Installation manual. Tumble dryers T4130. Compass Control

Similar documents
Installation manual. Tumble dryers T4290, T4530, T4650. Selecta Control

Installation manual Tumble dryer

Programming manual Tumble dryers Compass Control

Programming manual. Selecta II Control

Installation manual. Tumble dryers T4250, T4350. Selecta Control

Installation manual. Tumble dryer T5675. Type N /AU Installation manual in original language

CONTENTS QUICK REFERENCE GUIDE INSTRUCTIONS FOR USE PROGRAMME CHART BOOKLET

INSTRUCTIONS FOR USE - TUMBLE DRYER AWG 367

INSTRUCTIONS FOR USE TUMBLE DRYER

How to get the most from your Integrated Tumble Dryer HJA 8800

INSTRUCTIONS FOR USE TUMBLE DRYERS

INSTRUCTIONS FOR USE

Caution, risk of fire - this is a safety symbol. Failure to follow the warnings outlined in these user instructions can cause a fire hazard.

4KG Tumble Dryer / GVA4KG. Instruction Manual

Installation manual Washer extractor

OFF. 20 min. 60 min. 30 min. 60 min OFF. 100 min Start. 200 min 150 min

CONTENTS QUICK REFERENCE GUIDE PROGRAMME CHART

Installation manual Tumble dryer

INSTRUCTIONS FOR USE TUMBLE DRYER

CONTENTS QUICK REFERENCE GUIDE INSTRUCTIONS FOR USE BOOKLET PROGRAMME CHART

INSTRUCTIONS FOR USE TUMBLE DRYER

Service manual. Tumble dryers T4190. Compass Control

IMPORTANT: PLEASE READ THESE INSTRUCTIONS THOROUGHLY BEFORE USING THIS APPLIANCE. KEEP THEM IN A SAFE PLACE FOR FUTURE REFERENCE.

CI921 Integrated Tumble Dryer Installation, Use and Maintenance

Installation manual W365H, W375H, W3105H, W3130H, W3180H, W3240H, W3300H Exacta & Clarus Control

User Manual. Tumble Dryer ZDC8202P

CONTENTS READ INSTRUCTIONS FOR USE! INSTRUCTIONS FOR USE

BWTD1 Fully integrated air-vented tumble dryer

INSTRUCTIONS FOR USE 8kg CONDENSER TUMBLE DRYER B96M8WR


GETTING STARTED? EASY.

User Manual HEAT PUMP DRYER

CI560 Freestanding Condenser Dryer Installation, Use and Maintenance

Drying Cabinet Installation and Operating Manual

CDC266 Reverse Action

TK 806 Z. Bedienungs- und Wartungshandbuch. Livret d instructions et d entretien. Manuale uso e manutenzione. User instructions and maintenance

Installation and Operating Manual Drying Cabinet

GETTING STARTED? EASY.

Service manual Tumble dryers T4900, T41200 TD100, TD135

GETTING STARTED? EASY.

EDH3786GDW. EN Tumble Dryer User Manual

Portable Dryer 2.6 Cubic Feet

EDH3887GDE. EN Tumble Dryer User Manual

TUMBLE DRYER MODEL: ED-F7160(WH) Owner s Manual Please read this manual carefully before operating your set. Retain it for future reference.

OPERATION MANUAL. SENSOR TUMBLE DRYER Model:SDRY60

Installation manual Washer extractor

Operating Instructions. Tumble dryer ASKO T754HP. Dear Customer, Thank you for choosing this quality product from ASKO.

SERVICE MANUAL. T4300S, TD30x30 WARNING

User Manual Tumble Dryer LAVATHERM 61275AC

Instructions for Use. Tumble Dryer

SERVICE MANUAL T3300S TD Gas heated dryer WARNING

INSTRUCTION BOOK GCC 590NB. Condenser Tumble Dryer. English 2

INSTRUCTION BOOK. 8 Kg Condenser Tumble Dryer DNC D8513BX-AUS. English 2

Drying Cabinet Installation and Operating Manual

SERVICE MANUAL T3900/T31200 TD100/TD135

OPERATING INSTRUCTIONS EN

INSTALLATION INSTRUCTIONS USER GUIDE

User manual. Condenser dryer ZDC 37200W

User Manual Tumble Dryer LAVATHERM 65170AV

INSTRUCTION MANUAL / INSTALLATION MANUAL. 7kg Vented Dryer MODEL: KA7VENTDRYA

Contents. Dryer description, 5 To open the door The features Control panel

INSTRUCTION BOOK VTV 580NC. Vented Tumble Dryer. English 2

INSTRUCTION BOOK VTV 57NC. Vented Tumble Dryer. English 2

INSTRUCTION BOOK VTC 791NB. Condenser Tumble Dryer. English 2

INSTALLATION INSTRUCTIONS USER GUIDE. MIDEA 7kg Vented Dryer

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

OPERATING INSTRUCTIONS

CONTENTS QUICK REFERENCE GUIDE INSTRUCTIONS FOR USE PROGRAMME CHART BOOKLET

MANUAL MODEL: DRY.COND.7KG

METOS M DV-60Q1K

SERVICE MANUAL WASHING MACHINE MODEL: WM3431H*/WM3434H* WD-14312RD/WD-14316RD CAUTION

Contents. Dryer description, 4 The front The back Control panel

PDC 82 Crown TUMBLE DRYER OWNER S MANUAL

10kg / 7kg washer dryer K10W7D18. installation / instructions manual

INSTALLATION INSTRUCTIONS TD75. Vented tumble dryer DOMESTIC. Carefully read the instructions for use before using the dryer.

Operating instructions Rotary iron HM

INSTRUCTION BOOK. Condenser Tumble Dryer. English 2

DRYER USER INSTRUCTIONS

WASHING MACHINE SERVICE MANUAL CAUTION READ THIS MANUAL CAREFULLY TO DIAGNOSE PROBLEMS CORRECTLY BEFORE SERVICING THE UNIT.

Tumble Dryer OWNER S MANUAL DRV7KGWH

Bauknecht AG, Industriestrasse 36, 5600 Lenzburg,

SERVICE MANUAL WASHING MACHINE

Installation Plan Commercial Rotary Iron PM 1210 PM 1214 PM 1217

LAVATHERM 65270AC. EN User manual

User's Manual. Exhaust Type Tumble Dryer HLP140E. Please read this manual carefully before using. Retain it for future reference.

INSTRUCTION BOOK DYC 9713AX. Heat Pump Tumble Dryer. English 2

Installation instructions for vented tumble dryer DOMESTIC. Dear Customer,

GYJ45-68 INSTRUCTION MANUAL

AUTOMATIC WASHING MACHINE WITH DRYER

HEAT RECOVERY AIR HANDLING UNIT

Instructions for Installation and Use

Washing Machine. User manual WD75M4*****

Topvex SR 09, 11, Topvex TR Compact Air Handling Units

Contents. Dryer description, 5 The front The back Control panel

OPERATING INSTRUCTIONS. Drying cabinet DC 7774 DC Read the instructions before using the machine.

BMW E36 Thermostat Removal And Coolant Flush

LAVATHERM 6DBG820N LAVATHERM 6DBG821N LAVATHERM 6DBG822N. User Manual Tumble Dryer USER MANUAL

TECHNICAL INFORMATION T1500 Series Clothes Dryers

For Models FF2310APS, FF2310APW, FF2310APB 55cm FREESTANDING FRIDGE FREEZER. Instruction Manual

User Manual Tumble Dryer LAVATHERM 75380AH2

Transcription:

Installation manual Tumble dryers T4130 Type N1130 Compass Control Installation manual in original language 487 05 41 61/EN 2011.09.16

Contents 3 Contents Safety precautions... 5 Technical data... 7 Setup... 9 Unpacking... 9 Door reversal... 10 Installation... 11 Installation on board a ship... 11 Washing column... 12 Condensate dryer... 13 Installation of ventilating system... 13 Changing over condensate dryers... 14 Evacuation system... 15 Air principle... 15 Fresh-air... 15 Exhaust duct... 16 Electric installation... 18 External fan... 18 Cable dimensioning table... 19 Function check... 21 The manufacturer reserves the right to make changes to design and com ponent specifications.

Safety Precautions 5 Safety Precautions Do not dry unwashed items in the machine The machine is not to be used if industrial chemicals have been used for cleaning. Do not allow minors to use the machine. Do not hose down the machine with water. The machine's door lock must under no circumstances be bypassed. Items that have been soiled with substances such as cooking oil, acetone, alcohol, petrol, kerosene, spot removers, turpentine, waxes and wax removers should be washed in hot water with an extra amount of detergent before being dried in the machine. Items such as foam rubber (latex foam), shower caps, waterproof textiles, rubber backed articles and clothes or pillows fitted with foam rubber pads should not be dried in the machine. Fabric softeners or similar products should be used as specified by the fabric softener instructions. The machine may not be used to dry floor mops that contain polypropylene. The final part of a drying cycle occurs without heat (cool down cycle) to ensure that the items are left at a temperature that ensures that the items will not be damaged. WARNING. Never stop the machine before the end of the drying cycle unless all items are quickly removed and spread out so that the heat is dissipiated. Remove garments from the machine as soon as they are dried. This prevents them from becoming creased and reduces the risk of spontaneous ignition. If the machine develops a fault, this must be reported to the person in charge as soon as possible. This is important both for your safety and that of others. The machine must not be located where a door, sliding door, etc., can block the machine's door The machine is not intended to be used by people (including minors) with reduced physical or mental capacity or lack of experience and knowledge. Such people must be instructed in the use of the machine by a person who has responsibility for their safety. Minors must be supervised to ensure that they do not play with the machine. Adequate ventilation has to be provided to avoid the back flow of gases into the room for appliances burning other fuels, including open fires. Gas heated tumble dryer: The machine is not to be installed in rooms containing cleaning machines with perchloroethylene, TRICHLOROETHYLENE or CHLOROFLUOROCONTAINING HYDROCARBONS as cleaning agents. If you can smell gas, Do not switch on any equipment Do not use electrical switches Do not use telephones in the building Evacuate the room, building or area Contact the person responsible for the machine In order to prevent damage to the electronics (and other parts) that may occur as the result of condensation, the machine should be placed in room temperature for 24 hours before being used for the first time.

Technical data 7 Technical data T4130/T4130C Standard Condensate Drum volume Weight net Drum diameter depth revolutions g-factor Capacity, max Heat effect Motor effect revolutions 50 Hz revolutions 60 Hz litres kg mm mm rpm kg kw kw rpm rpm Air consumption m 3 /h Piping evacuation condensate water Pressure drop evacuation 50/60 Hz Sound pressure level ø max Pa db (A) 130 130 54 57 575 575 500 500 53 53 0.9 0.9 6 6 5.1/3.2 3.0 0.13 0.20 2730 2730 3330 3330 260-100 - - 1/2" hose to drain 60 - < 70 < 70

8 Technical data Dimension sketch 595 735 850 Ø 100 310 100 W00201 78 197 78 510 44 Connecting branch - condensate dryers only 402 fl 14 1260 500 105 49 115 235 W00202 550 Exhaust duct - standard dryers only

Setup 9 Setup 1 Unpacking Unpack the dryer from the packaging. There are no transportation fittings. Release the dryer from the pallet by cutting the plastic ribbon.. Positioning 1 Place the dryer in such a way that work can be done as easily as possible by the user as well as the service technician. The door is reversible. The distance to the wall or other equipment behind the dryer should be min. 300 mm and the distance to the sides min. 70 mm (if the dryer is to be equipped with a coin box the width of the coin box must also be added). However, for the purpose of servicing the dryer there should be free access to the back of it. 2 W00176 The dryer can be positioned on a 55-litre washing machine to form a washing column. Mechanical installation 2 Adjust the dryer to ensure that it is horizontal and stands firmly on all 4 feet. The max. height adjustment is 14 mm. Floor mounting 3 The dryer can be installed directly on the floor and fastened by means of the accompanying cups A. Fasten the cups by means of the screws. W00177 A drilling plan is given in fig. 3 in the form of alternative 1 (from the rear) or 2 (from the side), depending on the space for mounting the rocker brackets B. Drill the rawlplug holes using a 10 mm drill. 3 402 95 Alt. 1 42,5 15,5 A 510 564 Alt. 1 B 42,5 15,5 Alt. 1 Alt. 2 375 122 Alt. 2 Alt. 2 Front 133 47,5 500 47,5 133 W00178, W00179

10 Setup Door reversal 1. Disconnect the power supply to the dryer. 2. Loosen the hinge mounting and push it down to allow the door to be lifted off. Unscrew the hinge mounting. NB! Hold the door securely while loosening the screws. W00180 W00181 3. Unscrew the cover screws at the opposite side and loosely mount the hinge mounting. Screw in the cover screws where the hinge was previously mounted. W00182 Upper pivot TOP Lower pivot W00183 4. Remove the three black plugs at the top of the door. 5. Dismount the handle by loosening the three screws. 6. Remove the pivot at the top to the other side. 7. Mount the handle at the opposite side where the plugs used to be. 8. Insert the plugs where the handle used to be. 9. Remove the bottom pivot to the other side. 10. Release the locking plates by loosening the barb with a screwdriver. 11. Press out the locking plates, swap them over and press into position. TOP W00185 W00184 A 12. Mount the door. Push the hinge mounting upwards and tighten the screws. 13. Test the door (use washers to adjust the hinge if necessary). Check that door pin (A) is aligned with the microswitch aperture. 14. Connect the power to the dryer. Finally, check that the dryer stops when the door is opened. W00186

Installation 11 Installation Installation on board a ship 1 If the dryer is intended for installation on board a ship, fittings are mounted from factory (instead of feet) on the dryer for attachment to the ship floor by means of 4 M8 bolts. Drilling plan, see fig. 1. 1 12,5 573 12,5 FRONT 28 M8 416 100 175 W00187

12 Installation Washing column The dryer can be installed on top of a 55-litre washing machine WE455H or on a 130-litre dryer T4130(C). 2 The washer at the bottom must be levelled and rest on all four feet. A 2 Place the frame on the top plate of the lower machine, ensuring that the holes for the fastening bracket A are at the rear. Screw the dryer feet of the upper machine all the way home to ensure that they do not touch the top plate of the lower machine. 3 Lift the dryer into position, thereby making sure that the machine fronts are flush. As a protection against tilting, the two accompanying plate screws are to be inserted in either side in holes B. 3 W00188 If holes B are not provided in the side plates, drill them with a 3.3 mm drill. Note! If it is hard to read the display adjust the contrast in the service menu (see the programming manual supplied with the dryer. B W00189, W00190

Installation 13 Condensate dryer 4 The condensate dryer does not have ventilation (evacuation) into the open. The air is circulated in a closed system between the dryer and condensing unit. The water in the garments condenses in the condensing unit. All the energy (3,4/2,4 kw) used for drying the garments ends up in the room in the form of heat. During operation, the room experiences a temperature increase, which results in a need for ventilation. The moisture ends up as water in the drains. Note! The hose must be "sloping" towards the drain and not form a water trap. Installation of ventilating system For ventilation, a thermostatically controlled fan, type EQ 250, is used. It can be ordered as item no. 988 80 20 43. 5 The fan is to be placed on a wall facing the outside behind the condensate dryer, while the thermostat is placed further into the room in an accessible place. The fresh air intake must end in the room in front of the dryer, positioned diagonally from the fan. Pressure drop max.: 10 Pa. The fresh air requirement per dryer is 750 m 3 /h (if the temperature is kept constant). The need for fresh air varies and is controlled by the thermostat. 4 5 W00203, W00191 W00192

14 Installation Changing over condensate dryers To be carried out by qualified personnel 3 x 400/415V + N 3,4kW B1 3 x 200/230/240V 3,4kW B1 W00193 W00194 1 x 230/240V 3,4kW Applies to all dryer types B1 W00195 W00196

Installation 15 Evacuation system (does not apply to condensate dryers) 6 Air principle The ventilator creates low pressure in the dryer, drawing air into the drum via the heating unit. The heated air passes through the garments and the holes of the coarse filter. Then the air flows through a lint screen positioned in the door. After this, the air is evacuated through the fan and the evacuation system. It is very important that the dryer gets enough fresh air, see next section. A 5 x A Fresh-air 6 For the machine to work optimally with the shortest possible drying time, it is important for the air input to the room to come from an aperture from outside through which the same amount of air is taken into the room as is blown out. To avoid a draught in the room, the air inlet should preferably be placed behind the dryer. 7 The free area* of the air inlet aperture must be five times the area of the exhaust duct. The resistance in the grating/slats should not exceed 10 Pa (0.1 mbar). Note that grates/slatted openings often block half the total area of the fresh air intake.remember to make allowance for this fact when dimensioning. * The free area is the area which the air can flow through without resistance from grate/slatted opening. 7 W00197 5 x A W00048

16 Installation Exhaust duct 8 The exhaust duct must be smooth on the inside (low air resistance). The exhaust duct must lead to the outdoors. The exhaust duct must lead clear of the building as condensation may cause frost damage to the building. The exhaust duct must be protected against rain and foreign objects. The exhaust duct must have gentle bends. The exhaust duct must not be a shared duct between dryers and appliances using gas or other fuels as their energy source. When several dryers share an exhaust duct 9 The exhaust duct diameter must increase after each dryer. The table below shows the exhaust duct diameter and the necessary fresh-air inlet area. Note! It is recommended that each dryer is connected to a separate exhaust duct. The evacuation pipe diameter must not be reduced. No. of dryers 1 2 3 4 Exhaust m 3 /h 260 520 780 1040 d ø mm 100 100 100 100 Fresh air inlet cm 2 400 800 1200 1600 Exhaust duct length 0-6 m d ø 100 160 200 250 ** Exhaust duct length 6-50 m d ø 160 200 250 350 ** If the exhaust duct lenght exceeds 6 m the diameter must be increased.

Installation 17 Gentle bends 8 W00145 Several dryers share an exhaust duct 9 W00198

18 Installation Electric installation 5 To be carried out by qualified personnel The dryer must be given a fuse group of its own and switch in accordance with IEC 60947. For each dryer, a multi-pole permanent switch is to be placed in the permanent installation. It must be easily accessible, but there must be no mistaking it for the operating switch for the dryer. The motor features an integrated thermal fuse, which is why motor protection in the installation is unnecessary. Remove the top plate of the dryer to connect the cable. Install the dryer as a permanent installation. See dimensions in the table. Function check, see next page. The dryer must be equipped with supplementary protection in accordance with current regulations. Connection of external contactor Ext. connection Max. 1,25A (Does not apply to marine models) W00199 External fan A connection terminal is available for controlling an external fan.

Installation 19 Cable dimensioning table Type Voltage Power intake Heating Fuse kw kw A Standard dryer 400-440V 3N / 3 AC 5.3 5.1 10 200-240V 3 AC 5.3 5.1 16 230-240V 3 AC 3.4 3.2 10 230-240V 1 AC 3.4 3.2 16 Condensate dryer 400-440V 3N / 3 AC 3.4 3.0 10 230-240V 3 AC 3.4 3.0 10 230-240V 1 AC 3.4 3.0 16 200V 3 AC 3.4 3.0 16

Function check 21 Function check 1 To be carried out by qualified personnel Check whether the drum is empty and the door has been closed. Start the dryer Check whether the door lock is working: The drum must stop if the loading door is opened. 1 The dryer has a single phase motor, which is why the direction of rotation (clockwise) is always correct. W00200 Marine version For dryers on board a ship (3-phase motor) the direction of rotation must be checked. If the direction of rotation is not correct, swop two phases on the connection terminal. Final test Let the dryer work for 5 minutes on a program that requires heat. Then check whether the heating is working by opening the front door and feel the heat. If the above tests-points are in order, the dryer is ready for use. Service organisation/dealer If deficiencies or errors are detected, please contact your local service organisation/dealer.