Fans. Models 3DPE2A, 3DPE3A, 1UBH6B, 1UBH7B, 1UBH8A, 5AE68B, 5AE69A

1 HP Air Mover. Owner s Manual

Ui REFRIGERATOR SPEC SHEET

Portable Air Conditioner, Dehumidifier,Heater and Fan utilizing Heat Pump Technology

Model KER222. BEST BY BROAN P.O. Box 140 Hartford, WI ENGLISH...3 FRANÇAIS...12 ESPAÑOL

COMPACT ELECTRIC DRYER

Wall Mounted Hoods. Use & Care Page 6. Installation Instructions Page 4. Warranty & Registration Page 9

PLEASE READ AND SAVE THESE INSTRUCTIONS

MEDICAL FREEZER. Model FS24L INSTRUCTION MANUAL. Write Serial Number (on back of unit) here:

(3 plastic wire connectors,blade balancing kit, 2 extra mounting screws #10-32 for outlet box.)

INSTALLATION AND OPERATION GUIDE

Please Read and Save These Instructions.

11,000 BTU Portable Air Conditioner with dehumidifier & Fan PE4-11R-03 Operating Instructions. Model No. PE4-11R Soleus Air International

READ AND SAVE THESE INSTRUCTIONS

USE / INSTALLATION GUIDE

Portable Air Conditioner with Evaporative Technology PE6-10R-03 Operating Instructions. Model No. PE6-10R Soleus Air International

Steam Humidifier Fan Pack Installation & Maintenance Instructions

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

OPERATION MANUAL CENTRIFUGAL INLINE FAN WITH ELECTRONICALLY COMMUTATED MOTOR VKM EC SERIES. F88EN-02.indd :07:11

INSTALLATION MANUAL AND USER GUIDE

Transcription:

IN-LINE CENTRIFUGAL FAN VENTS VKP PS 125 EN User`s manual www.vents-us.com

EN READ AND SAVE THESE INSTRUCTIONS WARNING! TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND PERSONAL INJURY, READ AND UNDERSTAND THE INSTRUCTIONS CAREFULLY 1. Use the product only in the manner intended by the manufacturer. If you have questions, contact the manufacturer. 2. Before servicing or cleaning the unit, switch off the power at the main service panel and lock it to prevent the power from accidentally being turned on. If the panel cannot be locked securely, fasten a prominent warning device, such as tag, to it. If the unit is not hard-wired but rather plugged into a 120 volt outlet, simply unplug the cord from the receptacle. 3. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, include fire-rated construction codes and standards. 4. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. 5. The fans must always be vented to the outdoors. 6. The fan may have sharp edges. Use caution to avoid being cut when installing and cleaning. 7. This fan must be grounded. CAUTION! 1. For general ventilation use only. Not for use in fire rated installations. Do not use the fan to exhaust hazardous or explosive materials and vapors. 2. For interior use only. Mount with the lowest moving parts at least 8 feet (2.5 meters) above the floor or grade level. 3. To avoid the motor damage and noisy and/or unbalanced impeller, keep drywall spray, construction duct, etc. off power unit. 4. Prior to installation operations make sure there is no visible damage to the impeller and housing. Also make sure there are no foreign objects that may have accidentally gotten into the fan. 5. Please read specification label on product for further information and requirements. 6. To be installed by qualified personnel. 7. Connect the fan through breaker box. 8. Both the inlet and outlet must have no obstructions for the VKP / VKPF to work properly and be covered by the warranty. 9. When storing the fan keep it in a dry, weather-protected environment in the original packaging. If the fan has been stored or set in a cold environment, wait 2 hours before connecting it to the power source.

WARRANTY Production meets standard operating requirements in the USA and Canada. VENTS US warrants to the original purchaser of the VKP and VKPF that it will be free from defects in materials or workmanship for a period of 60 months from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During the stated warranty period, VENTS US will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service. This warranty does not cover (a) normal maintenance and normal service or (b) any products or parts which have been subject to misuse, negligence, accident, improper maintenance or repair (other than by VENTS US), faulty installation or installation contrary to recommended installation instructions. Labor to remove and replace products is not covered. The duration of any implied warranty is limited to the time period specified for the express warranty. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. VENTS US OBLIGATION TO REPAIR OR REPLACE, AT VENTS US OPTION, SHALL BE THE PURCHASER'S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. VENTS US SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some states do not allow the exclusion or limitations of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. This warranty supersedes all prior warranties. If proof of sales date is absent, warranty period is calculated from the production date. The unit can be exchanged at the following address: Bodor Vents, LLC 1013 Kenwood Road Cincinnati, Ohio 45242 Phone: (513) 348-3853 e-mail: sales@ventsus.com Please follow guidelines in this manual for product problem-free operation.

The VENTS VKP PS Series dryer booster fan has been specially designed to solve dryer vent problems where more airflow is needed. The VENTS VKP PS dryer booster fans assure efficient and reliable operation. The pre-installed pressure switch allows the VKP PS fan to run only when it senses that the dryer is on. The controller cycles the fan until the dryer has stopped. The fans are fitted with backward curved centrifugal impeller, which allows lint not to get stuck in the fan. The VENTS VKP PS fans are driven by powerful sealed external rotor motor with lifelong bearings and thermal protection. This powerful combination enables the VENTS VKP PS fans to deliver exceptional airflow performances even in long duct runs. The fan s housing is made of galvanized steel. The external rotor motor on ball bearings and the backward curved, balanced impeller is suitable for high pressure application, prevent vibration and assure quiet operation. Each set contains: 1. Fan - 1 pc; 2. Manual; 3. Packing box. Specification: Voltage: 120 V, 60 Hz Motor: Single-phase external rotor motor with backward curvedcentrifugal impellers Duct compatibility: Ø 5 (125 mm) Airflow capacity: up to 212 CFM Power consumption: 67 W Suitable for working airstreams up to 149 F IPX4 protection Thermal overload protection Pressure switch, mounting bracket and power cord included Fan construction is constantly being improved, that is why some models can differ slightly from those described in this manual models. Fan reference scheme VKP PS 125 Outlet diameter pipe Fan type Examples of identification: A rectangular shaped in-line fan enclosed in a galvanized steel case, designed for mounting in ventilation stacks with diameter of 5" (125 mm), supplied with one inlet pipe with diameter of 5" (125 mm) VKP PS 125.

Ø 5" 7 " Dimensions 12 " 12 "

Typical installation Different variants of wall and ceiling mounting of vertical and horizontal fans are shown on Pic. 1-2. 2 1

Typical installation Install a lint trap between the clothes dryer and the fan to increase the service life and maintenance periodicity of VKP PS. Clean the lint trap as required. VKP PS Lint Trap 3

Fan installation QF The process of fan mounting with the use of a bracket together with four screws and dowels is shown on Pic. 4-8. 4 5 6 7 8

Fan installation The process of ventilation stack attachment is shown on Pic. 9-10. Air flow direction should match the direction of an arrowhead placed on the fan case. 9 10 To ensure quiet operation of ENERGY STAR qualified in-line fans, each fan shall be installed using sound attenuation techniques appropriate for the installation. Insulated flexible type duct work (recommended for all bathroom exhaust applications) will result in quieter operation. We recommend minimum 8" of insulated flexible duct between any exhaust grill and fan for low noise level. Flexible duct should be connected to the fan with hose clamps (VENTS C series is recommended), Aluminum Foil Tape or both. All connections should be as airtight as possible to maximize system performance and eliminate air leakage. When using flexible type duct work, duct should as tight and straight as possible. In case you intend to use non-flexible ducts we recommend to install flexible connectors (VENTS VVG series is highly recommended) which are designed to exclude the vibration transmission from fans to air duct. Remove any insulation from the area where you will be mounting the fan. Insulation should never be installed over any part of an exhaust fan. Keep the insulation at least 3" away from the fan casing.

Fan connection BREAKER BOX BREAKER GREEN GROUND SCREW 120 VAC, 60 Hz WALL SOCKET 120 V 60 Hz QF L PE N Pressure switch X1 ÕP1 Black Green White L PE Black 1 Green 2 White N 3 4 M Red L N ÐE Blue EARTH U1 Yellow-Green ÐÅ Ì1 U2 Z Black C1 FAN

Fan cleaning Fan surfaces need to be cleaned of dirt and dust regularly by using a soft, wet cloth and mild detergent (Pic. 16-19). Do not allow liquids to come in contact with the electric motor. Wipe surfaces dry after cleaning. QF 11 12 13 14

ACCEPTANCE CERTIFICATE Approval mark Manufactured on (date): VKP PS 125 Sold (name of trading enterprise, stamp of store) Date of sale The fan has been duly certified as serviceable. www.vents-us.com